{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T05:11:53Z","timestamp":1775452313640,"version":"3.50.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T00:00:00Z","timestamp":1763078400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T00:00:00Z","timestamp":1763078400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Functional testers are designed to evaluate select pulse oximeter characteristics but are often misused to validate device accuracy, potentially providing false reassurance. This study evaluated whether the Fluke ProSim8 (FPS8) could accurately predict oximeter performance during human controlled desaturation studies or identify performance differences under low signal conditions. 12 oximeters were tested using two FPS8 protocols: (1) an \u2018SpO\u2082 plateau\u2019 protocol which mimicked controlled desaturation studies by evaluating device performance over a range of simulated SpO\n                    <jats:sub>2<\/jats:sub>\n                    (70\u2013100%), and (2) a \u2018signal space\u2019 protocol designed to assess device accuracy under varying modulation and transmission conditions. Each device also underwent controlled desaturation testing in healthy adults.\u00a0Six of the 12 oximeters passed (ARMS\u2009\n                    <jats:italic>\u2264<\/jats:italic>\n                    \u20093%) the SpO\u2082 plateau protocol; however, three of these failed (ARMS\u2009&gt;\u20093%) human testing. At lower simulated saturations, most devices overestimated SpO\u2082. In the signal space protocol, oximeters performed well under high signal conditions, but many failed to produce readings or showed SpO\u2082 errors\u2009&gt;\u20093% under low signal conditions. On average, oximeters failed to generate a reading 20.2\u2009\u00b1\u20097.2 times out of 60 attempts. Ten devices passed (ARMS\u2009&lt;\u20093%) the signal space protocol, but two of these failed human testing. Oximeter performance on the FPS8 did not correlate with human performance (R\u00b2 = 0.08 for the plateau protocol; R\u00b2 = 0.01 for the signal space protocol).\u00a0The FPS8 did not reliably predict oximeter accuracy in human desaturation studies or under low signal conditions; current functional tester protocols are limited in predicting real-world oximeter performance.\n                  <\/jats:p>","DOI":"10.1007\/s10877-025-01381-0","type":"journal-article","created":{"date-parts":[[2025,11,14]],"date-time":"2025-11-14T15:07:10Z","timestamp":1763132830000},"page":"457-468","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparing pulse oximeter performance using a common functional tester versus controlled desaturation studies on healthy participants"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-0566-7960","authenticated-orcid":false,"given":"Seif","family":"Elmankabadi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jake","family":"Dove","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ella","family":"Behnke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-9907-0306","authenticated-orcid":false,"given":"Yu Celine","family":"Chou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lily","family":"Ortiz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregory","family":"Leeb","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isabella","family":"Auchus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danni","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Feiner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tyler J.","family":"Law","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip E.","family":"Bickler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shamsudini","family":"Hashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ren\u00e9 Vargas","family":"Zamora","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fekir","family":"Negussie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6567-1735","authenticated-orcid":false,"given":"Ronald","family":"Bisegerwa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Bernstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9978-1465","authenticated-orcid":false,"given":"Michael S.","family":"Lipnick","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,14]]},"reference":[{"key":"1381_CR1","unstructured":"Fluke Biomedical. ProSim 8 Vital Signs Simulator Users Manual [Internet]. Fluke Biomedical; [cited 2025 Feb 19]. https:\/\/www.flukebiomedical.com\/sites\/default\/files\/resources\/prosim8_umeng0300.pdf. Accessed 19 Feb 2025."},{"key":"1381_CR2","unstructured":"Fluke Biomedical. SPOT Light SpO2 Functional Tester Users Manual [Internet]. Fluke Biomedical; [cited 2025 Feb 19]. https:\/\/www.flukebiomedical.com\/sites\/default\/files\/prosimspot_umeng_0200.pdf. Accessed 19 Feb 2025."},{"key":"1381_CR3","unstructured":"Fluke Biomedical. Index 2XL SpO2 Simulator Users Manual [Internet]. Fluke Biomedical; [cited 2025 Feb 19]. https:\/\/www.flukebiomedical.com\/sites\/default\/files\/resources\/index2xlumeng0000_0.pdf. Accessed 19 Feb 2025."},{"key":"1381_CR4","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1007\/s10877-023-01031-3","volume":"37","author":"R Gylys","year":"2023","unstructured":"Gylys R, Feiner J, Pologe J, Delianides T, Sutter S, Bickler P, et al. Quantifying pulse oximeter accuracy during hypoxemia and severe anemia using an in vitro circulation system. J Clin Monit Comput. 2023;37:1441\u20139. https:\/\/doi.org\/10.1007\/s10877-023-01031-3.","journal-title":"J Clin Monit Comput"},{"key":"1381_CR5","unstructured":"PPG-2R-880,. PPG-2R-940 Reflectance SpO2 Module_Oximeter Device Testing_Products [Internet]. WhaleTeq. [cited 2025 Feb 19]. https:\/\/www.whaleteq.com\/en\/product\/3\/15-oximeter-device-testing\/view20-ppg-2r-880-ppg-2r-940-reflectance-spo2-module. Accessed 19 Feb 2025."},{"key":"1381_CR6","doi-asserted-by":"publisher","unstructured":"Advincula ARA, Masilang JMB, Villablanca JMF, Sison LG. Cardiovascular rehabilitation equipment (CaRE). TENCON 2018\u20132018 IEEE Reg 10 Conf [Internet]. Jeju, Korea (South): IEEE; 2018 [cited 2025 Feb 19]. pp. 0907\u201312. https:\/\/doi.org\/10.1109\/TENCON.2018.8650074","DOI":"10.1109\/TENCON.2018.8650074"},{"key":"1381_CR7","doi-asserted-by":"publisher","first-page":"2758","DOI":"10.1109\/JBHI.2021.3051967","volume":"25","author":"CA Gomez-Garcia","year":"2021","unstructured":"Gomez-Garcia CA, Askar-Rodriguez M, Velasco-Medina J. Platform for healthcare promotion and cardiovascular disease prevention. IEEE J Biomed Health Inform. 2021;25:2758\u201367. https:\/\/doi.org\/10.1109\/JBHI.2021.3051967.","journal-title":"IEEE J Biomed Health Inform"},{"key":"1381_CR8","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1093\/milmed\/usaa314","volume":"186","author":"N Mark","year":"2021","unstructured":"Mark N, Lyubin A, Gerasi R, Ofir D, Tsur AM, Chen J, et al. Comparison of the effects of motion and environment conditions on accuracy of handheld and finger-based pulse oximeters. Mil Med. 2021;186:465\u201372. https:\/\/doi.org\/10.1093\/milmed\/usaa314.","journal-title":"Mil Med"},{"key":"1381_CR9","doi-asserted-by":"publisher","first-page":"121","DOI":"10.2147\/MDER.S366053","volume":"15","author":"HD Nemomssa","year":"2022","unstructured":"Nemomssa HD, Raj H. Development of Low-Cost and portable pulse oximeter device with improved accuracy and accessibility. Med Devices Evid Res. 2022;15:121\u20139. https:\/\/doi.org\/10.2147\/MDER.S366053.","journal-title":"Med Devices Evid Res"},{"key":"1381_CR10","doi-asserted-by":"publisher","unstructured":"Preejith SP, Ravindran AS, Hajare R, Joseph J, Sivaprakasam M. A wrist worn SpO2 monitor with custom finger probe for motion artifact removal. 