{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T10:05:32Z","timestamp":1789639532799,"version":"4.0.0"},"reference-count":211,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T00:00:00Z","timestamp":1789603200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T00:00:00Z","timestamp":1789603200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-026-01489-x","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T09:53:13Z","timestamp":1789638793000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Intraoperative electromyography (EMG): an updated position statement by the American Society of Neurophysiological Monitoring"],"prefix":"10.1007","author":[{"given":"Kent","family":"Rice","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanley","family":"Skinner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ernest M.","family":"Hoffman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuya","family":"Oishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lanjun","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ronald","family":"Leppanen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,17]]},"reference":[{"issue":"6","key":"1489_CR1","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s10877-005-0086-2","volume":"19","author":"RE Leppanen","year":"2005","unstructured":"Leppanen RE. Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2005;19(6):437\u201361. https:\/\/doi.org\/10.1007\/s10877-005-0086-2","journal-title":"J Clin Monit Comput"},{"key":"1489_CR2","unstructured":"Krause F. Surgery of the brain and spinal cord v.2, 1912. Rebman; 1912."},{"key":"1489_CR3","first-page":"340","volume":"69","author":"GJ Jako","year":"1965","unstructured":"Jako GJ. Facial nerve monitor. Trans Am Acad Ophthalmol Otolaryngol. 1965;69:340\u20132.","journal-title":"Trans Am Acad Ophthalmol Otolaryngol"},{"issue":"5","key":"1489_CR4","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1227\/00006123-197905000-00007","volume":"4","author":"TE Delgado","year":"1979","unstructured":"Delgado TE, Bucheit WA, Rosenholtz HR, Chrissian S. Intraoperative monitoring of facila muscle evoked responses obtained by intracranial stimulation of the facila nerve: a more accurate technique for facila nerve dissection. Neurosurgery. 1979;4(5):418\u201321. https:\/\/doi.org\/10.1227\/00006123-197905000-00007","journal-title":"Neurosurgery"},{"issue":"1","key":"1489_CR5","first-page":"23","volume":"22","author":"VA Fasano","year":"1976","unstructured":"Fasano VA, Barolat-Romana G, Ivaldi A, Sguazzi A. [Functional posterior radiculotomy, in the treatment of cerebral spasticity. peroperative electric stimulation of posterior roots and its use in the choice of the roots to be sectioned]. Neurochirurgie. 1976;22(1):23\u201334.","journal-title":"Neurochirurgie"},{"issue":"2","key":"1489_CR6","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1085\/jgp.46.2.297","volume":"46","author":"FJ Julian","year":"1962","unstructured":"Julian FJ, Goldman DE. The effects of mechanical stimulation on some electrical properties of axons. J Gen Physiol. 1962;46(2):297\u2013313.","journal-title":"J Gen Physiol"},{"key":"1489_CR7","first-page":"596","volume":"106","author":"ED Adrian","year":"1930","unstructured":"Adrian ED. The effects of injury on mammalian nerve fibers. Proc R Soc (Series B). 1930;106:596\u2013618.","journal-title":"Proc R Soc (Series B)"},{"key":"1489_CR8","doi-asserted-by":"publisher","unstructured":"Kugelberg E. Injury activity and trigger zones in human nerves. Brain. 