{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T23:07:13Z","timestamp":1794438433192,"version":"4.9.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T00:00:00Z","timestamp":1733270400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T00:00:00Z","timestamp":1733270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005416","name":"Research Council of Norway","doi-asserted-by":"crossref","award":["313922"],"award-info":[{"award-number":["313922"]}],"id":[{"id":"10.13039\/501100005416","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Purpose: This study aimed to investigate the ability of a novel wearable bioimpedance sensor to monitor changes in fluid balance induced by furosemide. Because iso-osmotic fluid loss is expected to primarily comprise fluid from the extracellular compartment it was hypothesized that isotonic hypovolemia would increase the extracellular resistance (R<jats:sub>E<\/jats:sub>). Methods: 27 healthy adults (20 women, 7 men; 35\u2009\u00b1\u200910\u00a0year.) were continuously monitored by the bioimpedance sensor following administration of furosemide. Body weight, blood pressure, heart rate, sensation of thirst and selected blood parameters were tested before furosemide administration (t0), one hour (t1) and two hours (t2) after furosemide administration, and one hour after intake of a sports drink containing carbohydrate and electrolytes (t3). Urine elimination was measured throughout the intervention, and the change in extracellular fluid volume was estimated using urine elimination and established equations. Results: During hypovolemia body weight was reduced by 1.4\u2009\u00b1\u20090.2\u00a0kg (1.7\u2009\u00b1\u20090.4%). Total urine elimination during fluid loss was 1277\u2009\u00b1\u2009190 mL. R<jats:sub>E<\/jats:sub> increased significantly from t0 to t2 (13.6\u2009\u00b1\u20092.9%). A strong correlation was observed between the estimated change in extracellular fluid volume and the measured change in R<jats:sub>E<\/jats:sub> during the isotonic fluid loss. Conclusion: This study demonstrates that the wearable bioimpedance device tested is very sensitive to furosemide-induced changes in fluid volume in healthy volunteers in a controlled environment. Additional research is needed to evaluate the ability of the device to track fluid status in a clinical setting. Trial registration: The study was registered at clinicaltrials.gov 29th of October 2021 (NCT05129358).<\/jats:p>","DOI":"10.1007\/s10877-024-01245-z","type":"journal-article","created":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T15:00:14Z","timestamp":1733324414000},"page":"379-391","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A novel wearable bioimpedance sensor for continuous monitoring of fluid balance: a study on isotonic hypovolemia in healthy adults"],"prefix":"10.1007","volume":"39","author":[{"given":"Harald","family":"Noddeland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-3018-2604","authenticated-orcid":false,"given":"Frida","family":"Bremnes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Thorud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0670-9312","authenticated-orcid":false,"given":"Katrine","family":"Rolid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00f8rn","family":"Kvaerness","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1562-1593","authenticated-orcid":false,"given":"Ellen Andreassen","family":"Jaatun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1196-0632","authenticated-orcid":false,"given":"Sigve Nyvik","family":"Aas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,4]]},"reference":[{"key":"1245_CR1","doi-asserted-by":"publisher","unstructured":"Armstrong LE. Assessing hydration status: the elusive gold standard. J Am Coll Nutr. 