2016 38th annu int Conf IEEE eng med biol Soc EMBC [Internet]. Orlando, FL, USA: IEEE; 2016 [cited 2025 Feb 19]. pp. 5777\u201380. https:\/\/doi.org\/10.1109\/EMBC.2016.7592040","DOI":"10.1109\/EMBC.2016.7592040"},{"key":"1381_CR11","doi-asserted-by":"publisher","unstructured":"Tang MF, Chen XX, Zhao Z, He ZL, Fang Z. Wavelet-Based Real-time Monitoring of Multi-Physiological Parameters on a Portable Embedded Platform. 2018 IEEE Int Conf Inf Autom ICIA [Internet]. Wuyishan, China: IEEE; 2018 [cited 2025 Feb 19]. pp. 882\u20137. https:\/\/doi.org\/10.1109\/ICInfA.2018.8812603","DOI":"10.1109\/ICInfA.2018.8812603"},{"key":"1381_CR12","doi-asserted-by":"publisher","first-page":"327","DOI":"10.3233\/THC-229008","volume":"31","author":"A Badnjevic","year":"2023","unstructured":"Badnjevic A, Deumic A, Softic A, Pokvic LG, Badnjevic A. A novel method for conformity assessment testing of patient monitors for post-market surveillance purposes. Technol Health Care. 2023;31:327\u201337. https:\/\/doi.org\/10.3233\/THC-229008.","journal-title":"Technol Health Care"},{"key":"1381_CR13","doi-asserted-by":"publisher","unstructured":"De Palma L, Attivissimo F, Di Nisio A, Lanzolla AML, Ragolia MA, Spadavecchia M. Development of a web-based system for interfacing a portable Bluetooth vital sign monitor. 2022 IEEE Int Symp Med Meas Appl MeMeA [Internet]. Messina, Italy: IEEE; 2022 [cited 2025 Feb 19]. pp. 1\u20136. https:\/\/doi.org\/10.1109\/MeMeA54994.2022.9856526","DOI":"10.1109\/MeMeA54994.2022.9856526"},{"key":"1381_CR14","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1007\/978-3-030-73909-6_44","volume-title":"CMBEBIH 2021 [Internet]","author":"A Deumi\u0107","year":"2021","unstructured":"Deumi\u0107 A, Imamovi\u0107 E, Pokvi\u0107 LG, Badnjevi\u0107 A. Performance inspection of patient monitors according to the legal metrology framework: Bosnia and Herzegovina case study. In: Badnjevic A, Gurbeta Pokvi\u0107 L, editors. CMBEBIH 2021 [Internet]. Cham: Springer International Publishing; 2021. pp. 386\u201392. [cited 2025 Feb 19]. https:\/\/doi.org\/10.1007\/978-3-030-73909-6_44."},{"key":"1381_CR15","doi-asserted-by":"publisher","first-page":"2793","DOI":"10.3233\/THC-231996","volume":"32","author":"Q Hu","year":"2024","unstructured":"Hu Q, Li M, Jiang L, Liu M. A hybrid denoising approach for PPG signals utilizing variational mode decomposition and improved wavelet thresholding. Technol Health Care. 2024;32:2793\u2013814. https:\/\/doi.org\/10.3233\/THC-231996.","journal-title":"Technol Health Care"},{"key":"1381_CR16","doi-asserted-by":"publisher","unstructured":"Kudrna P, Soukopova M, Automatic Recognition of Numeric Values from the Monitor of Vital Signs, Iasi IEEE. 2020 [cited 2025 Feb 19]. pp. 1\u20134. https:\/\/doi.org\/10.1109\/EHB50910.2020.9279883","DOI":"10.1109\/EHB50910.2020.9279883"},{"key":"1381_CR17","doi-asserted-by":"publisher","unstructured":"Mohamed Tanveejul APS, Alex A, Preejith SP, Christopher DJ, Balamugesh, Chandy S et al. A Study on the Subject and Location Specificity in Reflectance based SpO2 Estimation using R-value based Calibration Curve. 