{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T15:38:13Z","timestamp":1791905893945,"version":"4.3.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,9,24]],"date-time":"2021-09-24T00:00:00Z","timestamp":1632441600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,9,24]],"date-time":"2021-09-24T00:00:00Z","timestamp":1632441600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100004343","name":"3M","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004343","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s10877-021-00758-1","type":"journal-article","created":{"date-parts":[[2021,9,24]],"date-time":"2021-09-24T20:09:14Z","timestamp":1632514154000},"page":"1279-1287","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Clinical evaluation of a cutaneous zero-heat-flux thermometer during cardiac surgery"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3574-1306","authenticated-orcid":false,"given":"Christophe","family":"Verheyden","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9930-8045","authenticated-orcid":false,"given":"Arne","family":"Neyrinck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1371-442X","authenticated-orcid":false,"given":"Annouschka","family":"Laenen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3536-9321","authenticated-orcid":false,"given":"Steffen","family":"Rex","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elke","family":"Van Gerven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,24]]},"reference":[{"issue":"10038","key":"758_CR1","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","volume":"387","author":"DI Sessler","year":"2016","unstructured":"Sessler DI. Thermoregulation and heat balance. Lancet. 2016;387(10038):2655\u201364. https:\/\/doi.org\/10.1016\/S0140-6736(15)00981-2.","journal-title":"Lancet"},{"issue":"1","key":"758_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/01.anes.0000296719.73450.52","volume":"108","author":"S Rajagopalan","year":"2008","unstructured":"Rajagopalan S, Mascha E, Na J, Sessler DI. The effects of mild perioperative hypothermia on blood loss and transfusion requirement. Anesthesiology. 2008;108(1):71\u20137. https:\/\/doi.org\/10.1097\/01.anes.0000296719.73450.52.","journal-title":"Anesthesiology"},{"issue":"6","key":"758_CR3","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1503\/cmaj.050011","volume":"173","author":"PJ Devereaux","year":"2005","unstructured":"Devereaux PJ, Goldman L, Cook DJ, Gilbert K, Leslie K, Guyatt GH. Perioperative cardiac events in patients undergoing noncardiac surgery: a review of the magnitude of the problem, the pathophysiology of the events and methods to estimate and communicate risk. CMAJ. 2005;173(6):627\u201334. https:\/\/doi.org\/10.1503\/cmaj.050011.","journal-title":"CMAJ"},{"issue":"5","key":"758_CR4","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1213\/00000539-199505000-00027","volume":"80","author":"K Leslie","year":"1995","unstructured":"Leslie K, Sessler DI, Bjorksten AR, Moayeri A. Mild hypothermia alters propofol pharmacokinetics and increases the duration of action of atracurium. Anesth Analg. 1995;80(5):1007\u201314. https:\/\/doi.org\/10.1213\/00000539-199505000-00027.","journal-title":"Anesth Analg"},{"issue":"19","key":"758_CR5","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.1056\/NEJM199605093341901","volume":"334","author":"A Kurz","year":"1996","unstructured":"Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. N Engl J Med. 1996;334(19):1209\u201315. https:\/\/doi.org\/10.1056\/NEJM199605093341901.","journal-title":"N Engl J Med"},{"issue":"9285","key":"758_CR6","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1016\/S0140-6736(01)06071-8","volume":"358","author":"AC Melling","year":"2001","unstructured":"Melling AC, Ali B, Scott EM, Leaper DJ. Effects of preoperative warming on the incidence of wound infection after clean surgery: a randomised controlled trial. Lancet. 2001;358(9285):876\u201380. https:\/\/doi.org\/10.1016\/S0140-6736(01)06071-8.","journal-title":"Lancet"},{"issue":"8","key":"758_CR7","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1017\/S0265021507000191","volume":"24","author":"A Torossian","year":"2007","unstructured":"Torossian A. Survey on intraoperative temperature management in Europe. Eur J Anaesthesiol. 