{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T05:57:27Z","timestamp":1774418247225,"version":"3.50.1"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,12,15]],"date-time":"2021-12-15T00:00:00Z","timestamp":1639526400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,12,15]],"date-time":"2021-12-15T00:00:00Z","timestamp":1639526400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","award":["W81XWH-16-1-0434"],"award-info":[{"award-number":["W81XWH-16-1-0434"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","award":["W81XWH-20-1-0696"],"award-info":[{"award-number":["W81XWH-20-1-0696"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","award":["W81XWH-21-1-0507"],"award-info":[{"award-number":["W81XWH-21-1-0507"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006955","name":"Office of Extramural Research, National Institutes of Health","doi-asserted-by":"publisher","award":["R41 HL140640"],"award-info":[{"award-number":["R41 HL140640"]}],"id":[{"id":"10.13039\/100006955","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002322","name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","doi-asserted-by":"publisher","award":["Finance Code 001"],"award-info":[{"award-number":["Finance Code 001"]}],"id":[{"id":"10.13039\/501100002322","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s10877-021-00788-9","type":"journal-article","created":{"date-parts":[[2021,12,15]],"date-time":"2021-12-15T10:03:33Z","timestamp":1639562613000},"page":"1461-1477","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6969-1223","authenticated-orcid":false,"given":"Andrea F.","family":"Cruz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5046-5592","authenticated-orcid":false,"given":"Jacob","family":"Herrmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1618-8509","authenticated-orcid":false,"given":"Carlos R. R.","family":"Carvalho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4378-5242","authenticated-orcid":false,"given":"David W.","family":"Kaczka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,15]]},"reference":[{"key":"788_CR1","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1615\/CritRevBiomedEng.v39.i4.60","volume":"39","author":"DW Kaczka","year":"2012","unstructured":"Kaczka DW, Dellac\u00e1 RL. Oscillation mechanics of the respiratory system: applications. Crit Rev Biomed Eng. 2012;39:337\u201359.","journal-title":"Crit Rev Biomed Eng"},{"key":"788_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1183\/13993003.00753-2019","volume":"55","author":"GG King","year":"2020","unstructured":"King GG, Bates J, Berger KI, Calverley P, de Melo PL, Dellac\u00e0 RL, et al. Technical standards for respiratory oscillometry. Eur Respir J. 2020;55:1\u201321. https:\/\/doi.org\/10.1183\/13993003.00753-2019.","journal-title":"Eur Respir J"},{"key":"788_CR3","doi-asserted-by":"publisher","first-page":"1884","DOI":"10.1152\/japplphysiol.00151.2009","volume":"107","author":"A Lorx","year":"2009","unstructured":"Lorx A, Szab\u00f3 B, Hercsuth M, P\u00e9nzes I, Hantos Z. Low-frequency assessment of airway and tissue mechanics in ventilated COPD patients. J Appl Physiol. 2009;107:1884\u201392. https:\/\/doi.org\/10.1152\/japplphysiol.00151.2009.","journal-title":"J Appl Physiol"},{"key":"788_CR4","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.resp.2010.03.004","volume":"171","author":"A Lorx","year":"2010","unstructured":"Lorx A, Suki B, Hercsuth M, Szab\u00f3 B, P\u00e9nzes I, Boda K, et al. Airway and tissue mechanics in ventilated patients with pneumonia. Respir Physiol Neurobiol. 2010;171:101\u20139.","journal-title":"Respir Physiol Neurobiol"},{"key":"788_CR5","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1183\/09031936.95.08071222","volume":"8","author":"R Farr\u00e9","year":"1995","unstructured":"Farr\u00e9 R, Ferrer M, Rotger M, Navajas D. Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels. Eur Respir J. 1995;8:1222\u20137.","journal-title":"Eur Respir J"},{"key":"788_CR6","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1152\/jappl.1976.41.4.590","volume":"41","author":"M Sullivan","year":"1976","unstructured":"Sullivan M, Paliotta J, Saklad M. Endotracheal tube as a factor in measurement of respiratory mechanics. J Appl Physiol. 1976;41:590\u20132. https:\/\/doi.org\/10.1152\/jappl.1976.41.4.590.","journal-title":"J Appl Physiol"},{"key":"788_CR7","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1183\/09031936.93.06060767","volume":"6","author":"KP Van De Woestijne","year":"1993","unstructured":"Van De Woestijne KP. The forced oscillation technique in intubated, mechanically-ventilated patients. Eur Respir J. 1993;6:767\u20139.","journal-title":"Eur Respir J"},{"key":"788_CR8","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s11517-007-0227-5","volume":"46","author":"FC Jandre","year":"2008","unstructured":"Jandre FC, Modesto FC, Carvalho ARS, Giannella-Neto A. The endotracheal tube biases the estimates of pulmonary recruitment and overdistension. Med Biol Eng Comput. 2008;46:69\u201373.","journal-title":"Med Biol Eng Comput"},{"key":"788_CR9","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1109\/TBME.1982.324891","volume":"BME-29","author":"E Delavault","year":"1982","unstructured":"Delavault E, Saumon G. Fourier analysis of nonlinear fluid systems. IEEE Trans Biomed Eng. 1982;BME-29:215\u20139.","journal-title":"IEEE Trans Biomed Eng"},{"key":"788_CR10","doi-asserted-by":"publisher","first-page":"775","DOI":"10.1109\/TBME.1986.325901","volume":"33","author":"BE Maki","year":"1986","unstructured":"Maki BE. Interpretation of the coherence function when using pseudorandom inputs to identify nonlinear systems. IEEE Trans Biomed Eng. 1986;33:775\u20139. https:\/\/doi.org\/10.1109\/TBME.1986.325901.","journal-title":"IEEE Trans Biomed Eng"},{"key":"788_CR11","first-page":"183","volume":"1","author":"B Dar\u00f3czy","year":"1991","unstructured":"Dar\u00f3czy B, Fabula A, Hantos Z. Use of noninteger-multiple pseudorandom excitation to minimize nonlinear effects on impedance estimation. Eur Respir Rev. 1991;1:183\u20137.","journal-title":"Eur Respir Rev"},{"key":"788_CR12","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1109\/10.168693","volume":"39","author":"B Suki","year":"1992","unstructured":"Suki B, Lutchen KR. Pseudorandom signals to estimate apparent transfer and coherence function of nonlinear systems: application to respiratory mechanics. IEEE Trans Biomed Eng. 1992;39:1142\u201351.","journal-title":"IEEE Trans Biomed Eng"},{"key":"788_CR13","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1183\/09031936.93.06060772","volume":"6","author":"R Peslin","year":"1993","unstructured":"Peslin R, Da Silva JF, Duvivier C, Chabot F. Respiratory mechanics studed by forced oscillations during artificial ventilation. Eur Respir J. 1993;6:772\u201384.","journal-title":"Eur Respir J"},{"key":"788_CR14","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/(SICI)1099-0496(199801)25:1<18::AID-PPUL2>3.0.CO;2-K","volume":"25","author":"R Gauthier","year":"1998","unstructured":"Gauthier R, Beyaert C, Feillet F, Peslin R, Monin P, Marchal F. Respiratory oscillation mechanics in infants with bronchiolitis during mechanical ventilation. Pediatr Pulmonol. 1998;25:18\u201331.","journal-title":"Pediatr Pulmonol"},{"key":"788_CR15","doi-asserted-by":"publisher","first-page":"828","DOI":"10.1093\/bja\/aep301","volume":"103","author":"J Sellares","year":"2009","unstructured":"Sellares J, Acerbi I, Loureiro H, Dellaca RL, Ferrer M, Torres A, et al. Respiratory impedance during weaning from mechanical ventilation in a mixed population of critically ill patients. Br J Anaesth. 