{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:30:08Z","timestamp":1740123008399,"version":"3.37.3"},"reference-count":4,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,10,23]],"date-time":"2020-10-23T00:00:00Z","timestamp":1603411200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,10,23]],"date-time":"2020-10-23T00:00:00Z","timestamp":1603411200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2021,10]]},"DOI":"10.1007\/s10877-020-00607-7","type":"journal-article","created":{"date-parts":[[2020,10,23]],"date-time":"2020-10-23T05:04:01Z","timestamp":1603429441000},"page":"1239-1240","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Endotracheal tube inflation tubing defect: an unusual cause of intraoperative volume leak"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9247-6713","authenticated-orcid":false,"given":"Abhyuday","family":"Kumar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amarjeet","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neeraj","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ajeet","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,10,23]]},"reference":[{"key":"607_CR1","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1213\/ANE.0b013e318292ee21","volume":"117","author":"M El-Orbany","year":"2013","unstructured":"El-Orbany M, Salem MR. Endotracheal tube cuff leaks: causes, consequences, and management. Anesth Analg. 2013;117:428\u201334.","journal-title":"Anesth Analg"},{"issue":"3","key":"607_CR2","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/00000542-198703000-00042","volume":"66","author":"C Verborgh","year":"1987","unstructured":"Verborgh C, Camu F. Management of cuff incompetence in an endotracheal tube. Anesthesiology. 1987;66(3):441.","journal-title":"Anesthesiology"},{"key":"607_CR3","doi-asserted-by":"publisher","first-page":"182","DOI":"10.4103\/0974-2700.62125","volume":"3","author":"B Gupta","year":"2010","unstructured":"Gupta B, Farooque K, Jain D, Kapoor R. Improper tube fixation causing a leaky cuff. J Emerg Trauma Shock. 2010;3:182\u20134.","journal-title":"J Emerg Trauma Shock"},{"key":"607_CR4","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.4037\/ajcc2014489","volume":"23","author":"C Lizy","year":"2014","unstructured":"Lizy C, Swinnen W, Labeau S, Poelaert J, Vogelaers D, Vandewoude K, et al. Cuff pressure of endotracheal tubes after changes in body position in critically ill patients treated with mechanical ventilation. Am J Crit Care. 2014;23:e1-8.","journal-title":"Am J Crit Care"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00607-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-020-00607-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-020-00607-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:39Z","timestamp":1693518939000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-020-00607-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,23]]},"references-count":4,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["607"],"URL":"https:\/\/doi.org\/10.1007\/s10877-020-00607-7","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"type":"print","value":"1387-1307"},{"type":"electronic","value":"1573-2614"}],"subject":[],"published":{"date-parts":[[2020,10,23]]},"assertion":[{"value":"13 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The procedures performed  was done in accordance with the ethical standards of the institute.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent has been taken from the patient.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}