{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T05:11:45Z","timestamp":1775452305694,"version":"3.50.1"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Burn shock is a major early complication in the treatment of severely burned patients, and precise and timely fluid management is essential for survival. Traditional clinical indicators such as urine output, blood pressure, central venous pressure (CVP), and blood lactate are commonly used, but each has significant limitations. Invasive hemodynamic monitoring technologies, such as Pulmonary Artery Catheterization (PAC) and Pulse Contour Cardiac Output (PiCCO), have improved the accuracy of fluid assessment, but carry risks of infection and procedural complications and require experienced clinical interpretation within the context of the patient\u2019s overall condition. Non-invasive ultrasound-based methods, including critical care ultrasonography and the Venous Excess Ultrasound Score (VExUS), are emerging as promising alternatives, particularly in resource-limited settings. This review summarizes current methods for fluid management in severely burned patients, with a focus on the concepts of fluid responsiveness and fluid tolerance, and provides recommendations for clinical practice.<\/jats:p>","DOI":"10.1007\/s10877-025-01365-0","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T05:48:30Z","timestamp":1760593710000},"page":"417-427","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Fluid management methods for severely burned patients: a narrative review"],"prefix":"10.1007","volume":"40","author":[{"given":"Yi","family":"Yao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianzhen","family":"Hua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yucong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meiqing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"issue":"1","key":"1365_CR1","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1038\/s41572-020-0145-5IF","volume":"6","author":"MG Jeschke","year":"2020","unstructured":"Jeschke MG, van Baar ME, Choudhry MA, Chung KK, Gibran NS, Logsetty S. Burn injury. Nat Rev Dis Primers. 2020;6(1):11. https:\/\/doi.org\/10.1038\/s41572-020-0145-5IF. Published 2020 Feb 13.","journal-title":"Nat Rev Dis Primers"},{"issue":"4","key":"1365_CR2","doi-asserted-by":"publisher","first-page":"2847","DOI":"10.3892\/etm.2019.7240","volume":"17","author":"Y Zheng","year":"2019","unstructured":"Zheng Y, Lin G, Zhan R, et al. Epidemiological analysis of 9,779 burn patients in China: an eight-year retrospective study at a major burn center in Southwest China. Exp Ther Med. 2019;17(4):2847\u201354. https:\/\/doi.org\/10.3892\/etm.2019.7240.","journal-title":"Exp Ther Med"},{"key":"1365_CR3","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.addr.2017.09.019","volume":"123","author":"AA Udy","year":"2018","unstructured":"Udy AA, Roberts JA, Lipman J, Blot S. The effects of major burn related pathophysiological changes on the pharmacokinetics and pharmacodynamics of drug use: an appraisal utilizing antibiotics. Adv Drug Deliv Rev. 2018;123:65\u201374. https:\/\/doi.org\/10.1016\/j.addr.2017.09.019.","journal-title":"Adv Drug Deliv Rev"},{"issue":"1","key":"1365_CR4","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.kint.2018.11.047","volume":"96","author":"JL Vincent","year":"2019","unstructured":"Vincent JL. Fluid management in the critically ill. Kidney Int. 2019;96(1):52\u20137. https:\/\/doi.org\/10.1016\/j.kint.2018.11.047.","journal-title":"Kidney Int"},{"issue":"1","key":"1365_CR5","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s13613-016-0216-7","volume":"6","author":"X Monnet","year":"2016","unstructured":"Monnet X, Marik PE, Teboul JL. Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016;6(1):111. https:\/\/doi.org\/10.1186\/s13613-016-0216-7.","journal-title":"Ann Intensive Care"},{"issue":"2","key":"1365_CR6","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1186\/cc12526","volume":"17","author":"X Monnet","year":"2013","unstructured":"Monnet X, Teboul JL. Assessment of volume responsiveness during mechanical ventilation: recent advances. Crit Care. 2013;17(2):217. https:\/\/doi.org\/10.1186\/cc12526. Published 2013 Mar 19.","journal-title":"Crit Care"},{"issue":"12","key":"1365_CR7","doi-asserted-by":"publisher","first-page":"1935","DOI":"10.1007\/s00134-015-4134-1","volume":"42","author":"X Monnet","year":"2016","unstructured":"Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42(12):1935\u201347. https:\/\/doi.org\/10.1007\/s00134-015-4134-1.","journal-title":"Intensive Care Med"},{"issue":"1","key":"1365_CR8","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s13613-020-00682-8","volume":"10","author":"F Gavelli","year":"2020","unstructured":"Gavelli F, Shi R, Teboul JL, Azzolina D, Monnet X. The end-expiratory occlusion test for detecting preload responsiveness: a systematic review and meta-analysis. Ann Intensive Care. 2020;10(1):65. https:\/\/doi.org\/10.1186\/s13613-020-00682-8. Published 2020 May 24.","journal-title":"Ann Intensive Care"},{"issue":"1","key":"1365_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-023-04424-7","volume":"27","author":"C Lai","year":"2023","unstructured":"Lai C, Shi R, Beurton A, et al. The increase in cardiac output induced by a decrease in positive end-expiratory pressure reliably detects volume responsiveness: the PEEP-test study. Crit Care. 2023;27(1):136. https:\/\/doi.org\/10.1186\/s13054-023-04424-7.","journal-title":"Crit Care"},{"issue":"1","key":"1365_CR10","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1186\/s13054-023-04363-3","volume":"27","author":"X Monnet","year":"2023","unstructured":"Monnet X, Lai C, Teboul JL. How i personalize fluid therapy in septic shock? Crit Care. 2023;27(1):123. https:\/\/doi.org\/10.1186\/s13054-023-04363-3. (Published 2023 Mar 24).","journal-title":"Crit Care"},{"issue":"2","key":"1365_CR11","doi-asserted-by":"publisher","first-page":"89","DOI":"10.5603\/AIT.a2014.0068","volume":"47","author":"PJ Hofkens","year":"2015","unstructured":"Hofkens PJ, Verrijcken A, Merveille K, et al. Common pitfalls and tips and tricks to get the most out of your transpulmonary thermodilution device: results of a survey and state-of-the-art review. Anaesthesiol Intensive Ther. 2015;47(2):89\u2013116. https:\/\/doi.org\/10.5603\/AIT.a2014.0068.","journal-title":"Anaesthesiol Intensive Ther"},{"issue":"7","key":"1365_CR12","doi-asserted-by":"publisher","first-page":"868","DOI":"10.1007\/s00134-023-07101-z","volume":"49","author":"A Pesenti","year":"2023","unstructured":"Pesenti A, Slobod D, Magder S. The forgotten relevance of central venous pressure monitoring. Intensive Care Med. 2023;49(7):868\u201370. https:\/\/doi.org\/10.1007\/s00134-023-07101-z.","journal-title":"Intensive Care Med"},{"issue":"3","key":"1365_CR13","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1002\/ppul.24635","volume":"55","author":"HF Zong","year":"2020","unstructured":"Zong HF, Guo G, Liu J, Bao LL, Yang CZ. Using lung ultrasound to quantitatively evaluate pulmonary water content. Pediatr Pulmonol. 