{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,20]],"date-time":"2025-09-20T19:17:38Z","timestamp":1758395858614},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,2,22]],"date-time":"2017-02-22T00:00:00Z","timestamp":1487721600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2018,2]]},"DOI":"10.1007\/s10877-017-0004-4","type":"journal-article","created":{"date-parts":[[2017,2,22]],"date-time":"2017-02-22T06:09:20Z","timestamp":1487743760000},"page":"133-140","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate"],"prefix":"10.1007","volume":"32","author":[{"given":"David","family":"Preiss","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin A.","family":"Drew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James","family":"Gosnell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bhavani S.","family":"Kodali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James H.","family":"Philip","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard D.","family":"Urman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,2,22]]},"reference":[{"key":"4_CR1","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1111\/j.1365-2044.1990.tb14833.x","volume":"45","author":"JG Jones","year":"1990","unstructured":"Jones JG, Sapsford DJ, Wheatley RG. Postoperative hypoxemia: mechanisms and time course. Anesthesia. 1990;45:566\u201373.","journal-title":"Anesthesia"},{"issue":"6","key":"4_CR2","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1007\/s00134-011-2210-8","volume":"37","author":"D Chiumello","year":"2011","unstructured":"Chiumello D, Chevallard G, Gregoreti C. Non-invasive ventilation in postoperative patients: A systematic review. Intensive Care Med. 2011;37(6):918\u201329.","journal-title":"Intensive Care Med"},{"key":"4_CR3","doi-asserted-by":"crossref","unstructured":"Taylor S, Kirton OC, Staff I, Kozol RA. Postoperative day one: a high risk period for respiratory events. Am J Surg. 2005;190:752\u20136.","DOI":"10.1016\/j.amjsurg.2005.07.015"},{"key":"4_CR4","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1164\/rccm.200408-1069OC","volume":"171","author":"FA McAlister","year":"2005","unstructured":"McAlister FA, Bertsch K, Man J, et al. Incidence of and risk factors for pulmonary complications after nonthoracic surgery. Am J Respir Crit Care Med. 2005;171:514\u20137.","journal-title":"Am J Respir Crit Care Med"},{"key":"4_CR5","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1378\/chest.99.4.923","volume":"99","author":"JC Hall","year":"1991","unstructured":"Hall JC, Tarala RA, Hall JL, Mander J. A multivariate analysis of the risk of pulmonary complications after laparotomy. Chest. 1991;99:923.","journal-title":"Chest"},{"key":"4_CR6","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1378\/chest.98.6.1388","volume":"98","author":"RM Schein","year":"1990","unstructured":"Schein RM, Hazday N, Pena M, Ruben BH, Sprung CL. Clinical antecedents to in-hospital cardiopulmonary arrest. Chest. 1990;98:1388\u201392.","journal-title":"Chest"},{"key":"4_CR7","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1097\/00043860-200610000-00010","volume":"13","author":"J Mailey","year":"2006","unstructured":"Mailey J, Digiovine B, Baillod D, Gnam G, Jordan J, Rubinfeld I. Reducing hospital standardized mortality rate with early interventions. J Trauma. Nursing. 2006;13:178\u201382.","journal-title":"J Trauma. Nursing"},{"key":"4_CR8","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1007\/BF02602761","volume":"10","author":"VA Lawrence","year":"1995","unstructured":"Lawrence VA, Hilsenbeck SG, Mulrow CD, et al. Incidence and hospital stay for cardiac and pulmonary complications after abdominal surgery. J Gen Intern Med. 1995;10:671.","journal-title":"J Gen Intern Med"},{"key":"4_CR9","unstructured":"Practice guidelines for post anesthetic care. A report by the American Society of Anesthesiologists Task Force on postanesthetic care. Anesthesiology. 2002;96:742\u201372."},{"key":"4_CR10","first-page":"31","volume-title":"Fourth Programme report, 1988\u20131989: ARI programme for control of acute respiratory infections","author":"World Health Organization","year":"1990","unstructured":"World Health Organization. Fourth Programme report, 1988\u20131989: ARI programme for control of acute respiratory infections. Geneva: WHO; 1990. p.\u00a031."},{"key":"4_CR11","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1378\/chest.87.5.577","volume":"78","author":"B Semmes","year":"1985","unstructured":"Semmes B, Tobin M, Snyder J, Grenvik A. Subjective and objective measurement of tidal volume in critically ill patients. Chest. 