{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T21:53:15Z","timestamp":1793915595484,"version":"4.8.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T00:00:00Z","timestamp":1752105600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T00:00:00Z","timestamp":1752105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["medtronic internal funding"],"award-info":[{"award-number":["medtronic internal funding"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["medtronic internal funding"],"award-info":[{"award-number":["medtronic internal funding"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["medtronic internal funding"],"award-info":[{"award-number":["medtronic internal funding"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["medtronic internal funding"],"award-info":[{"award-number":["medtronic internal funding"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","award":["medtronic internal funding"],"award-info":[{"award-number":["medtronic internal funding"]}],"id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>We have developed a non-contact (\u201ctouchless\u201d) system based on depth-sensing camera technology for continuous monitoring of respiratory activity. Previous work from our group has demonstrated high accuracy of the system in monitoring a wide range of respiratory rates and signal morphologies across diverse conditions, including variations in lighting, posture, and coverings. Here, we report on the system\u2019s performance in a significantly more challenging anesthesia environment which included a wide range of respiratory rates and respiratory patterns, spontaneous and hand ventilated breathing, patient motion and caregiver interactions in the scene, and, in some cases, the presence of warming blankets covering the torso.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Data was collected opportunistically from 34 healthy volunteers from two separate studies, both of which had the primary objective of investigating the relationship between depth of anesthesia monitoring and anesthetic agents (inhaled and intravenous) across a wide range of anesthetic concentrations and hypnotic states. Depth-sensing information was acquired using an Intel D415 RealSense\u2122 camera and processed to extract frame-by-frame depth changes within the subject\u2019s torso region corresponding to respiratory activity. A respiratory rate (RR\n                      <jats:sub>depth<\/jats:sub>\n                      ) was calculated and output once-per-second from the device. This was compared to a combined reference (RR\n                      <jats:sub>ref<\/jats:sub>\n                      ) derived from both a capnograph and an impedance-based respiratory monitor. Three time periods were evaluated: pre-anesthesia, intra-anesthesia and post-anesthesia.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The overall RMSD accuracy [bias] obtained for the combined data set was 1.92 [0.30] breaths\/min. The performance results stratified according to pre-, intra-, and post-anesthesia stages were 1.71 [0.15], 1.95 [0.39] and 2.13 [0.08] breaths\/min, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>We have demonstrated the ability to continuously track respiratory rate during challenging conditions within an anesthesia setting using our non-contact, touchless, monitoring technology. We believe that our findings support the potential utility for continuous non-contact monitoring of respiration in clinical areas, such as the post-anesthesia care environment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s10877-025-01319-6","type":"journal-article","created":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T10:11:38Z","timestamp":1752142298000},"page":"291-300","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Non-contact (touchless) monitoring of respiratory rate in a challenging anesthesia setting using a depth camera"],"prefix":"10.1007","volume":"40","author":[{"given":"David B.","family":"MacLeod","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Smit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andr\u00e9","family":"Antunes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dean","family":"Montgomery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul S.","family":"Addison","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,10]]},"reference":[{"key":"1319_CR1","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/ALN.0b013e31827773e9","volume":"118","author":"ASA Task Froce on Postanesthetic Care","year":"2013","unstructured":"ASA Task Froce on Postanesthetic Care. ASA Guidelines - Post-Op care. Anesthesiology. 