2009;103:828\u201332.","journal-title":"Br J Anaesth"},{"key":"788_CR16","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1152\/jappl.1977.43.2.322","volume":"43","author":"MJ Tsai","year":"1977","unstructured":"Tsai MJ, Pimmel RL, Stiff EJ, Bromberg PA, Hamlin RL, et al. Respiratory parameter estimation using forced oscillatory impedance data. J Appl Physiol. 1977;43:322\u201330. https:\/\/doi.org\/10.1152\/jappl.1977.43.2.322.","journal-title":"J Appl Physiol"},{"key":"788_CR17","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1172\/JCI111061","volume":"72","author":"HL Dorkin","year":"1983","unstructured":"Dorkin HL, Stark AR, Werthammer JW, Strieder DJ, Fredberg JJ, Frantz ID. Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease. J Clin Invest. 1983;72:903\u201310.","journal-title":"J Clin Invest"},{"key":"788_CR18","doi-asserted-by":"publisher","first-page":"2899","DOI":"10.1152\/jappl.1994.77.6.2899","volume":"77","author":"P Navalesi","year":"1994","unstructured":"Navalesi P, Hernandez P, Laporta D, Landry JS, Maltais F, Navajas D, et al. Influence of site of tracheal pressure measurement on in situ estimation of endotracheal tube resistance. J Appl Physiol. 1994;77:2899\u2013906.","journal-title":"J Appl Physiol"},{"key":"788_CR19","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.resp.2012.06.008","volume":"183","author":"DW Kaczka","year":"2012","unstructured":"Kaczka DW, Smallwood JL. Constant-phase descriptions of canine lung, chest wall, and total respiratory system viscoelasticity: effects of distending pressure. Respir Physiol Neurobiol. 2012;183:75\u201384. https:\/\/doi.org\/10.1016\/j.resp.2012.06.008.","journal-title":"Respir Physiol Neurobiol"},{"key":"788_CR20","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1152\/japplphysiol.00476.2013","volume":"115","author":"DW Kaczka","year":"2013","unstructured":"Kaczka DW, Mitzner W, Brown RH. Effects of lung inflation on airway heterogeneity during histaminergic bronchoconstriction. J Appl Physiol. 2013;115:626\u201333. https:\/\/doi.org\/10.1152\/japplphysiol.00476.2013.","journal-title":"J Appl Physiol"},{"key":"788_CR21","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1097\/00000542-199309000-00014","volume":"79","author":"J Guttmann","year":"1993","unstructured":"Guttmann J, Eberhard L, Fabry B, Bertschmann W, Wolff G. Continuous calculationof intratracheal pressure in tracheally intubated patients. Anesthesiology. 1993;79:503\u201313.","journal-title":"Anesthesiology"},{"key":"788_CR22","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1111\/pan.12595","volume":"25","author":"J Spaeth","year":"2015","unstructured":"Spaeth J, Steinmann D, Kaltofen H, Guttmann J, Schumann S. The pressure drop across the endotracheal tube in mechanically ventilated pediatric patients. Pediatr Anesth. 2015;25:413\u201320. https:\/\/doi.org\/10.1111\/pan.12595.","journal-title":"Pediatr Anesth"},{"key":"788_CR23","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1183\/09031936.93.02020178","volume":"2","author":"D Navajas","year":"1989","unstructured":"Navajas D, Farr\u00e9 R, Rotger M, Canet J. Recording pressure at the distal end of the endotracheal tube to measure respiratory impedance. Eur Respir J. 1989;2:178\u201384.","journal-title":"Eur Respir J"},{"key":"788_CR24","doi-asserted-by":"publisher","first-page":"1372","DOI":"10.1152\/jappl.1990.69.4.1372","volume":"69","author":"D Navajas","year":"1990","unstructured":"Navajas D, Farr\u00e9 R, Canet J, Rotger M, Sanchis J. Respiratory input impedance in anesthetized paralyzed patients. J Appl Physiol. 