{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T08:11:14Z","timestamp":1793779874024,"version":"4.6.1"},"reference-count":67,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:00:00Z","timestamp":1753833600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:00:00Z","timestamp":1753833600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-025-01323-w","type":"journal-article","created":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T17:28:39Z","timestamp":1753896519000},"page":"1113-1135","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Non-invasive vs biological blood determination of haemoglobinemia for perioperative management: a systematic review with meta-analysis"],"prefix":"10.1007","volume":"39","author":[{"given":"Lorenna","family":"Moreira","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edgard","family":"Engelman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabel","family":"Estruch-Pons","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maelle","family":"Parvais","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandre","family":"Lecucq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brenda","family":"Martens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre","family":"Pandin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,30]]},"reference":[{"key":"1323_CR1","volume-title":"Guideline on haemoglobin cutoffs to define anaemia in individuals and populations","author":"World Health Organization","year":"2024","unstructured":"World Health Organization. Guideline on haemoglobin cutoffs to define anaemia in individuals and populations. Geneva: World Health Organization; 2024."},{"issue":"3","key":"1323_CR2","first-page":"370","volume":"13","author":"M Mu\u00f1oz","year":"2015","unstructured":"Mu\u00f1oz M, G\u00f3mez-Ram\u00edrez S, Campos A, Ruiz J, Liumbruno GM. Pre-operative anaemia: prevalence, consequences and approaches to management. Blood Transfus. 2015;13(3):370\u20139.","journal-title":"Blood Transfus"},{"issue":"6","key":"1323_CR3","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1016\/j.bja.2018.08.026","volume":"121","author":"AJ Fowler","year":"2018","unstructured":"Fowler AJ, Ahmad T, Abbott TEF, Torrance HD, Wouters PF, De Hert S, et al. Association of preoperative anaemia with postoperative morbidity and mortality: an observational cohort study in low-, middle-, and high-income countries. Br J Anaesth. 2018;121(6):1227\u201335.","journal-title":"Br J Anaesth"},{"issue":"5","key":"1323_CR4","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1213\/ANE.0000000000004727","volume":"130","author":"MA Warner","year":"2020","unstructured":"Warner MA, Shore-Lesserson L, Shander A, Patel SY, Perelman SI, Guinn NR. Perioperative anemia: prevention, diagnosis, and management throughout the spectrum of perioperative care. Anesth Analg. 2020;130(5):1364\u201380.","journal-title":"Anesth Analg"},{"issue":"17","key":"1323_CR5","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1182\/blood-2018-10-833988","volume":"133","author":"R Goel","year":"2019","unstructured":"Goel R, Tobian AAR, Shaz BH. Noninfectious transfusion-associated adverse events and their mitigation strategies. Blood. 2019;133(17):1831\u20139.","journal-title":"Blood"},{"issue":"15","key":"1323_CR6","doi-asserted-by":"publisher","first-page":"3406","DOI":"10.1182\/blood-2008-10-167643","volume":"113","author":"EC Vamvakas","year":"2009","unstructured":"Vamvakas EC, Blajchman MA. Transfusion-related mortality: the ongoing risks of allogeneic blood transfusion and the available strategies for their prevention. Blood. 2009;113(15):3406\u201317.","journal-title":"Blood"},{"issue":"4","key":"1323_CR7","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1097\/EJA.0000000000001803","volume":"40","author":"S Kietaibl","year":"2023","unstructured":"Kietaibl S, Ahmed A, Afshari A, Albaladejo P, Aldecoa C, Barauskas G, et al. Management of severe peri-operative bleeding: guidelines from the European Society of Anaesthesiology and Intensive Care: Second update 2022. Eur J Anaesthesiol. 