2013;118:291\u2013307.","journal-title":"Anesthesiology"},{"key":"1319_CR2","unstructured":"Flenady T, Dwyer TA, Applegarth JA, Rationalising Transgression. A Grounded Theory Explaining how Emergency Department Registered Nurses Rationalise Erroneous Behaviour. 2016;15:41\u201358."},{"key":"1319_CR3","doi-asserted-by":"publisher","unstructured":"Flenady T, Dwyer T, Applegarth J. Accurate respiratory rates count: So should you! Australas Emerg Nurs J. College of Emergency Nursing Australasia; 2017;20:45\u20137. Available from: https:\/\/doi.org\/10.1016\/j.aenj.2016.12.003","DOI":"10.1016\/j.aenj.2016.12.003"},{"key":"1319_CR4","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1513\/AnnalsATS.201403-102OC","volume":"11","author":"MEB Smith","year":"2014","unstructured":"Smith MEB, Chiovaro JC, O\u2019Neil M, Kansagara D, Qui\u00f1ones AR, Freeman M, et al. Early warning system scores for clinical deterioration in hospitalized patients: A systematic review. Ann Am Thorac Soc. 2014;11:1454\u201365.","journal-title":"Ann Am Thorac Soc"},{"key":"1319_CR5","doi-asserted-by":"publisher","unstructured":"Wibisono E, Hadi U, Bramantono, Arfijanto MV, Rusli M, Rahman BE et al. National early warning score (NEWS) 2 predicts hospital mortality from COVID-19 patients. Ann Med Surg. Elsevier Ltd; 2022;76:103462. Available from: https:\/\/doi.org\/10.1016\/j.amsu.2022.103462","DOI":"10.1016\/j.amsu.2022.103462"},{"key":"1319_CR6","doi-asserted-by":"publisher","unstructured":"Guan G, Lee CMY, Begg S, Crombie A, Mnatzaganian G. The use of early warning system scores in prehospital and emergency department settings to predict clinical deterioration: A systematic review and meta-analysis. PLoS One. 2022;17:1\u201316. Available from: https:\/\/doi.org\/10.1371\/journal.pone.0265559","DOI":"10.1371\/journal.pone.0265559"},{"key":"1319_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/bmjopen-2019-032157","volume":"9","author":"OC Redfern","year":"2019","unstructured":"Redfern OC, Griffiths P, Maruotti A, Recio Saucedo A, Smith GB. The association between nurse staffing levels and the timeliness of vital signs monitoring: A retrospective observational study in the UK. BMJ Open. 2019;9:1\u20138.","journal-title":"BMJ Open"},{"key":"1319_CR8","first-page":"1","volume":"6","author":"P Griffiths","year":"2018","unstructured":"Griffiths P, Ball J, Bloor K, B\u00f6hning D, Briggs J, Dall\u2019Ora C, et al. Nurse staffing levels, missed vital signs and mortality in hospitals: retrospective longitudinal observational study. Heal Serv Deliv Res. 2018;6:1\u2013120.","journal-title":"Heal Serv Deliv Res"},{"key":"1319_CR9","doi-asserted-by":"publisher","unstructured":"Leuvan CHV, Mitchell I. Missed opportunities? An observational study of vital sign measurements. Crit Care Resusc. Elsevier Masson SAS; 2008;10:111\u20135. Available from: https:\/\/doi.org\/10.1016\/S1441-2772(23)01322-4","DOI":"10.1016\/S1441-2772(23)01322-4"},{"key":"1319_CR10","doi-asserted-by":"publisher","unstructured":"Her EL, Nazir S, Pateau V, Visvikis D. Accuracy of noncontact surface imaging for tidal volume and respiratory rate measurements in the ICU. J Clin Monit Comput. Springer Netherlands; 2022;36:775\u201383. Available from: https:\/\/doi.org\/10.1007\/s10877-021-00708-x","DOI":"10.1007\/s10877-021-00708-x"},{"key":"1319_CR11","doi-asserted-by":"crossref","unstructured":"Martinez M, Stiefelhagen R. Breathing rate monitoring during sleep from a depth camera under Real-life conditions. IEEE Winter Conf Apps Comp Vis. 2017;1:1168\u201376.","DOI":"10.1109\/WACV.2017.135"},{"key":"1319_CR12","doi-asserted-by":"crossref","unstructured":"Yu MC, Wu H, Liou JL, Lee MS, Hung YP. Breath and position monitoring during sleeping with a depth camera. Heal 2012 - Proc Int Conf Heal Inf. 2012;1:12\u201322.","DOI":"10.5220\/0003702000120022"},{"key":"1319_CR13","doi-asserted-by":"crossref","unstructured":"Seppanen TM, Kananen J, Noponen K, Alho OP, Seppanen T. Accurate measurement of respiratory airflow waveforms using depth data. Proc Annu Int Conf IEEE Eng Med Biol Soc EMBS. IEEE; 2015;2015-Novem:7857\u201360.","DOI":"10.1109\/EMBC.2015.7320213"},{"key":"1319_CR14","doi-asserted-by":"crossref","unstructured":"Bernacchia N, Scalise L, Casacanditella L, Ercoli I, Marchionni P, Tomasini EP. Non contact measurement of heart and respiration rates based on kinect \u2122. Med Meas Appl IEEE. 2014;1:4\u20138.","DOI":"10.1109\/MeMeA.2014.6860065"},{"key":"1319_CR15","doi-asserted-by":"publisher","unstructured":"Addison AP, Addison PS, Smit P, Jacquel D, Borg UR. Noncontact respiratory monitoring using depth sensing cameras: a review of current literature. Sensors. 