2007;26. https:\/\/doi.org\/10.1080\/07315724.2007.10719661.:575S-584S.","DOI":"10.1080\/07315724.2007.10719661"},{"key":"1245_CR2","doi-asserted-by":"publisher","unstructured":"Hooper L, Abdelhamid A, Attreed NJ, Campbell WW, Channell AM, Chassagne P, Culp KR, Fletcher SJ, Fortes MB, Fuller N, Gaspar PM, Gilbert DJ, Heathcote AC, Kafri MW, Kajii F, Lindner G, Mack GW, Mentes JC, Merlani P, Needham RA, Olde Rikkert MGM, Perren A, Powers J, Ranson SC, Ritz P, Rowat AM, Sj\u00f6strand F, Smith AC, Stookey JJD, Stotts NA, Thomas DR, Vivanti A, Wakefield BJ, Waldr\u00e9us N, Walsh NP, Ward S, Potter JF, Hunter P. (2015) Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people. Cochrane Database Syst Rev 2015:. https:\/\/doi.org\/10.1002\/14651858.CD009647.PUB2","DOI":"10.1002\/14651858.CD009647.PUB2"},{"key":"1245_CR3","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1053\/J.AJKD.2012.12.017","volume":"61","author":"E Hur","year":"2013","unstructured":"Hur E, Usta M, Toz H, Asci G, Wabel P, Kahvecioglu S, Kayikcioglu M, Demirci MS, Ozkahya M, Duman S, Ok E. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial. Am J Kidney Dis. 2013;61:957\u201365. https:\/\/doi.org\/10.1053\/J.AJKD.2012.12.017.","journal-title":"Am J Kidney Dis"},{"key":"1245_CR4","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/AA6F45","author":"DF Keane","year":"2017","unstructured":"Keane DF, Baxter P, Lindley E, Moissl U, Pavitt S, Rhodes L, Wieskotten S. The body composition monitor: a flexible tool for routine fluid management across the haemodialysis population. Biomed Phys Eng Express. 2017. https:\/\/doi.org\/10.1088\/2057-1976\/AA6F45. 3:.","journal-title":"Biomed Phys Eng Express"},{"key":"1245_CR5","doi-asserted-by":"publisher","first-page":"2093","DOI":"10.1515\/CCLM-2012-0289","volume":"50","author":"S Somma","year":"2012","unstructured":"Somma S, Di, Navarin S, Giordano S, Spadini F, Lippi G, Cervellin G, Dieffenbach BV, Maisel AS. The emerging role of biomarkers and bio-impedance in evaluating hydration status in patients with acute heart failure. Clin Chem Lab Med. 2012;50:2093\u2013105. https:\/\/doi.org\/10.1515\/CCLM-2012-0289.","journal-title":"Clin Chem Lab Med"},{"key":"1245_CR6","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1177\/0115426507022004389","volume":"22","author":"C Earthman","year":"2007","unstructured":"Earthman C, Traughber D, Dobratz J, Howell W. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract. 2007;22:389\u2013405. https:\/\/doi.org\/10.1177\/0115426507022004389.","journal-title":"Nutr Clin Pract"},{"key":"1245_CR7","doi-asserted-by":"crossref","unstructured":"Weyer S, R\u00f6thlingsh\u00f6fer L, Walter M, Leonhardt S. (2012) Evaluation of Bioelectrical Impedance Spectroscopy for the Assessment of Extracellular Body Water. 52.","DOI":"10.14311\/1660"},{"key":"1245_CR8","doi-asserted-by":"publisher","first-page":"1657","DOI":"10.1097\/00005768-199712000-00017","volume":"29","author":"LE Armstrong","year":"1997","unstructured":"Armstrong LE, Kenefick RW, Castellani JW, Riebe D, Kavouras SA, Kuznicki JT, Maresh CM. Bioimpedance spectroscopy technique: intra-, extracellular, and total body water. Med Sci Sports Exerc. 1997;29:1657\u201363. https:\/\/doi.org\/10.1097\/00005768-199712000-00017.","journal-title":"Med Sci Sports Exerc"},{"key":"1245_CR9","doi-asserted-by":"publisher","first-page":"2048","DOI":"10.1093\/NDT\/GFAB025","volume":"37","author":"L Lindeboom","year":"2022","unstructured":"Lindeboom L, Lee S, Wieringa F, Groenendaal W, Basile C, van der Sande F, Kooman J. On the potential of wearable bioimpedance for longitudinal fluid monitoring in end-stage kidney disease. Nephrol Dial Transpl. 