2023;40(4):226\u2013304.","journal-title":"Eur J Anaesthesiol"},{"key":"1323_CR8","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1111\/ijlh.14254","volume":"46","author":"CL Harteveld","year":"2024","unstructured":"Harteveld CL, McCafferty R, Fawcett T, Erber WN. International Council for the Standardization of Haematology (ICSH). International Council for Standardization in Haematology technical report 2023: renewal of the reference material for haemiglobincyanide 19-1-B308 for use in standardization of blood haemoglobin measurements. Int J Lab Hematol. 2024;46:575\u20136.","journal-title":"Int J Lab Hematol"},{"issue":"2","key":"1323_CR9","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1111\/trf.17237","volume":"63","author":"KD Hornedo-Gonz\u00e1lez","year":"2023","unstructured":"Hornedo-Gonz\u00e1lez KD, Jacob AK, Burt JM, Higgins AA, Engel EM, Hanson AC, et al. Non-invasive hemoglobin estimation for preoperative anemia screening. Transfusion. 2023;63(2):315\u201322.","journal-title":"Transfusion"},{"issue":"1","key":"1323_CR10","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s13643-020-01542-z","volume":"10","author":"ML Rethlefsen","year":"2021","unstructured":"Rethlefsen ML, Kirtley S, Waffenschmidt S, Ayala AP, Moher D, Page MJ, Koffel JB, PRISMA-S Group. PRISMA-S: an extension to the PRISMA statement for reporting literature searches in systematic reviews. Syst Rev. 2021;10(1):39.","journal-title":"Syst Rev"},{"key":"1323_CR11","unstructured":"Lefebvre C, Glanville J, Briscoe S, Featherstone R, Littlewood A, Metzendorf M-I, Noel-Storr A, Paynter R, Rader T, Thomas J, Wieland LS. Chapter 4: Searching for and selecting studies. In: Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors).\u00a0Cochrane Handbook for Systematic Reviews of Interventions\u00a0version 6.5. Cochrane, 2024."},{"issue":"1","key":"1323_CR12","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1159\/000526100","volume":"120","author":"SK Panda","year":"2023","unstructured":"Panda SK, Mishra A, Jena PK. Agreement between noninvasive hemoglobin and laboratory hemoglobin measurements in neonates: a systematic review and meta-analysis. Neonatology. 2023;120(1):24\u201332.","journal-title":"Neonatology"},{"key":"1323_CR13","doi-asserted-by":"publisher","first-page":"3826","DOI":"10.1093\/eurheartj\/ehac270","volume":"43","author":"S Halvorsen","year":"2022","unstructured":"Halvorsen S, Mehilli J, Cassese S, Hall TS, Abdelhamid M, Barbato E, et al. 2022 ESC guidelines on cardiovascular assessment and management of patients undergoing non-cardiac surgery. Eur Heart J. 2022;43:3826\u2013924.","journal-title":"Eur Heart J"},{"issue":"8","key":"1323_CR14","doi-asserted-by":"publisher","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","volume":"155","author":"PF Whiting","year":"2011","unstructured":"Whiting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529\u201336.","journal-title":"Ann Intern Med"},{"issue":"2","key":"1323_CR15","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1213\/ANE.0000000000000272","volume":"119","author":"SH Kim","year":"2014","unstructured":"Kim SH, Lilot M, Murphy LS, Sidhu KS, Yu Z, Rinehart J, et al. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg. 2014;119(2):332\u201346.","journal-title":"Anesth Analg"},{"key":"1323_CR16","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571\u201382.","journal-title":"J Biopharm Stat"},{"issue":"4","key":"1323_CR17","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.revmed.2013.07.011","volume":"35","author":"G Moulis","year":"2014","unstructured":"Moulis G, Sommet A. Comment lire une m\u00e9ta-analyse? [How to read a meta-analysis?]. Rev Med Interne. 2014;35(4):250\u20138.","journal-title":"Rev Med Interne"},{"issue":"5","key":"1323_CR18","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1213\/ANE.0b013e3181f08a5b","volume":"111","author":"LA Critchley","year":"2010","unstructured":"Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111(5):1180\u201392.","journal-title":"Anesth Analg"},{"issue":"3","key":"1323_CR19","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1053\/j.jvca.2011.01.003","volume":"25","author":"LA Critchley","year":"2011","unstructured":"Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth. 2011;25(3):536\u201346.