{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:30:10Z","timestamp":1740123010252,"version":"3.37.3"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2020,6,5]],"date-time":"2020-06-05T00:00:00Z","timestamp":1591315200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,5]],"date-time":"2020-06-05T00:00:00Z","timestamp":1591315200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1007\/s10877-020-00541-8","type":"journal-article","created":{"date-parts":[[2020,6,5]],"date-time":"2020-06-05T21:02:40Z","timestamp":1591390960000},"page":"827-834","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cardiovascular dynamics during peroral endoscopic myotomy for esophageal achalasia: a prospective observational study using non-invasive finger cuff-derived pulse wave analysis"],"prefix":"10.1007","volume":"35","author":[{"given":"Bernd","family":"Saugel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Vokuhl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hans O.","family":"Pinnschmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"R\u00f6sch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Petzoldt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8442-7797","authenticated-orcid":false,"given":"Benjamin","family":"L\u00f6ser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,6,5]]},"reference":[{"key":"541_CR1","doi-asserted-by":"publisher","first-page":"1841","DOI":"10.1001\/jama.2015.2996","volume":"313","author":"JE Pandolfino","year":"2015","unstructured":"Pandolfino JE, Gawron AJ. Achalasia: a systematic review. JAMA. 2015;313:1841\u201352. https:\/\/doi.org\/10.1001\/jama.2015.2996.","journal-title":"JAMA"},{"key":"541_CR2","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1055\/s-0029-1244080","volume":"42","author":"H Inoue","year":"2010","unstructured":"Inoue H, Minami H, Kobayashi Y, Sato Y, Kaga M, Suzuki M, et al. Peroral endoscopic myotomy (POEM) for esophageal achalasia. Endoscopy. 2010;42:265\u201371. https:\/\/doi.org\/10.1055\/s-0029-1244080.","journal-title":"Endoscopy"},{"key":"541_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.gie.2014.04.014","volume":"80","author":"SN Stavropoulos","year":"2014","unstructured":"Stavropoulos SN, Desilets DJ, Fuchs KH, Gostout CJ, Haber G, Inoue H, et al. Per-oral endoscopic myotomy white paper summary. Gastrointest Endosc. 2014;80:1\u201315. https:\/\/doi.org\/10.1016\/j.gie.2014.04.014.","journal-title":"Gastrointest Endosc"},{"key":"541_CR4","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1053\/j.gastro.2013.04.057","volume":"145","author":"D Von Renteln","year":"2013","unstructured":"Von Renteln D, Fuchs KH, Fockens P, Bauerfeind P, Vassiliou MC, Werner YB, et al. Peroral endoscopic myotomy for the treatment of achalasia: an international prospective multicenter study. Gastroenterology. 2013;145:309\u201311. https:\/\/doi.org\/10.1053\/j.gastro.2013.04.057.","journal-title":"Gastroenterology"},{"key":"541_CR5","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1038\/ajg.2011.388","volume":"107","author":"D von Renteln","year":"2012","unstructured":"von Renteln D, Inoue H, Minami H, Werner YB, Pace A, Kersten JF, et al. Peroral endoscopic myotomy for the treatment of achalasia: a prospective single center study. Am J Gastroenterol. 2012;107:411\u20137. https:\/\/doi.org\/10.1038\/ajg.2011.388.","journal-title":"Am J Gastroenterol"},{"key":"541_CR6","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1001\/jama.2019.8859","volume":"322","author":"FA Ponds","year":"2019","unstructured":"Ponds FA, Fockens P, Lei A, Neuhaus H, Beyna T, Kandler J, et al. Effect of peroral endoscopic myotomy vs pneumatic dilation on symptom severity and treatment outcomes among treatment-naive patients with achalasia: a randomized clinical trial. JAMA. 2019;322:134\u201344. https:\/\/doi.org\/10.1001\/jama.2019.8859.","journal-title":"JAMA"},{"key":"541_CR7","doi-asserted-by":"publisher","first-page":"2219","DOI":"10.1056\/NEJMoa1905380","volume":"381","author":"YB Werner","year":"2019","unstructured":"Werner YB, Hakanson B, Martinek J, Repici A, von Rahden BHA, Bredenoord AJ, et al. Endoscopic or surgical myotomy in patients with idiopathic achalasia. N Engl J Med. 2019;381:2219\u201329. https:\/\/doi.org\/10.1056\/NEJMoa1905380.","journal-title":"N Engl J Med"},{"key":"541_CR8","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1007\/s00101-019-00655-y","volume":"68","author":"B L\u00f6ser","year":"2019","unstructured":"L\u00f6ser B, Werner YB, L\u00f6ser A, R\u00f6sch T, Petzoldt M. Anesthesia in gastrointestinal endoscopy: peroral endoscopic myotomy. Anaesthesist. 