{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,4]],"date-time":"2025-10-04T22:27:51Z","timestamp":1759616871188,"version":"3.37.3"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,12,5]],"date-time":"2021-12-05T00:00:00Z","timestamp":1638662400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,12,5]],"date-time":"2021-12-05T00:00:00Z","timestamp":1638662400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s10877-021-00789-8","type":"journal-article","created":{"date-parts":[[2021,12,5]],"date-time":"2021-12-05T08:02:05Z","timestamp":1638691325000},"page":"1479-1487","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Accuracy of pulse pressure variations for fluid responsiveness prediction in mechanically ventilated patients with biphasic positive airway pressure mode"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9686-8909","authenticated-orcid":false,"given":"Beno\u00eet","family":"Bataille","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Le Moal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Renault","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Cocquet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jade","family":"de Selle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stein","family":"Silva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,5]]},"reference":[{"key":"789_CR1","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1007\/s00134-009-1478-4","volume":"35","author":"F Vallee","year":"2009","unstructured":"Vallee F, Richard JC, Mari A, Gallas T, Arsac E, Verlaan PS, et al. Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness. Intensive Care Med. 2009;35:1004\u201310.","journal-title":"Intensive Care Med"},{"key":"789_CR2","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1093\/bja\/aes398","volume":"110","author":"FG Freitas","year":"2013","unstructured":"Freitas FG, Bafi AT, Nascente AP, Assuncao M, Mazza B, Azevedo LC, Machado FR. Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies. Br J Anaesth. 2013;110:402\u20138.","journal-title":"Br J Anaesth"},{"key":"789_CR3","doi-asserted-by":"publisher","first-page":"108","DOI":"10.5152\/TJAR.2018.29577","volume":"46","author":"CK Hofer","year":"2018","unstructured":"Hofer CK, Geisen M, Hartnack S, Dzemali O, Ganter MT, Zollinger A. Reliability of passive leg raising, stroke volume variation and pulse pressure variation to predict fluid responsiveness during weaning from mechanical ventilation after cardiac surgery: a prospective, observational study. Turk J Anaesthesiol Reanim. 2018;46:108\u201315.","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"789_CR4","first-page":"98","volume":"5","author":"P Grassi","year":"2013","unstructured":"Grassi P, Lo Nigro L, Battaglia K, Barone M, Testa F, Berlot G. Pulse pressure variation as a predictor of fluid responsiveness in mechanically ventilated patients with spontaneous breathing activity: a pragmatic observational study. HSR Proc Intensive Care Cardiovasc Anesth. 2013;5:98\u2013109.","journal-title":"HSR Proc Intensive Care Cardiovasc Anesth"},{"key":"789_CR5","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s00134-005-2587-3","volume":"31","author":"JL Teboul","year":"2005","unstructured":"Teboul JL, Vieillard-Baron A. Clinical value of pulse pressure variations in ARDS. Still an unresolved issue? Intensive Care Med. 2005;31:499\u2013500.","journal-title":"Intensive Care Med"},{"key":"789_CR6","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1093\/bja\/aep267","volume":"103","author":"A Derichard","year":"2009","unstructured":"Derichard A, Robin E, Tavernier B, Costecalde M, Fleyfel M, Onimus J, Lebuffe G, Chambon JP, Vallet B. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth. 2009;103:678\u201384.","journal-title":"Br J Anaesth"},{"key":"789_CR7","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1213\/01.ane.0000297291.01615.5c","volume":"106","author":"M Cannesson","year":"2008","unstructured":"Cannesson M, Slieker J, Desebbe O, Bauer C, Chiari P, H\u00e9naine R, Lehot J-J. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106:1195.","journal-title":"Anesth Analg"},{"key":"789_CR8","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1097\/ALN.0b013e318225b80a","volume":"115","author":"M Cannesson","year":"2011","unstructured":"Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a \u201cgray zone\u201d approach. Anesthesiology. 