{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T21:53:17Z","timestamp":1793915597264,"version":"4.8.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T00:00:00Z","timestamp":1619049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T00:00:00Z","timestamp":1619049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Ouest Valorisation","award":["SDSP-DV2896\/LATIM; Ouest Valorisation."],"award-info":[{"award-number":["SDSP-DV2896\/LATIM; Ouest Valorisation."]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2022,6]]},"DOI":"10.1007\/s10877-021-00708-x","type":"journal-article","created":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T08:05:46Z","timestamp":1619078746000},"page":"775-783","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Accuracy of noncontact surface imaging for tidal volume and respiratory rate measurements in the ICU"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3341-7086","authenticated-orcid":false,"given":"Erwan","family":"L\u2019Her","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Souha","family":"Nazir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoire","family":"Pateau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dimitris","family":"Visvikis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,22]]},"reference":[{"key":"708_CR1","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","volume":"342","author":"The Acute Respiratory Distress Syndrome Network","year":"2000","unstructured":"The Acute Respiratory Distress Syndrome Network. Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome. N Engl J Med. 2000;342:1301\u20138.","journal-title":"N Engl J Med"},{"key":"708_CR2","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1097\/CCM.0b013e3182451c40","volume":"40","author":"T Yoshida","year":"2012","unstructured":"Yoshida T, Uchiyama A, Matsuura N, Mashimo T, Fujino Y. Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: high transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury. Crit Care Med. 2012;40:1578\u201385.","journal-title":"Crit Care Med"},{"key":"708_CR3","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1164\/rccm.201303-0539OC","volume":"188","author":"T Yoshida","year":"2013","unstructured":"Yoshida T, Torsani V, Gomes S, et al. Spontaneous effort causes occult pendelluft during mechanical ventilation. Am J Respir Crit Care Med. 2013;188:1420\u20137.","journal-title":"Am J Respir Crit Care Med"},{"key":"708_CR4","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.23736\/S0375-9393.19.13418-9","volume":"85","author":"DL Grieco","year":"2019","unstructured":"Grieco DL, Menga LS, Eleuteri D, Antonelli M. Patient self-inflicted lung injury: implications for acute hypoxemic respiratory failure and ARDS patients on non-invasive support. Minerva Anestesiol. 2019;85:1014\u201323.","journal-title":"Minerva Anestesiol"},{"key":"708_CR5","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1164\/rccm.201605-1081CP","volume":"195","author":"L Brochard","year":"2017","unstructured":"Brochard L, Slutsky A, Pesenti A. Mechanical ventilation to minimize progression of lung injury in acute respiratory failure. Am J Respir Crit Care Med. 2017;195:438\u201342.","journal-title":"Am J Respir Crit Care Med"},{"key":"708_CR6","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1097\/00003246-198501000-00015","volume":"13","author":"CJ Brun-Buisson","year":"1985","unstructured":"Brun-Buisson CJ, Bonnet F, Bergeret S, Lemaire F, Rapin M. Recurrent high-permeability pulmonary edema associated with diabetic ketoacidosis. Crit Care Med. 1985;13:55\u20136.","journal-title":"Crit Care Med"},{"key":"708_CR7","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1007\/s00134-019-05658-2","volume":"45","author":"B Rochwerg","year":"2019","unstructured":"Rochwerg B, Granton D, Wang DX, et al. High flow nasal cannula compared with conventional oxygen therapy for acute hypoxemic respiratory failure: a systematic review and meta-analysis. Intensive Care Med. 2019;45:563\u201372.","journal-title":"Intensive Care Med"},{"key":"708_CR8","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1152\/japplphysiol.01308.2012","volume":"114","author":"T M\u00fcndel","year":"2013","unstructured":"M\u00fcndel T, Feng S, Tatkov S, Schneider H. Mechanisms of nasal high flow on ventilation during wakefulness and sleep. J Appl Physiol. 2013;114:1058\u201365.","journal-title":"J Appl Physiol"},{"key":"708_CR9","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1093\/bja\/aer265","volume":"107","author":"A Corley","year":"2011","unstructured":"Corley A, Caruana LR, Barnett AG, Tronstad O, Fraser JF. Oxygen delivery through high-flow nasal cannulae increase end-expiratory lung volume and reduce respiratory rate in post-cardiac surgical patients. Br J Anaesth. 