{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T22:42:39Z","timestamp":1789771359777,"version":"4.0.1"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,6,6]],"date-time":"2018-06-06T00:00:00Z","timestamp":1528243200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2019,4]]},"DOI":"10.1007\/s10877-018-0166-8","type":"journal-article","created":{"date-parts":[[2018,6,6]],"date-time":"2018-06-06T08:27:50Z","timestamp":1528273670000},"page":"269-279","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Measurement of blood-oxygen saturation using a photoacoustic technique in the rabbit hypoxemia model"],"prefix":"10.1007","volume":"33","author":[{"given":"Kiguna","family":"Sei","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masanori","family":"Fujita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeshi","family":"Hirasawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinpei","family":"Okawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihiro","family":"Kushibiki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidenori","family":"Sasa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Furuya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miya","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,6]]},"reference":[{"issue":"6","key":"166_CR1","doi-asserted-by":"publisher","first-page":"S5","DOI":"10.1213\/01.ane.0000278741.29274.e1","volume":"105","author":"J Toffaletti","year":"2007","unstructured":"Toffaletti J, Zijlstra WG. Misconceptions in reporting oxygen saturation. Anesth Analg. 2007;105(6):S5\u20139.","journal-title":"Anesth Analg"},{"issue":"3","key":"166_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/cc1489","volume":"6","author":"BV Scheer","year":"2002","unstructured":"Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6(3):1.","journal-title":"Crit Care"},{"issue":"4","key":"166_CR3","first-page":"S1-34","volume":"39","author":"NP O\u2019grady","year":"2011","unstructured":"O\u2019grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, et al. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control. 2011;39(4):S1-34.","journal-title":"Am J Infect Control"},{"issue":"6","key":"166_CR4","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1213\/01.ane.0000269514.31660.09","volume":"105","author":"JW Severinghaus","year":"2007","unstructured":"Severinghaus JW. Takuo Aoyagi: discovery of pulse oximetry. Anesth Analg. 2007;105(6):S1\u20134.","journal-title":"Anesth Analg"},{"issue":"1","key":"166_CR5","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1515\/jpm.2010.003","volume":"38","author":"J Hasegawa","year":"2010","unstructured":"Hasegawa J, Nakamura M, Matsuoka R, Mimura T, Ichizuka K, Sekizawa A, et al. Evaluation of placental function using near infrared spectroscopy during fetal growth restriction. J Perinat Med. 2010;38(1):29\u201332.","journal-title":"J Perinat Med"},{"key":"166_CR6","doi-asserted-by":"publisher","first-page":"22","DOI":"10.2174\/1875181401204010022","volume":"4","author":"J Kakogawa","year":"2012","unstructured":"Kakogawa J, Kanayama N. Application of near-infrared spectroscopy for the evaluation of placental oxygenation. Open Med Devices J. 2012;4:22\u20137.","journal-title":"Open Med Devices J"},{"issue":"2","key":"166_CR7","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/pd.4025","volume":"33","author":"A S\u00f8rensen","year":"2013","unstructured":"S\u00f8rensen A, Peters D, Simonsen C, Pedersen M, Stausb\u00f8l-Gr\u00f8n B, Christiansen OB, et al. Changes in human fetal oxygenation during maternal hyperoxia as estimated by BOLD MRI. Prenat Diagn. 