{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:12:35Z","timestamp":1792613555104,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Mater Sci: Mater Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Purpose: Double-crown-retained dentures (DCRD) are an established treatment in dentistry. In some cases, the retention between primary crown (PC) and secondary crown (SC) loosens due to wear during daily handling of the denture. The aim of the present study was to examine modern materials for PCs and SCs with regard to their wear behavior. Materials and Methods: Cyclic pull-off tests were conducted on each 40 specimens in five test groups. PCs made of CoCr, PEEK and ZrO\n                    <jats:sub>2<\/jats:sub>\n                    were cemented onto a prepared resin tooth. SCs were made of the same materials and combined to the following PC-SC combinations: CoCr-CoCr, CoCr-PEEK, PEEK-PEEK, ZrO\n                    <jats:sub>2<\/jats:sub>\n                    -PEEK, ZrO\n                    <jats:sub>2<\/jats:sub>\n                    -ZrO\n                    <jats:sub>2<\/jats:sub>\n                    . The wear areas on the contact surfaces between the PCs and the SCs were examined on SEM images. Results: Wear marks in form of scratches, chipping, ductile deformation or combinations of these forms were observed on the PCs and SCs in the various material combinations. The greatest wear on PCs was observed in the PEEK-PEEK group, while the greatest wear on SCs was observed in the ZrO\n                    <jats:sub>2<\/jats:sub>\n                    -ZrO\n                    <jats:sub>2<\/jats:sub>\n                    group. The least wear was observed on SCs made of PEEK in combination with PCs made of ZrO\n                    <jats:sub>2<\/jats:sub>\n                    . Conclusion: When using modern materials for DCRDs, the combination of different materials for PCs and SCs must be taken into account. The data found in this study show that only minor wear occurs at SCs made of PEEK, especially in combination with PCs made of ZrO\n                    <jats:sub>2<\/jats:sub>\n                    . Therefore, this combination seems particularly suitable for increasing the longevity of DCRDs.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Graphical Abstract<\/jats:bold>\n                  <\/jats:p>","DOI":"10.1007\/s10856-025-06891-6","type":"journal-article","created":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T04:03:25Z","timestamp":1747195405000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["In-vitro study of the wear behavior of telescopic crowns made of CoCr, zirconia or PEEK"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1217-377X","authenticated-orcid":false,"given":"PC.","family":"Pott","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2043-6605","authenticated-orcid":false,"given":"N.","family":"v. Maltzahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9338-1399","authenticated-orcid":false,"given":"C.","family":"Brachmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5953-2517","authenticated-orcid":false,"given":"M.","family":"Stiesch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4841-1154","authenticated-orcid":false,"given":"P.","family":"Kohorst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,14]]},"reference":[{"key":"6891_CR1","doi-asserted-by":"publisher","first-page":"518","DOI":"10.2186\/jpr.JPR_D_22_00165","volume":"67","author":"V Kopzon","year":"2023","unstructured":"Kopzon V, Raedel M. Outcomes of abutment teeth with double crowns over an observation period of 27 years. J Prosthodont Res. 2023;67:518\u201323.","journal-title":"J Prosthodont Res"},{"key":"6891_CR2","first-page":"29","volume":"17","author":"T Widbom","year":"2004","unstructured":"Widbom T, L\u00f6fquist L, Widbom C, S\u00f6derfeldt B, Kronstr\u00f6m M. Tooth-supported telescopic crown-retained dentures: an up to 9-year retrospective clinical follow-up study. Int J Prosthodont. 2004;17:29\u201334.","journal-title":"Int J Prosthodont"},{"key":"6891_CR3","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1159\/000529154","volume":"32","author":"GG Zafiropoulos","year":"2023","unstructured":"Zafiropoulos GG, Abuzayeda M, Murray CA, Baig MR. Double crown-retained removable prostheses supported by implants or teeth and implants: a long-term clinical retrospective evaluation. Med Princ Pr. 2023;32:61\u201370.","journal-title":"Med Princ Pr"},{"key":"6891_CR4","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.prosdent.2014.02.017","volume":"112","author":"FS Schwindling","year":"2014","unstructured":"Schwindling FS, Dittmann B, Rammelsberg P. Double-crown-retained removable dental prostheses: a retrospective study of survival and complications. J Prosthet Dent. 2014;112:488\u201393.","journal-title":"J Prosthet Dent"},{"key":"6891_CR5","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.dental.2020.10.028","volume":"37","author":"V Luft","year":"2021","unstructured":"Luft V, Pospiech P, Schurig A, Schmitter M. In vitro investigations on retention force behavior of conventional and modern double crown systems. Dent Mater. 