{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T05:11:47Z","timestamp":1775452307324,"version":"3.50.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Beijing Hospitals Authority\u2019s Ascent Plan","award":["DFL20220203"],"award-info":[{"award-number":["DFL20220203"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-025-01348-1","type":"journal-article","created":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T05:26:16Z","timestamp":1756790776000},"page":"567-574","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["iThermonitor: A wearable non-invasive high-precision alternative to traditional temperature monitoring in thoracoscopic surgery of lateral decubitus position"],"prefix":"10.1007","volume":"40","author":[{"given":"Yanhong","family":"Yan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiao","family":"Geng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xu","family":"Cui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhihai","family":"Ju","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guyan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,2]]},"reference":[{"issue":"8","key":"1348_CR1","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1093\/cid\/cir1033","volume":"54","author":"KB Laupland","year":"2012","unstructured":"Laupland KB, Zahar J, Adrie C, et al. Severe hypothermia increases the risk for intensive care unit-acquired infection. Clin Infect Dis. 2012;54(8):1064\u201370. https:\/\/doi.org\/10.1093\/cid\/cir1033.","journal-title":"Clin Infect Dis"},{"issue":"3","key":"1348_CR2","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1093\/bja\/aen233","volume":"101","author":"CM Harper","year":"2008","unstructured":"Harper CM, Andrzejowski JC, Alexander R. NICE and warm. Br J Anaesth. 2008;101(3):293\u20135. https:\/\/doi.org\/10.1093\/bja\/aen233.","journal-title":"Br J Anaesth"},{"issue":"6","key":"1348_CR3","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s12630-017-0845-9","volume":"64","author":"S Boet","year":"2017","unstructured":"Boet S, Patey AM, Baron JS, et al. Factors that influence effective perioperative temperature management by anesthesiologists: a qualitative study using the theoretical domains framework. Can J Anaesth. 2017;64(6):581\u201396. https:\/\/doi.org\/10.1007\/s12630-017-0845-9.","journal-title":"Can J Anaesth"},{"issue":"4","key":"1348_CR4","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1111\/j.1744-1609.2011.00227.x","volume":"9","author":"S Moola","year":"2011","unstructured":"Moola S, Lockwood C. Effectiveness of strategies for the management and\/or prevention of hypothermia within the adult perioperative environment. Int J Evid Based Healthc. 2011;9(4):337\u201345. https:\/\/doi.org\/10.1111\/j.1744-1609.2011.00227.x.","journal-title":"Int J Evid Based Healthc"},{"issue":"2","key":"1348_CR5","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.ijnurstu.2013.05.013","volume":"51","author":"Y Pu","year":"2014","unstructured":"Pu Y, Cen G, Sun J, et al. Warming with an underbody warming system reduces intraoperative hypothermia in patients undergoing laparoscopic gastrointestinal surgery: a randomized controlled study. Int J Nurs Stud. 2014;51(2):181\u20139. https:\/\/doi.org\/10.1016\/j.ijnurstu.2013.05.013.","journal-title":"Int J Nurs Stud"},{"issue":"3","key":"1348_CR6","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2015-009913","volume":"6","author":"N Klauke","year":"2016","unstructured":"Klauke N, Graff I, Fleischer A, et al. Effects of prehospital hypothermia on transfusion requirements and outcomes: a retrospective observatory trial. BMJ Open. 2016;6(3): e009913. https:\/\/doi.org\/10.1136\/bmjopen-2015-009913.","journal-title":"BMJ Open"},{"issue":"2","key":"1348_CR7","first-page":"155","volume":"67","author":"CB Mahoney","year":"1999","unstructured":"Mahoney CB, Odom J. Maintaining intraoperative normothermia: a meta-analysis of outcomes with costs. AANA J. 1999;67(2):155\u201363.","journal-title":"AANA J"},{"issue":"10","key":"1348_CR8","doi-asserted-by":"publisher","first-page":"768","DOI":"10.7326\/M15-1150","volume":"163","author":"DJ Niven","year":"2015","unstructured":"Niven DJ, Gaudet JE, Laupland KB, et al. Accuracy of peripheral thermometers for estimating temperature: a systematic review and meta-analysis. Ann Intern Med. 2015;163(10):768\u201377. https:\/\/doi.org\/10.7326\/M15-1150.","journal-title":"Ann Intern Med"},{"issue":"19","key":"1348_CR9","doi-asserted-by":"publisher","DOI":"10.3390\/s22197639","volume":"22","author":"CM Dolson","year":"2022","unstructured":"Dolson CM, Harlow ER, Phelan DM, et al. Wearable sensor technology to predict core body temperature: a systematic review. Sensors. 2022;22(19): 7639. https:\/\/doi.org\/10.3390\/s22197639.","journal-title":"Sensors"},{"issue":"1","key":"1348_CR10","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s10877-022-00851-z","volume":"37","author":"A Brauer","year":"2023","unstructured":"Brauer A, Fazliu A, Brandes IF, et al. Evaluation of the Temple Touch Pro noninvasive core-temperature monitoring system in 100 adults under general anesthesia: a prospective comparison with esophageal temperature. J Clin Monit Comput. 