{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T04:42:58Z","timestamp":1790656978140,"version":"4.1.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,1,21]],"date-time":"2020-01-21T00:00:00Z","timestamp":1579564800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,1,21]],"date-time":"2020-01-21T00:00:00Z","timestamp":1579564800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s10856-019-6357-0","type":"journal-article","created":{"date-parts":[[2020,1,21]],"date-time":"2020-01-21T02:02:50Z","timestamp":1579572170000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["In vivo osseointegration of a randomized trabecular titanium structure obtained by an additive manufacturing technique"],"prefix":"10.1007","volume":"31","author":[{"given":"Vincenza","family":"Ragone","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Canciani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimo","family":"Arosio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Olimpo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lisa Adele","family":"Piras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitzy Mauthe","family":"von Degerfeld","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davide","family":"Augusti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1216-792X","authenticated-orcid":false,"given":"Riccardo","family":"D\u2019Ambrosi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudia","family":"Dellavia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,1,21]]},"reference":[{"key":"6357_CR1","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1002\/acr.20231","volume":"62","author":"JN Katz","year":"2010","unstructured":"Katz JN, Earp BE, Gomoll AH. Surgical management of osteoarthritis. Arthritis Care Res (Hoboken). 2010;62:1220\u20138.","journal-title":"Arthritis Care Res (Hoboken)"},{"key":"6357_CR2","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1002\/jbm.a.32063","volume":"90","author":"SB Goodman","year":"2009","unstructured":"Goodman SB, G\u00f3mez Barrena E, Takagi M, Konttinen YT. Biocompatibility of total joint replacements: a review. J Biomed Mater Res A. 2009;90:603\u201318.","journal-title":"J Biomed Mater Res A."},{"key":"6357_CR3","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1586\/17434440.5.3.383","volume":"5","author":"K Lee","year":"2008","unstructured":"Lee K, Goodman SB. Current state and future of joint replacements in the hip and knee. Expert Rev Med Dev. 2008;5:383\u201393.","journal-title":"Expert Rev Med Dev"},{"key":"6357_CR4","doi-asserted-by":"publisher","first-page":"S96","DOI":"10.1007\/s005860100282","volume":"10","author":"T Albrektsson","year":"2001","unstructured":"Albrektsson T, Johansson C. Osteoinduction, osteoconduction and osseointegration. Eur Spine J. 2001;10:S96\u2013101.","journal-title":"Eur Spine J"},{"key":"6357_CR5","first-page":"S49","volume":"38","author":"J Schatzker","year":"1995","unstructured":"Schatzker J. Osseointegration of metal. Can J Surg. 1995;38:S49\u201354.","journal-title":"Can J Surg"},{"key":"6357_CR6","doi-asserted-by":"publisher","first-page":"5474","DOI":"10.1016\/j.biomaterials.2005.02.002","volume":"26","author":"V Karageorgiou","year":"2005","unstructured":"Karageorgiou V, Kaplan D. Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials. 2005;26:5474\u201391.","journal-title":"Biomaterials."},{"key":"6357_CR7","doi-asserted-by":"publisher","first-page":"045007","DOI":"10.1088\/1758-5082\/6\/4\/045007","volume":"6","author":"A Cheng","year":"2014","unstructured":"Cheng A, Humayun A, Cohen DJ, et al. Additively manufactured 3D porous Ti-6Al-4V constructs mimic trabecular bone structure and regulate osteoblast proliferation, differentiation and local factor production in a porosity and surface roughness dependent manner. Biofabrication. 2014;6:045007.","journal-title":"Biofabrication."},{"key":"6357_CR8","doi-asserted-by":"publisher","first-page":"1689","DOI":"10.1002\/jbm.b.33146","volume":"102","author":"Z Zhang","year":"2014","unstructured":"Zhang Z, Yuan L, Lee PD, et al. Modeling of time dependent localized flow shear stress and its impact on cellular growth within additive manufactured titanium implants. J Biomed Mater Res B Appl Biomater. 2014;102:1689\u201399.