2011;115:231\u201341.","journal-title":"Anesthesiology"},{"key":"789_CR9","first-page":"155","volume":"26","author":"F Beloncle","year":"2017","unstructured":"Beloncle F, Roz\u00e9 H, Mortaza S, Mercat A, Richard JCM. Ventilation spontan\u00e9e au cours du syndrome de d\u00e9tresse respiratoire aigu\u00eb. M\u00e9d Intensive R\u00e9anim. 2017;26:155\u201360.","journal-title":"M\u00e9d Intensive R\u00e9anim"},{"key":"789_CR10","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1007\/s00134-017-4912-z","volume":"43","author":"Y Zhou","year":"2017","unstructured":"Zhou Y, Jin X, Lv Y, Wang P, Yang Y, Liang G, Wang B, Kang Y. Early application of airway pressure release ventilation may reduce the duration of mechanical ventilation in acute respiratory distress syndrome. Intensive Care Med. 2017;43:1648\u201359.","journal-title":"Intensive Care Med"},{"key":"789_CR11","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1164\/rccm.201801-0088CI","volume":"199","author":"J-L Teboul","year":"2018","unstructured":"Teboul J-L, Monnet X, Chemla D, Michard F. Arterial pulse pressure variation with mechanical ventilation. Am J Respir Crit Care Med. 2018;199:22\u201331.","journal-title":"Am J Respir Crit Care Med"},{"key":"789_CR12","doi-asserted-by":"publisher","first-page":"117954842090151","DOI":"10.1177\/1179548420901518","volume":"14","author":"JI Alvarado S\u00e1nchez","year":"2020","unstructured":"Alvarado S\u00e1nchez JI, Caicedo Ruiz JD, Diaztagle Fern\u00e1ndez JJ, Ospina-Tasc\u00f3n GA, Cruz Mart\u00ednez LE. Use of pulse pressure variation as predictor of fluid responsiveness in patients ventilated with low tidal volume: a systematic review and meta-analysis. Clin Med Insights Circ Respir Pulm Med. 2020;14:1179548420901518\u20131179548420901518.","journal-title":"Clin Med Insights Circ Respir Pulm Med"},{"key":"789_CR13","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1007\/s00134-007-0644-9","volume":"33","author":"S Soubrier","year":"2007","unstructured":"Soubrier S, Saulnier F, Hubert H, Delour P, Lenci H, Onimus T, Nseir S, Durocher A. Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients? Intensive Care Med. 2007;33:1117\u201324.","journal-title":"Intensive Care Med"},{"key":"789_CR14","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1001\/jama.2016.0287","volume":"315","author":"M Singer","year":"2016","unstructured":"Singer M, Deutschman CS, Seymour CW, Shankar-Hari M, Annane D, Bauer M, et al. The third international consensus definitions for sepsis and septic shock (sepsis-3). JAMA. 2016;315:801\u201310.","journal-title":"JAMA"},{"key":"789_CR15","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1016\/j.bja.2020.11.039","volume":"126","author":"B Bataille","year":"2021","unstructured":"Bataille B, de Selle J, Moussot PE, Marty P, Silva S, Cocquet P. Machine learning methods to improve bedside fluid responsiveness prediction in severe sepsis or septic shock: an observational study. Br J Anaesth. 2021;126:826\u201334.","journal-title":"Br J Anaesth"},{"key":"789_CR16","doi-asserted-by":"publisher","first-page":"1310","DOI":"10.1164\/rccm.200202-146CC","volume":"166","author":"A Vieillard-Baron","year":"2002","unstructured":"Vieillard-Baron A, Prin S, Chergui K, Dubourg O, Jardin F. Echo-Doppler demonstration of acute cor pulmonale at the bedside in the medical intensive care unit. Am J Respir Crit Care Med. 2002;166:1310\u20139.","journal-title":"Am J Respir Crit Care Med"},{"key":"789_CR17","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1186\/s13054-014-0587-9","volume":"18","author":"M Biais","year":"2014","unstructured":"Biais M, Ehrmann S, Mari A, Conte B, Mahjoub Y, Desebbe O, et al. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach. Crit Care. 2014;18:587.","journal-title":"Crit Care"},{"key":"789_CR18","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1007\/s00134-021-06506-y","volume":"47","author":"L Evans","year":"2021","unstructured":"Evans L, Rhodes A, Alhazzani W, Antonelli M, Coopersmith CM, French C, et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021. Intensive Care Med. 2021;47:1181\u2013247.","journal-title":"Intensive Care Med"},{"key":"789_CR19","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/s13054-020-2732-y","volume":"24","author":"E Kattan","year":"2020","unstructured":"Kattan E, Ospina-Tascon GA, Teboul JL, Castro R, Cecconi M, Ferri G, Bakker J, Hernandez G. Systematic assessment of fluid responsiveness during early septic shock resuscitation: secondary analysis of the ANDROMEDA-SHOCK trial. Crit Care. 2020;24:23.","journal-title":"Crit Care"},{"key":"789_CR20","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s13613-016-0216-7","volume":"6","author":"X Monnet","year":"2016","unstructured":"Monnet X, Marik PE, Teboul J-L. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6:111.","journal-title":"Ann Intensive Care"},{"key":"789_CR21","doi-asserted-by":"publisher","first-page":"2198","DOI":"10.1109\/TBME.2004.834295","volume":"51","author":"M Aboy","year":"2004","unstructured":"Aboy M, McNames J, Thong T, Phillips CR, Ellenby MS, Goldstein B. A novel algorithm to estimate the pulse pressure variation index deltaPP. IEEE Trans Biomed Eng. 2004;51:2198\u2013203.","journal-title":"IEEE Trans Biomed Eng"},{"key":"789_CR22","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1007\/s00134-008-1216-3","volume":"34","author":"L Rose","year":"2008","unstructured":"Rose L, Hawkins M. Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria. Intensive Care Med. 2008;34:1766\u201373.","journal-title":"Intensive Care Med"},{"key":"789_CR23","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1007\/s00134-007-0646-7","volume":"33","author":"B Lamia","year":"2007","unstructured":"Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL. Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med. 2007;33:1125\u201332.","journal-title":"Intensive Care Med"},{"key":"789_CR24","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1007\/s00134-012-2618-9","volume":"38","author":"Y Mahjoub","year":"2012","unstructured":"Mahjoub Y, Benoit-Fallet H, Airapetian N, Lorne E, Levrard M, Seydi AA, Amennouche N, Slama M, Dupont H. Improvement of left ventricular relaxation as assessed by tissue Doppler imaging in fluid-responsive critically ill septic patients. Intensive Care Med. 2012;38:1461\u201370.","journal-title":"Intensive Care Med"},{"key":"789_CR25","doi-asserted-by":"publisher","first-page":"R188","DOI":"10.1186\/cc11672","volume":"16","author":"L Muller","year":"2012","unstructured":"Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012;16:R188.","journal-title":"Crit Care"},{"key":"789_CR26","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1186\/s13054-014-0473-5","volume":"18","author":"H Charbonneau","year":"2014","unstructured":"Charbonneau H, Riu B, Faron M, Mari A, Kurrek MM, Ruiz J, et al. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters. Crit Care. 2014;18:473.","journal-title":"Crit Care"},{"key":"789_CR27","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1080\/03610910801894870","volume":"37","author":"R Ferdhiana","year":"2008","unstructured":"Ferdhiana R, Terpstra J, Magel RC. A nonparametric test for the ordered alternative based on Kendall\u2019s correlation coefficient. Commun Stat Simul Comput. 2008;37:1117\u201328.","journal-title":"Commun Stat Simul Comput"},{"key":"789_CR28","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","volume":"342","author":"RG Brower","year":"2000","unstructured":"Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000;342:1301\u20138.","journal-title":"N Engl J Med"},{"key":"789_CR29","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1001\/jama.2012.197018","volume":"309","author":"BM Fuller","year":"2013","unstructured":"Fuller BM, Mohr NM, Carpenter CR. Protective ventilation for patients without acute respiratory distress syndrome. JAMA. 2013;309:654\u20135.","journal-title":"JAMA"},{"key":"789_CR30","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1164\/ajrccm.162.1.9903035","volume":"162","author":"F Michard","year":"2000","unstructured":"Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134\u20138.","journal-title":"Am J Respir Crit Care Med"},{"key":"789_CR31","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.1378\/chest.121.6.2000","volume":"121","author":"F Michard","year":"2002","unstructured":"Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121:2000\u20138.","journal-title":"Chest"},{"key":"789_CR32","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1186\/s13613-020-00767-4","volume":"10","author":"R Castro","year":"2020","unstructured":"Castro R, Kattan E, Ferri G, Pairumani R, Valenzuela ED, Alegr\u00eda L, et al. Effects of capillary refill time-vs. lactate-targeted fluid resuscitation on regional, microcirculatory and hypoxia-related perfusion parameters in septic shock: a randomized controlled trial. Ann Intensive Care. 2020;10:150.","journal-title":"Ann Intensive Care"},{"key":"789_CR33","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s10877-014-9582-6","volume":"29","author":"B Bataille","year":"2015","unstructured":"Bataille B, Rao G, Cocquet P, Mora M, Masson B, Ginot J, Silva S, Moussot PE. Accuracy of ultrasound B-lines score and E\/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome. J Clin Monit Comput. 