1990;69:1372\u20139. https:\/\/doi.org\/10.1152\/jappl.1990.69.4.1372.","journal-title":"J Appl Physiol"},{"key":"788_CR25","first-page":"661","volume":"44","author":"JM Jaeger","year":"1999","unstructured":"Jaeger JM, Durbin CG. Special purpose endotracheal tubes. Respir Care. 1999;44:661\u201385.","journal-title":"Respir Care"},{"key":"788_CR26","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1007\/BF01681259","volume":"162","author":"RF Der","year":"1915","unstructured":"Der RF. Stromungswiderstand in den menschlichen Atemwegen und der Einfluss der unregelmassigen Verzwiegung des Bronchialsystems auf den Atmungsverlauf in verschiedenen Lungenbezirken. Pflugers Arch Gesamte Physiol Menschen Tiere. 1915;162:225\u20139.","journal-title":"Pflugers Arch Gesamte Physiol Menschen Tiere"},{"key":"788_CR27","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.resp.2008.05.005","volume":"162","author":"S Schumann","year":"2008","unstructured":"Schumann S, Krappitz M, Knut M, Hentschel R, Guttmann J, M\u00f6ller K, et al. Pressure loss caused by pediatric endotracheal tubes during high-frequency-oscillation-ventilation. Respir Physiol Neurobiol. 2008;162:132\u20137.","journal-title":"Respir Physiol Neurobiol"},{"key":"788_CR28","doi-asserted-by":"publisher","first-page":"1643","DOI":"10.1152\/jappl.1982.53.6.1643","volume":"53","author":"E Delavault","year":"1982","unstructured":"Delavault E, Saumon G, Georges R. Nonlinear fluid systems identified by random noise input. J Appl Physiol. 1982;53:1643\u20139.","journal-title":"J Appl Physiol"},{"key":"788_CR29","first-page":"615","volume":"22","author":"A Michels","year":"1986","unstructured":"Michels A, L\u00e0nds\u00e9r FJ, Cauberghs M, Van de Woestijne KP. Measurement of total respiratory impedance via the endotracheal tube; a model study. Bull Eur Physiopathol Respir. 1986;22:615\u201320.","journal-title":"Bull Eur Physiopathol Respir"},{"key":"788_CR30","first-page":"220","volume":"4","author":"H Lorino","year":"1994","unstructured":"Lorino H, Lorino AM, Mariette C, Beydon L. Measurement of resistive impedance through an endotracheal tube. Eur Respir Rev. 1994;4:220\u20136.","journal-title":"Eur Respir Rev"},{"key":"788_CR31","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1183\/09031936.96.09051079","volume":"9","author":"AM Lorino","year":"1996","unstructured":"Lorino AM, Beydon L, Mariette C, Dahan E, Lorino H. A new correction technique for measuring respiratory impedance through an endotracheal tube. Eur Respir J. 1996;9:1079\u201386.","journal-title":"Eur Respir J"},{"key":"788_CR32","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1152\/jappl.1996.80.4.1105","volume":"80","author":"L Beydon","year":"1996","unstructured":"Beydon L, Malassine P, Lorino AM, Mariette C, Bonnet F, Harf A, et al. Respiratory resistance by end-inspiratory occlusion and forced oscillations in intubated patients. J Appl Physiol. 1996;80:1105\u201311.","journal-title":"J Appl Physiol"},{"key":"788_CR33","first-page":"162","volume":"2015","author":"AF Cruz","year":"2015","unstructured":"Cruz AF, Herrmann J, Kaczka DW. Endotracheal tube compensation for respiratory impedance measurements using time-domain and frequency-domain approaches. Biomed Eng Soc Annu Meet Tampa. 2015;2015:162.","journal-title":"Biomed Eng Soc Annu Meet Tampa"},{"key":"788_CR34","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1023\/B:ABME.0000019179.87974.7d","volume":"32","author":"DW Kaczka","year":"2004","unstructured":"Kaczka DW, Lutchen KR. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation. Ann Biomed Eng. 2004;32:596\u2013608. https:\/\/doi.org\/10.1023\/B:ABME.0000019179.87974.7d.","journal-title":"Ann Biomed Eng"},{"key":"788_CR35","first-page":"146","volume":"1","author":"C Duvivier","year":"1991","unstructured":"Duvivier C, Rotger M, Da Silva JF, Peslin R, Navajas D. Static and dynamic performance of variable reluctance and piezoresistive pressure transducers for forced oscillation measurements. Eur Respir Rev. 1991;1:146\u201350.","journal-title":"Eur Respir Rev"},{"key":"788_CR36","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1109\/TAU.1967.1161901","volume":"15","author":"P Welch","year":"1967","unstructured":"Welch P. The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms. IEEE Trans Audio Electroacoust. 