2022;37:2048\u201354. https:\/\/doi.org\/10.1093\/NDT\/GFAB025.","journal-title":"Nephrol Dial Transpl"},{"key":"1245_CR10","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1111\/J.1751-7133.2011.00271.X","volume":"18","author":"IS Anand","year":"2012","unstructured":"Anand IS, Doan AD, Ma KW, Toth JA, Geyen KJ, Otterness S, Chakravarthy N, Katra RP, Libbus I. Monitoring changes in fluid status with a wireless multisensor monitor: results from the fluid removal during adherent renal monitoring (FARM) study. Congest Heart Fail. 2012;18:32\u20136. https:\/\/doi.org\/10.1111\/J.1751-7133.2011.00271.X.","journal-title":"Congest Heart Fail"},{"key":"1245_CR11","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1097\/00075197-200209000-00010","volume":"5","author":"SA Kavouras","year":"2002","unstructured":"Kavouras SA. Assessing hydration status. Curr Opin Clin Nutr Metab Care. 2002;5:519\u201324. https:\/\/doi.org\/10.1097\/00075197-200209000-00010.","journal-title":"Curr Opin Clin Nutr Metab Care"},{"key":"1245_CR12","doi-asserted-by":"publisher","first-page":"724","DOI":"10.3945\/AJCN.115.115352","volume":"103","author":"KR Heavens","year":"2016","unstructured":"Heavens KR, Charkoudian N, O\u2019Brien C, Kenefick RW, Cheuvront SN. Noninvasive assessment of extracellular and intracellular dehydration in healthy humans using the resistance-reactance\u2013score graph method. Am J Clin Nutr. 2016;103:724\u20139. https:\/\/doi.org\/10.3945\/AJCN.115.115352.","journal-title":"Am J Clin Nutr"},{"key":"1245_CR13","doi-asserted-by":"publisher","first-page":"407","DOI":"10.3357\/ASEM.3828.2014","volume":"85","author":"Q Zhang","year":"2014","unstructured":"Zhang Q, Knapp CF, Stenger MB, Patwardhan AR, Elayi SC, Wang S, Kostas VI, Evans JM. Simulations of gravitational stress on normovolemic and hypovolemic men and women. Aviat Space Environ Med. 2014;85:407. https:\/\/doi.org\/10.3357\/ASEM.3828.2014.","journal-title":"Aviat Space Environ Med"},{"key":"1245_CR14","doi-asserted-by":"publisher","first-page":"F958","DOI":"10.1152\/AJPRENAL.00476.2015","volume":"310","author":"X Huang","year":"2016","unstructured":"Huang X, Dorhout Mees E, Vos P, Hamza S, Braam B. Everything we always wanted to know about furosemide but were afraid to ask. Am J Physiol Ren Physiol. 2016;310:F958\u201371. https:\/\/doi.org\/10.1152\/AJPRENAL.00476.2015.","journal-title":"Am J Physiol Ren Physiol"},{"key":"1245_CR15","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1002\/CPHY.C130017","volume":"4","author":"SN Cheuvront","year":"2014","unstructured":"Cheuvront SN, Kenefick RW. Dehydration: physiology, assessment, and performance effects. Compr Physiol. 2014;4:257\u201385. https:\/\/doi.org\/10.1002\/CPHY.C130017.","journal-title":"Compr Physiol"},{"key":"1245_CR16","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1097\/00005768-199910000-00017","volume":"31","author":"C O\u2019Brien","year":"1999","unstructured":"O\u2019Brien C, Baker-Fulco CJ, Young AJ, Sawka MN. Bioimpedance assessment of hypohydration. Med Sci Sports Exerc. 1999;31:1466\u201371. https:\/\/doi.org\/10.1097\/00005768-199910000-00017.","journal-title":"Med Sci Sports Exerc"},{"key":"1245_CR17","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1152\/JAPPLPHYSIOL.01175.2013\/ASSET","volume":"116","author":"LG Petersen","year":"2014","unstructured":"Petersen LG, Carlsen JF, Nielsen MB, Damgaard M, Secher NH. The hydrostatic pressure indifference point underestimates orthostatic redistribution of blood in humans. J Appl Physiol. 