{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T01:17:35Z","timestamp":1778635055499,"version":"3.51.4"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2019,11,20]],"date-time":"2019-11-20T00:00:00Z","timestamp":1574208000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,11,20]],"date-time":"2019-11-20T00:00:00Z","timestamp":1574208000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004348","name":"Stockholms L\u00e4ns Landsting","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004348","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Maquet Critical Care"},{"name":"Swedens Innovation Agency"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Respiratory failure may cause hemodynamic instability with strain on the right ventricle. The capnodynamic method continuously calculates cardiac output (CO) based on effective pulmonary blood flow (CO<jats:sub>EPBF<\/jats:sub>) and could provide CO monitoring complementary to mechanical ventilation during surgery and intensive care. The aim of the current study was to evaluate the ability of a revised capnodynamic method, based on short expiratory holds (CO<jats:sub>EPBFexp<\/jats:sub>), to estimate CO during acute respiratory failure (LI) with high shunt fractions before and after compliance-based lung recruitment. Ten pigs were submitted to lung lavage and subsequent ventilator-induced lung injury. CO<jats:sub>EPBFexp<\/jats:sub>, without any shunt correction, was compared to a reference method for CO, an ultrasonic flow probe placed around the pulmonary artery trunk (CO<jats:sub>TS<\/jats:sub>) at (1) baseline in healthy lungs with PEEP 5 cmH<jats:sub>2<\/jats:sub>O (HL<jats:sub>P5<\/jats:sub>), (2) LI with PEEP 5 cmH<jats:sub>2<\/jats:sub>O (LI<jats:sub>P5<\/jats:sub>) and (3) LI after lung recruitment and PEEP adjustment (LI<jats:sub>Padj<\/jats:sub>). CO changes were enforced during LI<jats:sub>P5<\/jats:sub> and LI<jats:sub>Padj<\/jats:sub> to estimate trending. LI resulted in changes in shunt fraction from 0.1 (0.03) to 0.36 (0.1) and restored to 0.09 (0.04) after recruitment manoeuvre. Bias (levels of agreement) and percentage error between CO<jats:sub>EPBFexp<\/jats:sub> and CO<jats:sub>TS<\/jats:sub> changed from 0.5 (\u2212\u20090.5 to 1.5) L\/min and 30% at HL<jats:sub>P5<\/jats:sub> to \u2212\u20090.6 (\u2212\u20092.3 to 1.1) L\/min and 39% during LI<jats:sub>P5<\/jats:sub> and finally 1.1 (\u2212\u20090.3 to 2.5) L\/min and 38% at LI<jats:sub>Padj<\/jats:sub>. Concordance during CO changes improved from 87 to 100% after lung recruitment and PEEP adjustment. CO<jats:sub>EPBFexp<\/jats:sub> could possibly be used for continuous CO monitoring and trending in hemodynamically unstable patients with increased shunt and after recruitment manoeuvre.<\/jats:p>","DOI":"10.1007\/s10877-019-00421-w","type":"journal-article","created":{"date-parts":[[2019,11,20]],"date-time":"2019-11-20T03:03:21Z","timestamp":1574219001000},"page":"1199-1207","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Performance of a capnodynamic method estimating cardiac output during respiratory failure - before and after lung recruitment"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8206-9930","authenticated-orcid":false,"given":"Thorir Svavar","family":"Sigmundsson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomas","family":"\u00d6hman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magnus","family":"Hallb\u00e4ck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eider","family":"Redondo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernando Suarez","family":"Sipmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mats","family":"Wallin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anders","family":"Oldner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caroline","family":"H\u00e4llsj\u00f6-Sander","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H\u00e5kan","family":"Bj\u00f6rne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,11,20]]},"reference":[{"issue":"14","key":"421_CR1","doi-asserted-by":"publisher","first-page":"295","DOI":"10.21037\/atm.2017.06.66","volume":"5","author":"X