2011;107:998\u20131004.","journal-title":"Br J Anaesth"},{"key":"708_CR10","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1136\/thoraxjnl-2015-207962","volume":"71","author":"JF Fraser","year":"2016","unstructured":"Fraser JF, Spooner AJ, Dunster KR, Anstey CM, Corley A. Nasal high flow oxygen therapy in patients with COPD reduces respiratory rate and tissue carbon dioxide while increasing tidal and end-expiratory lung volumes: a randomised crossover trial. Thorax. 2016;71:759\u201361.","journal-title":"Thorax"},{"key":"708_CR11","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1007\/s00134-017-4890-1","volume":"43","author":"T Mauri","year":"2017","unstructured":"Mauri T, Alban L, Turrini C, et al. Optimum support by high-flow nasal cannula in acute hypoxemic respiratory failure: effects of increasing flow rates. Intensive Care Med. 2017;43:1453\u201363.","journal-title":"Intensive Care Med"},{"key":"708_CR12","doi-asserted-by":"publisher","first-page":"e000200","DOI":"10.1136\/bmjresp-2017-000200","volume":"4","author":"M Okuda","year":"2017","unstructured":"Okuda M, Tanaka N, Naito K, et al. Evaluation by various methods of the physiological mechanism of a high-flow nasal cannula (HFNC) in healthy volunteers. BMJ Open Respir Res. 2017;4:e000200.","journal-title":"BMJ Open Respir Res"},{"key":"708_CR13","doi-asserted-by":"publisher","first-page":"1397","DOI":"10.4187\/respcare.04028","volume":"60","author":"RL Parke","year":"2015","unstructured":"Parke RL, Bloch A, McGuinness SP. Effect of very-high-flow nasal therapy on airway pressure and end-expiratory lung impedance in healthy volunteers. Respir Care. 2015;60:1397\u2013403.","journal-title":"Respir Care"},{"key":"708_CR14","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.4187\/respcare.06031","volume":"63","author":"GA Plotnikow","year":"2018","unstructured":"Plotnikow GA, Thille AW, Vasquez DN, et al. Effects of high-flow nasal cannula on end-expiratory lung impedance in semi-seated healthy subjects. Respir Care. 2018;63:1016\u201323.","journal-title":"Respir Care"},{"key":"708_CR15","doi-asserted-by":"publisher","first-page":"589","DOI":"10.4187\/respcare.02086","volume":"58","author":"J Riera","year":"2013","unstructured":"Riera J, P\u00e9rez P, Cort\u00e9s J, Roca O, Masclans JR, Rello J. Effect of high-flow nasal cannula and body position on end-expiratory lung volume: A cohort study using electrical impedance tomography. Respir Care. 2013;58:589\u201396.","journal-title":"Respir Care"},{"key":"708_CR16","doi-asserted-by":"publisher","first-page":"281","DOI":"10.4187\/respcare.07109","volume":"65","author":"Z Yuan","year":"2019","unstructured":"Yuan Z, Han X, Wang L, et al. Oxygen therapy delivery and body position effects measured with electrical impedance tomography. Respir Care. 2019;65:281\u20137.","journal-title":"Respir Care"},{"key":"708_CR17","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1136\/thoraxjnl-2016-208357","volume":"72","author":"I Frerichs","year":"2017","unstructured":"Frerichs I, Amato MB, van Kaam AH, et al. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax. 2017;72:83\u201393.","journal-title":"Thorax"},{"key":"708_CR18","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1111\/crj.13126","volume":"14","author":"M Sathyamoorthy","year":"2020","unstructured":"Sathyamoorthy M, Lerman J, Amolenda PG, Wilson GA, Feldman R, Moser J, Feldman U, Abraham GE 3rd, Feldman D. Tracking tidal volume noninvasively in volunteers using a tightly controlled temperature-based device: A proof of concept paper. Clin Respir J. 2020;14:260\u20136.","journal-title":"Clin Respir J"},{"key":"708_CR19","doi-asserted-by":"publisher","first-page":"2574","DOI":"10.3390\/s90402574","volume":"9","author":"D Dei","year":"2009","unstructured":"Dei D, Grazzini G, Luzi G, Pieraccini M, Atzeni C, Boncinelli S, Camiciottoli G, Castellani W, Marsili M, Dico JL. Non-contact detection of breathing using a microwave sensor. Sensors. 2009;9:2574\u201385.","journal-title":"Sensors"},{"key":"708_CR20","unstructured":"- Chekmenev Y, Rara H, Farag A. Non-contact, wavelet-based measurement of vital signs using thermal imaging. in Proc. ICGST Int.Conf.Graph,Vision and Image Processing,Cairo,Egypt,Dec. 2005, pp. 25\u201330."