2020 IEEE Int Symp Med Meas Appl MeMeA [Internet]. Bari, Italy: IEEE; 2020 [cited 2025 Feb 19]. pp. 1\u20136. https:\/\/doi.org\/10.1109\/MeMeA49120.2020.9137227","DOI":"10.1109\/MeMeA49120.2020.9137227"},{"key":"1381_CR18","doi-asserted-by":"publisher","unstructured":"Nguyen QH, Dang Q, Pham C, Nguyen T-D, Nguyen H, Setty A et al. Developing an Architecture for IoT Interoperability in Healthcare: A Case Study of Real-time SpO2 Signal Monitoring and Analysis. 2020 IEEE Int Conf Big Data Big Data [Internet]. Atlanta, GA, USA: IEEE; 2020 [cited 2025 Feb 19]. pp. 3394\u2013403. https:\/\/doi.org\/10.1109\/BigData50022.2020.9378200","DOI":"10.1109\/BigData50022.2020.9378200"},{"key":"1381_CR19","doi-asserted-by":"publisher","first-page":"13462","DOI":"10.1109\/JSEN.2022.3177205","volume":"22","author":"Y Wang","year":"2022","unstructured":"Wang Y, Miao F, An Q, Liu Z, Chen C, Li Y. Wearable multimodal vital sign monitoring sensor with fully integrated analog front end. IEEE Sens J. 2022;22:13462\u201371. https:\/\/doi.org\/10.1109\/JSEN.2022.3177205.","journal-title":"IEEE Sens J"},{"key":"1381_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/s20226581","volume":"20","author":"Q Zhang","year":"2020","unstructured":"Zhang Q, Arney D, Goldman JM, Isselbacher EM, Armoundas AA. Design implementation and evaluation of a mobile continuous blood oxygen saturation monitoring system. Sensors. 2020;20:6581. https:\/\/doi.org\/10.3390\/s20226581.","journal-title":"Sensors"},{"key":"1381_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.eclinm.2021.101040","volume":"38","author":"K Baker","year":"2021","unstructured":"Baker K, Petzold M, Mucunguzi A, Wharton-Smith A, Dantzer E, Habte T, et al. Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings \u2013 a prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda. eClinicalMedicine. 2021;38:101040. https:\/\/doi.org\/10.1016\/j.eclinm.2021.101040.","journal-title":"eClinicalMedicine"},{"key":"1381_CR22","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1109\/TBCAS.2022.3204632","volume":"16","author":"T Adiono","year":"2022","unstructured":"Adiono T, Ahmadi N, Saraswati C, Aditya Y, Yudhanto YP, Aziz A, et al. Respinos: a portable device for remote vital signs monitoring of COVID-19 patients. IEEE Trans Biomed Circuits Syst. 2022;16:947\u201361. https:\/\/doi.org\/10.1109\/TBCAS.2022.3204632.","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"1381_CR23","doi-asserted-by":"publisher","DOI":"10.1063\/1.4979878","volume":"88","author":"W Dai","year":"2017","unstructured":"Dai W, Lin L, Li G. New method of extracting information of arterial oxygen saturation based on \u2211|\ud835\udeab|. Rev Sci Instrum. 2017;88:043107. https:\/\/doi.org\/10.1063\/1.4979878.","journal-title":"Rev Sci Instrum"},{"key":"1381_CR24","doi-asserted-by":"publisher","unstructured":"Dias D, Ferreira N, Cunha JPS, VitalLogger. An adaptable wearable physiology and body-area ambiance data logger for mobile applications. 2017 IEEE 14th Int Conf Wearable Implant Body Sens Netw BSN [Internet]. Eindhoven: IEEE; 2017 [cited 2025 Feb 19]. pp. 71\u20134. https:\/\/doi.org\/10.1109\/BSN.2017.7936010","DOI":"10.1109\/BSN.2017.7936010"},{"key":"1381_CR25","doi-asserted-by":"publisher","unstructured":"Tang F, Li Z, Yang T, Zhang L, Zhou X, Hu S, et al. A Noise-Reduced Light-to-Frequency converter for Sub-0.1% perfusion index blood SpO$_{\\text 2}$ sensing. IEEE Trans Biomed Circuits Syst. 2020;14:931\u201341. https:\/\/doi.org\/10.1109\/TBCAS.2020.3010362.","DOI":"10.1109\/TBCAS.2020.3010362"},{"key":"1381_CR26","doi-asserted-by":"publisher","unstructured":"Mannheimer PD, Batchelder PB, Larsen M, Gehring H, Konecny E. The use of pulse oximeter functional testers in evaluating Spo2 accuracy. Anesth Analg. 