2014;116:730\u20135. https:\/\/doi.org\/10.1152\/JAPPLPHYSIOL.01175.2013\/ASSET\/IMAGES\/LARGE\/ZDG0071409940004.JPEG.","journal-title":"J Appl Physiol"},{"key":"1245_CR18","doi-asserted-by":"publisher","unstructured":"St\u00f6rchle P, M\u00fcller W, Sengeis M, Lackner S, Holasek S, F\u00fcrhapter-Rieger A. Measurement of mean subcutaneous fat thickness: eight standardised ultrasound sites compared to 216 randomly selected sites. Sci Rep. 2018;8. https:\/\/doi.org\/10.1038\/S41598-018-34213-0.","DOI":"10.1038\/S41598-018-34213-0"},{"key":"1245_CR19","doi-asserted-by":"publisher","first-page":"22190","DOI":"10.1109\/JSEN.2021.3110283","volume":"21","author":"P Kassanos","year":"2021","unstructured":"Kassanos P. Bioimpedance sensors: a Tutorial. IEEE Sens J. 2021;21:22190\u2013219. https:\/\/doi.org\/10.1109\/JSEN.2021.3110283.","journal-title":"IEEE Sens J"},{"key":"1245_CR20","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1109\/TBME.2012.2237030","volume":"60","author":"M Jafarpoor","year":"2013","unstructured":"Jafarpoor M, Li J, White JK, Rutkove SB. Optimizing electrode configuration for electrical impedance measurements of muscle via the finite element method. IEEE Trans Biomed Eng. 2013;60:1446\u201352. https:\/\/doi.org\/10.1109\/TBME.2012.2237030.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1245_CR21","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1016\/j.ekir.2022.01.1057","volume":"7","author":"A-L Faucon","year":"2022","unstructured":"Faucon A-L, Flamant M, Delanaye P, Lambert O, Essig M, Peraldi M-N, Tabibzadeh N, Haymann J-P, Stengel B, Geri G, Vidal-Petiot E. Estimating Extracellular Fluid volume in healthy individuals: evaluation of existing formulae and development of a New equation. Kidney Int Rep. 2022;7:810\u201322. https:\/\/doi.org\/10.1016\/j.ekir.2022.01.1057.","journal-title":"Kidney Int Rep"},{"key":"1245_CR22","first-page":"224","volume":"51","author":"SB Nadler","year":"1962","unstructured":"Nadler SB, Hidalgo JH, Bloch T. Prediction of blood volume in normal human adults. Surgery. 1962;51:224\u201332.","journal-title":"Surgery"},{"key":"1245_CR23","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1152\/JAPPL.1974.37.2.247","volume":"37","author":"DB Dill","year":"1974","unstructured":"Dill DB, Costill DL. Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration. J Appl Physiol. 1974;37:247\u20138. https:\/\/doi.org\/10.1152\/JAPPL.1974.37.2.247.","journal-title":"J Appl Physiol"},{"key":"1245_CR24","unstructured":"Pinheiro J, Bates D. (2023) _nlme: Linear and Nonlinear Mixed Effects Models_. R package version 3.1\u2013164."},{"key":"1245_CR25","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1002\/bimj.200810425","volume":"50","author":"T Hothorn","year":"2008","unstructured":"Hothorn T, Bretz F, Westfall P. Simultaneous inference in General Parametric models. Biom J. 2008;50:346\u201363.","journal-title":"Biom J"},{"key":"1245_CR26","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","volume":"17","author":"P Virtanen","year":"2020","unstructured":"Virtanen P, Gommers R, et al. {SciPy} 1.0: Fundamental algorithms for Scientific Computing in Python, version 1.12.0. Nat Methods. 2020;17:261\u201372. https:\/\/doi.org\/10.1038\/s41592-019-0686-2.","journal-title":"Nat Methods"},{"key":"1245_CR27","unstructured":"The pandas development team. (2020) pandas-dev\/pandas: Pandas."},{"key":"1245_CR28","doi-asserted-by":"crossref","unstructured":"Seabold S, Perktold J. (2010) Statsmodels: Econometric and statistical modeling with python. 9th Python in Science Conference.","DOI":"10.25080\/Majora-92bf1922-011"},{"key":"1245_CR29","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1038\/s41586-020-2649-2","volume":"585","author":"CR Harris","year":"2020","unstructured":"Harris CR, Millman KJ, et al. Array programming with {NumPy}, version 1.26.1. Nature. 