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"1","key":"1323_CR20","doi-asserted-by":"publisher","first-page":"5072","DOI":"10.1038\/s41598-024-55837-5","volume":"14","author":"SB Yoon","year":"2024","unstructured":"Yoon SB, Jung CW, Kim T, Lee HC. Effect of hyperbilirubinemia on the accuracy of continuous non-invasive hemoglobin measurements in liver transplantation recipients. Sci Rep. 2024;14(1):5072.","journal-title":"Sci Rep"},{"issue":"9","key":"1323_CR21","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.4187\/respcare.10399","volume":"68","author":"AN Aggarwal","year":"2023","unstructured":"Aggarwal AN, Agarwal R, Dhooria S, Prasad KT, Sehgal IS, Muthu V. Impact of fingernail polish on pulse oximetry measurements: a systematic review. Respir Care. 2023;68(9):1271\u201380.","journal-title":"Respir Care"},{"issue":"8","key":"1323_CR22","doi-asserted-by":"publisher","first-page":"432","DOI":"10.11622\/smedj.2019031","volume":"60","author":"JLJ Yek","year":"2019","unstructured":"Yek JLJ, Abdullah HR, Goh JPS, Chan YW. The effects of gel-based manicure on pulse oximetry. Singapore Med J. 2019;60(8):432\u20135.","journal-title":"Singapore Med J"},{"issue":"1","key":"1323_CR23","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.resuscitation.2006.11.018","volume":"74","author":"J Hinkelbein","year":"2007","unstructured":"Hinkelbein J, Koehler H, Genzwuerker HV, Fiedler F. Artificial acrylic finger nails may alter pulse oximetry measurement. Resuscitation. 2007;74(1):75\u201382.","journal-title":"Resuscitation"},{"issue":"2","key":"1323_CR24","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1213\/ANE.0000000000000605","volume":"122","author":"SJ Barker","year":"2016","unstructured":"Barker SJ, Shander A, Ramsay MA. Continuous noninvasive hemoglobin monitoring: a measured response to a critical review. Anesth Analg. 2016;122(2):565-72.22.","journal-title":"Anesth Analg"},{"issue":"5","key":"1323_CR25","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.3390\/s18051367","volume":"18","author":"B Ribed-S\u00e1nchez","year":"2018","unstructured":"Ribed-S\u00e1nchez B, Gonz\u00e1lez-Gaya C, Varea-D\u00edaz S, Corbacho-Fabregat C, P\u00e9rez-Oteyza J, Belda-Iniesta C. Economic analysis of the reduction of blood transfusions during surgical procedures while continuous hemoglobin monitoring is used. Sensors (Basel). 2018;18(5):1367.","journal-title":"Sensors (Basel)"},{"issue":"5","key":"1323_CR26","doi-asserted-by":"publisher","first-page":"349","DOI":"10.2106\/JBJS.O.00820","volume":"98","author":"JR Martin","year":"2016","unstructured":"Martin JR, Camp CL, Stitz A, Young EY, Abdel MP, Taunton MJ, Trousdale RT. Noninvasive hemoglobin monitoring: a rapid, reliable, and cost-effective method following total joint replacement. J Bone Joint Surg Am. 2016;98(5):349\u201355.","journal-title":"J Bone Joint Surg Am"},{"key":"1323_CR27","doi-asserted-by":"publisher","first-page":"237","DOI":"10.4172\/2155-9864.1000237","volume":"5","author":"JM Ehrenfeld","year":"2014","unstructured":"Ehrenfeld JM, Henneman JP, Bulka CM, Sandberg WS. Continuous non-invasive hemoglobin monitoring during orthopedic surgery: a randomized trial. J Blood Disorders Transf. 2014;5:237.","journal-title":"J Blood Disorders Transf"},{"issue":"10","key":"1323_CR28","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.29271\/jcpsp.2022.10.1242","volume":"32","author":"S Akdag","year":"2022","unstructured":"Akdag S, Zengin SU, Cakmak G, Umuroglu T, Aykac ZZ, Saracoglu A. Targeted bleeding management guided by non-invasive haemoglobin measurement in surgical patients. J Coll Physicians Surg Pak. 2022;32(10):1242\u20138.","journal-title":"J Coll Physicians Surg Pak"},{"issue":"6","key":"1323_CR29","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1213\/ANE.0b013e318230b425","volume":"113","author":"L Berkow","year":"2011","unstructured":"Berkow L, Rotolo S, Mirski E. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011;113(6):1396\u2013402.","journal-title":"Anesth Analg"},{"issue":"5","key":"1323_CR30","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1016\/j.amjsurg.2011.01.020","volume":"201","author":"MW Causey","year":"2011","unstructured":"Causey MW, Miller S, Foster A, Beekley A, Zenger D, Martin M. Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station. Am J Surg. 2011;201(5):592\u20138.","journal-title":"Am J Surg"},{"issue":"3","key":"1323_CR31","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1097\/ALN.0b013e3182270c22","volume":"115","author":"L Lamhaut","year":"2011","unstructured":"Lamhaut L, Apriotesei R, Combes X, Lejay M, Carli P, Vivien B. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue\u00ae with automated laboratory hemoglobin measurement. Anesthesiology. 2011;115(3):548\u201354.","journal-title":"Anesthesiology"},{"issue":"4","key":"1323_CR32","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1213\/ANE.0b013e31820eecd1","volume":"112","author":"RD Miller","year":"2011","unstructured":"Miller RD, Ward TA, Shiboski SC, Cohen NH. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg. 2011;112(4):858\u201363.","journal-title":"Anesth Analg"},{"issue":"5","key":"1323_CR33","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1213\/ANE.0b013e31822c9679","volume":"113","author":"BV Nguyen","year":"2011","unstructured":"Nguyen BV, Vincent JL, Nowak E, Coat M, Paleiron N, Gouny P, et al. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg. 2011;113(5):1052\u20137.","journal-title":"Anesth Analg"},{"issue":"1","key":"1323_CR34","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1097\/ALN.0b013e31823d774f","volume":"116","author":"RL Applegate 2nd","year":"2012","unstructured":"Applegate RL 2nd, Barr SJ, Collier CE, Rook JL, Mangus DB, Allard MW. Evaluation of pulse cooximetry in patients undergoing abdominal or pelvic surgery. Anesthesiology. 2012;116(1):65\u201372.","journal-title":"Anesthesiology"},{"issue":"2","key":"1323_CR35","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1093\/bja\/aer373","volume":"108","author":"A Butwick","year":"2012","unstructured":"Butwick A, Hilton G, Carvalho B. Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section. Br J Anaesth. 2012;108(2):271\u20137.","journal-title":"Br J Anaesth"},{"issue":"2","key":"1323_CR36","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s10877-012-9335-3","volume":"26","author":"DA Colquhoun","year":"2012","unstructured":"Colquhoun DA, Forkin KT, Durieux ME, Thiele RH. Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin. J Clin Monit Comput. 2012;26(2):69\u201373.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"1323_CR37","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1213\/ANE.0b013e31826b7e38","volume":"115","author":"YH Park","year":"2012","unstructured":"Park YH, Lee JH, Song HG, Byon HJ, Kim HS, Kim JT. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery. Anesth Analg. 2012;115(6):1302\u20137.","journal-title":"Anesth Analg"},{"issue":"4","key":"1323_CR38","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1093\/bja\/aes234","volume":"109","author":"JJ Vos","year":"2012","unstructured":"Vos JJ, Kalmar AF, Struys MM, Porte RJ, Wietasch JK, Scheeren TW, et al. Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery. Br J Anaesth. 2012;109(4):522\u20138.","journal-title":"Br J Anaesth"},{"issue":"6","key":"1323_CR39","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1093\/bja\/aet252","volume":"111","author":"B Giraud","year":"2013","unstructured":"Giraud B, Frasca D, Debaene B, Mimoz O. Comparison of haemoglobin measurement methods in the operating theatre. Br J Anaesth. 2013;111(6):946\u201354.","journal-title":"Br J Anaesth"},{"issue":"1","key":"1323_CR40","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/s10877-012-9397-2","volume":"27","author":"T Isosu","year":"2013","unstructured":"Isosu T, Obara S, Hosono A, Ohashi S, Nakano Y, Imaizumi T, et al. Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput. 2013;27(1):55\u201360.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1323_CR41","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1111\/anae.12039","volume":"68","author":"VA Skelton","year":"2013","unstructured":"Skelton VA, Wijayasinghe N, Sharafudeen S, Sange A, Parry NS, Junghans C. Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7\u2122 pulse co-oximetry, HemoCue(\u00ae) and laboratory haemoglobin measurements in obstetric patients*. Anaesthesia. 2013;68(1):40\u20135.","journal-title":"Anaesthesia"},{"issue":"4","key":"1323_CR42","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1177\/0885066613485355","volume":"29","author":"E Dewhirst","year":"2014","unstructured":"Dewhirst E, Naguib A, Winch P, Rice J, Galantowicz M, McConnell P, et al. Accuracy of noninvasive and continuous hemoglobin measurement by pulse co-oximetry during preoperative phlebotomy. J Intensive Care Med. 2014;29(4):238\u201342.","journal-title":"J Intensive Care Med"},{"issue":"4","key":"1323_CR43","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1213\/ANE.0000000000000369","volume":"119","author":"M Patino","year":"2014","unstructured":"Patino M, Schultz L, Hossain M, Moeller J, Mahmoud M, Gunter J, et al. Trending and accuracy of noninvasive hemoglobin monitoring in pediatric perioperative patients. Anesth Analg. 2014;119(4):920\u20135.","journal-title":"Anesth Analg"},{"issue":"8","key":"1323_CR44","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/j.jclinane.2014.04.012","volume":"26","author":"K Yamaura","year":"2014","unstructured":"Yamaura K, Nanishi N, Higashi M, Hoka S. Effects of thermoregulatory vasoconstriction on pulse hemoglobin measurements using a co-oximeter in patients undergoing surgery. J Clin Anesth. 2014;26(8):643\u20137.","journal-title":"J Clin Anesth"},{"issue":"3","key":"1323_CR45","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1080\/22201173.2014.936749","volume":"20","author":"P Khanna","year":"2014","unstructured":"Khanna P, Rajagopalan V, Singh G, Prabhakar H. A comparison of non-invasive versus invasive methods of haemoglobin estimation in patients undergoing intracranial surgery. South Afr J Anaesth Analg. 2014;20(3):160\u20133.","journal-title":"South Afr J Anaesth Analg"},{"issue":"9","key":"1323_CR46","doi-asserted-by":"publisher","first-page":"1813","DOI":"10.1016\/j.joms.2014.03.011","volume":"72","author":"SH Kim","year":"2014","unstructured":"Kim SH, Choi JM, Kim HJ, Choi SS, Choi IC. Continuous noninvasive hemoglobin measurement is useful in patients undergoing double-jaw surgery. J Oral Maxillofac Surg. 2014;72(9):1813\u20139.","journal-title":"J Oral Maxillofac Surg"},{"issue":"6","key":"1323_CR47","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1007\/s10877-015-9660-4","volume":"29","author":"WN Awada","year":"2015","unstructured":"Awada WN, Mohmoued MF, Radwan TM, Hussien GZ, Elkady HW. Continuous and noninvasive hemoglobin monitoring reduces red blood cell transfusion during neurosurgery: a prospective cohort study. J Clin Monit Comput. 2015;29(6):733\u201340.","journal-title":"J Clin Monit Comput"},{"issue":"7","key":"1323_CR48","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1111\/anae.13028","volume":"70","author":"D Frasca","year":"2015","unstructured":"Frasca D, Mounios H, Giraud B, Boisson M, Debaene B, Mimoz O. Continuous monitoring of haemoglobin concentration after in-vivo adjustment in patients undergoing surgery with blood loss. Anaesthesia. 2015;70(7):803\u20139.","journal-title":"Anaesthesia"},{"issue":"1","key":"1323_CR49","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s00540-014-1863-1","volume":"29","author":"J Saito","year":"2015","unstructured":"Saito J, Kitayama M, Oishi M, Kudo T, Sawada M, Hashimoto H, Hirota K. The accuracy of non-invasively continuous total hemoglobin measurement by pulse CO-Oximetry undergoing acute normovolemic hemodilution and reinfusion of autologous blood. J Anesth. 