2023;37(1):29\u201336. https:\/\/doi.org\/10.1007\/s10877-022-00851-z.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1348_CR11","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-022-01853-9","volume":"22","author":"S Yang","year":"2022","unstructured":"Yang S, Cho H, Kim H. Comparison of tracheal temperature and core temperature measurement in living donor liver transplant recipients: a clinical comparative study. BMC Anesthesiol. 2022;22(1): 315. https:\/\/doi.org\/10.1186\/s12871-022-01853-9.","journal-title":"BMC Anesthesiol"},{"issue":"1","key":"1348_CR12","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-78753-w","volume":"10","author":"A Brauer","year":"2020","unstructured":"Brauer A, Fazliu A, Perl T, et al. Accuracy of zero-heat-flux thermometry and bladder temperature measurement in critically ill patients. Sci Rep. 2020;10(1): 21746. https:\/\/doi.org\/10.1038\/s41598-020-78753-w.","journal-title":"Sci Rep"},{"issue":"11","key":"1348_CR13","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/EJA.0000000000000822","volume":"35","author":"M Boisson","year":"2018","unstructured":"Boisson M, Alaux A, Kerforne T, et al. Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M spoton) in comparison with oesophageal and arterial temperature: a prospective observational study. Eur J Anaesthesiol. 2018;35(11):825\u201330. https:\/\/doi.org\/10.1097\/EJA.0000000000000822.","journal-title":"Eur J Anaesthesiol"},{"issue":"1","key":"1348_CR14","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1213\/ANE.0000000000001695","volume":"125","author":"S Evron","year":"2017","unstructured":"Evron S, Weissman A, Toivis V, et al. Evaluation of the Temple Touch Pro, a novel noninvasive core-temperature monitoring system. Anesth Analg. 2017;125(1):103\u20139. https:\/\/doi.org\/10.1213\/ANE.0000000000001695.","journal-title":"Anesth Analg"},{"issue":"3","key":"1348_CR15","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1213\/ANE.0000000000002706","volume":"126","author":"L Pei","year":"2018","unstructured":"Pei L, Huang Y, Mao G, et al. Axillary temperature, as recorded by the iThermonitor WT701, well represents core temperature in adults having noncardiac surgery. Anesth Analg. 2018;126(3):833\u20138. https:\/\/doi.org\/10.1213\/ANE.0000000000002706.","journal-title":"Anesth Analg"},{"issue":"1","key":"1348_CR16","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s12871-023-01991-8","volume":"23","author":"R Xu","year":"2023","unstructured":"Xu R, Hu X, Sun Z, et al. Incidence of postoperative hypothermia and shivering and risk factors in patients undergoing malignant tumor surgery: a retrospective study. BMC Anesthesiol. 2023;23(1):31. https:\/\/doi.org\/10.1186\/s12871-023-01991-8.","journal-title":"BMC Anesthesiol"},{"issue":"6","key":"1348_CR17","doi-asserted-by":"publisher","first-page":"1979","DOI":"10.1016\/j.jtcvs.2023.10.031","volume":"167","author":"CM Stuart","year":"2024","unstructured":"Stuart CM, Dyas AR, Bronsert MR, et al. Perioperative hypothermia in robotic-assisted thoracic surgery: Incidence, risk factors, and associations with postoperative outcomes. J Thorac Cardiovasc Surg. 2024;167(6):1979-1989.e1. https:\/\/doi.org\/10.1016\/j.jtcvs.2023.10.031.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"1348_CR18","doi-asserted-by":"publisher","unstructured":"Mekjavic IB, Rempel ME. Determination of esophageal probe insertion length based on standing and sitting height. J Appl Physiol (1985). 1990;69(1):376-9. https:\/\/doi.org\/10.1152\/jappl.1990.69.1.376","DOI":"10.1152\/jappl.1990.69.1.376"},{"issue":"1","key":"1348_CR19","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1213\/ANE.0000000000002326","volume":"126","author":"L du Toit","year":"2018","unstructured":"du Toit L, van Dyk D, Hofmeyr R, et al. Core temperature monitoring in obstetric spinal anesthesia using an ingestible telemetric sensor. Anesth Analg. 2018;126(1):190\u20135. https:\/\/doi.org\/10.1213\/ANE.0000000000002326.","journal-title":"Anesth Analg"},{"issue":"10038","key":"1348_CR20","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","volume":"387","author":"DI Sessler","year":"2016","unstructured":"Sessler DI. Perioperative thermoregulation and heat balance. Lancet. 2016;387(10038):2655\u201364. https:\/\/doi.org\/10.1016\/S0140-6736(15)00981-2.","journal-title":"Lancet"},{"issue":"3","key":"1348_CR21","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1016\/j.bja.2017.11.091","volume":"120","author":"S Min","year":"2018","unstructured":"Min S, Yoon S, Yoon S, et al. Randomised trial comparing forced-air warming to the upper or lower body to prevent hypothermia during thoracoscopic surgery in the lateral decubitus position. Br J Anaesth. 2018;120(3):555\u201362. https:\/\/doi.org\/10.1016\/j.bja.2017.11.091.","journal-title":"Br J Anaesth"},{"key":"1348_CR22","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2021.717269","volume":"12","author":"J Wittenstein","year":"2021","unstructured":"Wittenstein J, Scharffenberg M, Ran X, et al. Effects of body position and hypovolemia on the regional distribution of pulmonary perfusion during one-lung ventilation in endotoxemic pigs. Front Physiol. 