Repesse","year":"2017","unstructured":"Repesse X, Vieillard-Baron A. Right heart function during acute respiratory distress syndrome. Ann Transl Med. 2017;5(14):295. https:\/\/doi.org\/10.21037\/atm.2017.06.66.","journal-title":"Ann Transl Med"},{"key":"421_CR2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-018-5172-2","author":"A Vieillard-Baron","year":"2018","unstructured":"Vieillard-Baron A, Naeije R, Haddad F, Bogaard HJ, Bull TM, Fletcher N, Lahm T, Magder S, Orde S, Schmidt G, Pinsky MR. Diagnostic workup, etiologies and management of acute right ventricle failure: a state-of-the-art paper. Intensive Care Med. 2018. https:\/\/doi.org\/10.1007\/s00134-018-5172-2.","journal-title":"Intensive Care Med"},{"issue":"10","key":"421_CR3","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.4187\/respcare.04943","volume":"61","author":"A Paternot","year":"2016","unstructured":"Paternot A, Repesse X, Vieillard-Baron A. Rationale and DESCRIPTION of right ventricle-protective ventilation in ARDS. Respir Care. 2016;61(10):1391\u20136. https:\/\/doi.org\/10.4187\/respcare.04943.","journal-title":"Respir Care"},{"issue":"5","key":"421_CR4","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1093\/bja\/aet486","volume":"112","author":"C Hallsjo Sander","year":"2014","unstructured":"Hallsjo Sander C, Hallback M, Wallin M, Emtell P, Oldner A, Bjorne H. Novel continuous capnodynamic method for cardiac output assessment during mechanical ventilation. Br J Anaesth. 2014;112(5):824\u201331. https:\/\/doi.org\/10.1093\/bja\/aet486.","journal-title":"Br J Anaesth"},{"key":"421_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-016-9891-z","author":"CH Sander","year":"2016","unstructured":"Sander CH, Sigmundsson T, Hallback M, Sipmann FS, Wallin M, Oldner A, Bjorne H. A modified breathing pattern improves the performance of a continuous capnodynamic method for estimation of effective pulmonary blood flow. J Clin Monit Comput. 2016. https:\/\/doi.org\/10.1007\/s10877-016-9891-z.","journal-title":"J Clin Monit Comput"},{"key":"421_CR6","doi-asserted-by":"publisher","DOI":"10.1111\/aas.12559","author":"C Hallsjo Sander","year":"2015","unstructured":"Hallsjo Sander C, Hallback M, Suarez Sipmann F, Wallin M, Oldner A, Bjorne H. A novel continuous capnodynamic method for cardiac output assessment in a porcine model of lung lavage. Acta Anaesthesiol Scand. 2015. https:\/\/doi.org\/10.1111\/aas.12559.","journal-title":"Acta Anaesthesiol Scand"},{"issue":"2","key":"421_CR7","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1007\/s10877-017-0021-3","volume":"32","author":"TS Sigmundsson","year":"2018","unstructured":"Sigmundsson TS, Ohman T, Hallback M, Redondo E, Sipmann FS, Wallin M, Oldner A, Hallsjo Sander C, Bjorne H. Performance of a capnodynamic method estimating effective pulmonary blood flow during transient and sustained hypercapnia. J Clin Monit Comput. 2018;32(2):311\u20139. https:\/\/doi.org\/10.1007\/s10877-017-0021-3.","journal-title":"J Clin Monit Comput"},{"issue":"3","key":"421_CR8","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.bja.2018.02.034","volume":"121","author":"J Karlsson","year":"2018","unstructured":"Karlsson J, Winberg P, Scarr B, Lonnqvist PA, Neovius E, Wallin M, Hallback M. Validation of capnodynamic determination of cardiac output by measuring effective pulmonary blood flow: a study in anaesthetised children and piglets. Br J Anaesth. 2018;121(3):550\u20138. https:\/\/doi.org\/10.1016\/j.bja.2018.02.034.","journal-title":"Br J Anaesth"},{"issue":"3","key":"421_CR9","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.bja.2018.10.064","volume":"122","author":"J Karlsson","year":"2019","unstructured":"Karlsson J, Wallin M, Hallback M, Lonnqvist PA. Capnodynamic determination of cardiac output in hypoxia-induced pulmonary hypertension in pigs. Br J Anaesth. 