{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T18:43:07Z","timestamp":1748112187112},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2020,4,2]],"date-time":"2020-04-02T00:00:00Z","timestamp":1585785600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,4,2]],"date-time":"2020-04-02T00:00:00Z","timestamp":1585785600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2021,4]]},"DOI":"10.1007\/s10877-020-00503-0","type":"journal-article","created":{"date-parts":[[2020,4,2]],"date-time":"2020-04-02T10:03:44Z","timestamp":1585821824000},"page":"279-283","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["A randomized controlled study on the visual grading of the glottis and the hemodynamics response to laryngoscopy when using I-View and MacGrath Mac videolaryngoscopes in super obese patients"],"prefix":"10.1007","volume":"35","author":[{"given":"Tomasz","family":"Gaszynski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,2]]},"reference":[{"issue":"12","key":"503_CR1","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1017\/S0265021507000889","volume":"24","author":"J Marrel","year":"2007","unstructured":"Marrel J, Blanc C, Frascarolo P, Magnusson L. Videolaryngoscopy improves intubation condition in morbidly obese patients. Eur J Anaesth. 2007;24(12):1045\u20139.","journal-title":"Eur J Anaesth."},{"issue":"8","key":"503_CR2","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1007\/s11695-008-9719-0","volume":"19","author":"G Dhonneur","year":"2009","unstructured":"Dhonneur G, Abdi W, Ndoko SK, Amathieu R, Risk N, El Housseini L, Polliand C, Champault G, Combes X, Tual L. Video-assisted versus conventional tracheal intubation in morbidly obese patients. Obes Surg. 2009;19(8):1096\u2013101.","journal-title":"Obes Surg."},{"issue":"2","key":"503_CR3","doi-asserted-by":"publisher","first-page":"174","DOI":"10.4103\/0259-1162.108304","volume":"6","author":"GT Yousef","year":"2012","unstructured":"Yousef GT, Abdalgalil DA, Ibrahim TH. Orotracheal intubation of morbidly obese patients, comparison of GlideScope\u00ae video laryngoscope and the LMA CTrach\u2122 with direct laryngoscopy. Anesth Essays Res. 2012;6(2):174\u20139.","journal-title":"Anesth Essays Res."},{"issue":"1","key":"503_CR4","doi-asserted-by":"publisher","first-page":"14","DOI":"10.5603\/AIT.2014.0003","volume":"46","author":"T Gaszynski","year":"2014","unstructured":"Gaszynski T. Clinical experience with the C-Mac videolaryngoscope in morbidly obese patients. Anaesthesiol Intensive Ther. 2014;46(1):14\u20136.","journal-title":"Anaesthesiol Intensive Ther."},{"issue":"3","key":"503_CR5","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1007\/s00540-009-0780-1","volume":"23","author":"R Maassen","year":"2009","unstructured":"Maassen R, Lee R, van Zundert A, Cooper R. The videolaryngoscope is less traumatic than the classic laryngoscope for a difficult airway in an obese patient. J Anesth. 2009;23(3):445\u20138.","journal-title":"J Anesth."},{"issue":"9","key":"503_CR6","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1111\/j.1399-6576.2011.02498.x","volume":"55","author":"LH Andersen","year":"2011","unstructured":"Andersen LH, Rovsing L, Olsen KS. GlideScope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial. Acta Anaesthesiol Scand. 2011;55(9):1090\u20137.","journal-title":"Acta Anaesthesiol Scand."},{"key":"503_CR7","doi-asserted-by":"publisher","first-page":"1560","DOI":"10.1213\/ANE.0b013e3181b7303a","volume":"109","author":"R Maassen","year":"2009","unstructured":"Maassen R, Lee R, Hermans B, et al. A comparison of three videolaryngoscopes: the macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesth Analg. 2009;109:1560\u20135.","journal-title":"Anesth Analg."