2007;24(8):668\u201375. https:\/\/doi.org\/10.1017\/S0265021507000191.","journal-title":"Eur J Anaesthesiol"},{"key":"758_CR8","unstructured":"National Institute for Health and Care Excellence (NICE). Hypothermia: prevention and management in adults having surgery, NICE Clinical guideline. NICE Guidel CG65. 2016;(April 2008)."},{"issue":"10","key":"758_CR9","doi-asserted-by":"publisher","first-page":"768","DOI":"10.7326\/M15-1150","volume":"163","author":"DJ Niven","year":"2015","unstructured":"Niven DJ, Gaudet JE, Laupland KB, Mrklas KJ, Roberts DJ, Stelfox HT. Accuracy of peripheral thermometers for estimating temperature: a systematic review and meta-analysis. Ann Intern Med. 2015;163(10):768\u201377. https:\/\/doi.org\/10.7326\/M15-1150.","journal-title":"Ann Intern Med"},{"issue":"5","key":"758_CR10","doi-asserted-by":"publisher","first-page":"1480","DOI":"10.1213\/ANE.0000000000001242","volume":"122","author":"Y Launey","year":"2016","unstructured":"Launey Y, Larmet R, Nesseler N, Malledant Y, Palpacuer C, Seguin P. The accuracy of temperature measurements provided by the edwards lifesciences pulmonary artery catheter. Anesth Analg. 2016;122(5):1480\u20133. https:\/\/doi.org\/10.1213\/ANE.0000000000001242.","journal-title":"Anesth Analg"},{"issue":"2","key":"758_CR11","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1016\/j.athoracsur.2015.03.126","volume":"100","author":"R Engelman","year":"2015","unstructured":"Engelman R, Baker RA, Likosky DS, et al. The Society of Thoracic Surgeons, The Society of Cardiovascular Anesthesiologists, and The American Society of ExtraCorporeal Technology: Clinical Practice Guidelines for Cardiopulmonary Bypass - Temperature Management During Cardiopulmonary Bypass. Ann Thorac Surg. 2015;100(2):748\u201357. https:\/\/doi.org\/10.1016\/j.athoracsur.2015.03.126.","journal-title":"Ann Thorac Surg"},{"issue":"3","key":"758_CR12","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1177\/0310057x1103900305","volume":"39","author":"BS Cowie","year":"2011","unstructured":"Cowie BS. Does the pulmonary artery catheter still have a role in the perioperative period? Anaesth Intensive Care. 2011;39(3):345\u201355. https:\/\/doi.org\/10.1177\/0310057x1103900305.","journal-title":"Anaesth Intensive Care"},{"issue":"5","key":"758_CR13","doi-asserted-by":"publisher","first-page":"1434","DOI":"10.1213\/ANE.0000000000001213","volume":"122","author":"M Wang","year":"2016","unstructured":"Wang M, Singh A, Qureshi H, Leone A, Mascha EJ, Sessler DI. Optimal depth for nasopharyngeal temperature probe positioning. Anesth Analg. 2016;122(5):1434\u20138. https:\/\/doi.org\/10.1213\/ANE.0000000000001213.","journal-title":"Anesth Analg"},{"issue":"10","key":"758_CR14","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1017\/S0265021508004602","volume":"25","author":"H Sato","year":"2008","unstructured":"Sato H, Yamakage M, Okuyama K, et al. Urinary bladder and oesophageal temperatures correlate better in patients with high rather than low urinary flow rates during non-cardiac surgery. Eur J Anaesthesiol. 2008;25(10):805\u20139. https:\/\/doi.org\/10.1017\/S0265021508004602.","journal-title":"Eur J Anaesthesiol"},{"issue":"1","key":"758_CR15","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1042\/cs0440081","volume":"44","author":"RH Fox","year":"1973","unstructured":"Fox RH, Solman AJ, Isaacs R, Fry AJ, MacDonald IC. A new method for monitoring deep body temperature from the skin surface. Clin Sci. 1973;44(1):81\u20136.","journal-title":"Clin Sci"},{"issue":"3","key":"758_CR16","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1213\/ANE.0000000000000319","volume":"119","author":"Y Eshraghi","year":"2014","unstructured":"Eshraghi Y, Nasr V, Parra-Sanchez I, et al. An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients. Anesth Analg. 2014;119(3):543\u20139. https:\/\/doi.org\/10.1213\/ANE.0000000000000319.","journal-title":"Anesth Analg"},{"issue":"2","key":"758_CR17","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1007\/s005400300026","volume":"17","author":"M Yamakage","year":"2003","unstructured":"Yamakage M, Namiki A. Deep temperature monitoring using a zero-heat-flow method. J Anesth. 2003;17(2):108\u201315. https:\/\/doi.org\/10.1007\/s005400300026.","journal-title":"J Anesth"},{"key":"758_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-020-00543-6","author":"A Conway","year":"2020","unstructured":"Conway A, Bittner M, Phan D, et al. Accuracy and precision of zero-heat-flux temperature measurements with the 3MTM Bair HuggerTM Temperature Monitoring System: a systematic review and meta-analysis. J Clin Monit Comput. 