2019;122(3):335\u201341. https:\/\/doi.org\/10.1016\/j.bja.2018.10.064.","journal-title":"Br J Anaesth"},{"issue":"Suppl 3","key":"421_CR10","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1111\/j.1475-097X.1985.tb00601.x","volume":"5","author":"A Gedeon","year":"1985","unstructured":"Gedeon A. Noninvasive pulmonary blood flow for optimal PEEP. Clin Physiol. 1985;5(Suppl 3):49\u201358.","journal-title":"Clin Physiol"},{"issue":"1","key":"421_CR11","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.jclinepi.2010.03.002","volume":"64","author":"J Kottner","year":"2011","unstructured":"Kottner J, Audige L, Brorson S, Donner A, Gajewski BJ, Hrobjartsson A, Roberts C, Shoukri M, Streiner DL. Guidelines for reporting reliability and agreement studies (GRRAS) were proposed. J Clin Epidemiol. 2011;64(1):96\u2013106. https:\/\/doi.org\/10.1016\/j.jclinepi.2010.03.002.","journal-title":"J Clin Epidemiol"},{"issue":"Suppl 2","key":"421_CR12","first-page":"1","volume":"4","author":"S Berggren","year":"1942","unstructured":"Berggren S. The oxygen deficit of arterial blood caused by non-ventilation parts of the lung. Acta Physiol Scand. 1942;4(Suppl 2):1\u201392.","journal-title":"Acta Physiol Scand"},{"issue":"4","key":"421_CR13","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1213\/ANE.0b013e318247f6cc","volume":"114","author":"G Tusman","year":"2012","unstructured":"Tusman G, Sipmann FS, Bohm SH. Rationale of dead space measurement by volumetric capnography. Anesth Analg. 2012;114(4):866\u201374. https:\/\/doi.org\/10.1213\/ANE.0b013e318247f6cc.","journal-title":"Anesth Analg"},{"issue":"3","key":"421_CR14","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1053\/j.jvca.2011.01.003","volume":"25","author":"LA Critchley","year":"2011","unstructured":"Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth. 2011;25(3):536\u201346. https:\/\/doi.org\/10.1053\/j.jvca.2011.01.003.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"421_CR15","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1093\/bja\/aew094","volume":"116","author":"LJ Montenij","year":"2016","unstructured":"Montenij LJ, Buhre WF, Jansen JR, Kruitwagen CL, de Waal EE. Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklist. Br J Anaesth. 2016;116(6):750\u20138. https:\/\/doi.org\/10.1093\/bja\/aew094.","journal-title":"Br J Anaesth"},{"key":"421_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-015-9711-x","author":"A Hapfelmeier","year":"2015","unstructured":"Hapfelmeier A, Cecconi M, Saugel B. Cardiac output method comparison studies: the relation of the precision of agreement and the precision of method. J Clin Monit Comput. 2015. https:\/\/doi.org\/10.1007\/s10877-015-9711-x.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"421_CR17","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/cc7129","volume":"13","author":"M Cecconi","year":"2009","unstructured":"Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies\u2014with specific reference to the measurement of cardiac output. Crit Care. 2009;13(1):201. https:\/\/doi.org\/10.1186\/cc7129.","journal-title":"Crit Care"},{"issue":"4","key":"421_CR18","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571\u201382. https:\/\/doi.org\/10.1080\/10543400701329422.","journal-title":"J Biopharm Stat"},{"issue":"8476","key":"421_CR19","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307\u201310.","journal-title":"Lancet"},{"issue":"2","key":"421_CR20","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85\u201391.","journal-title":"J Clin Monit Comput"},{"issue":"5","key":"421_CR21","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1093\/bja\/aet220","volume":"111","author":"SM Axiak Flammer","year":"2013","unstructured":"Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S. Reliability of lithium dilution cardiac output in anaesthetized sheep. Br J Anaesth. 