2019;68:607\u201314. https:\/\/doi.org\/10.1007\/s00101-019-00655-y.","journal-title":"Anaesthesist"},{"key":"541_CR9","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0000000000004420","author":"B L\u00f6ser","year":"2019","unstructured":"L\u00f6ser B, Recio Ariza O, Saugel B, Reuter DA, Z\u00f6llner C, Werner YB, et al. Anesthesia for patients undergoing peroral endoscopic myotomy procedures: a review of the literature. Anesth Analg. 2019. https:\/\/doi.org\/10.1213\/ANE.0000000000004420.","journal-title":"Anesth Analg"},{"key":"541_CR10","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1007\/s12630-017-0820-5","volume":"64","author":"B L\u00f6ser","year":"2017","unstructured":"L\u00f6ser B, Werner YB, Punke MA, Saugel B, Haas S, Reuter DA, et al. Anesthetic considerations for patients with esophageal achalasia undergoing peroral endoscopic myotomy: a retrospective case series review. Can J Anaesth. 2017;64:480\u20138. https:\/\/doi.org\/10.1007\/s12630-017-0820-5.","journal-title":"Can J Anaesth"},{"key":"541_CR11","doi-asserted-by":"publisher","first-page":"231","DOI":"10.3389\/fmed.2017.00231","volume":"4","author":"AS Meidert","year":"2017","unstructured":"Meidert AS, Saugel B. Techniques for non-invasive monitoring of arterial blood pressure. Front Med. 2017;4:231. https:\/\/doi.org\/10.3389\/fmed.2017.00231.","journal-title":"Front Med"},{"key":"541_CR12","doi-asserted-by":"publisher","first-page":"1742","DOI":"10.1053\/j.jvca.2018.06.012","volume":"33","author":"B Saugel","year":"2019","unstructured":"Saugel B, Cecconi M, Hajjar LA. Noninvasive cardiac output monitoring in cardiothoracic surgery patients: available methods and future directions. J Cardiothorac Vasc Anesth. 2019;33:1742\u201352. https:\/\/doi.org\/10.1053\/j.jvca.2018.06.012.","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"541_CR13","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1097\/MCC.0000000000000492","volume":"24","author":"B Saugel","year":"2018","unstructured":"Saugel B, Vincent J-L. Cardiac output monitoring: how to choose the optimal method for the individual patient. Curr Opin Crit Care. 2018;24:165\u201372. https:\/\/doi.org\/10.1097\/MCC.0000000000000492.","journal-title":"Curr Opin Crit Care"},{"key":"541_CR14","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1007\/s00134-016-4375-7","volume":"42","author":"J-L Teboul","year":"2016","unstructured":"Teboul J-L, Saugel B, Cecconi M, De Backer D, Hofer CK, Monnet X, et al. Less invasive hemodynamic monitoring in critically ill patients. Intensive Care Med. 2016;42:1350\u20139. https:\/\/doi.org\/10.1007\/s00134-016-4375-7.","journal-title":"Intensive Care Med"},{"key":"541_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10877-014-9619-x","volume":"29","author":"JY Wagner","year":"2015","unstructured":"Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2015;29:1\u20133. https:\/\/doi.org\/10.1007\/s10877-014-9619-x.","journal-title":"J Clin Monit Comput"},{"key":"541_CR16","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s10877-017-0027-x","volume":"32","author":"JY Wagner","year":"2018","unstructured":"Wagner JY, K\u00f6rner A, Schulte-Uentrop L, Kubik M, Reichenspurner H, Kluge S, et al. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients. J Clin Monit Comput. 2018;32:235\u201344. https:\/\/doi.org\/10.1007\/s10877-017-0027-x.","journal-title":"J Clin Monit Comput"},{"key":"541_CR17","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1007\/s10877-015-9744-1","volume":"30","author":"JY Wagner","year":"2016","unstructured":"Wagner JY, Grond J, Fortin J, Negulescu I, Sch\u00f6fthaler M, Saugel B. Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour. J Clin Monit Comput. 2016;30:487\u201393. https:\/\/doi.org\/10.1007\/s10877-015-9744-1.","journal-title":"J Clin Monit Comput"},{"key":"541_CR18","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1007\/s10877-015-9670-2","volume":"29","author":"JY Wagner","year":"2015","unstructured":"Wagner JY, Negulescu I, Sch\u00f6fthaler M, Hapfelmeier A, Meidert AS, Huber W, et al. Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients. J Clin Monit Comput. 2015;29:807\u201313. https:\/\/doi.org\/10.1007\/s10877-015-9670-2.","journal-title":"J Clin Monit Comput"},{"key":"541_CR19","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1093\/bja\/aeq143","volume":"105","author":"C Jeleazcov","year":"2010","unstructured":"Jeleazcov C, Krajinovic L, M\u00fcnster T, Birkholz T, Fried R, Sch\u00fcttler J, et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105:264\u201372. https:\/\/doi.org\/10.1093\/bja\/aeq143.","journal-title":"Br J Anaesth"},{"key":"541_CR20","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1213\/ANE.0000000000000965","volume":"121","author":"K-H Smolle","year":"2015","unstructured":"Smolle K-H, Schmid M, Prettenthaler H, Weger C. The accuracy of the CNAP\u00ae device compared with invasive radial artery measurements for providing continuous noninvasive arterial blood pressure readings at a medical intensive care unit: a method-comparison study. Anesth Analg. 