{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T14:38:17Z","timestamp":1792075097283,"version":"4.4.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T00:00:00Z","timestamp":1774828800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-026-01430-2","type":"journal-article","created":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T05:00:00Z","timestamp":1774846800000},"page":"857-865","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Agreement between intra-bladder and insufflation pressure readings during laparoscopic surgery"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6751-1858","authenticated-orcid":false,"given":"Salar","family":"Tayebi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Beer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip","family":"Jenkins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Jaggi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Hussein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"McKinney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dipak","family":"Delvadia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc-Alan","family":"Levine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Malbrain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5049-7885","authenticated-orcid":false,"given":"Johan","family":"Stiens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0449-2375","authenticated-orcid":false,"given":"Wojciech","family":"Dabrowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leo C","family":"Mercer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1816-5255","authenticated-orcid":false,"given":"Manu L. N. G.","family":"Malbrain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,30]]},"reference":[{"issue":"3","key":"1430_CR1","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/ANC.0000000000000175","volume":"15","author":"BM Carter","year":"2015","unstructured":"Carter BM, Howard C. A 6th vital sign\u2014potential use of nasogastric tube for intra-abdominal pressure monitoring method to detect feeding intolerance in very low birth-weight preterm infants (<1500 g). Adv Neonatal Care. 2015;15(3):176\u201381.","journal-title":"Adv Neonatal Care"},{"issue":"1","key":"1430_CR2","doi-asserted-by":"publisher","DOI":"10.1186\/s13017-024-00564-5","volume":"19","author":"P Nasa","year":"2024","unstructured":"Nasa P, Wise RD, Smit M, Acosta S, D\u2019Amours S, Beaubien-Souligny W, et al. International cross-sectional survey on current and updated definitions of intra-abdominal hypertension and abdominal compartment syndrome. World J Emerg Surg. 2024;19(1):39.","journal-title":"World J Emerg Surg"},{"issue":"2","key":"1430_CR3","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1007\/s10877-022-00933-y","volume":"37","author":"W Dabrowski","year":"2023","unstructured":"Dabrowski W, Rola P, Malbrain MLNG. Intra-abdominal pressure monitoring in cardiac surgery: is this the canary in the coalmine for kidney injury? J Clin Monit Comput. 2023;37(2):351\u20138.","journal-title":"J Clin Monit Comput"},{"issue":"2","key":"1430_CR4","doi-asserted-by":"publisher","first-page":"83","DOI":"10.5603\/AIT.a2017.0019","volume":"49","author":"AW Kirkpatrick","year":"2017","unstructured":"Kirkpatrick AW, Sugrue M, McKee JL, Pereira BM, Roberts DJ, De Waele JJ, et al. Update from the Abdominal Compartment Society (WSACS) on intra-abdominal hypertension and abdominal compartment syndrome: past, present, and future beyond Banff 2017. Anaesthesiol Intensive Ther. 2017;49(2):83\u20137.","journal-title":"Anaesthesiol Intensive Ther"},{"issue":"3","key":"1430_CR5","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1179\/acb.2009.036","volume":"64","author":"JJ De Waele","year":"2009","unstructured":"De Waele JJ, Cheatham ML, Malbrain MLNG, Kirkpatrick AW, Sugrue M, Balogh Z, et al. Recommendations for research from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. Acta Clin Belg. 2009;64(3):203\u20139.","journal-title":"Acta Clin Belg"},{"issue":"5","key":"1430_CR6","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1001\/archsurg.1995.01430050094016","volume":"130","author":"F Obeid","year":"1995","unstructured":"Obeid F, Saba A, Fath J, Guslits B, Chung R, Sorensen V, et al. Increases in intra-abdominal pressure affect pulmonary compliance. Arch Surg. 1995;130(5):544\u20137 (discussion 547-548).","journal-title":"Arch Surg"},{"issue":"09","key":"1430_CR7","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1055\/s-2007-1001421","volume":"30","author":"S Yol","year":"1998","unstructured":"Yol S, Kartal A, Tavli \u015e, Tatkan Y. Is urinary bladder pressure a sensitive indicator of intra-abdominal pressure? Endoscopy. 