1946;69(4):310\u2009\u2013\u200924. https:\/\/doi.org\/10.1093\/brain\/69.4.310","DOI":"10.1093\/brain\/69.4.310"},{"issue":"4","key":"1489_CR9","first-page":"204","volume":"3","author":"A Rosenblueth","year":"1953","unstructured":"Rosenblueth A, Buylla RA, Ramos JG. The responses of axons to mechanical stimuli. Acta Physiol Lat Am. 1953;3(4):204\u201315.","journal-title":"Acta Physiol Lat Am"},{"issue":"4","key":"1489_CR10","doi-asserted-by":"publisher","first-page":"757","DOI":"10.3171\/jns.1984.61.4.0757","volume":"61","author":"AR Moller","year":"1984","unstructured":"Moller AR, Jannetta PJ. Preservation of facial function during removal of acoustic neuromas. Use of monopolar constant-voltage stimulation and EMG. J Neurosurg. 1984;61(4):757\u201360. https:\/\/doi.org\/10.3171\/jns.1984.61.4.0757","journal-title":"J Neurosurg"},{"issue":"6","key":"1489_CR11","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1177\/019459988709700605","volume":"97","author":"RL Prass","year":"1987","unstructured":"Prass RL, Kinney SE, Hardy RW Jr, Hahn JF, L\u00fcders H. Acoustic (loudspeaker) facial EMG monitoring: II. Use of evoked EMG activity during acoustic neuroma resection. Otolaryngol Head Neck Surg. 1987;97(6):541\u201351. https:\/\/doi.org\/10.1177\/019459988709700605","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"3","key":"1489_CR12","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/00006123-198609000-00010","volume":"19","author":"RL Prass","year":"1986","unstructured":"Prass RL, L\u00fcders H. Acoustic (loudspeaker) facial electromyographic monitoring: Part 1. Evoked electromyographic activity during acoustic neuroma resection. Neurosurgery. 1986;19(3):392\u2013400. https:\/\/doi.org\/10.1097\/00006123-198609000-00010","journal-title":"Neurosurgery"},{"issue":"24","key":"1489_CR13","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1097\/00007632-199412150-00008","volume":"19","author":"B Calancie","year":"1994","unstructured":"Calancie B, Madsen P, Lebwohl N. Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results. Spine (Phila Pa 1976). 1994;19(24):2780\u20136. https:\/\/doi.org\/10.1097\/00007632-199412150-00008","journal-title":"Spine (Phila Pa 1976)"},{"issue":"15","key":"1489_CR14","doi-asserted-by":"publisher","first-page":"1704","DOI":"10.1097\/00007632-199408000-00009","volume":"19","author":"JH Owen","year":"1994","unstructured":"Owen JH, Kostuik JP, Gornet M, Petr M, Skelly J, Smoes C, Szymanski J, Townes J, Wolfe F. The use of mechanically elicited electromyograms to protect nerve roots during surgery for spinal degeneration. Spine (Phila Pa 1976). 1994;19(15):1704\u201310. https:\/\/doi.org\/10.1097\/00007632-199408000-00009","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"1489_CR15","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1159\/000140989","volume":"23","author":"B Feinstein","year":"1955","unstructured":"Feinstein B, Lindegard B, Nyman E, Wohlfart G. Morphologic studies of motor units in normal human muscles. Acta Anat (Basel). 1955;23(2):127\u201342. https:\/\/doi.org\/10.1159\/000140989","journal-title":"Acta Anat (Basel)"},{"issue":"2","key":"1489_CR16","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s10877-008-9114-3","volume":"22","author":"SA Skinner","year":"2008","unstructured":"Skinner SA, Transfeldt EE, Savik K. Surface electrodes are not sufficient to detect neurotonic discharges: observations in a porcine model and clinical review of deltoid electromyographic monitoring using multiple electrodes. J Clin Monit Comput. 2008;22(2):131\u20139. https:\/\/doi.org\/10.1007\/s10877-008-9114-3.","journal-title":"J Clin Monit Comput"},{"key":"1489_CR17","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.jevs.2018.05.218","volume":"68","author":"J Rijckaert","year":"2018","unstructured":"Rijckaert J, Pardon B, Van Ham L, van Loon G, Deprez P. Magnetic motor evoked potential recording in horses using intramuscular needle electrodes and surface electrodes. J Equine Vet Sci. 2018;68:101\u20137. https:\/\/doi.org\/10.1016\/j.jevs.2018.05.218.","journal-title":"J Equine Vet Sci"},{"issue":"8","key":"1489_CR18","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1002\/mus.880180803","volume":"18","author":"AJ Gitter","year":"1995","unstructured":"Gitter AJ, Stolov WC. AAEM minimonograph #16: instrumentation and measurement in electrodiagnostic medicine\u2013Part I. Muscle Nerve. 