2015;121:1508\u201316. https:\/\/doi.org\/10.1213\/ANE.0000000000000965.","journal-title":"Anesth Analg"},{"key":"541_CR21","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1006\/jsre.1995.1198","volume":"59","author":"HS Ho","year":"1995","unstructured":"Ho HS, Saunders C, Gunther RA, Wolfe BM. Effector of hemodynamics during laparoscopy: CO2 absorption or intra-abdominal pressure? J Surg Res. 1995;59:497\u2013503. https:\/\/doi.org\/10.1006\/jsre.1995.1198.","journal-title":"J Surg Res"},{"key":"541_CR22","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/00000539-199801000-00031","volume":"86","author":"AM Koivusalo","year":"1998","unstructured":"Koivusalo AM, Kellokumpu I, Scheinin M, Tikkanen I, M\u00e4kisalo H, Lindgren L. A comparison of gasless mechanical and conventional carbon dioxide pneumoperitoneum methods for laparoscopic cholecystectomy. Anesth Analg. 1998;86:153\u20138. https:\/\/doi.org\/10.1097\/00000539-199801000-00031.","journal-title":"Anesth Analg"},{"key":"541_CR23","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1007\/s004640000038","volume":"14","author":"EA Hirvonen","year":"2000","unstructured":"Hirvonen EA, Poikolainen EO, P\u00e4\u00e4kk\u00f6nen ME, Nuutinen LS. The adverse hemodynamic effects of anesthesia, head-up tilt, and carbon dioxide pneumoperitoneum during laparoscopic cholecystectomy. Surg Endosc. 2000;14:272\u20137. https:\/\/doi.org\/10.1007\/s004640000038.","journal-title":"Surg Endosc"},{"key":"541_CR24","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1093\/bja\/78.3.264","volume":"78","author":"AD Walder","year":"1997","unstructured":"Walder AD, Aitkenhead AR. Role of vasopressin in the haemodynamic response to laparoscopic cholecystectomy. Br J Anaesth. 1997;78:264\u20136. https:\/\/doi.org\/10.1093\/bja\/78.3.264.","journal-title":"Br J Anaesth"},{"key":"541_CR25","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1111\/j.1399-6576.1998.tb04927.x","volume":"14","author":"K Myre","year":"1998","unstructured":"Myre K, Rostrup M, Buanes T, Stokland O. Plasma catecholamines and haemodynamic changes during pneumoperitoneum. Acta Anaesthesiol Scand. 1998;14:343\u20137. https:\/\/doi.org\/10.1111\/j.1399-6576.1998.tb04927.x.","journal-title":"Acta Anaesthesiol Scand"},{"key":"541_CR26","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1161\/CIRCULATIONAHA.116.023262","volume":"135","author":"TM Atkinson","year":"2017","unstructured":"Atkinson TM, Giraud GD, Togioka BM, Jones DB, Cigarroa JE. Cardiovascular and ventilatory consequences of laparoscopic surgery. Circulation. 2017;135:700\u201310. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.116.023262.","journal-title":"Circulation"},{"key":"541_CR27","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/s00101-011-1856-5","volume":"60","author":"R H\u00f6mme","year":"2011","unstructured":"H\u00f6mme R. Anesthesia for laparoscopic interventions. Anaesthesist. 2011;60:175\u201387. https:\/\/doi.org\/10.1007\/s00101-011-1856-5.","journal-title":"Anaesthesist"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00541-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-020-00541-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00541-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:38Z","timestamp":1693518938000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-020-00541-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,5]]},"references-count":27,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["541"],"URL":"https:\/\/doi.org\/10.1007\/s10877-020-00541-8","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"type":"print","value":"1387-1307"},{"type":"electronic","value":"1573-2614"}],"subject":[],"published":{"date-parts":[[2020,6,5]]},"assertion":[{"value":"3 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"BS has received institutional restricted research grants, honoraria for giving lectures, and refunds of travel expenses from CNSystems Medizintechnik GmbH (Graz, Austria). For all other authors there is no conflict of interest to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval for this study (PV5540) was provided by the Ethics Committee of the Medical Board of Hamburg, Germany (Prof M. Carstensen) on 22 August 2017.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}