1998;30(09):778\u201380.","journal-title":"Endoscopy"},{"issue":"6","key":"1430_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/cc366","volume":"3","author":"S Johna","year":"1999","unstructured":"Johna S, Taylor E, Brown C, Zimmerman G. Abdominal compartment syndrome: does intra-cystic pressure reflect actual intra-abdominal pressure? A prospective study in surgical patients. Crit Care. 1999;3(6):135.","journal-title":"Crit Care"},{"issue":"2","key":"1430_CR9","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1097\/00005373-200102000-00016","volume":"50","author":"MA Fusco","year":"2001","unstructured":"Fusco MA, Martin RS, Chang MC. Estimation of intra-abdominal pressure by bladder pressure measurement: validity and methodology. J Trauma Acute Care Surg. 2001;50(2):297\u2013302.","journal-title":"J Trauma Acute Care Surg"},{"issue":"6","key":"1430_CR10","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1097\/00005373-200206000-00024","volume":"52","author":"SL Lee","year":"2002","unstructured":"Lee SL, Anderson JT, Kraut EJ, Wisner DH, Wolfe BM. A simplified approach to the diagnosis of elevated intra-abdominal pressure. J Trauma. 2002;52(6):1169\u201372.","journal-title":"J Trauma"},{"issue":"9","key":"1430_CR11","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1007\/s00134-003-1847-3","volume":"29","author":"A Schachtrupp","year":"2003","unstructured":"Schachtrupp A, Tons C, Fackeldey V, Hoer J, Reinges M, Schumpelick V. Evaluation of two novel methods for the direct and continuous measurement of the intra-abdominal pressure in a porcine model. Intensive Care Med. 2003;29(9):1605\u20138.","journal-title":"Intensive Care Med"},{"issue":"3","key":"1430_CR12","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1097\/01.CCM.0000198526.04530.36","volume":"34","author":"A Schachtrupp","year":"2006","unstructured":"Schachtrupp A, Henzler D, Orfao S, Schaefer W, Schwab R, Becker P, et al. Evaluation of a modified piezoresistive technique and a water-capsule technique for direct and continuous measurement of intra-abdominal pressure in a porcine model. Crit Care Med. 2006;34(3):745\u201350.","journal-title":"Crit Care Med"},{"key":"1430_CR13","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1186\/1471-230X-10-70","volume":"10","author":"SM Jakob","year":"2010","unstructured":"Jakob SM, Knuesel R, Tenhunen JJ, Pradl R, Takala J. Increasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures. BMC Gastroenterol. 2010;10:70.","journal-title":"BMC Gastroenterol"},{"key":"1430_CR14","doi-asserted-by":"crossref","unstructured":"Cresswell AB, Jassem W, Srinivasan P, Prachalias AA, Sizer E, Burnal W, Auzinger G, Muiesan P, Rela M, Heaton ND et al: The effect of body position on compartmental intra-abdominal pressure following liver transplantation. Ann Intensive Care 2012, 2 Suppl 1(Suppl 1):S12","DOI":"10.1186\/2110-5820-2-S1-S12"},{"issue":"1","key":"1430_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-018-0539-z","volume":"18","author":"AA Al-Abassi","year":"2018","unstructured":"Al-Abassi AA, Al Saadi AS, Ahmed F. Is intra-bladder pressure measurement a reliable indicator for raised intra-abdominal pressure? A prospective comparative study. BMC Anesthesiol. 2018;18(1):69.","journal-title":"BMC Anesthesiol"},{"issue":"4","key":"1430_CR16","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1007\/s10877-021-00728-7","volume":"36","author":"S Hamoud","year":"2022","unstructured":"Hamoud S, Abdelgani S, Mekel M, Kinaneh S, Mahajna A. Gastric and urinary bladder pressures correlate with intra-abdominal pressure in patients with morbid obesity. J Clin Monit Comput. 2022;36(4):1021\u20138.