{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T17:22:21Z","timestamp":1791220941181,"version":"4.1.0"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T00:00:00Z","timestamp":1702857600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T00:00:00Z","timestamp":1702857600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"published-print":{"date-parts":[[2024,2]]},"DOI":"10.1007\/s10877-023-01104-3","type":"journal-article","created":{"date-parts":[[2023,12,18]],"date-time":"2023-12-18T06:02:02Z","timestamp":1702879322000},"page":"19-24","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Tight control of mean arterial pressure using a closed loop system for norepinephrine infusion after high-risk abdominal surgery: a randomized controlled trial"],"prefix":"10.1007","volume":"38","author":[{"given":"Sean","family":"Coeckelenbergh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxim","family":"Soucy-Proulx","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Van der Linden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthieu","family":"Clanet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Rinehart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maxime","family":"Cannesson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacques","family":"Duranteau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Joosten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,18]]},"reference":[{"issue":"1","key":"1104_CR1","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.accpm.2018.11.009","volume":"38","author":"J Rinehart","year":"2019","unstructured":"Rinehart J, Ma M, Calderon MD, Bardaji A, Hafiane R, Van der Linden P, Joosten A. Blood pressure variability in surgical and intensive care patients: is there a potential for closed-loop vasopressor administration? Anaesth Crit Care Pain Med. 2019;38(1):69\u201371.","journal-title":"Anaesth Crit Care Pain Med"},{"issue":"17","key":"1104_CR2","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1056\/NEJMoa1312173","volume":"370","author":"P Asfar","year":"2014","unstructured":"Asfar P, Meziani F, Hamel JF, Grelon F, Megarbane B, Anguel N, Mira JP, Dequin PF, Gergaud S, Weiss N, et al. High versus low blood-pressure target in patients with septic shock. N Engl J Med. 2014;370(17):1583\u201393.","journal-title":"N Engl J Med"},{"issue":"1","key":"1104_CR3","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1016\/j.bja.2020.08.051","volume":"126","author":"A Joosten","year":"2021","unstructured":"Joosten A, Chirnoaga D, Van der Linden P, Barvais L, Alexander B, Duranteau J, Vincent JL, Cannesson M, Rinehart J. Automated closed-loop versus manually controlled norepinephrine infusion in patients undergoing intermediate- to high-risk abdominal surgery: a randomised controlled trial. Br J Anaesth. 2021;126(1):210\u20138.","journal-title":"Br J Anaesth"},{"issue":"2","key":"1104_CR4","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1097\/ALN.0000000000003807","volume":"135","author":"A Joosten","year":"2021","unstructured":"Joosten A, Rinehart J, Van der Linden P, Alexander B, Penna C, De Montblanc J, Cannesson M, Vincent JL, Vicaut E, Duranteau J. Computer-assisted individualized hemodynamic management reduces intraoperative hypotension in intermediate- and high-risk surgery: a randomized controlled trial. Anesthesiology. 2021;135(2):258\u201372.","journal-title":"Anesthesiology"},{"issue":"5","key":"1104_CR5","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1213\/ANE.0000000000005888","volume":"134","author":"O Desebbe","year":"2022","unstructured":"Desebbe O, Rinehart J, Van der Linden P, Cannesson M, Delannoy B, Vigneron M, Curtil A, Hautin E, Vincent JL, Duranteau J, et al. Control of postoperative hypotension using a closed-loop system for norepinephrine infusion in patients after cardiac surgery: a randomized trial. Anesth Analg. 2022;134(5):964\u201373.","journal-title":"Anesth Analg"},{"issue":"3","key":"1104_CR6","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1097\/ALN.0000000000002581","volume":"130","author":"A Joosten","year":"2019","unstructured":"Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, Cannesson M, Rinehart J. Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology. 2019;130(3):394\u2013403.","journal-title":"Anesthesiology"},{"issue":"5","key":"1104_CR7","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1007\/s10877-018-0234-0","volume":"33","author":"J Rinehart","year":"2019","unstructured":"Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. J Clin Monit Comput. 2019;33(5):795\u2013802.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1104_CR8","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s10877-017-9981-6","volume":"32","author":"J Rinehart","year":"2018","unstructured":"Rinehart J, Ma M, Calderon MD, Cannesson M. Feasibility of automated titration of vasopressor infusions using a novel closed-loop controller. J Clin Monit Comput. 2018;32(1):5\u201311.","journal-title":"J Clin Monit Comput"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-023-01104-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-023-01104-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-023-01104-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,20]],"date-time":"2024-02-20T07:18:21Z","timestamp":1708413501000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-023-01104-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,18]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["1104"],"URL":"https:\/\/doi.org\/10.1007\/s10877-023-01104-3","relation":{},"ISSN":["1387-1307","1573-2614"],"issn-type":[{"value":"1387-1307","type":"print"},{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,18]]},"assertion":[{"value":"18 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Alexandre Joosten, Maxime Cannesson, and Joseph Rinehart are consultants for Edwards Lifesciences, USA. They have ownership interest in Sironis, and Sironis has developed the closed-loop vasopressor system used in this study. Sironis provided no direct or indirect funding in support of the current work, to the individual authors, or any of their respective departments. The other authors have no conflicts of interest concerning this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved on August 24th, 2020, by the Comit\u00e9 de Protection des Personnes Sud-Est I (2020-A01149-30) and registered prior to patient enrollment on clinicaltrials.gov (NCT04639037: November 20th, 2020).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}