2004;1871. https:\/\/doi.org\/10.1213\/01.ANE.0000137450.24266.00.","DOI":"10.1213\/01.ANE.0000137450.24266.00"},{"key":"1381_CR27","doi-asserted-by":"publisher","unstructured":"Van Oostrom JH, Melker RJ. Comparative testing of pulse oximeter probes: anesth analg. 2004;1354\u20138. https:\/\/doi.org\/10.1213\/01.ANE.0000105869.91626.3A","DOI":"10.1213\/01.ANE.0000105869.91626.3A"},{"key":"1381_CR28","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1007\/s10877-011-9283-3","volume":"25","author":"S Dugani","year":"2011","unstructured":"Dugani S, Hodzovic I, Sindhakar S, Nadra A, Dunstan C, Wilkes AR, et al. Evaluation of a pulse oximeter sensor tester. J Clin Monit Comput. 2011;25:163\u201370. https:\/\/doi.org\/10.1007\/s10877-011-9283-3.","journal-title":"J Clin Monit Comput"},{"key":"1381_CR29","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1111\/anae.12090","volume":"68","author":"QJW Milner","year":"2013","unstructured":"Milner QJW, Mathews GR, Powell RJ. Accuracy of the Lightman\u00ae pulse oximeter tester. Anaesthesia. 2013;68:111\u20132. https:\/\/doi.org\/10.1111\/anae.12090.","journal-title":"Anaesthesia"},{"key":"1381_CR30","doi-asserted-by":"publisher","DOI":"10.3390\/s23146628","volume":"23","author":"J Lambert Cause","year":"2023","unstructured":"Lambert Cause J, Sol\u00e9 Morillo \u00c1, Da Silva B, Garc\u00eda-Naranjo JC, Stiens J. Novel multi-parametric sensor system for comprehensive multi-wavelength photoplethysmography characterization. Sensors. 2023;23:6628. https:\/\/doi.org\/10.3390\/s23146628.","journal-title":"Sensors"},{"key":"1381_CR31","unstructured":"Contec. SpO2 Simulator MS100 Pulse Rate Blood Oxygen Simulator Pulse Oximeter reaction time [Internet]. CONTEC. [cited 2025 Feb 19]. https:\/\/contechealth.com\/products\/ms100-spo2-simulator. Accessed 19 Feb 2025."},{"key":"1381_CR32","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1109\/JSEN.2019.2942099","volume":"20","author":"DLT Wong","year":"2020","unstructured":"Wong DLT, Yu J, Li Y, Deepu CJ, Ngo DH, Zhou C, et al. An integrated wearable wireless vital signs biosensor for continuous inpatient monitoring. IEEE Sens J. 2020;20:448\u201362. https:\/\/doi.org\/10.1109\/JSEN.2019.2942099.","journal-title":"IEEE Sens J"},{"key":"1381_CR33","doi-asserted-by":"publisher","DOI":"10.3390\/app10227977","volume":"10","author":"D Kulin","year":"2020","unstructured":"Kulin D, Antali F, Kulin S, Wafa D, Lucz KI, Veres DS, et al. Preclinical, multi-aspect assessment of the reliability of a photoplethysmography-based telemonitoring system to track cardiovascular status. Appl Sci. 2020;10:7977. https:\/\/doi.org\/10.3390\/app10227977.","journal-title":"Appl Sci"},{"key":"1381_CR34","doi-asserted-by":"publisher","DOI":"10.1136\/bmjgh-2021-006069","volume":"6","author":"HR Graham","year":"2021","unstructured":"Graham HR, Olojede OE, Bakare AA, Iuliano A, Olatunde O, Isah A, et al. Measuring oxygen access: lessons from health facility assessments in Lagos, Nigeria. BMJ Glob Health. 2021;6:e006069. https:\/\/doi.org\/10.1136\/bmjgh-2021-006069.","journal-title":"BMJ Glob Health"},{"key":"1381_CR35","unstructured":"ISO 80601-2-. 61:2017(en), Medical electrical equipment \u2014 Part 2\u201361: Particular requirements for basic safety and essential performance of pulse oximeter equipment [Internet]. [cited 2025 Feb 19]. https:\/\/www.iso.org\/obp\/ui\/en\/#iso:std:iso:80601:-2-61:ed-2:v2:en. Accessed 19 Feb 2025."