{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T17:05:18Z","timestamp":1790960718871,"version":"4.1.0"},"reference-count":77,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T00:00:00Z","timestamp":1769990400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T00:00:00Z","timestamp":1769990400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Shock is a life-threatening condition marked by inadequate tissue perfusion and oxygen supply, leading to organ failure if not rapidly addressed. Clinical management of shock involves detecting and correcting altered macro hemodynamic parameters. However, these parameters may not accurately reflect microcirculatory alterations or abnormalities in oxygenation. A resuscitation strategy focused on peripheral perfusion, which can be non-invasively monitored, may allow for earlier shock detection and treatment, potentially reducing mortality. This literature review aims to study the available technologies found in literature and in patents to non-invasively monitor peripheral perfusion. PRISMA method was employed to systematically select or exclude articles and patents, resulting in 44 studies and 21 patents included in the review. The found technologies were classified based on the sensing principle in light (reflected, transmitted, or scattered), Doppler effect, temperature, and skin mottling. Combining the monitorization of microcirculatory with macrocirculatory parameters has the potential to have an accurate prognosis value for shock and other diseases. However, the various technologies that have been developed to monitor peripheral perfusion require further research and testing in diverse conditions.<\/jats:p>","DOI":"10.1007\/s10877-026-01412-4","type":"journal-article","created":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T04:27:19Z","timestamp":1770006439000},"page":"673-686","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Peripheral perfusion noninvasive monitoring technologies - a literature and patent review"],"prefix":"10.1007","volume":"40","author":[{"given":"Irene","family":"Orellana Plaza","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenny","family":"Dankelman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Bakker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,2,2]]},"reference":[{"key":"1412_CR1","doi-asserted-by":"publisher","first-page":"1971","DOI":"10.1007\/s00134-025-08137-z","volume":"51","author":"X Monnet","year":"2025","unstructured":"Monnet X, Messina A, Greco M, et al. ESICM guidelines on circulatory shock and hemodynamic monitoring 2025. Intensive Care Med. 2025;51:1971\u20132012. https:\/\/doi.org\/10.1007\/s00134-025-08137-z.","journal-title":"Intensive Care Med"},{"key":"1412_CR2","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/S0140-6736(19)32989-7","volume":"39510219","author":"KE Rudd","year":"2020","unstructured":"Rudd KE, Jonhson SC, Agesa KM, et al. Global, regional, and National sepsis incidence and mortality, 1990\u20132017: analysis for the global burden of disease study. Lancet. 2020;39510219:200\u201311. https:\/\/doi.org\/10.1016\/S0140-6736(19)32989-7.","journal-title":"Lancet"},{"key":"1412_CR3","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","volume":"40","author":"M Cecconi","year":"2014","unstructured":"Cecconi M, de Backer D, Antonelli M, et al. Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine. Intensive Care Med. 2014;40:1795\u2013815. https:\/\/doi.org\/10.1007\/s00134-014-3525-z.","journal-title":"Intensive Care Med"},{"key":"1412_CR4","doi-asserted-by":"publisher","unstructured":"Putowski Z, Goldyn M, Pluta M, et al. Correlation between mean arterial pressure and capillary refill time in patients with septic shock: A systematic review and Meta-analysis. J Intensive Care Med. 2023;39. https:\/\/doi.org\/10.1177\/08850666231168038.","DOI":"10.1177\/08850666231168038"},{"issue":"5","key":"1412_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/cc12727","volume":"17","author":"MW Dunser","year":"2013","unstructured":"Dunser MW, Takala J, Brunauer A, Bakker J. Re-thinking resuscitation: leaving blood pressure cosmetics behind and moving forward to permissive hypotension and a tissue perfusion-based approach. Crit Care. 2013;17(5):326. https:\/\/doi.org\/10.1186\/cc12727.","journal-title":"Crit Care"},{"issue":"6","key":"1412_CR6","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1097\/00003246-200206000-00006","volume":"30","author":"AP Lima","year":"2002","unstructured":"Lima AP, Beelen P, Bakker J. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Crit Care Med. 2002;30(6):1210\u20133. https:\/\/doi.org\/10.1097\/00003246-200206000-00006.","journal-title":"Crit Care Med"},{"issue":"3","key":"1412_CR7","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1097\/CCM.0b013e31819869db","volume":"37","author":"A Lima","year":"2019","unstructured":"Lima A, Jansen T, Van Bommel J, Bakker J. The prognostic value of the subjective assessment of peripheral perfusion in critically ill patients. Crit Care Med. 2019;37(3):934\u20138. https:\/\/doi.org\/10.1097\/CCM.0b013e31819869db.","journal-title":"Crit Care Med"},{"issue":"3","key":"1412_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/cc13905","volume":"18","author":"ME van Genderen","year":"2014","unstructured":"van Genderen ME, Paauwe J, de Jonge J, van der Valk RJ, Lima A, Bakker J, et al. Clinical assessment of peripheral perfusion to predict postoperative complications after major abdominal surgery early: a prospective observational study in adults. Crit Care. 2014;18(3):R114. https:\/\/doi.org\/10.1186\/cc13905.","journal-title":"Crit Care"},{"issue":"4","key":"1412_CR9","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1164\/rccm.201408-1575LE","volume":"191","author":"ME van Genderen","year":"2015","unstructured":"van Genderen ME, Engels N, van der Valk RJ, et al. Early peripheral perfusion-guided fluid therapy in patients with septic shock. Am J Respir Crit Care Med. 2015;191(4):477\u201380. https:\/\/doi.org\/10.1164\/rccm.201408-1575LE.","journal-title":"Am J Respir Crit Care Med"},{"issue":"7","key":"1412_CR10","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1001\/jama.2019.0071","volume":"321","author":"G Hernandez","year":"2019","unstructured":"Hernandez G, Ospina-Tascon GA, Damiani LP, et al. Effect of a resuscitation strategy targeting peripheral perfusion status vs serum lactate levels on 28-day mortality among patients with septic shock: the ANDROMEDA-SHOCK randomized clinical trial. JAMA. 2019;321(7):654\u201364. https:\/\/doi.org\/10.1001\/jama.2019.0071.","journal-title":"JAMA"},{"issue":"3","key":"1412_CR11","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1097\/MCC.0000000000000194","volume":"21","author":"A Lima","year":"2015","unstructured":"Lima A, Bakker J. Clinical assessment of peripheral circulation. Curr Opin Crit Care. 2015;21(3):226\u201331. https:\/\/doi.org\/10.1097\/MCC.0000000000000194.","journal-title":"Curr Opin Crit Care"},{"key":"1412_CR12","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","volume":"372","author":"JP Matthew","year":"2021","unstructured":"Matthew JP, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. https:\/\/doi.org\/10.1136\/bmj.n71.","journal-title":"BMJ"},{"key":"1412_CR13","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2022.1035567","volume":"10","author":"S Lamprea","year":"2022","unstructured":"Lamprea S, Fern\u00e1ndez-Sarmiento J, Barrera S, Mora A, Fern\u00e1ndez-Sarta JP, Acevedo L. Capillary refill time in sepsis: a useful and easily accessible tool for evaluating perfusion in children. Front Pediatr. 