2013;33(2):141\u20135.","journal-title":"Prenat Diagn"},{"key":"166_CR8","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.placenta.2015.12.018","volume":"39","author":"M Sinding","year":"2016","unstructured":"Sinding M, Peters DA, Fr\u00f8kj\u00e6r JB, Christiansen OB, Uldbjerg N, S\u00f8rensen A. Reduced placental oxygenation during subclinical uterine contractions as assessed by BOLD MRI. Placenta 2016;39:16\u201320.","journal-title":"Placenta"},{"issue":"4","key":"166_CR9","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1098\/rsfs.2011.0028","volume":"1","author":"P Beard","year":"2011","unstructured":"Beard P. Biomedical photoacoustic imaging. Interface Focus. 2011;1(4):602\u201331.","journal-title":"Interface Focus"},{"issue":"18","key":"166_CR10","doi-asserted-by":"publisher","first-page":"4409","DOI":"10.1088\/0031-9155\/50\/18\/011","volume":"50","author":"J Laufer","year":"2005","unstructured":"Laufer J, Elwell C, Delpy D, Beard P. In vitro measurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy: accuracy and resolution. Phys Med Biol. 2005;50(18):4409.","journal-title":"Phys Med Biol"},{"issue":"5","key":"166_CR11","doi-asserted-by":"publisher","first-page":"053901","DOI":"10.1063\/1.2435697","volume":"90","author":"HF Zhang","year":"2007","unstructured":"Zhang HF, Maslov K, Sivaramakrishnan M, Stoica G, Wang LV. Imaging of hemoglobin oxygen saturation variations in single vessels in vivo using photoacoustic microscopy. Appl Phys Lett. 2007;90(5):053901.","journal-title":"Appl Phys Lett"},{"key":"166_CR12","doi-asserted-by":"crossref","unstructured":"Ishihara M, Shinchib M, Horiguchi A, Shinmotoc H, Tsudad H, Irisawae K et al, editors Possibility of transrectal photoacoustic imaging-guided biopsy for detection of prostate cancer. Proc of SPIE Vol; 2017.","DOI":"10.1117\/12.2253277"},{"key":"166_CR13","doi-asserted-by":"crossref","unstructured":"M\u00e4rk J, Wagener A, P\u00f6nick S, Gr\u00f6tzinger C, Zhang E, Laufer J, editors Motion corrected photoacoustic difference imaging of fluorescent contrast agents. SPIE BiOS; 2016: International Society for Optics and Photonics.","DOI":"10.1117\/12.2207302"},{"issue":"2","key":"166_CR14","doi-asserted-by":"publisher","first-page":"87","DOI":"10.12968\/jowc.2016.25.2.87","volume":"25","author":"M Petri","year":"2016","unstructured":"Petri M, Stoffels I, Jose J, Leyh J, Schulz A, Dissemond J, et al. Photoacoustic imaging of real-time oxygen changes in chronic leg ulcers after topical application of a haemoglobin spray: a pilot study. J Wound Care. 2016;25(2):87\u201391.","journal-title":"J Wound Care"},{"issue":"4","key":"166_CR15","doi-asserted-by":"publisher","first-page":"4159","DOI":"10.1364\/OE.20.004159","volume":"20","author":"I Petrov","year":"2012","unstructured":"Petrov I, Petrov Y, Prough D, Cicenaite I, Deyo D, Esenaliev R. Optoacoustic monitoring of cerebral venous blood oxygenation though intact scalp in large animals. Opt Express. 2012;20(4):4159\u201367.","journal-title":"Opt Express"},{"issue":"5","key":"166_CR16","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1109\/TUFFC.2013.2646","volume":"60","author":"A Needles","year":"2013","unstructured":"Needles A, Heinmiller A, Sun J, Theodoropoulos C, Bates D, Hirson D, et al. Development and initial application of a fully integrated photoacoustic micro-ultrasound system. IEEE Trans Ultrason Ferroelectr Freq Control. 2013;60(5):888\u201397.","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"key":"166_CR17","doi-asserted-by":"crossref","unstructured":"Tzoumas S, Nunes A, Olefir I, Stangl S, Symvoulidis P, Glasl S, et al. Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues. arXiv preprint arXiv:151105846. 