},{"key":"503_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-015-9727-2","author":"M Cierniak","year":"2016","unstructured":"Cierniak M, Timler D, Wieczorek A, Sekalski P, Borkowska N, Gaszy\u0144ski T. The comparison of the technical parameters in endotracheal intubation devices: the Cmac, the Vividtrac, the McGrath Mac and the Kingvision. J Clin Monit Comput. 2016. https:\/\/doi.org\/10.1007\/s10877-015-9727-2.","journal-title":"J Clin Monit Comput"},{"issue":"2","key":"503_CR9","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1093\/bja\/aew122","volume":"117","author":"A Norris","year":"2016","unstructured":"Norris A, Heidegger T. Limitations of videolaryngoscopy. Br J Anaesth. 2016;117(2):148\u201350.","journal-title":"Br J Anaesth."},{"issue":"12","key":"503_CR10","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1381\/096089206779319491","volume":"16","author":"Y Leykin","year":"2006","unstructured":"Leykin Y, Pellis T, Del Mestro E, Marzano B, Fanti G, Brodsky JB. Anesthetic management of morbidly obese and super-morbidly obese patients undergoing bariatric operations: hospital course and outcomes. Obes Surg. 2006;16(12):1563\u20139.","journal-title":"Obes Surg."},{"key":"503_CR11","doi-asserted-by":"publisher","first-page":"909","DOI":"10.2147\/DDDT.S64587","volume":"8","author":"T Gaszynski","year":"2014","unstructured":"Gaszynski T, Gaszynska E, Szewczyk T. Dexmedetomidine for awake intubation and an opioid-free general anesthesia in a superobese patient with suspected difficult intubation. Drug Des Devel Ther. 2014;8:909\u201312.","journal-title":"Drug Des Devel Ther."},{"issue":"2","key":"503_CR12","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/j.bpa.2010.02.001","volume":"24","author":"P Pelosi","year":"2010","unstructured":"Pelosi P, Gregoretti C. Perioperative management of obese patients. Best Pract Res Clin Anaesthesiol. 2010;24(2):211\u201325.","journal-title":"Best Pract Res Clin Anaesthesiol."},{"issue":"12","key":"503_CR13","first-page":"1314","volume":"82","author":"F Petrini","year":"2016","unstructured":"Petrini F, Di Giacinto I, Cataldo R, Esposito C, Pavoni V, Donato P, Obesity Task Force for the SIAARTI Airway Management Study Group, et al. Perioperative and periprocedural airway management and respiratory safety for the obese patient: 2016 SIAARTI Consensus. Minerva Anestesiol. 2016;82(12):1314\u201335.","journal-title":"Minerva Anestesiol"},{"key":"503_CR14","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14904","author":"I Ahmad","year":"2019","unstructured":"Ahmad I, El-Boghdadly K, Bhagrath R, Hodzovic I, McNarry AF, Mir F, O'Sullivan EP, Patel A, Stacey M, Vaughan D. Difficult Airway Society guidelines for awake tracheal intubation (ATI) in adults. Anaesthesia. 2019. https:\/\/doi.org\/10.1111\/anae.14904.","journal-title":"Anaesthesia"},{"issue":"11","key":"503_CR15","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1097\/EJA.0000000000000893","volume":"35","author":"M Sorbello","year":"2018","unstructured":"Sorbello M, Afshari A, De Hert S. Device or target? A paradigm shift in airway management Implications for guidelines, clinical practice and teaching. Eur J Anaesthesiol. 2018;35(11):811\u20134.","journal-title":"Eur J Anaesthesiol."},{"issue":"1","key":"503_CR16","doi-asserted-by":"publisher","first-page":"e34","DOI":"10.1213\/ANE.0000000000004176","volume":"129","author":"T Gaszynski","year":"2019","unstructured":"Gaszynski T. Nasal continuous positive airway pressure during intubation in superobese patients prolongs safe apnea period. Anesth Analg. 2019;129(1):e34. https:\/\/doi.org\/10.1213\/ANE.0000000000004176.","journal-title":"Anesth Analg."},{"issue":"3","key":"503_CR17","first-page":"133","volume":"42","author":"T Gaszynski","year":"2010","unstructured":"Gaszynski T. Pre-oxygenation in morbidly obese patients. Anestezjol Intens Ter. 2010;42(3):133\u20136.","journal-title":"Anestezjol Intens Ter."