1967;15:70\u20133. https:\/\/doi.org\/10.1109\/TAU.1967.1161901.","journal-title":"IEEE Trans Audio Electroacoust"},{"key":"788_CR37","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1121\/1.1906949","volume":"24","author":"GB Thurston","year":"1952","unstructured":"Thurston GB. Periodic fluid flow through circular tubes. J Acoust Soc Am. 1952;24:653\u20136. https:\/\/doi.org\/10.1121\/1.1906949.","journal-title":"J Acoust Soc Am"},{"key":"788_CR38","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1152\/jappl.1990.68.3.849","volume":"68","author":"Z Hantos","year":"1990","unstructured":"Hantos Z, Dar\u00f3czy B, Csendes T, Suki B, Nagy S. Modeling of low-frequency pulmonary impedance in dogs. J Appl Physiol. 1990;68:849\u201360.","journal-title":"J Appl Physiol"},{"key":"788_CR39","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1152\/jappl.1992.73.3.1181","volume":"73","author":"R Farr\u00e9","year":"1992","unstructured":"Farr\u00e9 R, Rotger M, Navajas D. Optimized estimation of respiratory impedance by signal averaging in the time domain. J Appl Physiol. 1992;73:1181\u20139.","journal-title":"J Appl Physiol"},{"key":"788_CR40","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1097\/00000542-199309000-00014","volume":"79","author":"J Guttmann","year":"1993","unstructured":"Guttmann J, Eberhard L, Fabry B, Bertschmann W, Wolff G. Continuous calculation of intratracheal pressure in tracheally intubated patients. Anesthesiology. 1993;79:503\u201313.","journal-title":"Anesthesiology"},{"key":"788_CR41","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1097\/00003246-200004000-00018","volume":"28","author":"J Guttmann","year":"2000","unstructured":"Guttmann J, Kessler V, Mols G, Hentschel R, Haberth\u00fcr C, Geiger K. Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes. Crit Care Med. 2000;28:1018\u201326.","journal-title":"Crit Care Med"},{"key":"788_CR42","first-page":"761","volume":"11","author":"JLM Poiseuille","year":"1840","unstructured":"Poiseuille JLM. Recherches experimentales sur le mouvement des liquides dans les tubes de tres petits diametres. C R Acad Sci. 1840;11:761\u20131048.","journal-title":"C R Acad Sci"},{"key":"788_CR43","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1152\/jappl.1997.82.5.1531","volume":"82","author":"DW Kaczka","year":"1997","unstructured":"Kaczka DW, Ingenito EP, Suki B, Lutchen KR. Partitioning airway and lung tissue resistances in humans: effects of bronchoconstriction. J Appl Physiol. 1997;82:1531\u201341.","journal-title":"J Appl Physiol"},{"key":"788_CR44","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1007\/s10439-010-0214-0","volume":"39","author":"DW Kaczka","year":"2011","unstructured":"Kaczka DW, Cao K, Christensen GE, Bates JHT, Simon BA. Analysis of regional mechanics in canine lung injury using forced oscillations and 3D image registration. Ann Biomed Eng Eng. 2011;39:1112\u201324. https:\/\/doi.org\/10.1007\/s10439-010-0214-0.","journal-title":"Ann Biomed Eng Eng"},{"key":"788_CR45","doi-asserted-by":"publisher","first-page":"1722","DOI":"10.1007\/s10439-007-9339-1","volume":"35","author":"DW Kaczka","year":"2007","unstructured":"Kaczka DW, Massa CB, Simon BA. Reliability of estimating stochastic lung tissue heterogeneity from pulmonary impedance spectra: a forward-inverse modeling study. Ann Biomed Eng. 2007;35:1722\u201338. https:\/\/doi.org\/10.1007\/s10439-007-9339-1.","journal-title":"Ann Biomed Eng"},{"key":"788_CR46","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/BF02713989","volume":"156","author":"SH Loring","year":"1979","unstructured":"Loring SH, Elliott EA, Drazen JM. Kinetic energy loss and convective acceleration in respiratory resistance measurements. Lung. 1979;156:33\u201342.","journal-title":"Lung"},{"key":"788_CR47","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1152\/jappl.1981.51.1.218","volume":"51","author":"HK Chang","year":"1981","unstructured":"Chang HK, Mortola JP. Fluid dynamic factors in tracheal pressure measurement. J Appl Physiol. 