{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T11:57:56Z","timestamp":1715687876864},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2006,12,19]],"date-time":"2006-12-19T00:00:00Z","timestamp":1166486400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2006,12,19]],"date-time":"2006-12-19T00:00:00Z","timestamp":1166486400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2007,4]]},"DOI":"10.1007\/s10877-006-9060-x","type":"journal-article","created":{"date-parts":[[2006,12,18]],"date-time":"2006-12-18T10:32:47Z","timestamp":1166437967000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Assessment of a new prototype hydrogel CO\n                2\n               sensor; comparison with air tonometry"],"prefix":"10.1007","volume":"21","author":[{"given":"Rinze W.F.","family":"ter Steege","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastiaan","family":"Herber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wouter","family":"Olthuis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piet","family":"Bergveld","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert","family":"van den Berg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeroen J","family":"Kolkman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2006,12,19]]},"reference":[{"key":"9060_CR1","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1093\/oxfordjournals.bja.a013386","volume":"84","author":"JJ Kolkman","year":"2000","unstructured":"Kolkman JJ, Otte JA, Groeneveld AB (2000) Gastrointestinal luminal PCO2 tonometry: an update on physiology, methodology and clinical applications. Br J Anaesth 84:74\u201386","journal-title":"Br J Anaesth"},{"key":"9060_CR2","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1136\/gut.35.6.737","volume":"35","author":"JJ Kolkman","year":"1994","unstructured":"Kolkman JJ, Groeneveld AB, Meuwissen SG (1994) Effect of ranitidine on basal and bicarbonate enhanced intragastric pCO2: a tonometric study. Gut 35:737\u201341","journal-title":"Gut"},{"key":"9060_CR3","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1164\/ajrccm.163.5.2004057","volume":"163","author":"A Brinkmann","year":"2001","unstructured":"Brinkmann A, Glasbrenner B, Vlatten A, Eberhardt H, Geldner G, Radermacher P, Georgieff M, Wiedeck H (2001) Does gastric juice pH influence tonometric PCO2 measured by automated air tonometry?. Am J Respir Crit Care Med 163:1150\u20132","journal-title":"Am J Respir Crit Care Med"},{"key":"9060_CR4","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1016\/S1542-3565(05)00155-2","volume":"3","author":"JA Otte","year":"2005","unstructured":"Otte JA, Geelkerken RH, Oostveen E, Mensink PB, Huisman AB, Kolkman JJ (2005) Clinical impact of gastric exercise tonometry on diagnosis and management of chronic gastrointestinal ischemia. Clin Gastroenterol Hepatol 3:660\u20136","journal-title":"Clin Gastroenterol Hepatol"},{"key":"9060_CR5","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1097\/00024382-200115050-00005","volume":"15","author":"P Wall","year":"2001","unstructured":"Wall P, Henderson L, Buising C, Rickers T, Cardenas A, Mattson T, Larkin AL, Wittkopf L, Davis D, Raymond F, Timberlake G, Moorman D, Paradise N (2001) Monitoring gastrointestinal intraluminal PCO2: problems with airflow methods. Shock 15:360\u20135","journal-title":"Shock"},{"key":"9060_CR6","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1097\/00024382-200208000-00018","volume":"18","author":"R Vincent","year":"2002","unstructured":"Vincent R, Freeman B, Weatherford E, Henderson L, Buising C, Wall P (2002) Airflow-based pCO2 monitoring delivers O2 and removes CO2 from the monitored environment. Shock 18:193\u2013194","journal-title":"Shock"},{"key":"9060_CR7","doi-asserted-by":"crossref","unstructured":"Herber S, Bomer J, Bergveld P, van den Berg A. A miniaturized carbon dioxide gas sensor based on sensing of pH-sensitive hydrogel swelling with a pressure sensor. Biomed Microdevices (2005); 7(3)","DOI":"10.1007\/s10544-005-3026-5"},{"key":"9060_CR8","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1152\/jappl.2001.91.2.866","volume":"91","author":"JA Otte","year":"2001","unstructured":"Otte JA, Oostveen E, Geelkerken RH, Groeneveld AB, Kolkman JJ (2001) Exercise induces gastric ischemia in healthy volunteers: a tonometry study. J Appl Physiol 91:866\u2013871","journal-title":"J Appl Physiol"},{"key":"9060_CR9","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1164\/ajrccm.153.2.8564119","volume":"153","author":"JA Guzman","year":"1996","unstructured":"Guzman JA, Kruse JA (1996) Development and validation of a technique for continuous monitoring of gastric intramucosal pH. Am J Respir Crit Care Med 153:694\u2013700","journal-title":"Am J Respir Crit Care Med"},{"key":"9060_CR10","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1097\/00000539-199607000-00003","volume":"83","author":"G Knichwitz","year":"1996","unstructured":"Knichwitz G, Rotker J, Brussel T, Kuhmann M, Mertes N, Mollhoff T (1996) A new method for continuous intramucosal pCO2 measurement in the gastrointestinal tract. Anesth Analg 83:6\u201311","journal-title":"Anesth Analg"},{"key":"9060_CR11","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1023\/A:1007335622132","volume":"13","author":"JJ Kolkman","year":"1997","unstructured":"Kolkman JJ, Zwaarekant LJ, Boshuizen K, Groeneveld AB, Meuwissen SG (1997) In vitro evaluation of intragastric PCO2 measurement by air tonometry. J Clin Monit 13:115\u2013119","journal-title":"J Clin Monit"},{"key":"9060_CR12","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1177\/0310057X9802600106","volume":"26","author":"B Venkatesh","year":"1998","unstructured":"Venkatesh B, Morgan J, Jones RD, Clague A (1998) Validation of air as an equilibration medium in gastric tonometry: an in vitro evaluation of two techniques for measuring air Pco2. Anaesth Intensive Care 26:46\u201350","journal-title":"Anaesth Intensive Care"},{"key":"9060_CR13","doi-asserted-by":"crossref","first-page":"1896","DOI":"10.1109\/T-ED.1979.19793","volume":"26","author":"WH Ko","year":"1979","unstructured":"Ko WH, Hynecek J. Boettcher SF Development of a miniature pressure transducer for biomedical applications. IEEE transactions of electron devices (1979); 26: 1896\u20131906","journal-title":"IEEE transactions of electron devices"},{"key":"9060_CR14","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1053\/jcan.2002.124138","volume":"16","author":"MV Chapman","year":"2002","unstructured":"Chapman MV, Woolf RL, Bennett-Guerrero E, Mythen MG (2002) The effect of hypothermia on calculated values using saline and automated air tonometry. J Cardiothorac Vasc Anesth 16:304\u2013307","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"9060_CR15","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1111\/j.1365-2044.2005.04216.x","volume":"60","author":"M Weiss","year":"2005","unstructured":"Weiss M, Dullenkopf A, Hasenclever P (2005) Performance of automated air tonometry under hypothermia. Anaesthesia 60:705\u2013707","journal-title":"Anaesthesia"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-006-9060-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-006-9060-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-006-9060-x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-006-9060-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:07Z","timestamp":1693518907000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-006-9060-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,12,19]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2007,4]]}},"alternative-id":["9060"],"URL":"https:\/\/doi.org\/10.1007\/s10877-006-9060-x","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,12,19]]},"assertion":[{"value":"4 August 2006","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 October 2006","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2006","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"83"}}