2022;10:1035567. https:\/\/doi.org\/10.3389\/fped.2022.1035567.","journal-title":"Front Pediatr"},{"issue":"9","key":"1412_CR14","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0138155","volume":"10","author":"S Fleming","year":"2015","unstructured":"Fleming S, Gill P, Jones C, et al. The diagnostic value of capillary refill time for detecting serious illness in children: a systematic review and meta-analysis. PLoS One. 2015;10(9):e0138155. https:\/\/doi.org\/10.1371\/journal.pone.0138155.","journal-title":"PLoS One"},{"issue":"12","key":"1412_CR15","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1136\/emermed-2013-202925","volume":"31","author":"M Mrgan","year":"2014","unstructured":"Mrgan M, Rytter D, Brabrand M. Capillary refill time is a predictor of short-term mortality for adult patients admitted to a medical department: an observational cohort study. Emerg Med J. 2014;31(12):954\u20138. https:\/\/doi.org\/10.1136\/emermed-2013-202925.","journal-title":"Emerg Med J"},{"key":"1412_CR16","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2025.20402","author":"ANDROMEDA-SHOCK-2 Investigators for the ANDROMEDA Research Network, Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), and Latin American Intensive Care Network (LIVEN)","year":"2025","unstructured":"ANDROMEDA-SHOCK-2 Investigators for the ANDROMEDA Research Network, Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), and Latin American Intensive Care Network (LIVEN). Personalized hemodynamic resuscitation targeting capillary refill time in early septic shock: the ANDROMEDA-SHOCK-2 randomized clinical trial. JAMA. 2025. https:\/\/doi.org\/10.1001\/jama.2025.20402.","journal-title":"JAMA"},{"issue":"1","key":"1412_CR17","doi-asserted-by":"publisher","DOI":"10.1186\/s12873-022-00681-x","volume":"22","author":"M Jacquet-Lagr\u00e8ze","year":"2022","unstructured":"Jacquet-Lagr\u00e8ze M, Wiart C, Schweizer R, et al. Capillary refill time for the management of acute circulatory failure: a survey among pediatric and adult intensivists. BMC Emerg Med. 2022;22(1):131. https:\/\/doi.org\/10.1186\/s12873-022-00681-x.","journal-title":"BMC Emerg Med"},{"issue":"1","key":"1412_CR18","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/MEJ.0b013e32833b4fba","volume":"18","author":"M Brabrand","year":"2011","unstructured":"Brabrand M, Hosbond S, Fulkestad L. Capillary refill time: a study of interobserver reliability among nurses and nurse assistants. Eur J Emerg Med. 2011;18(1):46\u20139. https:\/\/doi.org\/10.1097\/MEJ.0b013e32833b4fba.","journal-title":"Eur J Emerg Med"},{"issue":"1","key":"1412_CR19","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1213\/ANE.0b013e31821569f9","volume":"113","author":"A Pickard","year":"2011","unstructured":"Pickard A, Karlen W, Ansermino JM. Capillary refill time: is it still a useful clinical sign? Anesth Analg. 2011;113(1):120\u20133. https:\/\/doi.org\/10.1213\/ANE.0b013e31821569f9.","journal-title":"Anesth Analg"},{"key":"1412_CR20","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1016\/j.ajem.2022.02.056","volume":"58","author":"J Gillespie","year":"2022","unstructured":"Gillespie J, Sheridan DC, Samatham R, Hansen M. Accuracy of point-of-care capillary refill technology in individuals of varying race and ethnicity. Am J Emerg Med. 2022;58:309\u201310. https:\/\/doi.org\/10.1016\/j.ajem.2022.02.056.","journal-title":"Am J Emerg Med"},{"issue":"1","key":"1412_CR21","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1088\/0967-3334\/37\/1\/83","volume":"37","author":"LL Blaxter","year":"2015","unstructured":"Blaxter LL, Morris DE, Crowe JA, et al. An automated quasi-continuous capillary refill