2015.","DOI":"10.1038\/ncomms12121"},{"issue":"2","key":"166_CR18","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.jss.2016.08.007","volume":"206","author":"K Sei","year":"2016","unstructured":"Sei K, Fujita M, Okawa S, Hirasawa T, Kushibiki T, Sasa H, et al. Appropriate timing of blood sampling for blood gas analysis in the ventilated rabbit. J Surg Res. 2016;206(2):325\u201336.","journal-title":"J Surg Res"},{"key":"166_CR19","doi-asserted-by":"publisher","first-page":"6525","DOI":"10.1038\/srep06525","volume":"4","author":"W Song","year":"2014","unstructured":"Song W, Wei Q, Liu W, Liu T, Yi J, Sheibani N, et al. A combined method to quantify the retinal metabolic rate of oxygen using photoacoustic ophthalmoscopy and optical coherence tomography. Sci Rep. 2014;4:6525.","journal-title":"Sci Rep"},{"issue":"7","key":"166_CR20","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1364\/OL.36.001029","volume":"36","author":"Y Wang","year":"2011","unstructured":"Wang Y, Hu S, Maslov K, Zhang Y, Xia Y, Wang LV. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure. Opt Lett. 2011;36(7):1029\u201331.","journal-title":"Opt Lett"},{"key":"166_CR21","unstructured":"Prahl S. Optical absorption of hemoglobin, vol.\u00a015. Oregon: Oregon Medical Laser Center; 1999. http:\/\/omlc.ogi.edu\/spectra\/hemoglobin\/index.html ."},{"issue":"4","key":"166_CR22","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1213\/ANE.0b013e31828610a0","volume":"117","author":"JR Feiner","year":"2013","unstructured":"Feiner JR, Rollins MD, Sall J, Eilers H, Au P, Bickler PE. Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia. Anesth Analg. 2013;117(4):847.","journal-title":"Anesth Analg"},{"issue":"2","key":"166_CR23","doi-asserted-by":"publisher","first-page":"299","DOI":"10.2217\/nnm.14.169","volume":"10","author":"W Li","year":"2015","unstructured":"Li W, Chen X. Gold nanoparticles for photoacoustic imaging. Nanomedicine 2015;10(2):299\u2013320.","journal-title":"Nanomedicine"},{"key":"166_CR24","first-page":"rsfs20110028","volume":"2011","author":"P Beard","year":"2011","unstructured":"Beard P. Biomedical photoacoustic imaging. Interface Focus. 2011;2011:rsfs20110028.","journal-title":"Interface Focus"},{"issue":"3","key":"166_CR25","doi-asserted-by":"publisher","first-page":"0360121","DOI":"10.1117\/1.JBO.17.3.036012","volume":"17","author":"Y Jiang","year":"2012","unstructured":"Jiang Y, Forbrich A, Harrison T, Zemp RJ. Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study. J Biomed Opt. 2012;17(3):0360121\u20138.","journal-title":"J Biomed Opt"},{"issue":"4","key":"166_CR26","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1093\/ilar.31.4.5","volume":"31","author":"MW McGuill","year":"1989","unstructured":"McGuill MW, Rowan AN. Biological effects of blood loss: implications for sampling volumes and techniques. ILAR J. 1989;31(4):5\u201320.","journal-title":"ILAR J"},{"key":"166_CR27","volume-title":"Recommended methodology for using WHO international reference preparations for thromboplastin","author":"World Health Organization","year":"1983","unstructured":"World Health Organization. Recommended methodology for using WHO international reference preparations for thromboplastin. Geneva: World Health Organization; 1983."