{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:06:35Z","timestamp":1787169995918,"version":"build-2736575974"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T00:00:00Z","timestamp":1728518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T00:00:00Z","timestamp":1728518400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Corsano Health B.V."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-024-01229-z","type":"journal-article","created":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T08:11:09Z","timestamp":1728547869000},"page":"451-457","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Clinical evaluation of a smart wristband for monitoring oxygen saturation, pulse rate, and respiratory rate"],"prefix":"10.1007","volume":"39","author":[{"given":"Stefan H.J.","family":"Monnink","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariska","family":"van Vliet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mathijs J.","family":"Kuiper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan C.","family":"Constandse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dieke","family":"Hoftijzer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marjolein","family":"Muller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eelko","family":"Ronner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,10,10]]},"reference":[{"issue":"3","key":"1229_CR1","doi-asserted-by":"publisher","first-page":"547","DOI":"10.3390\/healthcare10030547","volume":"10","author":"MA Almarshad","year":"2022","unstructured":"Almarshad MA, Islam MS, Al-Ahmadi S, et al. Diagnostic features and potential applications of PPG Signal in Healthcare: a systematic review. Healthcare. 2022;10(3):547. https:\/\/doi.org\/10.3390\/healthcare10030547.","journal-title":"Healthcare"},{"key":"1229_CR2","doi-asserted-by":"publisher","unstructured":"Ghamari M, Castaneda D, Esparza A, et al. A review on wearable photoplethysmography sensors and their potential future applications in health care. Int J Biosens Bioelectron. 2018;4(4). https:\/\/doi.org\/10.15406\/ijbsbe.2018.04.00125.","DOI":"10.15406\/ijbsbe.2018.04.00125"},{"key":"1229_CR3","doi-asserted-by":"publisher","unstructured":"Park J, Seok HS, Kim S-S, et al. Photoplethysmogram analysis and applications: an integrative review. Front Physiol. 2022;12. https:\/\/doi.org\/10.3389\/fphys.2021.808451.","DOI":"10.3389\/fphys.2021.808451"},{"key":"1229_CR4","doi-asserted-by":"publisher","unstructured":"Allen J. Photoplethysmography and its application in clinical physiological measurement. Physiol Meas. 2007;28(3). https:\/\/doi.org\/10.1088\/0967-3334\/28\/3\/r01.","DOI":"10.1088\/0967-3334\/28\/3\/r01"},{"issue":"3","key":"1229_CR5","doi-asserted-by":"publisher","first-page":"529","DOI":"10.3181\/00379727-37-9630","volume":"37","author":"AB Hertzman","year":"1937","unstructured":"Hertzman AB. Photoelectric plethysmography of the fingers and toes in man. Experimental Biology Med. 1937;37(3):529\u201334. https:\/\/doi.org\/10.3181\/00379727-37-9630.","journal-title":"Experimental Biology Med"},{"issue":"2","key":"1229_CR6","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1152\/ajplegacy.1938.124.2.328","volume":"124","author":"AB Hertzman","year":"1938","unstructured":"Hertzman AB. The blood supply of various skin areas as estimated by the photoelectric plethysmograph. Am J Physiology-Legacy Content. 1938;124(2):328\u201340. https:\/\/doi.org\/10.1152\/ajplegacy.1938.124.2.328.","journal-title":"Am J Physiology-Legacy Content"},{"issue":"9","key":"1229_CR7","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1002\/andp.18511600904","volume":"160","author":"Beer","year":"1851","unstructured":"Beer. Versuch die absorptions-verh\u00e4ltnisse des cordierites f\u00fcr rothes licht zu bestimmen. Annalen Der Physik Und Chemie. 