2021;37:191\u2013200.","journal-title":"Dent Mater"},{"key":"6891_CR6","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1590\/S1678-77572012000300015","volume":"20","author":"S Bayer","year":"2012","unstructured":"Bayer S, Kraus D, Keilig L, G\u00f6lz L, Stark H, Enkling N. Wear of double crown systems: electroplated vs. casted female part. J Appl Oral Sci. 2012;20:384\u201391.","journal-title":"J Appl Oral Sci"},{"key":"6891_CR7","first-page":"20","volume":"32","author":"RMK Emera","year":"2024","unstructured":"Emera RMK, Askar O. Surface wear and retention force of zirconia and PEKK implant-retained crowns. Eur J Prosthodont Restor Dent. 2024;32:20\u201327.","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"6891_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-024-04839-w","volume":"24","author":"SM Abdel Hamid","year":"2024","unstructured":"Abdel Hamid SM, Selima RA, Basiony MZ. Surface topography changes and wear resistance of different non-metallic telescopic crown attachment materials in implant retained overdenture (prospective comparative in vitro study). BMC Oral Health. 2024;24:1123.","journal-title":"BMC Oral Health"},{"key":"6891_CR9","doi-asserted-by":"publisher","first-page":"3228.","DOI":"10.3390\/ma13143228","volume":"13","author":"C Arnold","year":"2020","unstructured":"Arnold C, Schweyen R, Boeckler A. Retention force of removable partial dentures with CAD-CAM-Fabricated telescopic crowns. Materials. 2020;13:3228.","journal-title":"Materials"},{"key":"6891_CR10","first-page":"43","volume":"15","author":"T Dabrowa","year":"2013","unstructured":"Dabrowa T, Dobrowolska A, Wieleba W. The role of friction in the mechanism of retaining the partial removable dentures with double crown system. Acta Bioeng Biomech. 2013;15:43\u20138.","journal-title":"Acta Bioeng Biomech"},{"key":"6891_CR11","first-page":"257","volume":"53","author":"M Eisenburger","year":"1998","unstructured":"Eisenburger M, Tscherntischek H. Clinical-technical comparison of the long-term success of clasp-retained dentures and telescopic prostheses. Dtsch Zahn\u00e4rztl Z. 1998;53:257\u20139.","journal-title":"Dtsch Zahn\u00e4rztl Z"},{"key":"6891_CR12","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1007\/s00784-011-0530-2","volume":"16","author":"S Bayer","year":"2012","unstructured":"Bayer S, Stark H, G\u00f6lz L, Keilig L, Kraus D, Hansen A, et al. Clinical retention force development of double crowns. Clin Oral Investig. 2012;16:407\u201311.","journal-title":"Clin Oral Investig"},{"key":"6891_CR13","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1016\/j.dental.2021.08.020","volume":"37","author":"M Priester","year":"2021","unstructured":"Priester M, M\u00fcller WD, Beuer F, Schmidt F, Schwitalla AD. Performance of PEEK based telescopic crowns, a comparative study. Dent Mater. 2021;37:1667\u201375.","journal-title":"Dent Mater"},{"key":"6891_CR14","doi-asserted-by":"publisher","first-page":"4615","DOI":"10.3390\/polym14214615","volume":"14","author":"Y Liu","year":"2022","unstructured":"Liu Y, Fang M, Zhao R, Liu H, Li K, Tian M, et al. Clinical applications of polyetheretherketone in removable dental prostheses: accuracy, characteristics, and performance. Polym. 2022;14:4615.","journal-title":"Polym"},{"key":"6891_CR15","doi-asserted-by":"publisher","first-page":"308","DOI":"10.4047\/jap.2017.9.4.308","volume":"9","author":"M \u00c7elik G\u00fcven","year":"2017","unstructured":"\u00c7elik G\u00fcven M, Tuna M, Bozda\u011f E, \u00d6zt\u00fcrk GN, Bayraktar G. Comparison of retention forces with various fabrication methods and materials in double crowns. J Adv Prosthodont. 2017;9:308\u201314.","journal-title":"J Adv Prosthodont"},{"key":"6891_CR16","doi-asserted-by":"publisher","first-page":"2023","DOI":"10.1007\/s00784-013-1183-0","volume":"18","author":"I Turp","year":"2014","unstructured":"Turp I, Bozda\u011f E, S\u00fcnb\u00fclo\u011flu E, Kahruman C, Yusufo\u011flu I, Bayraktar G. Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig. 2014;18:2023\u201335.","journal-title":"Clin Oral Investig"},{"key":"6891_CR17","doi-asserted-by":"publisher","first-page":"6297","DOI":"10.1007\/s00784-021-03928-2","volume":"25","author":"M Schimmel","year":"2021","unstructured":"Schimmel M, Walther M, Al-Haj Husain N, Igarashi K, Wittneben J, Abou-Ayash S. Retention forces between primary and secondary CAD\/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations. Clin Oral Investig. 2021;25:6297\u2013307.","journal-title":"Clin Oral Investig"}],"container-title":["Journal of Materials Science: Materials in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-025-06891-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10856-025-06891-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10856-025-06891-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T20:02:03Z","timestamp":1767643323000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10856-025-06891-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,14]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["6891"],"URL":"https:\/\/doi.org\/10.1007\/s10856-025-06891-6","relation":{},"ISSN":["1573-4838"],"issn-type":[{"value":"1573-4838","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,14]]},"assertion":[{"value":"23 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"40"}}