{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:56:19Z","timestamp":1792029379002,"version":"4.4.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2018,8,11]],"date-time":"2018-08-11T00:00:00Z","timestamp":1533945600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81401485"],"award-info":[{"award-number":["81401485"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2019,6]]},"DOI":"10.1007\/s10877-018-0192-6","type":"journal-article","created":{"date-parts":[[2018,8,11]],"date-time":"2018-08-11T06:20:34Z","timestamp":1533968434000},"page":"437-444","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Tracheal sounds accurately detect apnea in patients recovering from anesthesia"],"prefix":"10.1007","volume":"33","author":[{"given":"Jing","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunyu","family":"Ai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bowen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lara M.","family":"Brewer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chien-Kun","family":"Ting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Desheng","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2672-0116","authenticated-orcid":false,"given":"Lu","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,8,11]]},"reference":[{"key":"192_CR1","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s10877-016-9841-9","volume":"31","author":"C Voscopoulos","year":"2017","unstructured":"Voscopoulos C, Theos K, Tillmann HHA, George E. A risk stratification algorithm using non-invasive respiratory volume monitoring to improve safety when using post-operative opioids in the PACU. J Clin Monit Comput. 2017;31:417\u201326.","journal-title":"J Clin Monit Comput"},{"key":"192_CR2","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1097\/ALN.0b013e3181c38c25","volume":"112","author":"A Dahan","year":"2010","unstructured":"Dahan A, Aarts L, Smith TW. Incidence, reversal, and prevention of opioid-induced respiratory depression. Anesthesiology. 2010;112:226\u201338.","journal-title":"Anesthesiology"},{"key":"192_CR3","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1097\/ALN.0b013e3181b060b6","volume":"111","author":"Y Kasuya","year":"2009","unstructured":"Kasuya Y, Ak\u00e7a O, Sessler DI, Ozaki M, Komatsu R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology. 2009;111:609\u201315.","journal-title":"Anesthesiology"},{"key":"192_CR4","doi-asserted-by":"publisher","first-page":"157","DOI":"10.2146\/ajhp050194","volume":"63","author":"RR Maddox","year":"2006","unstructured":"Maddox RR, Williams CK, Oglesby H, Butler B, Colclasure B. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion system. Am J Health Syst Pharm. 2006;63:157\u201364.","journal-title":"Am J Health Syst Pharm"},{"key":"192_CR5","doi-asserted-by":"publisher","first-page":"47","DOI":"10.5055\/jom.2010.0004","volume":"6","author":"JA George","year":"2010","unstructured":"George JA, Lin EE, Hanna MN, Murphy JD, Kumar K, et al. The effect of intravenous opioid patient-controlled analgesia with and without background infusion on respiratory depression: a meta-analysis. J Opioid Manag. 2010;6:47\u201354.","journal-title":"J Opioid Manag"},{"key":"192_CR6","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1213\/01.ane.0000269489.26048.63","volume":"105","author":"FJ Overdyk","year":"2007","unstructured":"Overdyk FJ, Carter R, Maddox RR, Callura J, Herrin AE, Henriquez C. Continuous oximetry\/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia. Anesth Analg. 2007;105:412.","journal-title":"Anesth Analg"},{"key":"192_CR7","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.jclinane.2010.08.012","volume":"23","author":"JB Waugh","year":"2011","unstructured":"Waugh JB, Epps CA, Khodneva YA. Capnography enhances surveillance of respiratory events during procedural sedation: a meta-analysis. J Clin Anesth. 2011;23:189\u201396.","journal-title":"J Clin Anesth"},{"key":"192_CR8","volume-title":"Miller\u2019s anesthesia","author":"RD Miller","year":"2015","unstructured":"Miller RD, Cohen NH, Eriksson LI, Fleisher LA, et al. (2015). Miller\u2019s anesthesia. Philadelphia: Elsevier\/Saunders."