},{"issue":"20","key":"166_CR28","doi-asserted-by":"crossref","first-page":"12609","DOI":"10.1016\/S0021-9258(18)90790-8","volume":"259","author":"K Vandegriff","year":"1984","unstructured":"Vandegriff K, Olson J. The kinetics of O2 release by human red blood cells in the presence of external sodium dithionite. J Biol Chem. 1984;259(20):12609\u201318.","journal-title":"J Biol Chem"},{"issue":"3","key":"166_CR29","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1002\/lsm.20285","volume":"38","author":"M Ishihara","year":"2006","unstructured":"Ishihara M, Sato M, Kaneshiro N, Mitani G, Sato S, Mochida J, et al. Development of a diagnostic system for osteoarthritis using a photoacoustic measurement method. Lasers Surg Med. 2006;38(3):249\u201355.","journal-title":"Lasers Surg Med"},{"issue":"1","key":"166_CR30","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1530\/REP-12-0091","volume":"144","author":"B Fischer","year":"2012","unstructured":"Fischer B, Chavatte-Palmer P, Viebahn C, Santos AN, Duranthon V. Rabbit as a reproductive model for human health. Reproduction 2012;144(1):1\u201310.","journal-title":"Reproduction"},{"issue":"4","key":"166_CR31","first-page":"395","volume":"40","author":"N Lipman","year":"1990","unstructured":"Lipman N, Marini R, Erdman S. A comparison of ketamine\/xylazine and ketamine\/xylazine\/acepromazine anesthesia in the rabbit. Lab Anim Sci. 1990;40(4):395\u20138.","journal-title":"Lab Anim Sci"},{"issue":"3","key":"166_CR32","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1152\/ajplegacy.1939.125.3.521","volume":"125","author":"RC Lee","year":"1939","unstructured":"Lee RC. The rectal temperature of the normal rabbit. Am J Physiol Legacy Content. 1939;125(3):521\u20139.","journal-title":"Am J Physiol Legacy Content"},{"issue":"3","key":"166_CR33","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1213\/00000539-199903000-00034","volume":"88","author":"KS Kim","year":"1999","unstructured":"Kim KS, Shim JC, Jun JH, Lee KH, Chung CW. Rabbits treated with chronic isepamicin are resistant to mivacurium and rocuronium. Anesth Analg. 1999;88(3):654\u20138.","journal-title":"Anesth Analg"},{"issue":"1","key":"166_CR34","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.joms.2009.04.040","volume":"68","author":"Y Terakawa","year":"2010","unstructured":"Terakawa Y, Ichinohe T, Kaneko Y. Rocuronium and vecuronium do not affect mandibular bone marrow and masseter muscular blood flow in rabbits. J Oral Maxillofacial Surg. 2010;68(1):15\u201320.","journal-title":"J Oral Maxillofacial Surg"},{"issue":"3","key":"166_CR35","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1152\/jappl.1967.22.3.453","volume":"22","author":"WR Stahl","year":"1967","unstructured":"Stahl WR. Scaling of respiratory variables in mammals. J Appl Physiol. 1967;22(3):453\u201360.","journal-title":"J Appl Physiol"},{"issue":"6","key":"166_CR36","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.1152\/jappl.1960.15.6.1069","volume":"15","author":"JE Drorbaugh","year":"1960","unstructured":"Drorbaugh JE. Pulmonary function in different animals. J Appl Physiol. 1960;15(6):1069\u201372.","journal-title":"J Appl Physiol"},{"issue":"4","key":"166_CR37","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1213\/00000539-199810000-00036","volume":"87","author":"DW Lowry","year":"1998","unstructured":"Lowry DW, Mirakhur RK, McCarthy GJ, Carroll MT, McCourt KC. Neuromuscular effects of rocuronium during sevoflurane, isoflurane, and intravenous anesthesia. Anesth Analg. 1998;87(4):936\u201340.","journal-title":"Anesth Analg"},{"issue":"3","key":"166_CR38","first-page":"579","volume":"36","author":"J Kiel","year":"1995","unstructured":"Kiel J, Van Heuven W. Ocular perfusion pressure and choroidal blood flow in the rabbit. Investig Ophthalmol Vis Sci. 1995;36(3):579\u201385.","journal-title":"Investig Ophthalmol Vis Sci"},{"issue":"4","key":"166_CR39","first-page":"328","volume":"43","author":"G Aeschbacher","year":"1993","unstructured":"Aeschbacher G, Webb A. Propofol in rabbits. 2. Long-term anesthesia. Lab Anim Sci. 1993;43(4):328\u201335.","journal-title":"Lab Anim Sci"},{"key":"166_CR40","doi-asserted-by":"crossref","unstructured":"Shah PS, Shah VS. Continuous heparin infusion to prevent thrombosis and catheter occlusion in neonates with peripherally placed percutaneous central venous catheters. Cochrane Library. 