},{"issue":"2","key":"503_CR18","doi-asserted-by":"publisher","first-page":"76","DOI":"10.5152\/TJAR.2017.67764","volume":"45","author":"M Sorbello","year":"2017","unstructured":"Sorbello M, Petrini F. Supraglottic airway devices: the search for the best insertion technique or the time to change our point of view? Turk J Anaesthesiol Reanim. 2017;45(2):76\u201382.","journal-title":"Turk J Anaesthesiol Reanim."},{"key":"503_CR19","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.jclinane.2018.09.017","volume":"52","author":"T Gaszynski","year":"2019","unstructured":"Gaszynski T. The intubating laryngeal tube (iLTS-D) for blind intubation in superobese patients. J Clin Anesth. 2019;52:91\u20132.","journal-title":"J Clin Anesth."},{"issue":"7","key":"503_CR20","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1111\/anae.13837","volume":"72","author":"EJ O'Loughlin","year":"2017","unstructured":"O'Loughlin EJ, Swann AD, English JD, Ramadas R. Accuracy, intra- and inter-rater reliability of three scoring systems for the glottic view at videolaryngoscopy. Anaesthesia. 2017;72(7):835\u20139.","journal-title":"Anaesthesia"},{"issue":"2","key":"503_CR21","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1097\/ALN.0b013e318194cac8","volume":"110","author":"LH Lundstr\u00f8m","year":"2009","unstructured":"Lundstr\u00f8m LH, M\u00f8ller AM, Rosenstock C, Astrup G, Wetterslev J. High body mass index is a weak predictor for difficult and failed tracheal intubation: a cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish Anesthesia Database. Anesthesiology. 2009;110(2):266\u201374.","journal-title":"Anesthesiology"},{"issue":"4","key":"503_CR22","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1097\/EJA.0000000000000324","volume":"33","author":"W Riad","year":"2015","unstructured":"Riad W, Vaez MN, Raveendran R, et al. Neck circumference as a predictor of difficult intubation and difficult mask ventilation in morbidly obese patients: A prospective observational study. Eur J Anaesthesiol. 2015;33(4):244\u20139.","journal-title":"Eur J Anaesthesiol."},{"issue":"4","key":"503_CR23","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1093\/bja\/aeu077","volume":"112","author":"A Dixit","year":"2014","unstructured":"Dixit A, Kulshrestha M, Mathews JJ, Bhandari M. Are the obese difficult to intubate? Br J Anaesth. 2014;112(4):770\u20131.","journal-title":"Br J Anaesth."},{"key":"503_CR24","doi-asserted-by":"publisher","first-page":"335","DOI":"10.2147\/TCRM.S95695","volume":"12","author":"T Gaszynski","year":"2016","unstructured":"Gaszynski T. TotalTrack video intubating laryngeal mask in super-obese patients\u2014series of cases. Ther Clin Risk Manage. 2016;12:335\u20138.","journal-title":"Ther Clin Risk Manage"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00503-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10877-020-00503-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00503-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:37Z","timestamp":1693518937000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10877-020-00503-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,2]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,4]]}},"alternative-id":["503"],"URL":"https:\/\/doi.org\/10.1007\/s10877-020-00503-0","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,2]]},"assertion":[{"value":"18 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declares that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval was obtained for this study from Medical University of Lodz Ethics Comittee (RNN\/331\/15\/KE). All study procedures were performed inaccordance with ethical standards of this institutional research comittee and with 1964 Helsinki declaration and its later amendments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}