},{"key":"1381_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ebiom.2024.105051","volume":"102","author":"G Leeb","year":"2024","unstructured":"Leeb G, Auchus I, Law T, Bickler P, Feiner J, Hashi S, et al. The performance of 11 fingertip pulse oximeters during hypoxemia in healthy human participants with varied, quantified skin pigment. eBioMedicine. 2024;102:105051. https:\/\/doi.org\/10.1016\/j.ebiom.2024.105051.","journal-title":"eBioMedicine"},{"key":"1381_CR37","unstructured":"Food US. & Drug Administration. 510(k) Premarket Notification [Internet]. 510k Premarket Notif. [cited 2025 Feb 19]. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm. Accessed 19 Feb 2025."},{"key":"1381_CR38","unstructured":"openoximetry.org. Open Oximetry [Internet]. OpenOximetry. [cited 2025 Feb 19]. https:\/\/openoximetry.org\/oximeters\/. Accessed 19 Feb 2025."},{"key":"1381_CR39","doi-asserted-by":"publisher","unstructured":"Lipnick MS, Chen D, Law T, Moore K, Lester JC, Monk EP et al. Comparison of methods for characterizing skin pigment diversity in research cohorts [Internet]. Dermatology; 2025 [cited 2025 Oct 10]. https:\/\/doi.org\/10.1101\/2025.02.21.25322707","DOI":"10.1101\/2025.02.21.25322707"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01381-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-025-01381-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-025-01381-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T03:49:37Z","timestamp":1775447377000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-025-01381-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,14]]},"references-count":39,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["1381"],"URL":"https:\/\/doi.org\/10.1007\/s10877-025-01381-0","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,14]]},"assertion":[{"value":"15 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Jake Dove is an employee of Medtronic and his contributions to this study were limited to data analysis and interpretation of the data. He was not involved in the collection of data or any other aspect of the study to ensure objectivity and minimize potential conflicts of interest. Michael Bernstein has previously been employed by Nellcor (now Covidien), where he managed the development of pulse oximeters. He also served as a consultant for multiple medical device companies, including industry leaders, through Physio Monitor, specializing in pulse oximetry design. He has also contributed to the development of clinical parameter simulators, including EKG, SpO\u2082, NIBP, IBP, and EEG, for various companies, including pulse oximetry systems for Fluke and Siemens Electromedical Group (now Draeger Medical). Michael Bernstein is also a partner for an in vivo human testing laboratory, the Hypoxia Lab at Shenzhen University, which focuses on SpO\u2082 and cuffless NIBP research. Dr. John Feiner performs pulse oximetry accuracy studies for various companies. He does not receive direct payment from these companies. He did not receive direct payment for this work. All other authors declare they have no financial interests or disclosures.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The controlled desaturation studies were performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Institutional Review Board of the University of California, San Francisco.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Written informed consent was obtained from each adult volunteer prior to their participation in the controlled desaturation studies.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors affirm that the human research participants provided informed consent for the publication of the images in Figure(s) 2, 4, and 5.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}