1851;160(9):37\u201344. https:\/\/doi.org\/10.1002\/andp.18511600904.","journal-title":"Annalen Der Physik Und Chemie"},{"issue":"3","key":"1229_CR8","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1088\/0031-9155\/19\/3\/003","volume":"19","author":"AV Challoner","year":"1974","unstructured":"Challoner AV, Ramsay CA. A photoelectric plethysmograph for the measurement of cutaneous blood flow. Phys Med Biol. 1974;19(3):317\u201328. https:\/\/doi.org\/10.1088\/0031-9155\/19\/3\/003.","journal-title":"Phys Med Biol"},{"issue":"10","key":"1229_CR9","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1093\/qjmed\/94.10.521","volume":"94","author":"CP Subbe","year":"2001","unstructured":"Subbe CP, Kruger M, Rutherford P, et al. Validation of a modified early warning score in medical admissions. QJM: Int J Med. 2001;94(10):521\u20136. https:\/\/doi.org\/10.1093\/qjmed\/94.10.521.","journal-title":"QJM: Int J Med"},{"issue":"6","key":"1229_CR10","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1200\/op.21.00532","volume":"18","author":"S Nagarajah","year":"2022","unstructured":"Nagarajah S, Krzyzanowska MK, Murphy T. Early warning scores and their application in the inpatient oncology settings. JCO Oncol Pract. 2022;18(6):465\u201373. https:\/\/doi.org\/10.1200\/op.21.00532.","journal-title":"JCO Oncol Pract"},{"key":"1229_CR11","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.ejim.2017.09.018","volume":"45","author":"J Kellett","year":"2017","unstructured":"Kellett J, Sebat F. Make vital signs great again \u2013 a call for action. Eur J Intern Med. 2017;45:13\u20139. https:\/\/doi.org\/10.1016\/j.ejim.2017.09.018.","journal-title":"Eur J Intern Med"},{"key":"1229_CR12","doi-asserted-by":"publisher","unstructured":"Al-Halawani R, Charlton PH, Qassem M, et al. A review of the effect of skin pigmentation on pulse oximeter accuracy. Physiol Meas. 2023;44(5). https:\/\/doi.org\/10.1088\/1361-6579\/acd51a.","DOI":"10.1088\/1361-6579\/acd51a"},{"issue":"14","key":"1229_CR13","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1136\/bjsports-2020-103148","volume":"55","author":"JM M\u00fchlen","year":"2021","unstructured":"M\u00fchlen JM, Stang J, Lykke Skovgaard E, et al. Recommendations for determining the validity of consumer Wearable Heart Rate devices: Expert statement and checklist of the INTERLIVE network. Br J Sports Med. 2021;55(14):767\u201379. https:\/\/doi.org\/10.1136\/bjsports-2020-103148.","journal-title":"Br J Sports Med"},{"key":"1229_CR14","unstructured":"ISO 81060-2. 2018. Non-invasive sphygmomanometers \u2014 Part 2: Clinical investigation of intermittent automated measurement type. 2018 [cited 2024 August 23]. https:\/\/www.iso.org\/standard\/73339.html"},{"key":"1229_CR15","unstructured":"ISO 81060-2. 2018\/AMD 1:2020. Non-invasive sphygmomanometers \u2014 Part 2: Clinical investigation of intermittent automated measurement type \u2014 Amendment 1. 2020 [cited 2024 August 23]. https:\/\/www.iso.org\/standard\/75432.html"},{"key":"1229_CR16","doi-asserted-by":"publisher","DOI":"10.1093\/ehjdh\/ztae006","author":"M van Vliet","year":"2024","unstructured":"van Vliet M, Monnink SH, Kuiper MJ, Constandse JC, Hoftijzer D, Ronner E. Evaluation of a novel cuffless photoplethysmography-based wristband for measuring blood pressure according to the regulatory standards. Eur Heart J - Digit Health. 2024. https:\/\/doi.org\/10.1093\/ehjdh\/ztae006.","journal-title":"Eur Heart J - Digit Health"},{"key":"1229_CR17","unstructured":"ISO 80601-2-61. 2017. Part 2\u201361: Particular requirements for basic safety and essential performance of pulse oximeter equipment. 