timing device. Physiol Meas. 2015;37(1):83. https:\/\/doi.org\/10.1088\/0967-3334\/37\/1\/83.","journal-title":"Physiol Meas"},{"key":"1412_CR22","doi-asserted-by":"publisher","unstructured":"Liu C, Correira R, Ballaji H, Korposh S, Hayes-Gil, Morgan S. (2020) Optical fibre sensor for simultaneous measurement of capillary refill time and contact pressure 20(5):1388. https:\/\/doi.org\/10.3390\/s20051388","DOI":"10.3390\/s20051388"},{"key":"1412_CR23","doi-asserted-by":"publisher","unstructured":"Kviesis-Kipge E, Curkste E, Spigulis J, Gardovska D. (2009) Optical studies of the capillary refill kinetics in fingertips. D\u00f6ssel O., Schlegel, W.C, editors World Congress on Medical Physics and Biomedical Engineering, September 7\u201312, 2009, Munich, Germany. IFMBE Proceedings. Springer 25(7):377-9. https:\/\/doi.org\/10.1007\/978-3-642-03885-3_105","DOI":"10.1007\/978-3-642-03885-3_105"},{"key":"1412_CR24","doi-asserted-by":"publisher","unstructured":"Kieser E, Dellimore K, Scheffer C, Visser C, Smith J. Development of diagnostic sensors for infant dehydration assessment using optical methods. 2015 37th Annual Int Conf IEEE Eng Med Biology Soc (EMBC). 2015;Milan, Italy 5537\u201340. https:\/\/doi.org\/10.1109\/EMBC.2015.7319646.","DOI":"10.1109\/EMBC.2015.7319646"},{"issue":"3","key":"1412_CR25","doi-asserted-by":"publisher","DOI":"10.1299\/jbse.23-00002","volume":"18","author":"S Sugita","year":"2023","unstructured":"Sugita S, Mizuno T, Ujihara Y, Nakamura M. Improvement in the precision of capillary refill time measurements for diagnosing hypovolemic status\u201d. J Biomech Sci Eng. 2023;18(3):23\u2009\u2212\u200900003. https:\/\/doi.org\/10.1299\/jbse.23-00002.","journal-title":"J Biomech Sci Eng"},{"key":"1412_CR26","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1007\/s10877-021-00757-2","volume":"36","author":"M Ruste","year":"2022","unstructured":"Ruste M, Cazenave L, Tardif M, Saint-Jean C, Fellahi J-L, Lagr\u00e8ze MJ. Measurement of capillary refill time with a handheld prototype device: a comparative validation study in healthy volunteers. J Clin Monit Comput. 2022;36:1271\u20138. https:\/\/doi.org\/10.1007\/s10877-021-00757-2.","journal-title":"J Clin Monit Comput"},{"key":"1412_CR27","doi-asserted-by":"publisher","unstructured":"Klibus M, Eunapu V, Marcinkevics Z et al. (2023) Assessment of Peripheral Perfusion Using Remote Photoplethysmography and Automated Capillary Refill Time Techniques in Severe COVID-19 Patients. Dekhtyar, Y., Saknite, I, editors 19th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics. NBC 2023. IFMBE Proceedings, vol 89. Sprinter https:\/\/doi.org\/10.1007\/978-3-031-37132-5_44","DOI":"10.1007\/978-3-031-37132-5_44"},{"key":"1412_CR28","doi-asserted-by":"crossref","unstructured":"Kerr E, Coleman S, McGinnity M, Sphepherd A. (2018) Measurement of capillary refill time (crt) in healthy subjects using a robotic hand. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition Workshops 1291-8.","DOI":"10.1109\/CVPRW.2018.00176"},{"key":"1412_CR29","doi-asserted-by":"publisher","unstructured":"De Souza Bachour RP, Lopes Dias E, Cardoso GC. Skin-color-independent robust assessment of capillary refill time. J Biophotonics. 2023;16(11). https:\/\/doi.org\/10.1002\/jbio.202300063.","DOI":"10.1002\/jbio.202300063"},{"key":"1412_CR30","doi-asserted-by":"publisher","unstructured":"Strutt J, Narayanswamy G, Park C, et al. CAPAPP: Smartphone-based capillary refill index assessment in healthy children. Front Biomedical Devices Am Soc Mech Eng. 2023;86731. https:\/\/doi.org\/10.1115\/DMD2023-6655. V001T09A009.","DOI":"10.1115\/DMD2023-6655"},{"key":"1412_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-019-00454-1","volume":"35","author":"K Shinozaki","year":"2021","unstructured":"Shinozaki K, Saeki K, Jacobson LS, et al. Evaluation of accuracy of capillary refill index with pneumatic fingertip compression. J Clin Monit Comput. 