1985;78:577\u20139.","journal-title":"Chest"},{"issue":"1","key":"4_CR12","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.annemergmed.2004.06.016","volume":"45","author":"P Lovett","year":"2005","unstructured":"Lovett P, Buchwald J, Sturmann K, Bijur P. The vexations vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emerg Med. 2005;45(1):68\u201376.","journal-title":"Ann Emerg Med"},{"issue":"2","key":"4_CR13","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1093\/bja\/aer383","volume":"108","author":"A Gaucher","year":"2012","unstructured":"Gaucher A, Frasca D, Mimoz O, Debaene B. Accuracy of respiratory rate monitoring by capnometry using the Capnomask in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108(2):316\u201320.","journal-title":"Br J Anaesth"},{"issue":"9","key":"4_CR14","doi-asserted-by":"crossref","first-page":"489","DOI":"10.12968\/bjon.2006.15.9.21087","volume":"15","author":"J Hogan","year":"2006","unstructured":"Hogan J. Why don\u2019t nurses monitor the respiratory rates of patients? Br J Nurs. 2006;15(9):489\u201392.","journal-title":"Br J Nurs"},{"issue":"7","key":"4_CR15","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1097\/EJA.0b013e32833b1adf","volume":"27","author":"J Mellin-Olsen","year":"2010","unstructured":"Mellin-Olsen J, Staender S, Whitaker DK, Smith AF. The Helsinki declaration on patient safety in anaesthesiology. Eur J Anaesthesiol. 2010 Jul;27(7):592\u20137. doi: 10.1097\/EJA.0b013e32833b1adf .","journal-title":"Eur J Anaesthesiol"},{"key":"4_CR16","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1097\/EJA.0b013e32832bb68f","volume":"26","author":"L Vimlati","year":"2009","unstructured":"Vimlati L, Gilsanz F, Goldik Z. Quality and safety guidelines of postanaesthesia care: working party on post anaesthesia care (approvedby the European board and section of anaesthesiology, Union Europeenne des MedecinsSpecialistes). Eur J Anaesthesiol. 2009;26:715\u201321.","journal-title":"Eur J Anaesthesiol"},{"key":"4_CR17","unstructured":"Standards for Basic Anesthetic Monitoring. ASA House of Delegates on October 21, 1986, last ammended on October 20, 2010, and last affirmed on October 28, 2015."},{"issue":"1","key":"4_CR18","first-page":"69","volume":"117","author":"MA Ramsay","year":"2013","unstructured":"Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision, and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. AnesthAnalg. 2013;117(1):69\u201375.","journal-title":"AnesthAnalg"},{"issue":"2","key":"4_CR19","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1378\/chest.15-1369","volume":"149","author":"BS Nassar","year":"2016","unstructured":"Nassar BS, Schmidt GA. Capnography during Critical Illness. Chest. 2016;149(2):576\u201385.","journal-title":"Chest"},{"key":"4_CR20","doi-asserted-by":"publisher","unstructured":"Babaeizadeh S. Cost efficient accurate monitoring of respiration rate using ECG. Computing in Cardiology Conference, 2015. 18 February 2016. doi: 10.1109\/CIC.2015.7411084 .","DOI":"10.1109\/CIC.2015.7411084"},{"issue":"5","key":"4_CR21","first-page":"872","volume":"108","author":"O Mimoz","year":"2012","unstructured":"Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anesthesia. British. J Anesth. 2012;108(5):872\u20135.","journal-title":"J Anesth"},{"key":"4_CR22","first-page":"493","volume":"37","author":"E Jovanov","year":"2001","unstructured":"Jovanov E, Raskovic D, Hormigo R. Thermistor-based breathing sensor for circadian rhythm evaluation. Biomed Sci Instrument Conf Proc. 2001;37:493\u20137.","journal-title":"Biomed Sci Instrument Conf Proc"},{"issue":"4","key":"4_CR23","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1023\/A:1011424732717","volume":"16","author":"L Nilsson","year":"2000","unstructured":"Nilsson L, Johansson A, Kalman S. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique. J Clin Monit Comput. 2000;16(4):309\u201315.","journal-title":"J Clin Monit Comput"},{"key":"4_CR24","doi-asserted-by":"crossref","unstructured":"Ono Y, Mohamed D, Kobayashi M, Jen C. Piezoelectric membrane sensor and technique for breathing monitoring. Proceedings of IEEE Ultrasonics Symposium Conference Proceedings 2008, 795\u2013798.","DOI":"10.1109\/ULTSYM.2008.0191"},{"issue":"5","key":"4_CR25","doi-asserted-by":"crossref","first-page":"057001","DOI":"10.1117\/1.JBO.19.5.057001","volume":"19","author":"Z Chen","year":"2014","unstructured":"Chen Z, Lau D, Teo J, Ng S, Yang X, Kei P. Simultaneous measurement of breathing rate and heart rate using a microbend multimode fiber optic sensor. J Biomed Opt. 2014;19(5):057001.","journal-title":"J Biomed Opt"},{"key":"4_CR26","doi-asserted-by":"crossref","unstructured":"Boccanfuso L, O\u2019Kane J. Remote measurement of breathing rate in real time using a high precision, single-point infrared temperature sensor. Proceedings of the IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics; 2012, 1704\u20131709.","DOI":"10.1109\/BioRob.2012.6290703"},{"issue":"10","key":"4_CR27","doi-asserted-by":"crossref","first-page":"13167","DOI":"10.3390\/s121013167","volume":"12","author":"Z Zhang","year":"2012","unstructured":"Zhang Z, Zheng J, Wu H, Wang W, Wang B, Liu H. Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems. Sensors. 