2020;585:357\u201362. https:\/\/doi.org\/10.1038\/s41586-020-2649-2.","journal-title":"Nature"},{"key":"1245_CR30","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.jss.2006.03.004","volume":"133","author":"JL Wynne","year":"2006","unstructured":"Wynne JL, Ovadje LO, Akridge CM, Sheppard SW, Vogel RL, Van De Water JM. Impedance cardiography: a potential monitor for Hemodialysis. J Surg Res. 2006;133:55\u201360. https:\/\/doi.org\/10.1016\/j.jss.2006.03.004.","journal-title":"J Surg Res"},{"key":"1245_CR31","doi-asserted-by":"publisher","unstructured":"Schoutteten MK, Lindeboom L, De Canni\u00e8re H, Pieters Z, Bruckers L, Brys ADH, van der Heijden P, De Moor B, Peeters J, Van Hoof C, Groenendaal W, Kooman JP, Vandervoort PM. The feasibility of semi-continuous and multi-frequency thoracic bioimpedance measurements by a Wearable device during fluid changes in Hemodialysis patients. Sens (Basel). 2024;24. https:\/\/doi.org\/10.3390\/S24061890.","DOI":"10.3390\/S24061890"},{"key":"1245_CR32","doi-asserted-by":"publisher","unstructured":"Leonov V, Lee S, Londergan A, Martin RA, De Raedt W, Van Hoof C. (2019) Bioimpedance Method for Human Body Hydration Assessment. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 6036\u20136039. https:\/\/doi.org\/10.1109\/EMBC.2019.8857207","DOI":"10.1109\/EMBC.2019.8857207"},{"key":"1245_CR33","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1046\/j.1523-1755.2003.00273.x","volume":"64","author":"N Vasavada","year":"2003","unstructured":"Vasavada N, Agarwal R. Role of excess volume in the pathophysiology of hypertension in chronic kidney disease. Kidney Int. 2003;64:1772\u20139. https:\/\/doi.org\/10.1046\/j.1523-1755.2003.00273.x.","journal-title":"Kidney Int"},{"key":"1245_CR34","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1080\/00365510151097520\/ASSET\/\/CMS\/ASSET\/530DBCB7-C117-43D7-B469-8D89221BE69D\/00365510151097520.FP.PNG","volume":"61","author":"M S\u00f6derberg","year":"2001","unstructured":"S\u00f6derberg M, Hahn RG, Cederholm T. Bioelectric impedance analysis of acute body water changes in congestive heart failure. Scand J Clin Lab Invest. 2001;61:89\u201394. https:\/\/doi.org\/10.1080\/00365510151097520\/ASSET\/\/CMS\/ASSET\/530DBCB7-C117-43D7-B469-8D89221BE69D\/00365510151097520.FP.PNG.","journal-title":"Scand J Clin Lab Invest"},{"key":"1245_CR35","doi-asserted-by":"publisher","first-page":"10895","DOI":"10.3390\/S140610895","volume":"14","author":"SF Khalil","year":"2014","unstructured":"Khalil SF, Mohktar MS, Ibrahim F. The Theory and Fundamentals of Bioimpedance Analysis in Clinical Status monitoring and diagnosis of diseases. Sens (Basel). 2014;14:10895. https:\/\/doi.org\/10.3390\/S140610895.","journal-title":"Sens (Basel)"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-024-01245-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-024-01245-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-024-01245-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,3]],"date-time":"2025-05-03T15:33:28Z","timestamp":1746286408000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-024-01245-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,4]]},"references-count":35,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["1245"],"URL":"https:\/\/doi.org\/10.1007\/s10877-024-01245-z","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,4]]},"assertion":[{"value":"23 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Regional Committees for Medical and Health Research Ethics in Norway (REK KULMU) and the Norwegian Medicines Agency (NoMA). The study complied with the Declaration of Helsinki and was conducted in accordance with ISO14155:2020\u2013 Good clinical practice.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from all participants prior to study enrolment.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publication"}},{"value":"H.N., A.T. and K.R. declare no competing interests. F.B. and S.N.A. are employed by Mode Sensors, the company developing the sensor tested in the clinical investigation. F.B. and S.N.A. also have stock options in the company. J.K. and E.A.J. are former employees and have shares in the company.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}