1995;18(8):799\u2013811. https:\/\/doi.org\/10.1002\/mus.880180803.","journal-title":"Muscle Nerve"},{"key":"1489_CR19","doi-asserted-by":"publisher","unstructured":"Daube JR, Rubin DI. Needle electromyography. Muscle Nerve. 2009;39(2). https:\/\/doi.org\/10.1002\/mus.21180. 244\u2009\u2013\u200970.","DOI":"10.1002\/mus.21180"},{"key":"1489_CR20","doi-asserted-by":"publisher","unstructured":"Buchthal F, Pinell P, Rosenfalck P. Action potential parameters in normal human muscle and their physiological determinants. Acta Physiol Scand. 1954;32(2\u20133). https:\/\/doi.org\/10.1111\/j.1748-1716.1954.tb01168.x. 219\u2009\u2013\u200929.","DOI":"10.1111\/j.1748-1716.1954.tb01168.x"},{"issue":"1","key":"1489_CR21","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.clinph.2019.07.025","volume":"131","author":"H Tankisi","year":"2020","unstructured":"Tankisi H, Burke D, Cui L, et al. Standards of instrumentation of EMG. Clin Neurophysiol. 2020;131(1):243\u201358. https:\/\/doi.org\/10.1016\/j.clinph.2019.07.025.","journal-title":"Clin Neurophysiol"},{"issue":"3","key":"1489_CR22","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1002\/mus.25203","volume":"54","author":"S Chen","year":"2016","unstructured":"Chen S, Andary M, Buschbacher R, Del Toro D, Smith B, So Y, Zimmermann K, Dillingham TR. Electrodiagnostic reference values for upper and lower limb nerve conduction studies in adult populations. Muscle Nerve. 2016;54(3):371\u20137. https:\/\/doi.org\/10.1002\/mus.25203.","journal-title":"Muscle Nerve"},{"issue":"5","key":"1489_CR23","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1007\/s10877-024-01201-x","volume":"38","author":"JR Toleikis","year":"2024","unstructured":"Toleikis JR, Pace C, Jahangiri FR, Hemmer LB, Toleikis SC. Intraoperative somatosensory evoked potential (SEP) monitoring: an updated position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2024;38(5):1003\u201342. https:\/\/doi.org\/10.1007\/s10877-024-01201-x.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"1489_CR24","doi-asserted-by":"publisher","first-page":"e271","DOI":"10.1016\/j.wneu.2011.09.026","volume":"80","author":"MA Acioly","year":"2013","unstructured":"Acioly MA, Liebsch M, de Aguiar PH, Tatagiba M. Facial nerve monitoring during cerebellopontine angle and skull base tumor surgery: a systematic review from description to current success on function prediction. World Neurosurg. 2013;80(6):e271\u2013300. https:\/\/doi.org\/10.1016\/j.wneu.2011.09.026.","journal-title":"World Neurosurg"},{"issue":"4","key":"1489_CR25","doi-asserted-by":"publisher","first-page":"624","DOI":"10.3171\/2015.6.spine141323","volume":"24","author":"AL Mikula","year":"2016","unstructured":"Mikula AL, Williams SK, Anderson PA. The use of intraoperative triggered electromyography to detect misplaced pedicle screws: a systematic review and meta-analysis. J Neurosurg Spine. 2016;24(4):624\u201338. https:\/\/doi.org\/10.3171\/2015.6.spine141323.","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"1489_CR26","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1136\/jnnp.36.1.75","volume":"36","author":"JL Veale","year":"1973","unstructured":"Veale JL, Mark RF, Rees S. Differential sensitivity of motor and sensory fibres in human ulnar nerve. J Neurol Neurosurg Psychiatry. 