2021;35:135.45. https:\/\/doi.org\/10.1007\/s10877-019-00454-1.","journal-title":"J Clin Monit Comput"},{"key":"1412_CR32","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2020.614326","volume":"7","author":"JM Falotico","year":"2020","unstructured":"Falotico JM, Shinozaki K, Saeki K, Becker LB. Advances in the approaches using peripheral perfusion for monitoring hemodynamic status. Front Med. 2020;7:614326. https:\/\/doi.org\/10.3389\/fmed.2020.614326.","journal-title":"Front Med"},{"key":"1412_CR33","unstructured":"Sheridan D, Hansen ML, Kibler A, Baker SD, Sunderland RA, Weitzel RH. (2023) Measuring capillary refill time (U.S. Patent 11806114B2)."},{"key":"1412_CR34","unstructured":"Bezemer R, Flower AA, Van Z C C A, M. (2020) Approach for measuring capillary refill time (Japan Patent 2020110616A)."},{"key":"1412_CR35","unstructured":"Hollander EJ. (2023) Smartphone software-based measurement of cyanosis and capillary refill time (U.S. Patent 11712165B2)."},{"key":"1412_CR36","unstructured":"Nakaguchi T, Nakada T, Oda S, Haneishi H. (2019) CRT measurement device (World Intellectual Property Organization Patent 2019031527A1)."},{"key":"1412_CR37","unstructured":"Morgan S, Hayes-Gil B, Korposh S, Correia R. (2021) Monitoring physiological parameters (U.S. Patent 2021251571A1)."},{"key":"1412_CR38","unstructured":"Korposh S, Morgan S, Hayes-Gill B. (2015) Capillary refill measurement (World Intellectual Property Organization Patent 2015155526A1)."},{"key":"1412_CR39","unstructured":"Sharkey D, Blaxter L, Crowe J, Hayes-Gill B, Morris D. (2019) Measurement of capillary refill time. (World Intellect Property Organ Patent 2017009669A1)."},{"key":"1412_CR40","unstructured":"Cui L, He X, Gong X, Zhuang Y, Wang L, Zhu L. (2022) Finger tip capillary refilling time automatic evaluation device (China Patent 114052698A)."},{"key":"1412_CR41","unstructured":"Messerges J, Hutchinson G, Gen E. (2007) Method and apparatus for measuring capillary refill time and carrying out pulse oximetry with a single device (U.S. Patent 2007282182A1)."},{"key":"1412_CR42","unstructured":"Gao F, Luo Z, Zhang J, Luo J, Tu G. (2022) Intelligent sensing device for detecting capillary refilling time (China Patent 217987568U)."},{"key":"1412_CR43","unstructured":"Tan K, Shi J, Wang Z, Li J et al. (2020) Blood capillary refilling time measuring instrument and method (China Patent 110731772A)."},{"key":"1412_CR44","unstructured":"Fan H, Liu Y, Chen X, Wang Y, Liu Z, Meng X. (2023) Hemorrhagic shock microcirculation monitoring equipment and system (China Patent 116327159A)."},{"key":"1412_CR45","unstructured":"Sun S, Hao X, Zhang C, Du S, Wu S. (2021) Full-automatic capillary refilling time measuring instrument and measuring method based on PID pressure control (China Patent 113693570A)."},{"key":"1412_CR46","unstructured":"Wang Z, Zhang Z, Xie Z, Liu Y. (2019) Capillary refilling time measuring mechanism and measuring method (China Patent 109171658A)."},{"key":"1412_CR47","unstructured":"Wang Z, Zhanf Z, Miao Z. (2020) Capillary refilling time measuring instrument (China Patent 210446999U)."},{"key":"1412_CR48","unstructured":"Nakaguchi T, Shinozaki M, Nakata T, Oda N, Miyazaki Y. (2021) Measuring Apparatus (Japan Patent 2021003376A)."},{"key":"1412_CR49","unstructured":"Li W, Chen H, Xian S et al. (2021) Capillary filling time detection device (China Patent 214965478U)."},{"key":"1412_CR50","unstructured":"Kim T, Jung H, Kim Y. (2014) Device for measuring capillary recharge time and controlling method thereof (Korea Patent 101459652B1)."