},{"key":"192_CR9","doi-asserted-by":"publisher","first-page":"489","DOI":"10.12968\/bjon.2006.15.9.21087","volume":"15","author":"J Hogan","year":"2006","unstructured":"Hogan J. Why don\u2019t nurses monitor the respiratory rates of patients. Br J Nurs. 2006;15:489\u201392.","journal-title":"Br J Nurs"},{"key":"192_CR10","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.annemergmed.2004.06.016","volume":"45","author":"PB Lovett","year":"2005","unstructured":"Lovett PB, Buchwald JM, Kai S, Bijur P. The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emerg Med. 2005;45:68\u201376.","journal-title":"Ann Emerg Med"},{"key":"192_CR11","doi-asserted-by":"publisher","first-page":"1552","DOI":"10.1378\/chest.126.5.1552","volume":"126","author":"ES Fu","year":"2004","unstructured":"Fu ES, Downs JB, Schweiger JW, Miguel RV, Smith RA. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126:1552.","journal-title":"Chest"},{"key":"192_CR12","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1542\/peds.2007-2385","volume":"122","author":"I Keidan","year":"2008","unstructured":"Keidan I, Gravenstein D, Berkenstadt H, Ziv A, Shavit I, Sidi A. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122:293\u20138.","journal-title":"Pediatrics"},{"key":"192_CR13","doi-asserted-by":"publisher","first-page":"86","DOI":"10.4321\/S1130-01082010000200003","volume":"102","author":"G Cacho","year":"2010","unstructured":"Cacho G, P\u00e9rez-Calle JL, Barbado A, Lled\u00f3 JL, Ojea R, Fern\u00e1ndez-Rodr\u00edguez CM. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy. Rev Esp Enferm Dig. 2010;102:86\u20139.","journal-title":"Rev Esp Enferm Dig"},{"key":"192_CR14","doi-asserted-by":"publisher","first-page":"1166","DOI":"10.1111\/pan.12221","volume":"23","author":"M Patino","year":"2013","unstructured":"Patino M, Redford DT, Quigley TW, Mahmoud M, Kurth CD, Szmuk P. Accuracy of acoustic respiration rate monitoring in pediatric patients. Paediatr Anaesth. 2013;23:1166\u201373.","journal-title":"Paediatr Anaesth"},{"key":"192_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/BF02078136","volume":"12","author":"RH Friesen","year":"1996","unstructured":"Friesen RH, Alswang M. End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error. J Clin Monit Comput. 1996;12:155\u20139.","journal-title":"J Clin Monit Comput"},{"key":"192_CR16","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1093\/bja\/aer383","volume":"108","author":"A Gaucher","year":"2012","unstructured":"Gaucher A, Frasca D, Mimoz O, Debaene B. Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316\u201320.","journal-title":"Br J Anaesth"},{"key":"192_CR17","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1093\/bja\/aer153","volume":"107","author":"GB Drummond","year":"2011","unstructured":"Drummond GB, Bates A, Mann J, Arvind DK. Validation of a new non-invasive automatic monitor of respiratory rate for postoperative subjects. Br J Anaesth. 2011;107:462\u20139.","journal-title":"Br J Anaesth"},{"key":"192_CR18","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1136\/adc.2007.118513","volume":"93","author":"N Nassi","year":"2008","unstructured":"Nassi N, Piumelli R, Lombardi E, Landini L, Donzelli G, De MM. Comparison between pulse oximetry and transthoracic impedance alarm traces during home monitoring. Arch Dis Child. 2008;93:126\u201332.","journal-title":"Arch Dis Child"},{"key":"192_CR19","doi-asserted-by":"publisher","first-page":"1341","DOI":"10.1097\/ALN.0b013e318289bb30","volume":"118","author":"L Yu","year":"2013","unstructured":"Yu L, Ting CK, Hill BE, Orr JA, Brewer LM, et al. Using the entropy of tracheal sounds to detect apnea during sedation in healthy nonobese volunteers. Anesthesiology. 2013;118:1341\u20139.","journal-title":"Anesthesiology"},{"key":"192_CR20","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1109\/TBME.2011.2109717","volume":"58","author":"A Yadollahi","year":"2011","unstructured":"Yadollahi A, Moussavi ZM. The effect of anthropometric variations on acoustical flow estimation: proposing a novel approach for flow estimation without the need for individual calibration. IEEE Trans Biomed Eng. 2011;58:1663\u201370.","journal-title":"IEEE Trans Biomed Eng"},{"key":"192_CR21","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1007\/s11517-010-0674-2","volume":"48","author":"A Yadollahi","year":"2010","unstructured":"Yadollahi A, Giannouli E, Moussavi Z. Sleep apnea monitoring and diagnosis based on pulse oximetry and tracheal sound signals. Med Biol Eng Comput. 