2012;12(10):13167\u201384.","journal-title":"Sensors"},{"key":"4_CR28","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1136\/emj.14.4.222","volume":"14","author":"CV Egleston","year":"1997","unstructured":"Egleston CV, Ben Aslam H, Lambert MA. Capnography for monitoring non-intubated spontaneously breathing patients in an emergency room setting. J AccidEmerg Med. 1997;14:222\u20134.","journal-title":"J AccidEmerg Med"},{"issue":"2","key":"4_CR29","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/BF01142280","volume":"10","author":"B Hok","year":"1993","unstructured":"Hok B, Wiklund L, Henneberg S. A new respiratory rate monitor: development and initial clinical experience. J Clin Monit Comput. 1993;10(2):101\u20137.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"4_CR30","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1002\/(SICI)1099-0496(199912)28:6<436::AID-PPUL9>3.0.CO;2-0","volume":"28","author":"T Manczur","year":"1999","unstructured":"Manczur T, Greenough A, Hooper R, Allen K, Latham S, Price JF, Rafferty GF. Tidal breathing parameters in young children: comparison of measurement by respiratory inductance plethysmography to a facemask, pneumotachograph system. Pediatr Pulmonol. 1999;28(6):436\u201341.","journal-title":"Pediatr Pulmonol"},{"issue":"5","key":"4_CR31","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1023\/A:1009967122272","volume":"15","author":"C Larsson","year":"1999","unstructured":"Larsson C, Staun P. Evaluation of a new fiber-optical monitor for respiratory rate monitoring. J Clin Monit Comput. 1999;15(5):295\u20138.","journal-title":"J Clin Monit Comput"},{"key":"4_CR32","unstructured":"Van Loon, K. Breteler MJ, Van Wolfwinkel L, RheineckLeyssius AT, Kossen S, Kalkman CJ, Van Zaane B, Peelen LM. Wireless non-invasive continous respiratory monitoring FMCW radar: a clinical validation study."},{"issue":"5","key":"4_CR33","first-page":"521","volume":"27","author":"V Hers","year":"2013","unstructured":"Hers, V, Corbugy D, Joslet I, Hermant P, Demarteau J, Delhougne B, Vandermoten G, Hermanne, JP. New Concept using Passive Infrared technolgoy for a contactless detection of breathing movement: a pilot study involving a cohort of 169 adult patients. J ClinMonitComput. 2013; 27(5): 521\u2013529.","journal-title":"J ClinMonitComput"},{"key":"4_CR34","unstructured":"Sathyamoorthy M, Lerman J, Feldman D, Feldman R, Moser J, Feldman U. Linsholm: A New Respiratory Monitor. ASA Abstract. San Francisco, USA, 2013: A5032."},{"issue":"10","key":"4_CR35","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.1007\/s12630-016-0694-y","volume":"63","author":"J Lerman","year":"2016","unstructured":"Lerman J, Feldman D, Feldman R, Moser J, Feldman L, Sathyamoorthy M, Deitch K, Feldman U. Linshom respiratory monitoring device: a novel temperature-based respiratory monitor. Can J Anaesth. 2016 Oct;63(10):1154\u201360.","journal-title":"Can J Anaesth"},{"key":"4_CR36","unstructured":"Standards for Basic Anesthetic Monitoring. American Society of Anesthesiologists Committee for Standards and Practice Parameters. Affirmed on 28 October 2015."},{"key":"4_CR37","unstructured":"Practice guidelines for postanesthetic care. An updated report by the ASA Task Force on post anesthetic care. Anesthesiology. 2014;118(2):1\u201317."},{"key":"4_CR38","unstructured":"National Association of State EMS Officials Medical Directors Council. National Model EMS Clinical Guidelines, 23 Oct 2014."},{"key":"4_CR39","doi-asserted-by":"crossref","unstructured":"Blankush JM, Freeman R, McIlvane J, Tran T, Nassani S, Leitman IM. Implementation of a novel postoperative monitoring system using automated modified early warnign scores (MEWS) incorporating end-tital capnography. J Clin Monit Comput 2016. Epub ahead of print.","DOI":"10.1007\/s10877-016-9943-4"},{"key":"4_CR40","unstructured":"Helfand M, Christensen V, Anderson J. Technology Assessment: Early Sense for Monitroing vital Signs in Hospitalized Patients. VA Evidence-based Synethesis Program Evidence Briefs [Internet]. Washington (DC): Department fo Veterans Affairs (US); 2011."},{"issue":"5","key":"4_CR41","doi-asserted-by":"crossref","first-page":"342","DOI":"10.7205\/MILMED.169.5.342","volume":"169","author":"K Tang","year":"2004","unstructured":"Tang K, Chiu J, Low E. Airway and ventilator equipment in field anesthesia: what\u2019s new? Mil Med. 2004;169(5):342\u20138.","journal-title":"Mil Med"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-017-0004-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-017-0004-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-017-0004-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:25Z","timestamp":1693518925000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-017-0004-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2,22]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["4"],"URL":"https:\/\/doi.org\/10.1007\/s10877-017-0004-4","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,22]]}}}