},{"key":"1412_CR51","unstructured":"Bezzerides V, Neuman M. (2013) Capillary refill time diagnostic apparatus and methods (U.S. Patent 2013018241A1)."},{"key":"1412_CR52","unstructured":"Hirabara H, Harada Y. (2023) Pulse oximeter, pulse oximetry system, processing device, and pulse oximetry method (U.S. Patent 2023048928A1)."},{"key":"1412_CR53","unstructured":"Kobayashi N. (2012) Biological signal measuring apparatus and biological signal measuring method (Japan Patent 2012115640A)."},{"key":"1412_CR54","unstructured":"Vogel U, Richter B, Richter T. (2022) Method and device for the objective determination of capillary refill behavior on a human body surface (U.K. Patent 2596913A)."},{"key":"1412_CR55","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1117\/12.2534989","volume":"11144","author":"MG Sowa","year":"2019","unstructured":"Sowa MG. Snapshotnir: a handheld multispectral imaging system for tissue viability assessment. Photonics Educ Meas Sci. 2019;11144:55\u201360. https:\/\/doi.org\/10.1117\/12.2534989.","journal-title":"Photonics Educ Meas Sci"},{"issue":"9","key":"1412_CR56","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1007\/s10439-023-03229-7","volume":"51","author":"K Leiva","year":"2023","unstructured":"Leiva K, Leizaola D, Gonzalez I, et al. Spatial\u2013temporal oxygenation mapping using a near-infrared optical scanner: towards peripheral vascular imaging. Ann Biomed Eng. 2023;51(9):2035\u201347. https:\/\/doi.org\/10.1007\/s10439-023-03229-7.","journal-title":"Ann Biomed Eng"},{"key":"1412_CR57","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.651909","volume":"8","author":"MM Elshal","year":"2021","unstructured":"Elshal MM, Hasanin AM, Mostafa M, Gamal RM. Plethysmographic peripheral perfusion index: could it be a new vital sign? Front Med. 2021;8:651909. https:\/\/doi.org\/10.3389\/fmed.2021.651909.","journal-title":"Front Med"},{"issue":"6","key":"1412_CR58","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1097\/00003246-200206000-00006","volume":"30","author":"A Pinto Lima","year":"2002","unstructured":"Pinto Lima A, Beelen P, Bakker J. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Crit Care Med. 2002;30(6):1210\u20133. https:\/\/doi.org\/10.1097\/00003246-200206000-00006.","journal-title":"Crit Care Med"},{"issue":"1","key":"1412_CR59","doi-asserted-by":"publisher","first-page":"33","DOI":"10.4103\/sja.sja_634_22","volume":"17","author":"Y Iizuka","year":"2023","unstructured":"Iizuka Y, Yoshinaga K, Nakatomi T, Takahashi K, Yoshida K, Sanui M. A low peripheral perfusion index can accurately detect prolonged capillary refill time during general anesthesia: a prospective observational study. Saudi J Anaesth. 2023;17(1):33\u20138. https:\/\/doi.org\/10.4103\/sja.sja_634_22.","journal-title":"Saudi J Anaesth"},{"issue":"6","key":"1412_CR60","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1097\/ANC.0b013e3182337ebb","volume":"11","author":"T Marrin","year":"2011","unstructured":"Marrin T, Moore J. Understanding near-infrared spectroscopy. Adv Neonatal Care. 2011;11(6):382\u20138. https:\/\/doi.org\/10.1097\/ANC.0b013e3182337ebb.","journal-title":"Adv Neonatal Care"},{"issue":"4","key":"1412_CR61","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1139\/h04-031","volume":"29","author":"M Ferrari","year":"2004","unstructured":"Ferrari M, Mottola L, Quaresima V. Principles, techniques, and limitations of near infrared spectroscopy. Can J Appl Physiol. 2004;29(4):463\u201387. https:\/\/doi.org\/10.1139\/h04-031.","journal-title":"Can J Appl Physiol"},{"issue":"6","key":"1412_CR62","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1007\/s10877-020-00611-x","volume":"35","author":"AA Mendelson","year":"2021","unstructured":"Mendelson AA, Rajaram A, Bainbridge D, et al. Dynamic tracking of microvascular hemoglobin content for continuous perfusion monitoring in the intensive care unit: pilot feasibility study. J Clin Monit Comput. 