2015;29(1):29\u201334.","journal-title":"J Anesth"},{"issue":"4","key":"1323_CR50","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/j.transproceed.2015.12.121","volume":"48","author":"PH Huang","year":"2016","unstructured":"Huang PH, Shih BF, Tsai YF, Chung PC, Liu FC, Yu HP, et al. Accuracy and trending of continuous noninvasive hemoglobin monitoring in patients undergoing liver transplantation. Transplant Proc. 2016;48(4):1067\u201370.","journal-title":"Transplant Proc"},{"issue":"5","key":"1323_CR51","doi-asserted-by":"publisher","first-page":"1167","DOI":"10.1053\/j.jvca.2016.03.148","volume":"30","author":"ML Riess","year":"2016","unstructured":"Riess ML, Pagel PS. Noninvasively measured hemoglobin concentration reflects arterial hemoglobin concentration before but not after cardiopulmonary bypass in patients undergoing coronary artery or valve surgery. J Cardiothorac Vasc Anesth. 2016;30(5):1167\u201371.","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"1","key":"1323_CR52","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s10877-015-9816-2","volume":"31","author":"W Baulig","year":"2017","unstructured":"Baulig W, Seifert B, Spahn DR, Theusinger OM. Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients. J Clin Monit Comput. 2017;31(1):177\u201385.","journal-title":"J Clin Monit Comput"},{"issue":"5","key":"1323_CR53","doi-asserted-by":"publisher","first-page":"485","DOI":"10.23736\/S0375-9393.17.11652-4","volume":"83","author":"G Erdogan Kayhan","year":"2017","unstructured":"Erdogan Kayhan G, Colak YZ, Sanli M, Ucar M, Toprak HI. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation. Minerva Anestesiol. 2017;83(5):485\u201392.","journal-title":"Minerva Anestesiol"},{"issue":"7","key":"1323_CR54","doi-asserted-by":"publisher","first-page":"543","DOI":"10.4103\/ija.IJA_707_16","volume":"61","author":"N Gupta","year":"2017","unstructured":"Gupta N, Kulkarni A, Bhargava AK, Prakash A, Gupta N. Utility of non-invasive haemoglobin monitoring in oncosurgery patients. Indian J Anaesth. 2017;61(7):543\u20138.","journal-title":"Indian J Anaesth"},{"issue":"6","key":"1323_CR55","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1007\/s10877-018-0101-z","volume":"32","author":"A Adel","year":"2018","unstructured":"Adel A, Awada W, Abdelhamid B, Omar H, Abd El Dayem O, Hasanin A, et al. Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses. J Clin Monit Comput. 2018;32(6):1025\u201331.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1323_CR56","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1186\/s12871-019-0790-y","volume":"19","author":"FC Chang","year":"2019","unstructured":"Chang FC, Lin JR, Liu FC. Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study. BMC Anesthesiol. 2019;19(1):117.","journal-title":"BMC Anesthesiol"},{"issue":"4","key":"1323_CR57","doi-asserted-by":"publisher","first-page":"423","DOI":"10.17085\/apm.2019.14.4.423","volume":"14","author":"H Kim","year":"2019","unstructured":"Kim H, Do SH, Hwang JW, Na HS. Intraoperative continuous noninvasive hemoglobin monitoring in patients with placenta previa undergoing cesarean section: a prospective observational study. Anesth Pain Med (Seoul). 2019;14(4):423\u20138.","journal-title":"Anesth Pain Med (Seoul)"},{"issue":"1","key":"1323_CR58","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1186\/s12871-019-0755-1","volume":"19","author":"B Tang","year":"2019","unstructured":"Tang B, Yu X, Xu L, Zhu A, Zhang Y, Huang Y. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiol. 2019;19(1):80.","journal-title":"BMC Anesthesiol"},{"issue":"5","key":"1323_CR59","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1007\/s10877-019-00428-3","volume":"34","author":"RL Applegate 2nd","year":"2020","unstructured":"Applegate RL 2nd, Applegate PM, Cannesson M, Peiris P, Ladlie BL, Torp K. Multicenter comparison of three intraoperative hemoglobin trend monitoring methods. J Clin Monit Comput. 