1973;36(1):75\u201386. https:\/\/doi.org\/10.1136\/jnnp.36.1.75.","journal-title":"J Neurol Neurosurg Psychiatry"},{"issue":"19","key":"1489_CR27","doi-asserted-by":"publisher","first-page":"2526","DOI":"10.1097\/00007632-200010010-00016","volume":"25","author":"RE Minahan","year":"2000","unstructured":"Minahan RE, Riley LH 3rd, Lukaczyk T, Cohen DB, Kostuik JP. The effect of neuromuscular blockade on pedicle screw stimulation thresholds. Spine (Phila Pa 1976). 2000;25(19):2526\u201330. https:\/\/doi.org\/10.1097\/00007632-200010010-00016.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"21","key":"1489_CR28","doi-asserted-by":"publisher","first-page":"2547","DOI":"10.1097\/00007632-199711010-00016","volume":"22","author":"NR Holland","year":"1997","unstructured":"Holland NR, Kostuik JP. Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery. Spine (Phila Pa 1976). 1997;22(21):2547\u201350. https:\/\/doi.org\/10.1097\/00007632-199711010-00016.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"1489_CR29","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1097\/00002517-200008000-00003","volume":"13","author":"JR Toleikis","year":"2000","unstructured":"Toleikis JR, Skelly JP, Carlvin AO, Toleikis SC, Bernard TN, Burkus JK, Burr ME, Dorchak JD, Goldman MS, Walsh TR. The usefulness of electrical stimulation for assessing pedicle screw placements. J Spinal Disord. 2000;13(4):283\u20139. https:\/\/doi.org\/10.1097\/00002517-200008000-00003.","journal-title":"J Spinal Disord"},{"issue":"Suppl 1","key":"1489_CR30","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1002\/lary.21119","volume":"121","author":"GW Randolph","year":"2011","unstructured":"Randolph GW, Dralle H, International Intraoperative Monitoring Study Group. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 2011;121(Suppl 1):S1\u201316. https:\/\/doi.org\/10.1002\/lary.21119.","journal-title":"Laryngoscope"},{"issue":"Suppl 4","key":"1489_CR31","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1002\/lary.29459","volume":"131","author":"JM Kartush","year":"2021","unstructured":"Kartush JM, Rice KS, Minahan RE, Balzer GK, Yingling CD, Seubert CN. Best practices in facial nerve monitoring. Laryngoscope. 2021;131(Suppl 4):S1\u201342. https:\/\/doi.org\/10.1002\/lary.29459.","journal-title":"Laryngoscope"},{"issue":"7","key":"1489_CR32","doi-asserted-by":"publisher","first-page":"e26","DOI":"10.1097\/wnp.0000000000000962","volume":"39","author":"Z Wehab","year":"2022","unstructured":"Wehab Z, Tabarestani TQ, Abd-El-Barr MM, Husain AM. Intraoperative electromyography in awake minimally invasive transforaminal lumbar interbody fusion: A case study on nerve activation under the effects of local anesthesia. J Clin Neurophysiol. 2022;39(7):e26\u20139. https:\/\/doi.org\/10.1097\/wnp.0000000000000962.","journal-title":"J Clin Neurophysiol"},{"issue":"12","key":"1489_CR33","doi-asserted-by":"publisher","first-page":"3719","DOI":"10.1007\/s00586-021-07059-w","volume":"31","author":"K Guna Pratheep","year":"2022","unstructured":"Guna Pratheep K, Sonawane K, Rajasekaran S, Shetty AP, Subramanian BJ, Kanna RM. Transient paraplegia in lumbar spine surgery-a potential complication following erector spinae plane block. Eur Spine J. 2022;31(12):3719\u201323. https:\/\/doi.org\/10.1007\/s00586-021-07059-w.","journal-title":"Eur Spine J"},{"key":"1489_CR34","first-page":"1127","volume-title":"Electrodiagnostic Medicine","author":"D Dumitru","year":"2001","unstructured":"Dumitru D, Amato AA (2001) Neuromuscular junction disorders. In: Dumitru D, Amato AA, Zwark M (eds.)Electrodiagnostic Medicine. Philadelphia: Hanly & Belfus, Inc.;pp. 1127\u2013227."},{"key":"1489_CR35","unstructured":"Kimura J. Anatomy and physiology of the neuromuscular junction, in Electrodiagnosis in diseases of nerve and muscle: Principles and practice. 1983: Philadelphia. pp. 171\u2013188."},{"key":"1489_CR36","unstructured":"Silverman DG. Neuromuscular block: In Perioperative and Intensive Care. Lippincott Williams & Wilkins; 1994."