{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T04:09:14Z","timestamp":1744258154892,"version":"3.40.4"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,7,30]],"date-time":"2018-07-30T00:00:00Z","timestamp":1532908800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2018,7,30]],"date-time":"2018-07-30T00:00:00Z","timestamp":1532908800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2019,6,1]]},"DOI":"10.1007\/s10877-018-0188-2","type":"journal-article","created":{"date-parts":[[2018,7,30]],"date-time":"2018-07-30T11:00:34Z","timestamp":1532948434000},"page":"431-435","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Reliability of cuff pressure gauges"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5019-3275","authenticated-orcid":false,"given":"Julien","family":"Raft","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anne-Sophie","family":"Lamotte","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruno","family":"Maury","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabelle","family":"Clerc-Urm\u00e8s","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9dric","family":"Baumann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"Richeb\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Herv\u00e9","family":"Bouaziz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,7,30]]},"reference":[{"key":"188_CR1","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s10877-011-9333-x","volume":"26","author":"S Efrati","year":"2012","unstructured":"Efrati S, Deutsch I, Gurman GM. Endotracheal tube cuff-small important part of a big issue. J Clin Monit Comput. 2012;26:53\u201360.","journal-title":"J Clin Monit Comput"},{"key":"188_CR2","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1136\/bmj.288.6422.965","volume":"288","author":"RD Seegobin","year":"1984","unstructured":"Seegobin RD, Van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. Br Med J. 1984;288:965\u20138.","journal-title":"Br Med J"},{"key":"188_CR3","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/0002-9610(77)90008-3","volume":"133","author":"P Dobrin","year":"1977","unstructured":"Dobrin P, Canfield T. Cuffed endotracheal tubes: mucosal pressures and tracheal wall blood flow. Am J Surg. 1977;133:562\u20138.","journal-title":"Am J Surg"},{"key":"188_CR4","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1111\/j.1399-6576.1977.tb01198.x","volume":"21","author":"U Nordin","year":"1977","unstructured":"Nordin U, Lindholm CE, Wolgast M. Blood flow in the rabbit tracheal mucosa under normal conditions and under the influence of tracheal intubation. Acta Anaesthesiol Scand. 1977;21:81\u201394.","journal-title":"Acta Anaesthesiol Scand"},{"key":"188_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2253-10-20","author":"K Rokamp","year":"2000","unstructured":"Rokamp K, Secher N, M\u00f8ller A, Nielson H. Tracheal tube and laryngeal mask cuff pressure during anaesthesia\u2014mandatory monitoring is in need. BMC Anesthesiol. 2000. https:\/\/doi.org\/10.1186\/1471-2253-10-20.","journal-title":"BMC Anesthesiol"},{"key":"188_CR6","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.1097\/00000542-200111000-00015","volume":"95","author":"X Combes","year":"2001","unstructured":"Combes X, Schauvliege F, Peyrouset O, Motamed C, Kirov K, Dhonneur G, Duvaldestin P. Intracuff pressure and tracheal morbidity: influence of filling with saline during nitrous oxide anesthesia. Anesthesiology. 2001;95:1120\u20134.","journal-title":"Anesthesiology"},{"key":"188_CR7","unstructured":"D\u00e9cret s\u00e9curit\u00e9 - 8\/12\/1994 - Soci\u00e9t\u00e9 Fran\u00e7aise d\u2019Anesth\u00e9sie et r\u00e9animation - Sfar. http:\/\/sfar.org\/decret-securite-8121994\/. Accessed 16 Mar 2018."},{"key":"188_CR8","unstructured":"Prise en charge des voies a\u00e9riennes en anesth\u00e9sie adulte \u00e0 l\u2019exception de l\u2019intubation difficile - Sfar. http:\/\/sfar.org\/prise-en-charge-des-voies-aeriennes-en-anesthesie-adulte-a-lexception-de-lintubation-difficile\/. Accessed 16 Mar 2018."},{"key":"188_CR9","unstructured":"Texte de la directive dispositifs m\u00e9dicaux 93\/42\/CE - LNE. http:\/\/www.lne.fr\/publications\/directives\/93-42.pdf. Accessed 31 Mar 2018."}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0188-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-018-0188-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0188-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T05:33:10Z","timestamp":1744176790000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-018-0188-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,30]]},"references-count":9,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,6,1]]}},"alternative-id":["188"],"URL":"https:\/\/doi.org\/10.1007\/s10877-018-0188-2","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"type":"print","value":"1387-1307"},{"type":"electronic","value":"1573-2614"}],"subject":[],"published":{"date-parts":[[2018,7,30]]},"assertion":[{"value":"4 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Julien Raft, Anne-Sophie Lamotte, Bruno Maury, Isabelle Clerc-Urm\u00e8s, C\u00e9dric Baumann, and Herv\u00e9 Bouaziz declared no conflict of interest. Philippe Richeb\u00e9: Honorarium as a consultant for the following companies: Medasense, Abbvie, Medtronic-Covidien, Biosyent, Merck. Member of the Scientific Advisory board of Medasense LTD since 2014.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}