2020;34(5):883\u201392.","journal-title":"J Clin Monit Comput"},{"issue":"3","key":"1323_CR60","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1007\/s10877-019-00337-5","volume":"34","author":"RC De Rosa","year":"2020","unstructured":"De Rosa RC, Romano GM, Abbate R, Corcione A, De Robertis E. Accuracy and trending ability of hemoglobin measurement by the Pulse CO-Oximeter during vascular surgery. J Clin Monit Comput. 2020;34(3):501\u20138.","journal-title":"J Clin Monit Comput"},{"issue":"3","key":"1323_CR61","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1213\/ANE.0000000000004323","volume":"130","author":"\u015eI Bubenek-Turconi","year":"2020","unstructured":"Bubenek-Turconi \u015eI, V\u0103leanu L, Popescu M, Panaitescu E, Tomescu D, Cacoveanu MC, et al. Continuous noninvasive hemoglobin monitoring reflects the development of acute hemodilution after consecutive fluid challenges. Anesth Analg. 2020;130(3):696\u2013703.","journal-title":"Anesth Analg"},{"issue":"27","key":"1323_CR62","volume":"27","author":"HS Lee","year":"2021","unstructured":"Lee HS, Yoo JW, Kim HY, Kim NY, Kim JE. Accuracy of continuous and noninvasive hemoglobin monitoring in the presence of CO2 insufflation: an observational pilot study. Med Sci Monit. 2021;27(27): e933027.","journal-title":"Med Sci Monit"},{"issue":"Suppl 2","key":"1323_CR63","doi-asserted-by":"publisher","first-page":"S62","DOI":"10.4103\/ija.IJA_1067_20","volume":"65","author":"N Selvaraj","year":"2021","unstructured":"Selvaraj N, Jain G, Tripathy DK, Mittal A, Indulekha H. Accuracy of non-invasive haemoglobin measurements in patients undergoing transurethral resection of prostate surgery. Indian J Anaesth. 2021;65(Suppl 2):S62\u20138.","journal-title":"Indian J Anaesth"},{"issue":"2","key":"1323_CR64","doi-asserted-by":"publisher","first-page":"103","DOI":"10.5114\/ait.2021.105658","volume":"53","author":"A Spronk","year":"2021","unstructured":"Spronk A, de Jong R, Koopman S, Hoeks S, Jan SR. Blood transfusion decisions cannot be based on percutaneous haemoglobin measurements. Anaesthesiol Intensive Ther. 2021;53(2):103\u20137.","journal-title":"Anaesthesiol Intensive Ther"},{"issue":"1","key":"1323_CR65","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1080\/11101849.2022.2153976","volume":"38","author":"MI Beleta","year":"2022","unstructured":"Beleta MI, Abdallah SR, Hammad YM, Mostafa Yahia HE, ElMawgood Ali AA, Mohamed AA, et al. Noninvasive continuous hemoglobin monitoring of blood transfusion in obstetric procedures. Egypt J Anaesth. 2022;38(1):701\u20138.","journal-title":"Egypt J Anaesth"},{"issue":"2","key":"1323_CR66","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3390\/jpm12020160","volume":"12","author":"HY Kim","year":"2022","unstructured":"Kim HY, Choi JB, Han SU, Lee HS, Lee K, Kim JE. Impact of increased end-tidal carbon dioxide on continuous noninvasive hemoglobin monitoring during laparoscopic gastrectomy: a randomized controlled study. J Pers Med. 2022;12(2):160.","journal-title":"J Pers Med"},{"key":"1323_CR67","doi-asserted-by":"publisher","first-page":"111326","DOI":"10.1016\/j.jclinane.2023.111326","volume":"93","author":"SK Park","year":"2024","unstructured":"Park SK, Hur C, Kim YW, Yoo S, Lim YJ, Kim JT. Noninvasive hemoglobin monitoring for maintaining hemoglobin concentration within the target range during major noncardiac surgery: a randomized controlled trial. J Clin Anesth. 2024;93:111326.","journal-title":"J Clin Anesth"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01323-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-025-01323-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01323-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T05:02:31Z","timestamp":1764824551000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-025-01323-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,30]]},"references-count":67,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1323"],"URL":"https:\/\/doi.org\/10.1007\/s10877-025-01323-w","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,30]]},"assertion":[{"value":"16 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}