},{"key":"708_CR21","doi-asserted-by":"publisher","first-page":"e0221207","DOI":"10.1371\/journal.pone.0221207","volume":"14","author":"D Fleck","year":"2019","unstructured":"Fleck D, Curry C, Donnan K, Logue O, Graham K, Jackson K, Keown K, Winder J, Shields MD. Hughes CM (2019) Investigating the clinical use of structured light plethysmography to assess lung function in children with neuromuscular disorders. PLoS ONE. 2019;14:e0221207.","journal-title":"PLoS ONE"},{"key":"708_CR22","doi-asserted-by":"publisher","first-page":"7951","DOI":"10.3390\/s8127951","volume":"8","author":"I Romagnoli","year":"2008","unstructured":"Romagnoli I, Lanini B, Binazzi B, Bianchi R, Coli C, Stendardi L, Gigliotti F, Scano G. Optoelectronic Plethysmography has Improved our Knowledge of Respiratory Physiology and Pathophysiology. Sensors. 2008;8:7951\u201372.","journal-title":"Sensors"},{"key":"708_CR23","doi-asserted-by":"crossref","unstructured":"- Fankhauser P, Bloesch M, Rodriguez D, Kaestner R, Hutter M, Siegwart R. Kinect v2 for mobile robot navigation: Evaluation and modeling. In: 2015 International Conference on Advanced Robotics (ICAR). IEEE; 2015:388\u2013394.","DOI":"10.1109\/ICAR.2015.7251485"},{"key":"708_CR24","doi-asserted-by":"crossref","unstructured":"- Wasenm\u00fcller O, Stricker D. Comparison of Kinect v1 and v2 depth images in terms of accuracy and precision. In: Asian Conference on Computer Vision. Springer; 2016:34\u201345.","DOI":"10.1007\/978-3-319-54427-4_3"},{"key":"708_CR25","doi-asserted-by":"crossref","unstructured":"- Ollikkala AVH, M\u00e4kynen AJ (2007) Use of time-of-flight 3D camera in volume measurements. Proc. SPIE 7022, Advanced Laser Technologies, 702219 (5 June 2008).","DOI":"10.1117\/12.804108"},{"key":"708_CR26","unstructured":"- Dellen, B., & Rojas Jofre, I. A. (2013). Volume measurement with a consumer depth camera based on structured infrared light. In Proceedings of the 16th Catalan Conference on Artificial Intelligence, poster session (pp. 1\u201310)."},{"key":"708_CR27","doi-asserted-by":"publisher","first-page":"4275","DOI":"10.1109\/JSEN.2015.2416651","volume":"15","author":"L Yang","year":"2015","unstructured":"Yang L, Zhang L, Dong H, Alelaiwi A, El Saddik A. Evaluating and improving the depth accuracy of Kinect for Windows v2. IEEE Sens J. 2015;15:4275\u201385.","journal-title":"IEEE Sens J"},{"key":"708_CR28","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s13613-019-0485-z","volume":"9","author":"E L'Her","year":"2019","unstructured":"L\u2019Her E, N\u2019Guyen QT, Pateau V, Bodenes L, Lellouche F. Photoplethysmographic determination of the respiratory rate in acutely ill patients: validation of a new algorithm and implementation into a biomedical device. Ann Intensive Care. 2019;9:11.","journal-title":"Ann Intensive Care"},{"key":"708_CR29","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1109\/TEVC.2019.2916183","volume":"24","author":"Y Sun","year":"2019","unstructured":"Sun Y, Xue B, Zhang M, Yen GG. Evolving deep convolutional neural networks for image classification. IEEE Trans Evol Comput. 2019;24:394\u2013407.","journal-title":"IEEE Trans Evol Comput"},{"key":"708_CR30","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1002\/mp.14557","volume":"48","author":"S Nazir","year":"2021","unstructured":"Nazir S, Pateau V, Bert J, Clement JF, Fayad H, L\u2019Her E, Visvikis D. Surface imaging for real-time patient respiratory function assessment in intensive care. Med Phys. 2021;48:142\u201355.","journal-title":"Med Phys"},{"key":"708_CR31","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1589\/jpts.30.586","volume":"30","author":"H Liu","year":"2018","unstructured":"Liu H, Guo S, Liu H, et al. The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor. J Phys Ther Sci. 2018;30:586\u20139.","journal-title":"J Phys Ther Sci"},{"key":"708_CR32","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1476-7961-6-8","volume":"6","author":"CR Johnston 3rd","year":"2008","unstructured":"Johnston CR 3rd, Krishnaswamy N, Krishnaswamy G. The Hoover\u2019s Sign of Pulmonary Disease: Molecular Basis and Clinical Relevance. Clin Mol Allergy. 2008;6:8.","journal-title":"Clin Mol Allergy"},{"key":"708_CR33","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1378\/chest.122.2.651","volume":"122","author":"E Garcia-Pachon","year":"2002","unstructured":"Garcia-Pachon E. Paradoxical movement of the lateral rib margin (Hoover sign) for detecting obstructive airway disease. Chest. 2002;122:651\u20135.","journal-title":"Chest"},{"key":"708_CR34","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical method for assessing agreement between two methods of clinical measurement. The Lancet. 