{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:30:11Z","timestamp":1740123011042,"version":"3.37.3"},"reference-count":5,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T00:00:00Z","timestamp":1594771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T00:00:00Z","timestamp":1594771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Hypothermia is a common perioperative complication. To prevent perioperative hypothermia amongst other things electrical heating mattresses are used. We have made an observation with the use of an electrical heating mattress that may confuse users. In this case the ECG monitoring suddenly showed spikes that looked like spikes from an implanted pacemaker. When turning off the heating mattress the spikes disappeared and returned after turning on the heating mattress again.<\/jats:p>","DOI":"10.1007\/s10877-020-00520-z","type":"journal-article","created":{"date-parts":[[2020,7,15]],"date-time":"2020-07-15T12:02:45Z","timestamp":1594814565000},"page":"671-672","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Conductive heating mattress leads to ECG changes that mimic pacemaker spikes"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4013-8755","authenticated-orcid":false,"given":"A.","family":"Br\u00e4uer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Franke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"von Hammerstein-Equord","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,7,15]]},"reference":[{"key":"520_CR1","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","volume":"387","author":"DI Sessler","year":"2016","unstructured":"Sessler DI. Perioperative thermoregulation and heat balance. Lancet. 2016;387:2655\u201364.","journal-title":"Lancet"},{"key":"520_CR2","unstructured":"NICE. Addendum to Clinical Guideline 65, Inadvertant Perioperative Hypothermia. 2016. https:\/\/www.nice.org.uk\/guidance\/cg65. Accessed 19 Mar 2020."},{"key":"520_CR3","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1055\/s-0036-1583766","volume":"65","author":"A Emmert","year":"2017","unstructured":"Emmert A, Franke R, Brandes IF, et al. Comparison of conductive and convective warming in patients undergoing video-assisted thoracic surgery: a prospective randomized clinical trial. Thorac Cardiovasc Surg. 2017;65:362\u20136.","journal-title":"Thorac Cardiovasc Surg"},{"key":"520_CR4","doi-asserted-by":"publisher","first-page":"1683","DOI":"10.1213\/01.ANE.0000062770.73862.B7","volume":"96","author":"C Negishi","year":"2003","unstructured":"Negishi C, Hasegawa K, Mukai S, et al. Resistive-heating and forced-air warming are comparably effective. Anesth Analg. 2003;96:1683\u20137.","journal-title":"Anesth Analg"},{"key":"520_CR5","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1111\/j.1365-2044.2011.06722.x","volume":"66","author":"G R\u00f6der","year":"2011","unstructured":"R\u00f6der G, Sessler DI, Roth G, et al. Intra-operative rewarming with Hot Dog\u00ae resistive heating and forced-air heating: a trial of lower-body warming. Anaesthesia. 2011;66:667\u201374.","journal-title":"Anaesthesia"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00520-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-020-00520-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00520-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:38Z","timestamp":1693518938000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-020-00520-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,15]]},"references-count":5,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,5]]}},"alternative-id":["520"],"URL":"https:\/\/doi.org\/10.1007\/s10877-020-00520-z","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"type":"print","value":"1387-1307"},{"type":"electronic","value":"1573-2614"}],"subject":[],"published":{"date-parts":[[2020,7,15]]},"assertion":[{"value":"29 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Prof. Dr. A. Br\u00e4uer is a member of the advisory board of 3M Europe and has received payments from 3M Germany, 3M Europe, 3M Asia Pacific Pte Ltd. for consultancy work. R. Franke and A. von Hammerstein-Equord had loaned a UniqueTemp\u00b0 Jelly blanket and the two UniqueTemp\u00b0 leg blankets from Geratherm Medical AG, Geschwenda, Germany for a study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}