2020;55(3):729\u201339. https:\/\/doi.org\/10.1002\/ppul.24635.","journal-title":"Pediatr Pulmonol"},{"issue":"27","key":"1365_CR14","doi-asserted-by":"publisher","first-page":"2097","DOI":"10.1093\/eurheartj\/ehw164","volume":"37","author":"E Picano","year":"2016","unstructured":"Picano E, Pellikka PA. Ultrasound of extravascular lung water: a new standard for pulmonary congestion. Eur Heart J. 2016;37(27):2097\u2013104. https:\/\/doi.org\/10.1093\/eurheartj\/ehw164.","journal-title":"Eur Heart J"},{"issue":"1","key":"1365_CR15","doi-asserted-by":"publisher","first-page":"29","DOI":"10.3760\/cma.j.issn.1009-2587.2018.01.006","volume":"34","author":"QL Zeng","year":"2018","unstructured":"Zeng QL, Wang QM, Li N, Luo QZ, Zhonghua. Shao Shang Za Zhi. 2018;34(1):29\u201331. https:\/\/doi.org\/10.3760\/cma.j.issn.1009-2587.2018.01.006.","journal-title":"Shao Shang Za Zhi"},{"issue":"1","key":"1365_CR16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1186\/s13054-018-2171-1","volume":"22","author":"S Magder","year":"2018","unstructured":"Magder S. The meaning of blood pressure. Crit Care. 2018;22(1):257. https:\/\/doi.org\/10.1186\/s13054-018-2171-1. Published 2018 Oct 11.","journal-title":"Crit Care"},{"key":"1365_CR17","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1007\/s00134-015-4168-4","volume":"42","author":"TG Eskesen","year":"2016","unstructured":"Eskesen TG, Wetterslev M, Perner A. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness. Intensive Care Med. 2016;42:324\u201332. https:\/\/doi.org\/10.1007\/s00134-015-4168-4.","journal-title":"Intensive Care Med"},{"key":"1365_CR18","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1186\/s13054-014-0587-9","volume":"18","author":"M Biais","year":"2014","unstructured":"Biais M, Ehrmann S, Mari A, Conte B, Mahjoub Y, Desebbe O, et al. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach. Crit Care. 2014;18:587. https:\/\/doi.org\/10.1186\/s13054-014-0587-9.","journal-title":"Crit Care"},{"issue":"6","key":"1365_CR19","doi-asserted-by":"publisher","first-page":"R278","DOI":"10.1186\/cc13133","volume":"17","author":"M Legrand","year":"2013","unstructured":"Legrand M, Dupuis C, Simon C, et al. Association between systemic hemodynamics and septic acute kidney injury in critically ill patients: a retrospective observational study. Crit Care. 2013;17(6):R278. https:\/\/doi.org\/10.1186\/cc13133. Published 2013 Nov 29.","journal-title":"Crit Care"},{"issue":"1","key":"1365_CR20","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s13054-018-1959-3","volume":"22","author":"D De Backer","year":"2018","unstructured":"De Backer D, Vincent JL. Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions. Crit Care. 2018;22(1):43. https:\/\/doi.org\/10.1186\/s13054-018-1959-3. Published 2018 Feb 23.","journal-title":"Crit Care"},{"key":"1365_CR21","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1097\/CCM.0000000000001941","volume":"44","author":"MW Semler","year":"2016","unstructured":"Semler MW, Wheeler AP, Thompson BT, Bernard GR, Wiedemann HP, Rice TW. Impact of initial central venous pressure on outcomes of Conservative versus Liberal fluid management in acute respiratory distress syndrome. Crit Care Med. 2016;44:782\u20139. https:\/\/doi.org\/10.1097\/CCM.0000000000001941.","journal-title":"Crit Care Med"},{"issue":"Supplement_1","key":"1365_CR22","doi-asserted-by":"publisher","DOI":"10.1093\/qjmed\/hcad069.688","volume":"116","author":"SN Mohammed","year":"2023","unstructured":"Mohammed SN, Amin MA. Evaluation of Blood Lactate Concentrations as a Marker for Resuscitation and Prognosis in Patients with Major Burns. QJM: An International Journal of Medicine. 2023;(Supplement_1):hcad069.688. https:\/\/doi.org\/10.1093\/qjmed\/hcad069.688.","journal-title":"QJM: An International Journal of Medicine"},{"key":"1365_CR23","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s13613-014-0030-z","volume":"4","author":"G Hernandez","year":"2014","unstructured":"Hernandez G, Luengo C, Bruhn A, et al. When to stop septic shock resuscitation: clues from a dynamic perfusion monitoring. Ann Intensive Care. 2014;4:30. https:\/\/doi.org\/10.1186\/s13613-014-0030-z. Published 2014 Oct 11.","journal-title":"Ann Intensive Care"},{"key":"1365_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.iccn.2024.103743","volume":"84","author":"W Huang","year":"2024","unstructured":"Huang W, Huang Y, Ke L, Hu