2020. https:\/\/doi.org\/10.1007\/s10877-020-00543-6.","journal-title":"J Clin Monit Comput"},{"key":"758_CR19","unstructured":"SpotOn Temperature Monitoring System Model 370 Operator\u2019s Manual. https:\/\/multimedia.3m.com\/mws\/media\/879803O\/operators-manual-english.pdf. Accessed 1 Mar 2021"},{"issue":"1","key":"758_CR20","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1080\/23328940.2015.1131506","volume":"3","author":"GP Kenny","year":"2016","unstructured":"Kenny GP, Sigal RJ, McGinn R. Body temperature regulation in diabetes. Temperature. 2016;3(1):119\u201345. https:\/\/doi.org\/10.1080\/23328940.2015.1131506.","journal-title":"Temperature"},{"key":"758_CR21","unstructured":"Mccarthy WF, Medical M. The estimation of sensitivity and specificity of clustered binary data. Stat Data Anal. 2002;(SUGI31):1\u201310."},{"issue":"4","key":"758_CR22","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571\u201382. https:\/\/doi.org\/10.1080\/10543400701329422.","journal-title":"J Biopharm Stat"},{"key":"758_CR23","doi-asserted-by":"crossref","unstructured":"Lin LI. A concordance correlation coefficient to evaluate reproducibility Author (s ): Lawrence I-Kuei Lin Published by\u202f: International Biometric Society Stable URL\u202f: http:\/\/www.jstor.org\/stable\/2532051 REFERENCES Linked references are available on JSTOR for thi. Biomatrics. 1989;45(1):255\u2013268.","DOI":"10.2307\/2532051"},{"issue":"6","key":"758_CR24","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1093\/bja\/aew094","volume":"116","author":"LJ Montenij","year":"2016","unstructured":"Montenij LJ, Buhre WF, Jansen JR, Kruitwagen CL, De Waal EE. Methodology of method comparison studies evaluating the validity of cardiac output monitors: a stepwise approach and checklist. Br J Anaesth. 2016;116(6):750\u20138. https:\/\/doi.org\/10.1093\/bja\/aew094.","journal-title":"Br J Anaesth"},{"issue":"4","key":"758_CR25","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1053\/j.jvca.2016.03.141","volume":"30","author":"MT M\u00e4kinen","year":"2016","unstructured":"M\u00e4kinen MT, Pesonen A, Jousela I, et al. Novel zero-heat-flux deep body temperature measurement in lower extremity vascular and cardiac surgery. J Cardiothorac Vasc Anesth. 2016;30(4):973\u20138. https:\/\/doi.org\/10.1053\/j.jvca.2016.03.141.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"4","key":"758_CR26","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.circv.2019.06.002","volume":"26","author":"FJ G\u00f3mez-Romero","year":"2019","unstructured":"G\u00f3mez-Romero FJ, Fern\u00e1ndez-Prada M, Fern\u00e1ndez-Su\u00e1rez FE, et al. Intra-operative temperature monitoring with two non-invasive devices (3M Spoton\u00ae and Dr\u00e4ger Tcore\u00ae) in comparison with the Swan-Ganz catheter. Cir Cardiovasc. 2019;26(4):191\u20136. https:\/\/doi.org\/10.1016\/j.circv.2019.06.002.","journal-title":"Cir Cardiovasc"},{"issue":"5","key":"758_CR27","doi-asserted-by":"publisher","first-page":"1338","DOI":"10.1213\/ANE.0000000000001542","volume":"123","author":"A Van Zundert","year":"2016","unstructured":"Van Zundert A, Wyssusek K, Vivian V. Verification of Nasopharyngeal temperature probes - they are not always where you think they are! Anesth Analg. 2016;123(5):1338\u20139. https:\/\/doi.org\/10.1213\/ANE.0000000000001542.","journal-title":"Anesth Analg"},{"issue":"2","key":"758_CR28","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1213\/01.ane.0000124680.59440.0f","volume":"99","author":"CP Kuo","year":"2004","unstructured":"Kuo CP, Wong CS, Borel CO, et al. Cerebrospinal fluid rhinorhea after thermometer insertion through the nose. Anesth Analg. 2004;99(2):617\u20139. https:\/\/doi.org\/10.1213\/01.ane.0000124680.59440.0f.","journal-title":"Anesth Analg"},{"issue":"1","key":"758_CR29","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1111\/j.1442-2050.2009.00968.x","volume":"23","author":"CT Wass","year":"2010","unstructured":"Wass CT, Long TR, Deschamps C. Entrapment of a nasopharyngeal temperature probe: an unusual complication during an apparently uneventful elective revision laparoscopic nissen fundoplication. Dis Esophagus. 