2021;35(6):1453\u201365. https:\/\/doi.org\/10.1007\/s10877-020-00611-x.","journal-title":"J Clin Monit Comput"},{"issue":"5","key":"1412_CR63","doi-asserted-by":"publisher","first-page":"2545","DOI":"10.1109\/JBHI.2023.3248306","volume":"27","author":"K-D Lin","year":"2023","unstructured":"Lin K-D, Lin B-S, Sung H-Y, Lin B-S. Novel smart assistance system for arteriosclerosis evaluation. IEEE J Biomed Health Inf. 2023;27(5):2545\u201352. https:\/\/doi.org\/10.1109\/JBHI.2023.3248306.","journal-title":"IEEE J Biomed Health Inf"},{"issue":"8","key":"1412_CR64","doi-asserted-by":"publisher","first-page":"10167","DOI":"10.1109\/JSEN.2021.3058717","volume":"21","author":"K-D Lin","year":"2021","unstructured":"Lin K-D, Lin B-S, Lin G-A, Lin B-S. Design of smart peripheral blood perfusion monitoring system for diabetics. IEEE Sens J. 2021;21(8):10167\u201373. https:\/\/doi.org\/10.1109\/JSEN.2021.3058717.","journal-title":"IEEE Sens J"},{"key":"1412_CR65","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.mvr.2016.12.004","volume":"111","author":"MZ Ansari","year":"2017","unstructured":"Ansari MZ, Kang E-J, Manole MD, Dreier JP, Humeau-Heurtier A. Monitoring microvascular perfusion variations with laser speckle contrast imaging using a view-based temporal template method. Microvasc Res. 2017;111:49\u201359. https:\/\/doi.org\/10.1016\/j.mvr.2016.12.004.","journal-title":"Microvasc Res"},{"issue":"6","key":"1412_CR66","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1136\/annrheumdis-2013-203514","volume":"73","author":"B Ruaro","year":"2014","unstructured":"Ruaro B, Sulli A, Alessandri E, Pizzorni C, Ferrari G, Cutolo M. Laser speckle contrast analysis: a new method to evaluate peripheral blood perfusion in systemic sclerosis patients. Ann Rheum Dis. 2014;73(6):1181\u20135. https:\/\/doi.org\/10.1136\/annrheumdis-2013-203514.","journal-title":"Ann Rheum Dis"},{"issue":"10","key":"1412_CR67","doi-asserted-by":"publisher","first-page":"5338","DOI":"10.1364\/BOE.494720","volume":"14","author":"F Bonetta-Misteli","year":"2023","unstructured":"Bonetta-Misteli F, Collins T, Pavek T, et al. Development and evaluation of a wearable peripheral vascular compensation sensor in a swine model of hemorrhage. Biomed Opt Express. 2023;14(10):5338\u201357. https:\/\/doi.org\/10.1364\/BOE.494720.","journal-title":"Biomed Opt Express"},{"key":"1412_CR68","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1007\/s10103-007-0524-0","volume":"24","author":"V Rajan","year":"2009","unstructured":"Rajan V, Varghese B, van Leeuwen TG, Steenbergen W. Review of methodological developments in laser Doppler flowmetry. Lasers Med Sci. 2009;24:269\u201383. https:\/\/doi.org\/10.1007\/s10103-007-0524-0.","journal-title":"Lasers Med Sci"},{"issue":"4","key":"1412_CR69","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1097\/CCM.0000000000004177","volume":"48","author":"W Mongkolpun","year":"2020","unstructured":"Mongkolpun W, Orbegozo D, Cordeiro C, Franco C, Vicent JL, Creteur J. Alterations in skin blood flow at the fingertip are related to mortality in patients with circulatory shock. Crit Care Med. 2020;48(4):443\u201350. https:\/\/doi.org\/10.1097\/CCM.0000000000004177.","journal-title":"Crit Care Med"},{"issue":"6","key":"1412_CR70","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.3899\/jrheum.091356","volume":"37","author":"M Cutolo","year":"2010","unstructured":"Cutolo M, Ferrone C, Pizzorni C, Soldano S, Seriolo B, Sulli A. Peripheral blood perfusion correlates with microvascular abnormalities in systemic sclerosis: a laser-doppler and nailfold videocapillaroscopy study. J Rheumatol. 