C, Chen P, Hu B. Perspectives for capillary refill time in clinical practice for sepsis. Intensive Crit Care Nurs. 2024;84:103743. https:\/\/doi.org\/10.1016\/j.iccn.2024.103743.","journal-title":"Intensive Crit Care Nurs"},{"issue":"1","key":"1365_CR25","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-96806-6","volume":"11","author":"B Nassar","year":"2021","unstructured":"Nassar B, Badr M, Van Grunderbeeck N, et al. Central venous-to-arterial PCO2 difference as a marker to identify fluid responsiveness in septic shock. Sci Rep. 2021;11(1):17256. https:\/\/doi.org\/10.1038\/s41598-021-96806-6.","journal-title":"Sci Rep"},{"issue":"6","key":"1365_CR26","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1097\/SHK.0000000000001442","volume":"53","author":"R Ronfl\u00e9","year":"2020","unstructured":"Ronfl\u00e9 R, Lefebvre L, Duclos G, et al. Venous-to-arterial carbon dioxide partial pressure difference: predictor of septic patient prognosis depending on central venous oxygen saturation. Shock. 2020;53(6):710\u20136. https:\/\/doi.org\/10.1097\/SHK.0000000000001442.","journal-title":"Shock"},{"issue":"6","key":"1365_CR27","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-014-0579-9","volume":"18","author":"P Squara","year":"2014","unstructured":"Squara P. Central venous oxygenation: when physiology explains apparent discrepancies. Crit Care. 2014;18(6):579. https:\/\/doi.org\/10.1186\/s13054-014-0579-9.","journal-title":"Crit Care"},{"issue":"9","key":"1365_CR28","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1056\/NEJM197008272830902","volume":"283","author":"HJ Swan","year":"1970","unstructured":"Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283(9):447\u201351. https:\/\/doi.org\/10.1056\/NEJM197008272830902.","journal-title":"N Engl J Med"},{"issue":"9","key":"1365_CR29","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1007\/s00134-016-4375-7","volume":"42","author":"JL Teboul","year":"2016","unstructured":"Teboul JL, Saugel B, Cecconi M, et al. Less invasive hemodynamic monitoring in critically ill patients. Intensive Care Med. 2016;42(9):1350\u20139. https:\/\/doi.org\/10.1007\/s00134-016-4375-7.","journal-title":"Intensive Care Med"},{"issue":"1","key":"1365_CR30","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s10877-021-00673-5","volume":"36","author":"IT Bootsma","year":"2022","unstructured":"Bootsma IT, Boerma EC, Scheeren TWL, de Lange F. The contemporary pulmonary artery catheter. Part 2: measurements, limitations, and clinical applications. J Clin Monit Comput. 2022;36(1):17\u201331. https:\/\/doi.org\/10.1007\/s10877-021-00673-5.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"1365_CR31","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1007\/s00134-018-5110-3","volume":"44","author":"JL Teboul","year":"2018","unstructured":"Teboul JL, Cecconi M, Scheeren TWL. Is there still a place for the Swan-Ganz catheter? No. Intensive Care Med. 2018;44(6):957\u20139. https:\/\/doi.org\/10.1007\/s00134-018-5110-3.","journal-title":"Intensive Care Med"},{"issue":"6","key":"1365_CR32","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1186\/s13054-014-0650-6","volume":"18","author":"X Yang","year":"2014","unstructured":"Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18(6):650. https:\/\/doi.org\/10.1186\/s13054-014-0650-6. Published 2014 Nov 27.","journal-title":"Crit Care"},{"issue":"4","key":"1365_CR33","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1093\/bja\/aet116","volume":"111","author":"K Bendjelid","year":"2013","unstructured":"Bendjelid K, Marx G, Kiefer N, et al. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients. Br J Anaesth. 2013;111(4):573\u20139. https:\/\/doi.org\/10.1093\/bja\/aet116.","journal-title":"Br J Anaesth"},{"issue":"1","key":"1365_CR34","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.bja.2020.09.049","volume":"126","author":"B Saugel","year":"2021","unstructured":"Saugel B, Kouz K, Scheeren TWL, et al. Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review. Br J Anaesth. 2021;126(1):67\u201376. https:\/\/doi.org\/10.1016\/j.bja.2020.09.049.","journal-title":"Br J Anaesth"},{"issue":"11","key":"1365_CR35","doi-asserted-by":"publisher","first-page":"776","DOI":"10.3760\/cma.j.issn.1009-2587.2018.11.011","volume":"34","author":"WY Zhang","year":"2018","unstructured":"Burn and Trauma Branch of Chinese Geriatrics Society, Zhang WY, Wang W. Zhonghua Shao Shang Za Zhi. 2018;34(11):776\u201381. https:\/\/doi.org\/10.3760\/cma.j.issn.1009-2587.2018.11.011.","journal-title":"Zhonghua Shao Shang Za Zhi"},{"issue":"3","key":"1365_CR36","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1213\/ANE.0b013e3181cc885a","volume":"110","author":"DA Reuter","year":"2010","unstructured":"Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg. 2010;110(3):799\u2013811. https:\/\/doi.org\/10.1213\/ANE.0b013e3181cc885a.","journal-title":"Anesth Analg"},{"issue":"1","key":"1365_CR37","doi-asserted-by":"publisher","DOI":"10.1186\/2047-0525-2-19","volume":"2","author":"C Chamos","year":"2013","unstructured":"Chamos C, Vele L, Hamilton M, Cecconi M. Less invasive methods of advanced hemodynamic monitoring: principles, devices, and their role in the perioperative hemodynamic optimization. Perioper Med (Lond). 2013;2(1):19. https:\/\/doi.org\/10.1186\/2047-0525-2-19.","journal-title":"Perioper Med (Lond)"},{"issue":"10","key":"1365_CR38","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1097\/EJA.0000000000001227","volume":"37","author":"G Greiwe","year":"2020","unstructured":"Greiwe G, Luehsen K, Hapfelmeier A, et al. Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution: a method comparison study after off-pump coronary artery bypass surgery. Eur J Anaesthesiol. 2020;37(10):920\u20135. https:\/\/doi.org\/10.1097\/EJA.0000000000001227.","journal-title":"Eur J Anaesthesiol"},{"issue":"3","key":"1365_CR39","doi-asserted-by":"publisher","DOI":"10.1186\/cc6933","volume":"12","author":"CK Hofer","year":"2008","unstructured":"Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified flotrac and PiCCOplus system. Crit Care. 2008;12(3):R82. https:\/\/doi.org\/10.1186\/cc6933.","journal-title":"Crit Care"},{"issue":"5","key":"1365_CR40","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1097\/ALN.0b013e31824f94ed","volume":"116","author":"JR Martina","year":"2012","unstructured":"Martina JR, Westerhof BE, van Goudoever J, et al. Noninvasive continuous arterial blood pressure monitoring with Nexfin\u00ae. Anesthesiology. 2012;116(5):1092\u2013103. https:\/\/doi.org\/10.1097\/ALN.0b013e31824f94ed.","journal-title":"Anesthesiology"},{"issue":"4","key":"1365_CR41","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1007\/s10877-015-9744-1","volume":"30","author":"JY Wagner","year":"2016","unstructured":"Wagner JY, Grond J, Fortin J, Negulescu I, Sch\u00f6fthaler M, Saugel B. Continuous noninvasive cardiac output determination using the CNAP system: evaluation of a cardiac output algorithm for the analysis of volume clamp method-derived pulse contour. J Clin Monit Comput. 2016;30(4):487\u201393. https:\/\/doi.org\/10.1007\/s10877-015-9744-1.","journal-title":"J Clin Monit Comput"},{"issue":"9","key":"1365_CR42","doi-asserted-by":"publisher","first-page":"1691","DOI":"10.7863\/ultra.15.14.08059","volume":"34","author":"P Blanco","year":"2015","unstructured":"Blanco P, Aguiar FM, Blaivas M. Rapid ultrasound in shock (RUSH) velocity-time integral: a proposal to expand the RUSH protocol. J Ultrasound Med. 2015;34(9):1691\u2013700. https:\/\/doi.org\/10.7863\/ultra.15.14.08059.","journal-title":"J Ultrasound Med"},{"issue":"6","key":"1365_CR43","doi-asserted-by":"publisher","first-page":"2505","DOI":"10.26355\/eurrev_201903_17398","volume":"23","author":"C