2015;29:169\u201376.","journal-title":"J Clin Monit Comput"},{"key":"789_CR34","doi-asserted-by":"publisher","first-page":"1716","DOI":"10.1038\/s41591-018-0213-5","volume":"24","author":"M Komorowski","year":"2018","unstructured":"Komorowski M, Celi LA, Badawi O, Gordon AC, Faisal AA. The Artificial Intelligence Clinician learns optimal treatment strategies for sepsis in intensive care. Nat Med. 2018;24:1716\u201320.","journal-title":"Nat Med"},{"key":"789_CR35","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1097\/CCM.0000000000000765","volume":"43","author":"DJ Kor","year":"2015","unstructured":"Kor DJ, Warner DO, Carter RE, Meade LA, Wilson GA, Li M, et al. Extravascular lung water and pulmonary vascular permeability index as markers predictive of postoperative acute respiratory distress syndrome: a prospective cohort investigation. Crit Care Med. 2015;43:665\u201373.","journal-title":"Crit Care Med"},{"key":"789_CR36","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s00134-005-2587-3","volume":"31","author":"J-L Teboul","year":"2005","unstructured":"Teboul J-L, Vieillard-Baron A. Clinical value of pulse pressure variations in ARDS. Still an unresolved issue? Intensive Care Med. 2005;31:499\u2013500.","journal-title":"Intensive Care Med"},{"key":"789_CR37","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1093\/bja\/aet442","volume":"112","author":"Y Mahjoub","year":"2014","unstructured":"Mahjoub Y, Lejeune V, Muller L, Perbet S, Zieleskiewicz L, Bart F, et al. Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study\u2020. Br J Anaesth. 2014;112:681\u20135.","journal-title":"Br J Anaesth"},{"key":"789_CR38","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1097\/CCM.0000000000003298","volume":"46","author":"JW Devlin","year":"2018","unstructured":"Devlin JW, Skrobik Y, G\u00e9linas C, Needham DM, Slooter AJC, Pandharipande PP, et al. Clinical practice guidelines for the prevention and management of pain, agitation\/sedation, delirium, immobility, and sleep disruption in adult patients in the ICU. Crit Care Med. 2018;46:1457.","journal-title":"Crit Care Med"},{"key":"789_CR39","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1097\/ALN.0b013e318229a500","volume":"115","author":"L Muller","year":"2011","unstructured":"Muller L, Toumi M, Bousquet PJ, Riu-Poulenc B, Louart G, Candela D, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 minute can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology. 2011;115:541\u20137.","journal-title":"Anesthesiology"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00789-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-021-00789-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-021-00789-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T21:55:43Z","timestamp":1693518943000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-021-00789-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,5]]},"references-count":39,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["789"],"URL":"https:\/\/doi.org\/10.1007\/s10877-021-00789-8","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"type":"print","value":"1387-1307"},{"type":"electronic","value":"1573-2614"}],"subject":[],"published":{"date-parts":[[2021,12,5]]},"assertion":[{"value":"7 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"We disclose no conflict of interest, past or future, from all the authors. Our work has not been funded by any source in addition to our regular and independent salary. We have no financial interest in the subject, in the materials or equipment used in the manuscript, or its competitors. All authors are in complete agreement with the contents of the manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by the institutional review board of Narbonne Hospital (Comit\u00e9 d\u2019\u00e9thique local, centre hospitalier de Narbonne, SIFO-D2-2019).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written consent prior to enrolment or in permitted instances, delayed participant or legal surrogate written consent following enrolment was obtained.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}