},{"issue":"6","key":"1489_CR37","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1097\/wnp.0000000000000111","volume":"31","author":"B Gavrancic","year":"2014","unstructured":"Gavrancic B, Lolis A, Beric A. Train-of-four test in intraoperative neurophysiologic monitoring: differences between hand and foot train-of-four. J Clin Neurophysiol. 2014;31(6):575\u20139. https:\/\/doi.org\/10.1097\/wnp.0000000000000111.","journal-title":"J Clin Neurophysiol"},{"key":"1489_CR38","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/B978-0-12-819826-1.00002-8","volume":"186","author":"J Prell","year":"2022","unstructured":"Prell J, Skinner S. EMG monitoring. Handb Clin Neurol. 2022;186:67\u201381.","journal-title":"Handb Clin Neurol"},{"issue":"1","key":"1489_CR39","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1288\/00005537-198601000-00012","volume":"96","author":"SG Harner","year":"1986","unstructured":"Harner SG, Daube JR, Ebersold MJ. Electrophysiologic monitoring of facial nerve during temporal bone surgery. Laryngoscope. 1986;96(1):65\u20139. https:\/\/doi.org\/10.1288\/00005537-198601000-00012.","journal-title":"Laryngoscope"},{"issue":"2","key":"1489_CR40","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/s0025-6196(12)61876-x","volume":"62","author":"SG Harner","year":"1987","unstructured":"Harner SG, Daube JR, Ebersold MJ, Beatty CW. Improved preservation of facial nerve function with use of electrical monitoring during removal of acoustic neuromas. Mayo Clin Proc. 1987;62(2):92\u2013102. https:\/\/doi.org\/10.1016\/s0025-6196(12)61876-x.","journal-title":"Mayo Clin Proc"},{"key":"1489_CR41","doi-asserted-by":"publisher","unstructured":"Romst\u00f6ck J, Strauss C, Fahlbusch R. Continuous electromyography monitoring of motor cranial nerves during cerebellopontine angle surgery. J Neurosurg. 2000;93(4):586\u2009\u2013\u200993. https:\/\/doi.org\/10.3171\/jns.2000.93.4.0586.","DOI":"10.3171\/jns.2000.93.4.0586"},{"key":"1489_CR42","doi-asserted-by":"publisher","unstructured":"Prell J, et al. Train time as a quantitative electromyographic parameter for facial nerve function in patients undergoing surgery for vestibular schwannoma. J Neurosurg. 2007;106(5):826\u2009\u2013\u200932. https:\/\/doi.org\/10.3171\/jns.2007.106.5.826","DOI":"10.3171\/jns.2007.106.5.826"},{"key":"1489_CR43","doi-asserted-by":"publisher","unstructured":"Skinner SA, Transfeldt EE. Electromyography in the detection of mechanically induced spinal motor tract injury: observations in diverse porcine models. J Neurosurg Spine. 2009;11(3):369\u2009\u2013\u200974. https:\/\/doi.org\/10.3171\/2009.3.spine08881.\u00a0","DOI":"10.3171\/2009.3.spine08881"},{"key":"1489_CR44","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/B978-0-12-819826-1.00005-3","volume":"186","author":"S Skinner","year":"2022","unstructured":"Skinner S, Guo L. Intraoperative neuromonitoring during surgery for lumbar stenosis. Handb Clin Neurol. 2022;186:205\u201327. https:\/\/doi.org\/10.1016\/B978-0-12-819826-1.00005-3.","journal-title":"Handb Clin Neurol"},{"key":"1489_CR45","doi-asserted-by":"publisher","unstructured":"Skinner SA. Neurophysiologic monitoring of the spinal accessory nerve, hypoglossal nerve, and the spinomedullary region. J Clin Neurophysiol. 2011;28(6):587\u2009\u2013\u200998. https:\/\/doi.org\/10.1097\/wnp.0b013e31824079b3.\u00a0","DOI":"10.1097\/wnp.0b013e31824079b3"},{"key":"1489_CR46","doi-asserted-by":"publisher","unstructured":"Skinner SA, Nagib M, Bergman TA, Maxwell RE, Msangi G. The initial use of free-running electromyography to detect early motor tract injury during resection of intramedullary spinal cord lesions. Neurosurgery, 2005. 