Huan","year":"2019","unstructured":"Huan C, Lu C, Song B, et al. The shape change index (SCI) of inferior vena cava (IVC) measuring by transabdominal ultrasound to predict the presence of septic shock in intensive care unit (ICU) patients. Eur Rev Med Pharmacol Sci. 2019;23(6):2505\u201312. https:\/\/doi.org\/10.26355\/eurrev_201903_17398.","journal-title":"Eur Rev Med Pharmacol Sci"},{"issue":"8","key":"1365_CR44","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1164\/rccm.201604-0844OC","volume":"195","author":"P Vignon","year":"2017","unstructured":"Vignon P, Repess\u00e9 X, B\u00e9got E, et al. Comparison of echocardiographic indices used to predict fluid responsiveness in ventilated patients. Am J Respir Crit Care Med. 2017;195(8):1022\u201332. https:\/\/doi.org\/10.1164\/rccm.201604-0844OC.","journal-title":"Am J Respir Crit Care Med"},{"issue":"11","key":"1365_CR45","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1097\/CCM.0000000000006399","volume":"52","author":"J Basmaji","year":"2024","unstructured":"Basmaji J, Arntfield R, Desai K, et al. The impact of point-of-care ultrasound-guided resuscitation on clinical outcomes in patients with shock: a systematic review and meta-analysis. Crit Care Med. 2024;52(11):1661\u201373. https:\/\/doi.org\/10.1097\/CCM.0000000000006399.","journal-title":"Crit Care Med"},{"issue":"3","key":"1365_CR46","doi-asserted-by":"publisher","first-page":"e0262053","DOI":"10.1371\/journal.pone.0262053","volume":"17","author":"JC Jentzer","year":"2022","unstructured":"Jentzer JC, Wiley BM, Anavekar NS. Echocardiographic left ventricular stroke work index: an integrated noninvasive measure of shock severity. PLoS ONE. 2022;17(3):e0262053. https:\/\/doi.org\/10.1371\/journal.pone.0262053. Published 2022 Mar 9.","journal-title":"PLoS ONE"},{"issue":"3","key":"1365_CR47","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1053\/j.ackd.2021.03.003","volume":"28","author":"J Suarez","year":"2021","unstructured":"Suarez J, Niyyar VD. Lung ultrasound. A biomarker for fluid overload? Adv Chronic Kidney Dis. 2021;28(3):200\u20137. https:\/\/doi.org\/10.1053\/j.ackd.2021.03.003.","journal-title":"Adv Chronic Kidney Dis"},{"issue":"1","key":"1365_CR48","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1186\/s13054-024-05102-y","volume":"28","author":"M Beshara","year":"2024","unstructured":"Beshara M, Bittner EA, Goffi A, Berra L, Chang MG. Nuts and bolts of lung ultrasound: utility, scanning techniques, protocols, and findings in common pathologies. Crit Care. 2024;28(1):328. https:\/\/doi.org\/10.1186\/s13054-024-05102-y. Published 2024 Oct 7.","journal-title":"Crit Care"},{"issue":"6","key":"1365_CR49","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1378\/chest.14-1313","volume":"147","author":"DA Lichtenstein","year":"2015","unstructured":"Lichtenstein DA. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill. Chest. 2015;147(6):1659\u201370. https:\/\/doi.org\/10.1378\/chest.14-1313.","journal-title":"Chest"},{"issue":"1","key":"1365_CR50","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13089-020-00163-w","volume":"12","author":"W Beaubien-Souligny","year":"2020","unstructured":"Beaubien-Souligny W, Rola P, Haycock K, et al. Quantifying systemic congestion with point-of-care ultrasound: development of the venous excess ultrasound grading system. Ultrasound J. 2020;12(1):16. https:\/\/doi.org\/10.1186\/s13089-020-00163-w. (Published 2020 Apr 9).","journal-title":"Ultrasound J"},{"issue":"1","key":"1365_CR51","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1186\/s13054-023-04524-4","volume":"27","author":"S Andrei","year":"2023","unstructured":"Andrei S, Bahr PA, Nguyen M, Bouhemad B, Guinot PG. Prevalence of systemic venous congestion assessed by venous