2013;111(5):833\u20139. https:\/\/doi.org\/10.1093\/bja\/aet220.","journal-title":"Br J Anaesth"},{"issue":"5","key":"421_CR22","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1213\/ANE.0b013e3181f08a5b","volume":"111","author":"LA Critchley","year":"2010","unstructured":"Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111(5):1180\u201392. https:\/\/doi.org\/10.1213\/ANE.0b013e3181f08a5b.","journal-title":"Anesth Analg"},{"issue":"4","key":"421_CR23","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1213\/ANE.0b013e3181f0c2da","volume":"111","author":"G Tusman","year":"2010","unstructured":"Tusman G, Bohm SH, Suarez-Sipmann F, Scandurra A, Hedenstierna G. Lung recruitment and positive end-expiratory pressure have different effects on CO2 elimination in healthy and sick lungs. Anesth Analg. 2010;111(4):968\u201377. https:\/\/doi.org\/10.1213\/ANE.0b013e3181f0c2da.","journal-title":"Anesth Analg"},{"key":"421_CR24","volume-title":"Performance of a revised capnodynamic method for cardiac output monitoring","author":"TS Sigmundsson","year":"2019","unstructured":"Sigmundsson TS. Performance of a revised capnodynamic method for cardiac output monitoring. Stockholm: Karolinska Institute; 2019."},{"key":"421_CR25","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/B978-0-7020-6294-0.00009-5","volume-title":"Nunn\u2019s applied respiratory physiology","author":"AB Lumb","year":"2017","unstructured":"Lumb AB. Carbon dioxide. In: Lumb AB, editor. Nunn\u2019s applied respiratory physiology. 8th ed. London: Elsevier; 2017. p. 151\u201367.","edition":"8"},{"issue":"6","key":"421_CR26","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1007\/s10877-018-0110-y","volume":"32","author":"PJ Peyton","year":"2018","unstructured":"Peyton PJ, Kozub M. Performance of a second generation pulmonary capnotracking system for continuous monitoring of cardiac output. J Clin Monit Comput. 2018;32(6):1057\u201364. https:\/\/doi.org\/10.1007\/s10877-018-0110-y.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"421_CR27","first-page":"1001","volume":"126","author":"CW Stetz","year":"1982","unstructured":"Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis. 1982;126(6):1001\u20134.","journal-title":"Am Rev Respir Dis"},{"issue":"1","key":"421_CR28","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1136\/hrt.55.1.14","volume":"55","author":"JD Mackenzie","year":"1986","unstructured":"Mackenzie JD, Haites NE, Rawles JM. Method of assessing the reproducibility of blood flow measurement: factors influencing the performance of thermodilution cardiac output computers. Br Heart J. 1986;55(1):14\u201324.","journal-title":"Br Heart J."},{"issue":"11","key":"421_CR29","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.1111\/j.1365-2044.2012.07311.x","volume":"67","author":"SW Chong","year":"2012","unstructured":"Chong SW, Peyton PJ. A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM). Anaesthesia. 2012;67(11):1266\u201371. https:\/\/doi.org\/10.1111\/j.1365-2044.2012.07311.x.","journal-title":"Anaesthesia"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-019-00421-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-019-00421-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-019-00421-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:35Z","timestamp":1693518935000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-019-00421-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,20]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["421"],"URL":"https:\/\/doi.org\/10.1007\/s10877-019-00421-w","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,20]]},"assertion":[{"value":"1 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Magnus Hallb\u00e4ck is employed at Maquet Critical Care AB (MCC), Fernando Suarez Sipmann performs consultant activities for MCC, Mats Wallin is employed at MCC, Caroline H\u00e4llsj\u00f6 Sander has received grants for research from MCC, H\u00e5kan Bj\u00f6rne has received grants for research from MCC, Thorir Sigmundsson, Tomas \u00d6hman, Eider Redondo, Anders Oldner declares that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All applicable international, national, and\/or institutional guidelines for the care and use of animals were followed. All procedures performed in this study were in accordance with the ethical standards of the institution or practice at which the studies were conducted.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}