56(2 Suppl): pp. 299\u2013314; discussion 299\u2013314. https:\/\/doi.org\/10.1227\/01.neu.0000156545.33814.8d","DOI":"10.1227\/01.neu.0000156545.33814.8d"},{"issue":"2","key":"1489_CR47","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/s10877-012-9417-2","volume":"27","author":"SA Skinner","year":"2013","unstructured":"Skinner SA, Hsu B, Transfeldt EE, Mehbod AA, Rippe DM, Wu C, Erkan S. Spinal cord injury from electrocautery: observations in a porcine model using electromyography and motor evoked potentials. J Clin Monit Comput. 2013;27(2):195\u2013201. https:\/\/doi.org\/10.1007\/s10877-012-9417-2.","journal-title":"J Clin Monit Comput"},{"issue":"4","key":"1489_CR48","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1016\/j.clinph.2008.11.030","volume":"120","author":"SA Skinner","year":"2009","unstructured":"Skinner SA, Transfeldt EE, Mehbod AA, Mullan JC, Perra JH. Electromyography detects mechanically-induced suprasegmental spinal motor tract injury: review of decompression at spinal cord level. Clin Neurophysiol. 2009;120(4):754\u201364. https:\/\/doi.org\/10.1016\/j.clinph.2008.11.030.","journal-title":"Clin Neurophysiol"},{"issue":"3","key":"1489_CR49","doi-asserted-by":"publisher","first-page":"730","DOI":"10.3171\/2024.1.jns231867","volume":"141","author":"T Oishi","year":"2024","unstructured":"Oishi T, Van Gompel JJ, Link MJ, Peris Celda M, Daniels DJ, Morris JM, Hoffman EM. Extraocular muscle electromyographic recordings for intraoperative monitoring of cranial nerves III, IV, and VI: a single-center experience with intraorbital electrodes. J Neurosurg. 2024;141(3):730\u201341. https:\/\/doi.org\/10.3171\/2024.1.jns231867.","journal-title":"J Neurosurg"},{"issue":"10","key":"1489_CR50","doi-asserted-by":"publisher","first-page":"2510","DOI":"10.1016\/j.clinph.2021.08.002","volume":"132","author":"T Oishi","year":"2021","unstructured":"Oishi T, Van Gompel JJ, Link MJ, Tooley AA, Hoffman EM. Intraoperative lateral rectus electromyographic recordings optimized by deep intraorbital needle electrodes. Clin Neurophysiol. 2021;132(10):2510\u20138. https:\/\/doi.org\/10.1016\/j.clinph.2021.08.002.","journal-title":"Clin Neurophysiol"},{"issue":"6","key":"1489_CR51","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1097\/wnp.0b013e31823e9b00","volume":"28","author":"R Singh","year":"2011","unstructured":"Singh R, Husain AM. Neurophysiologic intraoperative monitoring of the glossopharyngeal and vagus nerves. J Clin Neurophysiol. 2011;28(6):582\u20136. https:\/\/doi.org\/10.1097\/wnp.0b013e31823e9b00.","journal-title":"J Clin Neurophysiol"},{"issue":"4","key":"1489_CR52","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s10877-016-9904-y","volume":"31","author":"TL Trentman","year":"2017","unstructured":"Trentman TL, Thunberg C, Gorlin A, Koht A, Zimmerman RS, Bendok B. Insertion of intra-oral electrodes for cranial nerve monitoring using a Crowe-Davis retractor. J Clin Monit Comput. 2017;31(4):793\u20136. https:\/\/doi.org\/10.1007\/s10877-016-9904-y.","journal-title":"J Clin Monit Comput"},{"issue":"Suppl 3","key":"1489_CR53","doi-asserted-by":"publisher","first-page":"e342","DOI":"10.1055\/s-0040-1701649","volume":"82","author":"CJA Ferreira","year":"2021","unstructured":"Ferreira CJA, Sherer M, Anetakis K, Crammond DJ, Balzer JR, Thirumala PD. Neurophysiological characteristics of cranial Nerves V- and VII-triggered EMG in endoscopic endonasal approach skull base surgery. J Neurol Surg B Skull Base. 2021;82(Suppl 3):e342\u20138. https:\/\/doi.org\/10.1055\/s-0040-1701649.","journal-title":"J Neurol Surg B Skull Base"},{"issue":"2","key":"1489_CR54","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/S0030-6665(20)30994-4","volume":"25","author":"CD Yingling","year":"1992","unstructured":"Yingling CD, Gardi JN. Intraoperative monitoring of facial and cochlear nerves during acoustic neuroma surgery. Otolaryngol Clin North Am. 1992;25(2):413\u201348.","journal-title":"Otolaryngol Clin North Am"},{"key":"1489_CR55","doi-asserted-by":"publisher","unstructured":"Sobottka SB, Schackert G, May SA, Wiegleb M, Reiss G. Intraoperative facial nerve monitoring (IFNM) predicts facial nerve outcome after resection of vestibular schwannoma. Acta Neurochir (Wien). 