2017 [cited 2024 August 23]. https:\/\/www.iso.org\/standard\/67963.html"},{"issue":"3","key":"1229_CR18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.2307\/2987937","volume":"32","author":"DG Altman","year":"1983","unstructured":"Altman DG, Bland JM. Measurement in medicine: the analysis of Method Comparison studies. Stat. 1983;32(3):307. https:\/\/doi.org\/10.2307\/2987937.","journal-title":"Stat"},{"issue":"6","key":"1229_CR19","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1177\/0962280211402548","volume":"22","author":"GY Zou","year":"2011","unstructured":"Zou GY. Confidence interval estimation for the bland\u2013altman limits of agreement with multiple observations per individual. Stat Methods Med Res. 2011;22(6):630\u201342. https:\/\/doi.org\/10.1177\/0962280211402548.","journal-title":"Stat Methods Med Res"},{"issue":"4","key":"1229_CR20","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571\u201382. https:\/\/doi.org\/10.1080\/10543400701329422.","journal-title":"J Biopharm Stat"},{"issue":"6","key":"1229_CR21","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1001\/archderm.124.6.869","volume":"124","author":"TB Fitzpatrick","year":"1988","unstructured":"Fitzpatrick TB. The validity and practicality of sun-reactive skin types I through VI. Arch Dermatol. 1988;124(6):869\u201371. https:\/\/doi.org\/10.1001\/archderm.124.6.869.","journal-title":"Arch Dermatol"},{"issue":"9","key":"1229_CR22","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/s00403-016-1680-5","volume":"308","author":"LA von Schuckmann","year":"2016","unstructured":"von Schuckmann LA, Hughes MC, Green AC, et al. Forearm hair density and risk of keratinocyte cancers in Australian adults. Arch Dermatol Res. 2016;308(9):617\u201324. https:\/\/doi.org\/10.1007\/s00403-016-1680-5.","journal-title":"Arch Dermatol Res"},{"key":"1229_CR23","unstructured":"Sapra A, Malik A, Bhandari P. Vital sign assessment - statpearls - NCBI bookshelf [Internet]. NCBI; 2023. https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK553213\/"},{"issue":"4","key":"1229_CR24","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3390\/bios11040126","volume":"11","author":"J Fine","year":"2021","unstructured":"Fine J, Branan KL, Rodriguez AJ, et al. Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring. Biosensors. 2021;11(4):126. https:\/\/doi.org\/10.3390\/bios11040126.","journal-title":"Biosensors"},{"key":"1229_CR25","unstructured":"Specifications corsano vitals [Internet]. Corsano Health. 2022. https:\/\/corsano.com\/wp-content\/uploads\/2023\/04\/Corsano-CardioWatch-Vital-Parameters.pdf"},{"key":"1229_CR26","doi-asserted-by":"publisher","unstructured":"Avolio A, Shirbani F, Tan I, et al. Cuffless Blood pressure monitoring and the advent of a new era in medicine and society. Handb Cuffless Blood Press Monit. 2019;1\u20137. https:\/\/doi.org\/10.1007\/978-3-030-24701-0_1.","DOI":"10.1007\/978-3-030-24701-0_1"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-024-01229-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-024-01229-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-024-01229-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,3]],"date-time":"2025-05-03T11:33:24Z","timestamp":1746272004000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-024-01229-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,10]]},"references-count":26,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["1229"],"URL":"https:\/\/doi.org\/10.1007\/s10877-024-01229-z","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,10]]},"assertion":[{"value":"19 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Ethics committee of Leiden-the Hague-Delft approved this study (REC number: NL80236.000.22).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"E. Ronner.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Guarantor"}},{"value":"ER is cardiologist in Reinier de Graaf hospital and received consultancy fees from Corsano Health, MM is a part-time employee of Corsano Health. No other authors have any conflicts of interest to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}