1986;1:307\u201310.","journal-title":"The Lancet"},{"key":"708_CR35","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.3390\/jcm8081176","volume":"8","author":"C Putensen","year":"2019","unstructured":"Putensen C, Hentze B, Muenster S, Muders T. Electrical impedance tomography for cardio-pulmonary monitoring. J Clin Med. 2019;8:1176.","journal-title":"J Clin Med"},{"key":"708_CR36","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s13054-020-2809-7","volume":"24","author":"R Zhang","year":"2020","unstructured":"Zhang R, He H, Yun L, et al. Effect of postextubation high-flow nasal cannula therapy on lung recruitment and overdistension in high-risk patient. Crit Care. 2020;24:82.","journal-title":"Crit Care"},{"key":"708_CR37","doi-asserted-by":"publisher","first-page":"281","DOI":"10.4187\/respcare.07109","volume":"65","author":"Z Yuan","year":"2020","unstructured":"Yuan Z, Han X, Wang L, et al. Oxygen therapy delivery and body position effects measured with electrical impedance tomography. Respir Care. 2020;65:281\u20137.","journal-title":"Respir Care"},{"key":"708_CR38","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1109\/TMTT.2004.823552","volume":"52","author":"AD Droitcour","year":"2004","unstructured":"Droitcour AD, Boric-Lubecke O, Lubecke VM, Lin J, Kovacs GTA. Range correlation and I\/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring. IEEE Trans Microw Theory Tech. 2004;52:838\u201348.","journal-title":"IEEE Trans Microw Theory Tech"},{"key":"708_CR39","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1109\/JSEN.2007.895979","volume":"7","author":"Y Xiao","year":"2007","unstructured":"Xiao Y, Li C, Lin J. A portable noncontact heartbeat and respiration monitoring system using 5-GHz radar. IEEE Sens J. 2007;7:1042\u20133.","journal-title":"IEEE Sens J"},{"key":"708_CR40","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.3390\/s17061408","volume":"17","author":"A Proch\u00e1zka","year":"2017","unstructured":"Proch\u00e1zka A, Charv\u00e1tov\u00e1 H, Vy\u0161ata O, Kopal J, Chambers J. Breathing analysis using thermal and depth imaging camera video records. Sensors. 2017;17:1408.","journal-title":"Sensors"},{"key":"708_CR41","doi-asserted-by":"publisher","first-page":"e38","DOI":"10.2500\/aap.2018.39.4143","volume":"39","author":"M Ghezzi","year":"2018","unstructured":"Ghezzi M, Tenero L, Piazza M, Zaffanello M, Paiola G, Piacentini GL. Feasibility of structured light plethysmography for the evaluation of lung function in preschool children with asthma. Allergy Asthma Proc. 2018;39:e38\u201342.","journal-title":"Allergy Asthma Proc"},{"key":"708_CR42","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1109\/TPAMI.2019.2929257","volume":"43","author":"Z Cao","year":"2019","unstructured":"Cao Z, Hidalgo G, Simon T, Wei SE, Sheikh Y. OpenPose: realtime multi-person 2D pose estimation using Part Affinity Fields. IEEE Trans Pattern Anal Mach Intell. 2019;43:172\u201386.","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"708_CR43","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1164\/rccm.201902-0334OC","volume":"201","author":"L Chen","year":"2020","unstructured":"Chen L, Del Sorbo L, Grieco DL, et al. Potential for lung recruitment estimated by the recruitment-to-inflation ratio in acute respiratory distress syndrome. A clinical trial. Am J Respir Crit Care Med. 2020;201:178\u201387.","journal-title":"Am J Respir Crit Care Med"},{"key":"708_CR44","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","volume":"342","author":"ARDS Network","year":"2000","unstructured":"Network ARDS, Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301\u20138.","journal-title":"N Engl J Med"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00708-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-021-00708-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00708-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T09:14:24Z","timestamp":1744190064000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-021-00708-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,22]]},"references-count":44,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022,6]]}},"alternative-id":["708"],"URL":"https:\/\/doi.org\/10.1007\/s10877-021-00708-x","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,22]]},"assertion":[{"value":"11 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"ELH, SN, DV are co-inventors of the technique (Body surface optical imaging for respiratory monitoring; European patent application No. 19306417.7\u20131115. ELH is a co-founder and shareholder of Oxynov Inc., a Canadian R&D company; he is also consultant for GE Healthcare, Smiths, Sedana Medical. VP, SN, DV have no other conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Data analysis was performed within the ReaSTOC data-warehousing project including all patients admitted to our adult medical ICU (ClinicalTrials.gov identifier NCT02893462). The protocol was approved by our local ethics committee and written informed consent was waived, according to French legislation.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}