1998;140(3):235\u2009\u2013\u200942; discussion 242-3. https:\/\/doi.org\/10.1007\/s007010050090.\u00a0","DOI":"10.1007\/s007010050090"},{"key":"1489_CR56","doi-asserted-by":"publisher","unstructured":"Goldbrunner RH, Schlake HP, Milewski C, Tonn JC, Helms J, Roosen K. Quantitative parameters of intraoperative electromyography predict facial nerve outcomes for vestibular schwannoma surgery. Neurosurgery, 2000. 46(5): pp. 1140-6; discussion 1146-8. https:\/\/doi.org\/10.1097\/00006123-200005000-00023","DOI":"10.1097\/00006123-200005000-00023"},{"issue":"1","key":"1489_CR57","doi-asserted-by":"publisher","first-page":"206","DOI":"10.3171\/2012.10.jns12915","volume":"118","author":"WR Schmitt","year":"2013","unstructured":"Schmitt WR, Daube JR, Carlson ML, Mandrekar JN, Beatty CW, Neff BA, Driscoll CL, Link MJ. Use of supramaximal stimulation to predict facial nerve outcomes following vestibular schwannoma microsurgery: results from a decade of experience. J Neurosurg. 2013;118(1):206\u201312. https:\/\/doi.org\/10.3171\/2012.10.jns12915.","journal-title":"J Neurosurg"},{"issue":"2","key":"1489_CR58","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1227\/00006123-199508000-00010","volume":"37","author":"W Eisner","year":"1995","unstructured":"Eisner W, Schmid UD, Reulen HJ, Oeckler R, Olteanu-Nerbe V, Gall C, Kothbauer K. The mapping and continuous monitoring of the intrinsic motor nuclei during brain stem surgery. Neurosurgery. 1995;37(2):255\u201365. https:\/\/doi.org\/10.1227\/00006123-199508000-00010.","journal-title":"Neurosurgery"},{"key":"1489_CR59","doi-asserted-by":"publisher","unstructured":"Katsuta T, Morioka T, Fujii K, Fukui M. Physiological localization of the facial colliculus during direct surgery on an intrinsic brain stem lesion. Neurosurgery, 1993. 32(5): pp. 861-3; comment 863. https:\/\/doi.org\/10.1227\/00006123-199305000-00025","DOI":"10.1227\/00006123-199305000-00025"},{"issue":"5","key":"1489_CR60","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1227\/00006123-199511000-00011","volume":"37","author":"N Morota","year":"1995","unstructured":"Morota N, et al. Brain stem mapping: neurophysiological localization of motor nuclei on the floor of the fourth ventricle. Neurosurgery. 1995;37(5):922\u20139. https:\/\/doi.org\/10.1227\/00006123-199511000-00011. discussion 929\u2009\u2013\u200930.","journal-title":"Neurosurgery"},{"key":"1489_CR61","doi-asserted-by":"publisher","unstructured":"Morota N, Deletis V, Epstein FJ, Kofler M, Abbott R, Lee M, Ruskin K. Functional anatomic relationship between brain-stem tumors and cranial motor nuclei. Neurosurgery. 1996;39(4):787\u2009\u2013\u200993; discussion 793-4. https:\/\/doi.org\/10.1097\/00006123-199610000-00028.\u00a0","DOI":"10.1097\/00006123-199610000-00028"},{"issue":"6","key":"1489_CR62","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/j.neucli.2007.09.013","volume":"37","author":"F Sala","year":"2007","unstructured":"Sala F, Manganotti P, Tramontano V, Bricolo A, Gerosa M. Monitoring of motor pathways during brain stem surgery: what we have achieved and what we still miss? Neurophysiol Clin. 2007;37(6):399\u2013406. https:\/\/doi.org\/10.1016\/j.neucli.2007.09.013.","journal-title":"Neurophysiol Clin"},{"issue":"5","key":"1489_CR63","doi-asserted-by":"publisher","first-page":"e189","DOI":"10.1227\/ons.0000000000000120","volume":"22","author":"P Sharma","year":"2022","unstructured":"Sharma P, Sefcikova V, Sanders B, Soumpasis C, Waraich M, Samandouras G. Resection of ependymomas infiltrating the fourth ventricular floor: anatomosurgical and stimulation mapping techniques. Oper Neurosurg. 