2008; CD002772.","DOI":"10.1002\/14651858.CD002772.pub3"},{"issue":"2","key":"166_CR41","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.rvsc.2009.02.003","volume":"87","author":"A Zotti","year":"2009","unstructured":"Zotti A, Banzato T, Cozzi B. Cross-sectional anatomy of the rabbit neck and trunk: comparison of computed tomography and cadaver anatomy. Res Vet Sci. 2009;87(2):171\u20136.","journal-title":"Res Vet Sci"},{"issue":"8476","key":"166_CR42","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"327","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;327(8476):307\u201310.","journal-title":"Lancet"},{"issue":"2","key":"166_CR43","first-page":"223","volume":"19","author":"SK Hanneman","year":"2008","unstructured":"Hanneman SK. Design, analysis and interpretation of method-comparison studies. AACN Adv Crit Care. 2008;19(2):223.","journal-title":"AACN Adv Crit Care"},{"key":"166_CR44","volume-title":"Laser Institute of America, American National Standard for Safe Use of Lasers ANSI Z136.1-2014","author":"American National Standards Institute","year":"2014","unstructured":"American National Standards Institute. Laser Institute of America, American National Standard for Safe Use of Lasers ANSI Z136.1-2014. New York: American National Standards Institute; 2014."},{"issue":"3","key":"166_CR45","doi-asserted-by":"publisher","first-page":"289","DOI":"10.7150\/thno.10155","volume":"5","author":"S Mallidi","year":"2015","unstructured":"Mallidi S, Watanabe K, Timerman D, Schoenfeld D, Hasan T. Prediction of tumor recurrence and therapy monitoring using ultrasound-guided photoacoustic imaging. Theranostics 2015;5(3):289\u2013301.","journal-title":"Theranostics"},{"issue":"4","key":"166_CR46","doi-asserted-by":"publisher","first-page":"iii","DOI":"10.1038\/nmeth.f.381","volume":"12","author":"M Lakshman","year":"2015","unstructured":"Lakshman M, Needles A. Screening and quantification of the tumor microenvironment with micro-ultrasound and photoacoustic imaging. Nat Methods. 2015;12(4):iii\u2013v.","journal-title":"Nat Methods"},{"issue":"22","key":"166_CR47","doi-asserted-by":"publisher","first-page":"4722","DOI":"10.1364\/AO.41.004722","volume":"41","author":"RO Esenaliev","year":"2002","unstructured":"Esenaliev RO, Larina IV, Larin KV, Deyo DJ, Motamedi M, Prough DS. Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study. Appl Opt. 2002;41(22):4722\u201331.","journal-title":"Appl Opt"},{"issue":"1","key":"166_CR48","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1088\/0031-9155\/52\/1\/010","volume":"52","author":"J Laufer","year":"2006","unstructured":"Laufer J, Delpy D, Elwell C, Beard P. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration. Phys Med Biol. 2006;52(1):141.","journal-title":"Phys Med Biol"},{"issue":"31","key":"166_CR49","doi-asserted-by":"publisher","first-page":"7410","DOI":"10.1364\/AO.37.007410","volume":"37","author":"M Hammer","year":"1998","unstructured":"Hammer M, Schweitzer D, Michel B, Thamm E, Kolb A. Single scattering by red blood cells. Appl Opt. 1998;37(31):7410\u20138.","journal-title":"Appl Opt"},{"issue":"6","key":"166_CR50","doi-asserted-by":"publisher","first-page":"065001","DOI":"10.1117\/1.3516722","volume":"15","author":"D Sakota","year":"2010","unstructured":"Sakota D, Takatani S. Photon-cell interactive Monte Carlo model based on the geometric optics theory for photon migration in blood by incorporating both extra-and intracellular pathways. J Biomed Opt. 2010;15(6):065001\u201314.","journal-title":"J Biomed