2010;37(6):1174\u201380. https:\/\/doi.org\/10.3899\/jrheum.091356.","journal-title":"J Rheumatol"},{"issue":"6","key":"1412_CR71","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering10060729","volume":"10","author":"S Kazune","year":"2023","unstructured":"Kazune S, Vasiljevs E, Caica-Rinca A, Marcinkevics Z, Grabovskis A. Infrared thermography imaging for assessment of peripheral perfusion in patients with septic shock. Bioengineering. 2023;10(6):729. https:\/\/doi.org\/10.3390\/bioengineering10060729.","journal-title":"Bioengineering"},{"key":"1412_CR72","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1016\/j.avsg.2017.07.028","volume":"47","author":"GA Wallace","year":"2018","unstructured":"Wallace GA, Singh N, Quiroga E, Tran NT. The use of smart phone thermal imaging for assessment of peripheral perfusion in vascular patients. Ann Vasc Surg. 2018;47:157\u201361. https:\/\/doi.org\/10.1016\/j.avsg.2017.07.028.","journal-title":"Ann Vasc Surg"},{"issue":"1","key":"1412_CR73","doi-asserted-by":"publisher","DOI":"10.31083\/j.rcm2401007","volume":"24","author":"J Luo","year":"2023","unstructured":"Luo J, Wang H, Tong S, et al. Interpreting infrared thermography with deep learning to assess the mortality risk of critically ill patients at risk of hypoperfusion. Rev Cardiovasc Med. 2023;24(1):7. https:\/\/doi.org\/10.31083\/j.rcm2401007.","journal-title":"Rev Cardiovasc Med"},{"issue":"12","key":"1412_CR74","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.earlhumdev.2015.09.007","volume":"91","author":"M Ussat","year":"2015","unstructured":"Ussat M, Vogtmann C, Gebauer C, Pulzer F, Thome U, Kn\u00fcpfer M. The role of elevated central-peripheral temperature difference in early detection of late-onset sepsis in preterm infants. Early Hum Dev. 2015;91(12):677\u201381. https:\/\/doi.org\/10.1016\/j.earlhumdev.2015.09.007.","journal-title":"Early Hum Dev"},{"key":"1412_CR75","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1117\/12.2253597","volume":"10057","author":"I Saknite","year":"2017","unstructured":"Saknite I, Grabovskis A, Kazune S, et al. Novel hybrid technology for early diagnostics of sepsis. Multimodal Biomedical Imaging XII. 2017;10057:76\u201385. https:\/\/doi.org\/10.1117\/12.2253597.","journal-title":"Multimodal Biomedical Imaging XII"},{"key":"1412_CR76","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40560-017-0220-5","volume":"5","author":"A Hasanin","year":"2017","unstructured":"Hasanin A, Mukhtar A, Nassar H. Perfusion indices revisited. J Intensive Care. 2017;5:1\u20138. https:\/\/doi.org\/10.1186\/s40560-017-0220-5.","journal-title":"J Intensive Care"},{"key":"1412_CR77","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.resp.2015.05.011","volume":"216","author":"Z Ovadia-Blechman","year":"2015","unstructured":"Ovadia-Blechman Z, Meilin A, Rabin N, Eldar M, Castel D. Noninvasive monitoring of peripheral microcirculatory hemodynamics under varying degrees of hypoxia. Respir Physiol Neurobiol. 2015;216:23\u20137. https:\/\/doi.org\/10.1016\/j.resp.2015.05.011.","journal-title":"Respir Physiol Neurobiol"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01412-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-026-01412-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01412-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T09:58:12Z","timestamp":1779357492000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-026-01412-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,2]]},"references-count":77,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["1412"],"URL":"https:\/\/doi.org\/10.1007\/s10877-026-01412-4","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,2]]},"assertion":[{"value":"14 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}