2010;48:1087\u201397.","journal-title":"Med Biol Eng Comput"},{"key":"192_CR22","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1109\/TBME.2005.869789","volume":"53","author":"A Yadollahi","year":"2006","unstructured":"Yadollahi A, Moussavi ZM. A robust method for heart sounds localization using lung sounds entropy. IEEE Trans Biomed Eng. 2006;53:497\u2013502.","journal-title":"IEEE Trans Biomed Eng"},{"key":"192_CR23","doi-asserted-by":"crossref","unstructured":"Huq S, Yadollahi A, Moussavi Z. Breath analysis of respiratory flow using tracheal sounds. In IEEE International Symposium on Signal Processing and Information Technology. IEEE Xplore; 2008. pp.\u00a0414\u201318","DOI":"10.1109\/ISSPIT.2007.4458134"},{"key":"192_CR24","doi-asserted-by":"crossref","unstructured":"Yadollahi A, Moussavi Z. (2008) Comparison of flow-sound relationship for different features of tracheal sound. In IEEE Engineering in Medicine and Biology Society; 2008. pp.\u00a0805\u2013808.","DOI":"10.1109\/IEMBS.2008.4649276"},{"key":"192_CR25","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1097\/ALN.0b013e31827773e9","volume":"118","author":"JL Apfelbaum","year":"2013","unstructured":"Apfelbaum JL, Silverstein JH, Chung FF, Connis RT, Fillmore RB, et al. Practice guidelines for postanesthetic care: an updated report by the American Society of Anesthesiologists Task Force on Postanesthetic Care. Anesthesiology. 2013;118:291\u2013307.","journal-title":"Anesthesiology"},{"key":"192_CR26","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1109\/TBME.2006.870231","volume":"53","author":"A Yadollahi","year":"2006","unstructured":"Yadollahi A, Moussavi ZM. A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans Biomed Eng. 2006;53:662\u20138.","journal-title":"IEEE Trans Biomed Eng"},{"key":"192_CR27","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1164\/ajrccm.163.2.2006058","volume":"163","author":"R Farr\u00e9","year":"2001","unstructured":"Farr\u00e9 R, Rigau J, Montserrat JM, Ballester E, Navajas D. Relevance of linearizing nasal prongs for assessing hypopneas and flow limitation during sleep. Am J Respir Crit Care Med. 2001;163:494\u20137.","journal-title":"Am J Respir Crit Care Med"},{"key":"192_CR28","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1213\/ANE.0b013e318290c798","volume":"117","author":"MA Ramsay","year":"2013","unstructured":"Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69\u201375.","journal-title":"Anesth Analg"},{"key":"192_CR29","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1093\/bja\/aer510","volume":"108","author":"O Mimoz","year":"2012","unstructured":"Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108:872.","journal-title":"Br J Anaesth"},{"key":"192_CR30","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1097\/ALN.0000000000000564","volume":"122","author":"LA Lee","year":"2015","unstructured":"Lee LA, Caplan RA, Stephens LS, Posner KL, Terman GW, et al. Postoperative opioid-induced respiratory depression: a closed claims analysis. Anesthesiology. 2015;122:659.","journal-title":"Anesthesiology"},{"key":"192_CR31","doi-asserted-by":"crossref","first-page":"597","DOI":"10.5664\/jcsm.2172","volume":"8","author":"RB Berry","year":"2012","unstructured":"Berry RB, Budhiraja R, Gottlieb DJ, Gozal D, Iber C, et al. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med. 2012;8:597\u2013619.","journal-title":"J Clin Sleep Med"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0192-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-018-0192-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-018-0192-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:30Z","timestamp":1693518930000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-018-0192-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,11]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["192"],"URL":"https:\/\/doi.org\/10.1007\/s10877-018-0192-6","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,11]]},"assertion":[{"value":"5 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}