Opt"},{"issue":"5","key":"166_CR51","doi-asserted-by":"publisher","first-page":"N91","DOI":"10.1088\/0031-9155\/51\/5\/N02","volume":"51","author":"L Kocsis","year":"2006","unstructured":"Kocsis L, Herman P, Eke A. The modified Beer\u2013Lambert law revisited. Phys Med Biol. 2006;51(5):N91.","journal-title":"Phys Med Biol"},{"issue":"1","key":"166_CR52","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1117\/1.429919","volume":"4","author":"M Friebel","year":"1999","unstructured":"Friebel M, Do K, Hahn A, Mu G. Optical properties of circulating human blood in the wavelength range 400\u20132500 nm. J Biomed Opt. 1999;4(1):36\u201346.","journal-title":"J Biomed Opt"},{"issue":"2","key":"166_CR53","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1007\/BF01616919","volume":"9","author":"KJ Reynolds","year":"1993","unstructured":"Reynolds KJ, Palayiwa E, Moyle JT, Sykes MK, Hahn CE. The effect of dyshemoglobins on pulse oximetry: part I, theoretical approach and part II, experimental results using an in vitro test system. J Clin Monitor. 1993;9(2):81\u201390.","journal-title":"J Clin Monitor"},{"issue":"1","key":"166_CR54","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/S0034-5288(02)00065-6","volume":"73","author":"P Verwaerde","year":"2002","unstructured":"Verwaerde P, Malet C, Lagente M, De La Farge F, Braun J. The accuracy of the i-STAT portable analyser for measuring blood gases and pH in whole-blood samples from dogs. Res Vet Sci. 2002;73(1):71\u20135.","journal-title":"Res Vet Sci"},{"issue":"9","key":"166_CR55","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1093\/clinchem\/37.9.1633","volume":"37","author":"W Zijlstra","year":"1991","unstructured":"Zijlstra W, Buursma A, Meeuwsen-Van der Roest W. Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. Clin Chem. 1991;37(9):1633\u20138.","journal-title":"Clin Chem"},{"issue":"4","key":"166_CR56","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1152\/jappl.1994.77.4.2018","volume":"77","author":"A Agusti","year":"1994","unstructured":"Agusti A, Roca J, Barbera J, Casademont J, Rodriguez-Roisin R, Wagner P. Effect of sampling site on femoral venous blood gas values. J Appl Physiol. 1994;77(4):2018\u201322.","journal-title":"J Appl Physiol"},{"issue":"4","key":"166_CR57","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1213\/ANE.0000000000000145","volume":"118","author":"S Ogoh","year":"2014","unstructured":"Ogoh S, Sato K, Okazaki K, Miyamoto T, Secher F, S\u00f8rensen H, et al. A decrease in spatially resolved near-infrared spectroscopy-determined frontal lobe tissue oxygenation by phenylephrine reflects reduced skin blood flow. Anesth Analg. 2014;118(4):823\u20139.","journal-title":"Anesth Analg"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0166-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-018-0166-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0166-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:29Z","timestamp":1693518929000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-018-0166-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,6]]},"references-count":57,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["166"],"URL":"https:\/\/doi.org\/10.1007\/s10877-018-0166-8","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,6]]},"assertion":[{"value":"15 June 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declare that they have no conflict of interest to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The experimental protocol used in this study was approved by the Institutional Review Board on Animal Care of National Defense Medical College, Japan (Approval number; 13091).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}