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"6357_CR9","doi-asserted-by":"publisher","first-page":"4055","DOI":"10.1016\/j.msec.2013.05.050","volume":"33","author":"Z Zhang","year":"2013","unstructured":"Zhang Z, Jones D, Yue S, et al. Hierarchical tailoring of strut architecture to control permeability of additive manufactured titanium implants. Mater Sci Eng C Mater Biol Appl. 2013;33:4055\u201362.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"6357_CR10","doi-asserted-by":"publisher","first-page":"255","DOI":"10.3184\/003685012X13420984463047","volume":"95","author":"TJ Horn","year":"2012","unstructured":"Horn TJ, Harrysson OL. Overview of current additive manufacturing technologies and selected applications. Sci Prog. 2012;95:255\u201382.","journal-title":"Sci Prog."},{"key":"6357_CR11","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1002\/jbm.b.32764","volume":"100","author":"A Basalah","year":"2012","unstructured":"Basalah A, Shanjani Y, Esmaeili S, Toyserkani E. Characterizations of additive manufactured porous titanium implants. J Biomed Mater Res B Appl Biomater. 2012;100:1970\u20139.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"6357_CR12","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.physa.2007.07.063","volume":"385","author":"J-S Ferenc","year":"2007","unstructured":"Ferenc J-S, Neda Z. On the size distribution of Poisson Voronoi cells. Phys A. 2007;385:518\u201326.","journal-title":"Phys A."},{"key":"6357_CR13","doi-asserted-by":"publisher","first-page":"066119","DOI":"10.1103\/PhysRevE.70.066119","volume":"70","author":"E Pineda","year":"2004","unstructured":"Pineda E, Bruna P, Crespo D. Cell size distribution in random tessellations of space. Phys Rev E Stat Nonlin Soft Matter Phys. 2004;70:066119.","journal-title":"Phys Rev E Stat Nonlin Soft Matter Phys"},{"key":"6357_CR14","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.actbio.2016.06.032","volume":"42","author":"S G\u00f3mez","year":"2016","unstructured":"G\u00f3mez S, Vlad MD, L\u00f3pez J, Fern\u00e1ndez E. Design and properties of 3D scaffolds for bone tissue engineering. Acta Biomater. 2016;42:341\u201350.","journal-title":"Acta Biomater"},{"key":"6357_CR15","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1016\/j.arth.2010.12.007","volume":"26","author":"N Bertollo","year":"2011","unstructured":"Bertollo N, Matsubara M, Shinoda T, et al. Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium. J Arthroplast. 2011;26:1000\u20137.","journal-title":"J Arthroplast."},{"key":"6357_CR16","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1054\/arth.2002.30410","volume":"17","author":"M Svehla","year":"2002","unstructured":"Svehla M, Morberg P, Bruce W, et al. The effect of substrate roughness and hydroxyapatite coating thickness on implant shear strength. J Arthroplast. 2002;17:304\u201311.","journal-title":"J Arthroplast"},{"key":"6357_CR17","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1111\/j.2041-1626.2011.00052.x","volume":"2","author":"C Dellavia","year":"2011","unstructured":"Dellavia C, Carmagnola D, Storelli S, et al. Histological evaluation of the peri-implant tissues of three human-retrieved Straumann implants. J Investig Clin Dent. 2011;2:216\u201320.","journal-title":"J Investig Clin Dent"},{"key":"6357_CR18","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1563\/AAID-JOI-D-13-00036","volume":"41","author":"E Varoni","year":"2015","unstructured":"Varoni E, Canciani E, Palazzo B, et al. Effect of Poly-L-Lysine coating on titanium osseointegration: from characterization to in vivo studies. J Oral Implantol. 2015;41:626\u201331.","journal-title":"J Oral Implantol"},{"key":"6357_CR19","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1097\/ID.0000000000000560","volume":"26","author":"MD Fabbro","year":"2017","unstructured":"Fabbro MD, Taschieri S, Canciani E, et al. Osseointegration of titanium implants with different rough surfaces: a histologic and histomorphometric study in an adult minipig model. Implant Dent. 2017;26:357\u201366.","journal-title":"Implant Dent"},{"key":"6357_CR20","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1186\/1749-799X-6-56","volume":"6","author":"D Chen","year":"2011","unstructured":"Chen D, Bertollo N, Lau A, et al. Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model. J Orthop Surg Res. 2011;6:56.","journal-title":"J Orthop Surg Res"},{"key":"6357_CR21","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.arth.2013.10.003","volume":"30","author":"N Bertollo","year":"2015","unstructured":"Bertollo N, Sandrini E, Dalla Pria P, Walsh WR. Osseointegration of multiphase anodic spark deposition treated porous titanium implants in an ovine model. J Arthroplast. 2015;30:484\u20138.","journal-title":"J Arthroplast"},{"key":"6357_CR22","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/jbm.820260111","volume":"26","author":"WJ Dhert","year":"1992","unstructured":"Dhert WJ, Verheyen CC, Braak LH, et al. A finite element analysis of the push-out test: influence of test conditions. J Biomed Mater Res. 1992;26:119\u201330.","journal-title":"J Biomed Mater Res"},{"key":"6357_CR23","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1177\/00220345860650020701","volume":"65","author":"RJ Hunt","year":"1986","unstructured":"Hunt RJ. Percent agreement, Pearson\u2019s correlation, and kappa as measures of inter-examiner reliability. J Dent Res. 1986;65:128\u201330.","journal-title":"J Dent Res"},{"key":"6357_CR24","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1089\/ten.tec.2008.0288","volume":"15","author":"PH Warnke","year":"2009","unstructured":"Warnke PH, Douglas T, Wollny P, et al. Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering. Tissue Eng Part C Methods. 2009;15:115\u201324.","journal-title":"Tissue Eng Part C Methods"},{"key":"6357_CR25","doi-asserted-by":"publisher","first-page":"1917","DOI":"10.1007\/s11665-014-0958-z","volume":"23","author":"WE Frazier","year":"2014","unstructured":"Frazier WE. Metal additive manufacturing: a review. J Mater Eng Perform. 2014;23:1917\u201328.","journal-title":"J Mater Eng Perform"},{"key":"6357_CR26","doi-asserted-by":"publisher","first-page":"4192","DOI":"10.1016\/j.biomaterials.2006.03.034","volume":"27","author":"H Wang","year":"2006","unstructured":"Wang H, Eliaz N, Xiang Z, et al. Early bone apposition in vivo on plasma-sprayed and electrochemically deposited hydroxyapatite coatings on titanium alloy. Biomaterials. 2006;27:4192\u2013203.","journal-title":"Biomaterials."},{"key":"6357_CR27","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-015-0822-9","volume":"16","author":"L Perticarini","year":"2015","unstructured":"Perticarini L, Zanon G, Rossi SM, Benazzo FM. Clinical and radiographic outcomes of a trabecular titanium\u2122 acetabular component in hip arthroplasty: results at minimum 5 years follow-up. BMC Musculoskelet Disord. 2015;16:375.","journal-title":"BMC Musculoskelet Disord"},{"key":"6357_CR28","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1007\/s00264-014-2509-5","volume":"39","author":"B Steno","year":"2015","unstructured":"Steno B, Kokavec M, Necas L. Acetabular revision arthroplasty using trabecular titanium implants. Int Orthop. 2015;39:389\u201395.","journal-title":"Int Orthop"},{"key":"6357_CR29","first-page":"199","volume":"65","author":"A Bistolfi","year":"2014","unstructured":"Bistolfi A, Ravera L, Graziano E, et al. A Trabecular Titanium\u2122 cup for total hip arthroplasty: a preliminary clinical and radiographic report. Minerva Ortopedica e Traumatologica. 2014;65:199\u2013205.","journal-title":"Minerva Ortopedica e Traumatologica"},{"key":"6357_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.22203\/eCM.v013a01","volume":"13","author":"AI Pearce","year":"2007","unstructured":"Pearce AI, Richards RG, Milz S, et al. Animal models for implant biomaterial research in bone: a review. Eur Cell Mater. 2007;13:1\u201310.","journal-title":"Eur Cell Mater."},{"key":"6357_CR31","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1002\/jbm.a.30038","volume":"69","author":"BM Willie","year":"2004","unstructured":"Willie BM, Bloebaum RD, Bireley WR, et al. Determining relevance of a weight-bearing ovine model for bone ingrowth assessment. J Biomed Mater Res A. 2004;69:567\u201376.","journal-title":"J Biomed Mater Res A"},{"key":"6357_CR32","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1002\/jor.23075","volume":"34","author":"SL Sing","year":"2016","unstructured":"Sing SL, An J, Yeong WY, Wiria FE. Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs. J Orthop Res. 2016;34:369\u201385.","journal-title":"J Orthop Res."},{"key":"6357_CR33","first-page":"271","volume":"21","author":"JE Biemond","year":"2011","unstructured":"Biemond JE, Hannink G, Verdonschot N, et al. The effect of E-beam engineered surface structures on attachment, proliferation and differentiation of human mesenchymal stem cells. Biomed Mater Eng. 2011;21:271\u20139.","journal-title":"Biomed Mater Eng"},{"key":"6357_CR34","doi-asserted-by":"publisher","first-page":"2645","DOI":"10.1089\/ten.tea.2012.0753","volume":"19","author":"M de Wild","year":"2013","unstructured":"de Wild M, Schumacher R, Mayer K, et al. Bone regeneration by the osteoconductivity of porous titanium implants manufactured by selective laser melting: a histological and micro computed tomography study in the rabbit. Tissue Eng. 2013;19:2645\u201354.","journal-title":"Tissue Eng"},{"key":"6357_CR35","doi-asserted-by":"publisher","first-page":"025021","DOI":"10.1088\/1748-605X\/aa6810","volume":"12","author":"DJ Cohen","year":"2017","unstructured":"Cohen DJ, Cheng A, Sahingur K, et al. Performance of laser sintered Ti-6Al-4V implants with bone-inspired porosity and micro\/nanoscale surface roughness in the rabbit femur. Biomed Mater. 2017;12:025021.","journal-title":"Biomed Mater"},{"key":"6357_CR36","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1016\/j.msec.2015.10.069","volume":"59","author":"N Taniguchi","year":"2016","unstructured":"Taniguchi N, Fujibayashi S, Takemoto M, et al. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment. Mater Sci Eng C Mater Biol Appl. 2016;59:690\u2013701.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"key":"6357_CR37","doi-asserted-by":"publisher","first-page":"e50","DOI":"10.11607\/prd.1786","volume":"34","author":"D Carmagnola","year":"2014","unstructured":"Carmagnola D, Botticelli D, Canciani E, et al. Histologic and immunohistochemical description of early healing at marginal defects around implants. Int J Periodontics Restor Dent. 2014;34:e50\u20137.","journal-title":"Int J Periodontics Restor Dent."},{"key":"6357_CR38","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1111\/cid.12381","volume":"18","author":"L Canullo","year":"2016","unstructured":"Canullo L, Wiel Marin G, Tallarico M, et al. Histological and Histomorphometrical evaluation of postextractive sites grafted with mg-enriched nano-hydroxyapatite: a randomized controlled trial comparing 4 versus 12 months of healing. Clin Implant Dent Relat Res. 2016;18:973\u201383.","journal-title":"Clin Implant Dent Relat Res."},{"key":"6357_CR39","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1007\/s00776-012-0349-y","volume":"18","author":"E Arrigoni","year":"2013","unstructured":"Arrigoni E, de Girolamo L, Di Giancamillo A, et al. Adipose-derived stem cells and rabbit bone regeneration: histomorphometric, immunohistochemical and mechanical characterization. J Orthop Sci. 2013;18:331\u20139.","journal-title":"J Orthop Sci."}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-019-6357-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10856-019-6357-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-019-6357-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,19]],"date-time":"2021-01-19T19:12:46Z","timestamp":1611083566000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10856-019-6357-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,21]]},"references-count":39,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["6357"],"URL":"https:\/\/doi.org\/10.1007\/s10856-019-6357-0","relation":{},"ISSN":["0957-4530","1573-4838"],"issn-type":[{"value":"0957-4530","type":"print"},{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,21]]},"assertion":[{"value":"14 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"VR and MA are employees of Permedica S.p.A. These authors did not have a role in the in analysis and interpretation of the data. They had no possibility to influence or to change the results of this study. The other authors, their immediate families, and any research foundation with which they are affiliated have not received any financial payments or other benefits from any commercial entity related to the subject of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"17"}}