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1430_CR17","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-95512-x","volume":"15","author":"B Ple\u0161nik","year":"2025","unstructured":"Ple\u0161nik B, Djoki\u0107 M, Djordjevi\u0107 S, Kra\u0161na S, \u017dumer J, Trotov\u0161ek B. Non-invasive and continuous intra-abdominal pressure assessment using MC sensors. Sci Rep. 2025;15(1):10775.","journal-title":"Sci Rep"},{"issue":"19","key":"1430_CR18","doi-asserted-by":"publisher","first-page":"6260","DOI":"10.3390\/jcm12196260","volume":"12","author":"S Tayebi","year":"2023","unstructured":"Tayebi S, Wise R, Zarghami A, Malbrain L, Khanna AK, Dabrowski W, et al. In vitro validation of a novel continuous intra-abdominal pressure measurement system (TraumaGuard). J Clin Med (Basel). 2023;12(19):6260.","journal-title":"J Clin Med (Basel)"},{"issue":"21","key":"1430_CR19","doi-asserted-by":"publisher","first-page":"8806","DOI":"10.3390\/s23218806","volume":"23","author":"S Tayebi","year":"2023","unstructured":"Tayebi S, McKinney T, McKinney C, Delvadia D, Levine M-A, Spofford ES, et al. Evaluation of the traumaGuard balloon-in-balloon catheter design for intra-abdominal pressure monitoring: insights from pig and human cadaver studies. Sensors (Basel). 2023;23(21):8806.","journal-title":"Sensors (Basel)"},{"issue":"16","key":"1430_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/s24165431","volume":"24","author":"S Tayebi","year":"2024","unstructured":"Tayebi S, Wise R, Zarghami A, Dabrowski W, Malbrain MLNG, Stiens J. An introduction to Ventra: a programmable abdominal phantom for training, educational, research, and development purposes. Sensors (Basel). 2024;24(16):5431.","journal-title":"Sensors (Basel)"},{"issue":"1","key":"1430_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s13017-025-00644-0","volume":"20","author":"S Tayebi","year":"2025","unstructured":"Tayebi S, Wise R, Nasa P, Malbrain L, Stiens J, Dabrowski W, et al. Variation and accuracy of intra-abdominal pressure measurement in different body positions: a prospective study. World J Emerg Surg. 2025;20(1):71.","journal-title":"World J Emerg Surg"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01430-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-026-01430-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01430-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T12:12:01Z","timestamp":1784722321000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-026-01430-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,30]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["1430"],"URL":"https:\/\/doi.org\/10.1007\/s10877-026-01430-2","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,30]]},"assertion":[{"value":"9 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was approved by the local Institutional Review Board and the ethics committee at Hurley Medical Center (approval number 1201431\u20133). To ensure ethical compliance and respect for patient autonomy, written informed consent was diligently obtained from the patients or their legally authorized representatives before their inclusion in the study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"M.L.N.G.M. is a Professor of Critical Care Research in the 1st Department of Anaesthesiology and Intensive Therapy, Medical University of Lublin, Poland. He is a co-founder, past President, and current Treasurer of The Abdominal Compartment Society (WSACS,\n                      \n                      ). He is a member of the Medical Advisory Board of Pulsion Medical Systems (part of the Getinge Group), Serenno Medical, Potrero Medical, Sentinel Medical Technologies, and Baxter, and consults for B. Braun, Becton Dickinson, ConvaTec, Spiegelberg, Medtronic, and Holtech Medical. He holds stock options for Serenno Medical, Sentinel Medical and Potrero Medical. He received speaker\u2019s fees from PeerVoice. He is a co-founder and the President of the International Fluid Academy (IFA). The IFA (\n                      \n                      ) is integrated into the not-for-profit charitable organization \u201cInternational Medical Education and Research Initiative (iMERiT) under Belgian law. The other authors have no potential conflicts of interest in relation to the contents of this paper.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}]}}