1981;51:218\u201325.","journal-title":"J Appl Physiol"},{"key":"788_CR48","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/ppul.1950120410","volume":"12","author":"JH Bates","year":"1992","unstructured":"Bates JH, Sly PD, Sato J, Davey BL, Suki B. Correcting for the Bernoulli effect in lateral pressure measurements. Pediatr Pulmonol. 1992;12:251\u20136.","journal-title":"Pediatr Pulmonol"},{"key":"788_CR49","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1088\/0967-3334\/35\/2\/177","volume":"35","author":"M Aj\u010devi\u0107","year":"2014","unstructured":"Aj\u010devi\u0107 M, Lucangelo U, Ferluga M, Zin WA, Accardo A. In vitro estimation of pressure drop across tracheal tubes during high-frequency percussive ventilation. Physiol Meas. 2014;35:177\u201388. https:\/\/doi.org\/10.1088\/0967-3334\/35\/2\/177.","journal-title":"Physiol Meas"},{"key":"788_CR50","doi-asserted-by":"publisher","first-page":"545","DOI":"10.1007\/s001340050371","volume":"23","author":"B Fabry","year":"1997","unstructured":"Fabry B, Haberthu C, Guttmann J, Kuhlen R, Stocker R, Haberth\u00fcr C, et al. Breathing pattern and additional work of breathing in spontaneously breathing patients with different ventilatory demands during inspiratory pressure support and automatic tube compensation. Intensive Care Med. 1997;23:545\u201352.","journal-title":"Intensive Care Med"},{"key":"788_CR51","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1152\/jappl.1993.75.1.478","volume":"75","author":"KR Lutchen","year":"1993","unstructured":"Lutchen KR, Yang K, Kaczka DW, Suki B. Optimal ventilation waveforms for estimating low-frequency respiratory impedance. J Appl Physiol. 1993;75:478\u201388.","journal-title":"J Appl Physiol"},{"key":"788_CR52","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1152\/jappl.1999.87.1.36","volume":"87","author":"PH Jarreau","year":"1999","unstructured":"Jarreau PH, Louis B, Dassieu G, Desfrere L, Blanchard PW, Moriette G, et al. Estimation of inspiratory pressure drop in neonatal and pediatric endotracheal tubes. J Appl Physiol. 1999;87:36\u201346.","journal-title":"J Appl Physiol"}],"updated-by":[{"DOI":"10.1007\/s10877-022-00809-1","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,1,18]],"date-time":"2022-01-18T00:00:00Z","timestamp":1642464000000}}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00788-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-021-00788-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00788-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:43Z","timestamp":1693518943000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-021-00788-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,15]]},"references-count":52,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["788"],"URL":"https:\/\/doi.org\/10.1007\/s10877-021-00788-9","relation":{"correction":[{"id-type":"doi","id":"10.1007\/s10877-022-00809-1","asserted-by":"object"}]},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,15]]},"assertion":[{"value":"15 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2022","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s10877-022-00809-1","URL":"https:\/\/doi.org\/10.1007\/s10877-022-00809-1","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"JH and DWK are co-founders and shareholders of OscillaVent, Inc. AFC, JH and DWK are consultants for ZOLL Medical Corporation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"University of Iowa Animal Care and Use Committee Protocol #5061428.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}