2010;23(1):33\u20135. https:\/\/doi.org\/10.1111\/j.1442-2050.2009.00968.x.","journal-title":"Dis Esophagus"},{"issue":"23","key":"758_CR30","doi-asserted-by":"publisher","first-page":"2197","DOI":"10.1056\/nejmoa1310519","volume":"369","author":"N Nielsen","year":"2013","unstructured":"Nielsen N, Wetterslev J, Cronberg T, et al. Targeted temperature management at 33\u00b0C versus 36\u00b0C after cardiac arrest. N Engl J Med. 2013;369(23):2197\u2013206. https:\/\/doi.org\/10.1056\/nejmoa1310519.","journal-title":"N Engl J Med"},{"issue":"7","key":"758_CR31","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1089\/neu.2013.3197","volume":"32","author":"T Maekawa","year":"2015","unstructured":"Maekawa T, Yamashita S, Nagao S, et al. Prolonged mild therapeutic hypothermia versus fever control with tight hemodynamic monitoring and slow rewarming in patients with severe traumatic brain injury: a randomized controlled trial. J Neurotrauma. 2015;32(7):422\u20139. https:\/\/doi.org\/10.1089\/neu.2013.3197.","journal-title":"J Neurotrauma"},{"issue":"8897","key":"758_CR32","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/S0140-6736(94)91519-9","volume":"343","author":"TWH Investigators","year":"1994","unstructured":"Investigators TWH. Randomised trial of normothermic versus hypothermic coronary bypass surgery. Lancet. 1994;343(8897):559\u201363. https:\/\/doi.org\/10.1016\/S0140-6736(94)91519-9.","journal-title":"Lancet"},{"issue":"9","key":"758_CR33","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.1007\/s12325-019-01019-z","volume":"36","author":"I Urits","year":"2019","unstructured":"Urits I, Jones MR, Orhurhu V, et al. A comprehensive update of current anesthesia perspectives on therapeutic hypothermia. Adv Ther. 2019;36(9):2223\u201332. https:\/\/doi.org\/10.1007\/s12325-019-01019-z.","journal-title":"Adv Ther"},{"issue":"6","key":"758_CR34","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1016\/j.jtcvs.2017.08.015","volume":"154","author":"A Damberg","year":"2017","unstructured":"Damberg A, Carino D, Charilaou P, et al. Favorable late survival after aortic surgery under straight deep hypothermic circulatory arrest. J Thorac Cardiovasc Surg. 2017;154(6):1831-1839.e1. https:\/\/doi.org\/10.1016\/j.jtcvs.2017.08.015.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"2","key":"758_CR35","doi-asserted-by":"publisher","first-page":"70","DOI":"10.14503\/THIJ-17-6364","volume":"45","author":"P Gupta","year":"2018","unstructured":"Gupta P, Harky A, Jahangeer S, Adams B, Bashir M. Varying evidence on deep hypothermic circulatory arrest in thoracic aortic aneurysm surgery. Texas Hear Inst J. 2018;45(2):70\u20135. https:\/\/doi.org\/10.14503\/THIJ-17-6364.","journal-title":"Texas Hear Inst J"},{"issue":"5","key":"758_CR36","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1007\/s10877-018-0227-z","volume":"33","author":"E Pesonen","year":"2019","unstructured":"Pesonen E, Silvasti-Lundell M, Niemi TT, Kivisaari R, Hernesniemi J, M\u00e4kinen MT. The focus of temperature monitoring with zero-heat-flux technology (3M Bair-Hugger): a clinical study with patients undergoing craniotomy. J Clin Monit Comput. 2019;33(5):917\u201323. https:\/\/doi.org\/10.1007\/s10877-018-0227-z.","journal-title":"J Clin Monit Comput"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00758-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-021-00758-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00758-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:42Z","timestamp":1693518942000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-021-00758-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,24]]},"references-count":36,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["758"],"URL":"https:\/\/doi.org\/10.1007\/s10877-021-00758-1","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,24]]},"assertion":[{"value":"16 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest or non-financial interest in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of UZ\/KU Leuven, Herestraat 49, B 3000 Leuven (internal reference S61212, Belg. Reg-nr: B322201838291) on March 25, 2019.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Written informed consent was obtained from all individual participants included in the study.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}},{"value":"Anonymous temperature readings are available (MS Excel).","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Data availability"}}]}}