{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T16:26:15Z","timestamp":1783700775038,"version":"3.55.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2010,3,13]],"date-time":"2010-03-13T00:00:00Z","timestamp":1268438400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2010,4]]},"DOI":"10.1007\/s10877-010-9225-5","type":"journal-article","created":{"date-parts":[[2010,3,12]],"date-time":"2010-03-12T17:23:21Z","timestamp":1268414601000},"page":"155-159","source":"Crossref","is-referenced-by-count":7,"title":["Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide cardiography"],"prefix":"10.1007","volume":"24","author":[{"given":"Arunodaya R.","family":"Gujjar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Muralidhar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhijit","family":"Bhandopadhyaya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. N.","family":"Sathyaprabha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Janaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. K.","family":"Mahalla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ratan","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjay","family":"Banakal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. S.","family":"Jairaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2010,3,13]]},"reference":[{"key":"9225_CR1","doi-asserted-by":"crossref","unstructured":"Pulmonary Artery Catheter Consensus Conference Participants. Consensus statement. Crit Care Med 1997; 25: 910\u2013925.","DOI":"10.1097\/00003246-199706000-00006"},{"key":"9225_CR2","doi-asserted-by":"crossref","unstructured":"Aushah MR, Hasselblad V, Stevenson LW, Binanay C, O\u2019Connor CM, Sopko G, Califf RM. The impact of the pulmonary artery catheter in critically ill patients: meta analysis of randomized clinical trials. JAMA 2005; 294: 1664\u20131670.","DOI":"10.1001\/jama.294.13.1664"},{"key":"9225_CR3","doi-asserted-by":"crossref","first-page":"2338","DOI":"10.1097\/00003246-200210000-00025","volume":"30","author":"JC Chaney","year":"2002","unstructured":"Chaney JC, Derdak S. Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med. 2002;30:2338\u201345.","journal-title":"Crit Care Med"},{"key":"9225_CR4","first-page":"1227","volume":"99","author":"D Godkar","year":"2007","unstructured":"Godkar D, Bachu K, Dave B, Megna R, Niranjan S, Khanna A. Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement. J Natl Med Assoc. 2007;99:1227\u201334.","journal-title":"J Natl Med Assoc"},{"key":"9225_CR5","doi-asserted-by":"crossref","unstructured":"Ritchie JL, et al. ACC\/AHA guidelines for clinical use of radionuclide imaging: a report of the ACC\/AHA task force on practice guidelines. J Am Coll Cardiol 1995; 25: 521.","DOI":"10.1016\/0735-1097(95)90027-6"},{"key":"9225_CR6","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1378\/chest.114.6.1643","volume":"114","author":"WC Shoemaker","year":"1998","unstructured":"Shoemaker WC, Belzberg H, Wo CC, Milzman DP, Pasquale MD, Baga L, et al. Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. Chest. 1998;114:1643\u201352.","journal-title":"Chest"},{"key":"9225_CR7","doi-asserted-by":"crossref","unstructured":"Kubicek W, Patterson RP et al. Impedance cardiography as a non- invasive method of monitoring cardiac functions and other parameters of the cardiovascular system. Ann N Y Acad Sci 1970; 170: 724\u2013732.","DOI":"10.1111\/j.1749-6632.1970.tb17735.x"},{"key":"9225_CR8","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1097\/00003246-199906000-00053","volume":"27","author":"E Raaijmakers","year":"1999","unstructured":"Raaijmakers E, Faes TJC, Scholten RJPM, et al. A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med. 1999;27:1203\u201313.","journal-title":"Crit Care Med"},{"key":"9225_CR9","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s10877-008-9119-y","volume":"22","author":"AR Gujjar","year":"2008","unstructured":"Gujjar AR, Muralidhar K, Banakal S, Gupta R, Sathyaprabha TN, Jairaj PS. Non-invasive cardiac output by Thoracic Electrical Bioimpedance in post-cardiac surgery patients: comparison with thermodilution method. J Clin Monit Comput. 2008;22:175\u201380.","journal-title":"J Clin Monit Comput"},{"key":"9225_CR10","volume-title":"An introduction to impedance cardio-vasography","author":"GD Jindal","year":"2001","unstructured":"Jindal GD, Ananthakrishnan TS, Kataria SK, Deshpande AK. An introduction to impedance cardio-vasography. Mumbai: Bhabha Atomic Research Council; 2001."},{"key":"9225_CR11","first-page":"450","volume":"31","author":"T Massardo","year":"1990","unstructured":"Massardo T, Gal RA, Grenier PT, et al. Left ventricular volume calculation using a count-based ratio method applied to multigated radionuclide angiography. J Nucl Med. 1990;31:450\u20136.","journal-title":"J Nucl Med"},{"key":"9225_CR12","doi-asserted-by":"crossref","first-page":"G26","DOI":"10.1016\/S1071-3581(96)90049-5","volume":"3","author":"American Society of Nuclear Cardiology","year":"1996","unstructured":"American Society of Nuclear Cardiology. Imaging guidelines for nuclear cardiology procedures: equilibrium gated blood pool imaging protocols. J Nucl Cardiol. 1996;3:G26\u20139.","journal-title":"J Nucl Cardiol"},{"key":"9225_CR13","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/S0140-6736(95)91748-9","volume":"346","author":"JM Bland","year":"1995","unstructured":"Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995;346:1085\u20137.","journal-title":"Lancet"},{"key":"9225_CR14","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85\u201391.","journal-title":"J Clin Monit Comput"},{"key":"9225_CR15","first-page":"151","volume":"51","author":"M Hartleb","year":"2000","unstructured":"Hartleb M, Rudzki K, Waluga M, Karpel E. Usefulness of thoracic electrical bioimpedance in detection of ejection fraction changes. J Physiol Pharmacol. 2000;51:151\u20139.","journal-title":"J Physiol Pharmacol"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-010-9225-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-010-9225-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-010-9225-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,31]],"date-time":"2019-05-31T04:19:53Z","timestamp":1559276393000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-010-9225-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3,13]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2010,4]]}},"alternative-id":["9225"],"URL":"https:\/\/doi.org\/10.1007\/s10877-010-9225-5","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3,13]]}}}