excess ultrasound grading system (VExUS) and association with acute kidney injury in a general ICU cohort: a prospective multicentric study. Crit Care. 2023;27(1):224. https:\/\/doi.org\/10.1186\/s13054-023-04524-4. Published 2023 Jun 8.","journal-title":"Crit Care"},{"issue":"3","key":"1365_CR52","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1016\/j.chest.2023.09.029","volume":"165","author":"A Longino","year":"2024","unstructured":"Longino A, Martin K, Leyba K, et al. Prospective evaluation of venous excess ultrasound for estimation of venous congestion. Chest. 2024;165(3):590\u2013600. https:\/\/doi.org\/10.1016\/j.chest.2023.09.029.","journal-title":"Chest"},{"issue":"1","key":"1365_CR53","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1186\/s13054-023-04471-0","volume":"27","author":"A Longino","year":"2023","unstructured":"Longino A, Martin K, Leyba K, et al. Correlation between the vexus score and right atrial pressure: a pilot prospective observational study. Crit Care. 2023;27(1):205. https:\/\/doi.org\/10.1186\/s13054-023-04471-0. Published 2023 May 26.","journal-title":"Crit Care"},{"issue":"1","key":"1365_CR54","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.accpm.2016.05.007","volume":"36","author":"C Roger","year":"2017","unstructured":"Roger C, Sadek M, Bastide S, et al. Comparison of the visualisation of the subclavian and axillary veins: an ultrasound study in healthy volunteers. Anaesth Crit Care Pain Med. 2017;36(1):65\u20138. https:\/\/doi.org\/10.1016\/j.accpm.2016.05.007.","journal-title":"Anaesth Crit Care Pain Med"},{"issue":"1","key":"1365_CR55","doi-asserted-by":"publisher","first-page":"44","DOI":"10.4103\/1817-1737.146872","volume":"10","author":"A Kent","year":"2015","unstructured":"Kent A, Patil P, Davila V, et al. Sonographic evaluation of intravascular volume status: can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization? Ann Thorac Med. 2015;10(1):44\u20139. https:\/\/doi.org\/10.4103\/1817-1737.146872.","journal-title":"Ann Thorac Med"},{"issue":"5","key":"1365_CR56","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1136\/emermed-2016-205944","volume":"35","author":"K Molokoane-Mokgoro","year":"2018","unstructured":"Molokoane-Mokgoro K, Goldstein LN, Wells M. Ultrasound evaluation of the respiratory changes of the inferior vena cava and axillary vein diameter at rest and during positive pressure ventilation in spontaneously breathing healthy volunteers. Emerg Med J. 2018;35(5):297\u2013302. https:\/\/doi.org\/10.1136\/emermed-2016-205944.","journal-title":"Emerg Med J"},{"issue":"2","key":"1365_CR57","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57020187","volume":"57","author":"D Boehm","year":"2021","unstructured":"Boehm D, Menke H. A history of fluid management-from one size fits all to an individualized fluid therapy in burn resuscitation. Medicina (Kaunas). 2021;57(2):187. https:\/\/doi.org\/10.3390\/medicina57020187.","journal-title":"Medicina (Kaunas)"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01365-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-025-01365-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01365-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T03:49:30Z","timestamp":1775447370000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-025-01365-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,16]]},"references-count":57,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["1365"],"URL":"https:\/\/doi.org\/10.1007\/s10877-025-01365-0","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,16]]},"assertion":[{"value":"3 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.\u00a0","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"There are no human participants in this article and informed consent is not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}