2021;12: 717269. https:\/\/doi.org\/10.3389\/fphys.2021.717269.","journal-title":"Front Physiol"},{"key":"1348_CR23","doi-asserted-by":"publisher","first-page":"1204531","DOI":"10.3389\/fphys.2023.1204531","volume":"14","author":"J Wittenstein","year":"2023","unstructured":"Wittenstein J, Scharffenberg M, Yang X, et al. Distribution of transpulmonary pressure during one-lung ventilation in pigs at different body positions. Front Physiol. 2023;14:1204531. https:\/\/doi.org\/10.3389\/fphys.2023.1204531.","journal-title":"Front Physiol"},{"issue":"6","key":"1348_CR24","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1016\/j.jopan.2021.02.008","volume":"36","author":"Y Ji","year":"2021","unstructured":"Ji Y, Han D, Han L, et al. The accuracy of a wireless axillary thermometer for core temperature monitoring in pediatric patients having noncardiac surgery: an observational study. J Perianesth Nurs. 2021;36(6):685\u20139. https:\/\/doi.org\/10.1016\/j.jopan.2021.02.008.","journal-title":"J Perianesth Nurs"},{"issue":"11","key":"1348_CR25","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2020-039474","volume":"10","author":"Y Liu","year":"2020","unstructured":"Liu Y, Liu C, Gao M, et al. Evaluation of a wearable wireless device with artificial intelligence, iThermonitor WT705, for continuous temperature monitoring for patients in surgical wards: a prospective comparative study. BMJ Open. 2020;10(11): e039474. https:\/\/doi.org\/10.1136\/bmjopen-2020-039474.","journal-title":"BMJ Open"},{"issue":"4","key":"1348_CR26","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1093\/bja\/aeq018","volume":"104","author":"AF Kalmar","year":"2010","unstructured":"Kalmar AF, Foubert L, Hendrickx JFA, et al. Influence of steep Trendelenburg position and CO(2) pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy. Br J Anaesth. 2010;104(4):433\u20139. https:\/\/doi.org\/10.1093\/bja\/aeq018.","journal-title":"Br J Anaesth"},{"issue":"3","key":"1348_CR27","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1097\/00000542-199509000-00007","volume":"83","author":"A Kurz","year":"1995","unstructured":"Kurz A, Sessler DI, Christensen R, et al. Heat balance and distribution during the core-temperature plateau in anesthetized humans. Anesthesiology. 1995;83(3):491\u20139. https:\/\/doi.org\/10.1097\/00000542-199509000-00007.","journal-title":"Anesthesiology"},{"issue":"4","key":"1348_CR28","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1093\/clinchem\/39.4.561","volume":"39","author":"MH Zweig","year":"1993","unstructured":"Zweig MH, Campbell G. Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine. Clin Chem. 1993;39(4):561\u201377.","journal-title":"Clin Chem"},{"issue":"10337","key":"1348_CR29","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/S0140-6736(22)00560-8","volume":"399","author":"DI Sessler","year":"2022","unstructured":"Sessler DI, Pei L, Li K, et al. Aggressive intraoperative warming versus routine thermal management during non-cardiac surgery (PROTECT): a multicentre, parallel group, superiority trial. Lancet. 2022;399(10337):1799\u2013808. https:\/\/doi.org\/10.1016\/S0140-6736(22)00560-8.","journal-title":"Lancet"},{"issue":"1","key":"1348_CR30","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/ALN.0000000000003481","volume":"134","author":"DI Sessler","year":"2021","unstructured":"Sessler DI. Perioperative temperature monitoring. Anesthesiology. 2021;134(1):111\u20138. https:\/\/doi.org\/10.1097\/ALN.0000000000003481.","journal-title":"Anesthesiology"},{"issue":"1","key":"1348_CR31","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/s10877-022-00899-x","volume":"37","author":"N Aagaard","year":"2023","unstructured":"Aagaard N, Larsen AT, Aasvang EK, et al. The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence. J Clin Monit Comput. 2023;37(1):7\u201317. https:\/\/doi.org\/10.1007\/s10877-022-00899-x.","journal-title":"J Clin Monit Comput"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01348-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-025-01348-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01348-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T03:49:31Z","timestamp":1775447371000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-025-01348-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,2]]},"references-count":31,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["1348"],"URL":"https:\/\/doi.org\/10.1007\/s10877-025-01348-1","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,2]]},"assertion":[{"value":"17 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"The clinical trial number is ChiCTR2300078340, and it is registered with the Chinese Clinical Trial Registration website, which can be accessed at Chinese Clinical Trial Register (ChiCTR).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}