2021;4:1\u201316. https:\/\/doi.org\/10.3390\/s21041135","DOI":"10.3390\/s21041135"},{"key":"1319_CR16","doi-asserted-by":"publisher","unstructured":"Addison PS, Cohen C, Borg UR, Antunes A, Montgomery D, Batchelder P. Accurate and continuous respiratory rate using touchless monitoring technology. Respir Med. 2023;220:1\u20137. https:\/\/doi.org\/10.1016\/j.rmed.2023.107463","DOI":"10.1016\/j.rmed.2023.107463"},{"key":"1319_CR17","doi-asserted-by":"publisher","unstructured":"Addison PS, Antunes A, Montgomery D, Smit P, Borg UR. Robust Non-Contact monitoring of respiratory rate using a depth camera. J Clin Monit Comput. 2023;4:1003\u20131010. https:\/\/doi.org\/10.1007\/s10877-023-01003-7","DOI":"10.1007\/s10877-023-01003-7"},{"key":"1319_CR18","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1093\/milmed\/usae200","volume":"18","author":"R Ulf","year":"2024","unstructured":"Ulf RB, Antunes A, Smit P, Addison PS, Montgomery D. Monitoring respiratory rate continuously without attaching a sensor during a challenging ramped protocol. Mil Med. 2024;18:618\u2013623. https:\/\/doi.org\/10.1093\/milmed\/usae200","journal-title":"Mil Med"},{"key":"1319_CR19","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1213\/ANE.0000000000001989","volume":"125","author":"PS Addison","year":"2017","unstructured":"Addison PS, Jacquel D, Foo DMH, Antunes A, Borg UR. Video-Based physiologic monitoring during an acute hypoxic challenge: heart rate, respiratory rate, and oxygen saturation. Anesth Analg. 2017;125:860\u2013873.","journal-title":"Anesth Analg"},{"key":"1319_CR20","doi-asserted-by":"publisher","unstructured":"Addison PS, Brewer L, Sundar KM, Farney R, Smit P, Antunes A, Montgomery D. Non-contact respiratory monitoring during sleep: comparison of the touchless flow signal with ripflow signal to assess respiratory events. J Clin Sleep Med. 2025;21:713\u2013721. https:\/\/doi.org\/10.5664\/jcsm.11486","DOI":"10.5664\/jcsm.11486"},{"key":"1319_CR21","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1109\/JTEHM.2024.3496196","volume":"12","author":"PS Addison","year":"2024","unstructured":"Addison PS, Antunes A, Montgomery D, Borg UR. Non-Contact monitoring of Inhalation-Exhalation (I:E) ratio in Non-Ventilated subjects. IEEE J Transl Eng Heal Med. 2024;12:721\u20136.","journal-title":"IEEE J Transl Eng Heal Med"},{"key":"1319_CR22","doi-asserted-by":"publisher","unstructured":"Mihalj M, Carrel T, Gregoric ID, Andereggen L, Zinn PO, Doll D et al. Telemedicine for preoperative assessment during a COVID-19 pandemic: Recommendations for clinical care. Best Pract Res Clin Anaesthesiol. Elsevier Ltd; 2020;34:345\u201351. Available from: https:\/\/doi.org\/10.1016\/j.bpa.2020.05.001","DOI":"10.1016\/j.bpa.2020.05.001"},{"key":"1319_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphys.2020.00635","volume":"11","author":"C Massaroni","year":"2020","unstructured":"Massaroni C, Nicol\u00f2 A, Schena E, Sacchetti M. Remote respiratory monitoring in the time of COVID-19. Front Physiol. 2020;11:1\u20134.","journal-title":"Front Physiol"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01319-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-025-01319-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01319-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T04:03:47Z","timestamp":1772683427000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-025-01319-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,10]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["1319"],"URL":"https:\/\/doi.org\/10.1007\/s10877-025-01319-6","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,10]]},"assertion":[{"value":"11 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"PSA, DM, PS and AA are all employees of Medtronic, a medical device manufacturer.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}