2022;22(5):e189\u201397. https:\/\/doi.org\/10.1227\/ons.0000000000000120.","journal-title":"Oper Neurosurg"},{"issue":"3","key":"1489_CR64","doi-asserted-by":"publisher","first-page":"393","DOI":"10.3171\/jns.1993.79.3.0393","volume":"79","author":"C Strauss","year":"1993","unstructured":"Strauss C, Romst\u00f6ck J, Nimsky C, Fahlbusch R. Intraoperative identification of motor areas of the rhomboid fossa using direct stimulation. J Neurosurg. 1993;79(3):393\u20139. https:\/\/doi.org\/10.3171\/jns.1993.79.3.0393.","journal-title":"J Neurosurg"},{"key":"1489_CR65","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/B978-012209036-3\/50016-0","volume-title":"Neurophysiology in neurosurgery","author":"N Morota","year":"2002","unstructured":"Morota N, Deletis V, Epstein FJ (2002) Brainstem mapping. In: Deletis V, Shils JL (eds.) Neurophysiology in neurosurgery. San Diego, CA: Academic, pp. 319\u201335."},{"issue":"7","key":"1489_CR66","doi-asserted-by":"publisher","first-page":"2704","DOI":"10.1016\/j.clinph.2016.04.020","volume":"127","author":"AM Kaufmann","year":"2016","unstructured":"Kaufmann AM, Wilkinson MF. The origin of the abnormal muscle response seen in hemifacial spasm remains controversial. Clin Neurophysiol. 2016;127(7):2704\u20135. https:\/\/doi.org\/10.1016\/j.clinph.2016.04.020.","journal-title":"Clin Neurophysiol"},{"issue":"2","key":"1489_CR67","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.neuchi.2017.12.004","volume":"64","author":"JP Lefaucheur","year":"2018","unstructured":"Lefaucheur JP. New insights into the pathophysiology of primary hemifacial spasm. Neurochirurgie. 2018;64(2):87\u201393. https:\/\/doi.org\/10.1016\/j.neuchi.2017.12.004.","journal-title":"Neurochirurgie"},{"issue":"1\u20132","key":"1489_CR68","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1007\/bf01402110","volume":"113","author":"AR Moller","year":"1991","unstructured":"Moller AR. The cranial nerve vascular compression syndrome: II. A review of pathophysiology. Acta Neurochir (Wien). 1991;113(1\u20132):24\u201330. https:\/\/doi.org\/10.1007\/bf01402110.","journal-title":"Acta Neurochir (Wien)"},{"issue":"2","key":"1489_CR69","doi-asserted-by":"publisher","first-page":"379","DOI":"10.3171\/2016.2.jns151384","volume":"126","author":"MF Wilkinson","year":"2017","unstructured":"Wilkinson MF, Chowdhury T, Mutch WA, Kaufmann AM. Analysis of facial motor evoked potentials for assessing a central mechanism in hemifacial spasm. J Neurosurg. 2017;126(2):379\u201385. https:\/\/doi.org\/10.3171\/2016.2.jns151384.","journal-title":"J Neurosurg"},{"key":"1489_CR70","doi-asserted-by":"publisher","unstructured":"Gardner WJ. Cross talk\u2013the paradoxical transmission of a nerve impulse. Arch Neurol. 1966;14(2):149\u2009\u2013\u200956. https:\/\/doi.org\/10.1001\/archneur.1966.00470080033005.\u00a0","DOI":"10.1001\/archneur.1966.00470080033005"},{"issue":"5","key":"1489_CR71","doi-asserted-by":"publisher","first-page":"2240","DOI":"10.1016\/j.clinph.2016.02.004","volume":"127","author":"S Kameyama","year":"2016","unstructured":"Kameyama S, Masuda H, Shirozu H, Ito Y, Sonoda M, Kimura J. Ephaptic transmission is the origin of the abnormal muscle response seen in hemifacial spasm. Clin Neurophysiol. 2016;127(5):2240\u20135. https:\/\/doi.org\/10.1016\/j.clinph.2016.02.004.","journal-title":"Clin Neurophysiol"},{"issue":"4","key":"1489_CR72","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2009.8.focus09142","volume":"27","author":"RF Sekula Jr","year":"2009","unstructured":"Sekula RF Jr, Bhatia S, Frederickson AM, Jannetta PJ, Quigley MR, Small GA, Breisinger R. Utility of intraoperative electromyography in microvascular decompression for hemifacial spasm: a meta-analysis. Neurosurg Focus. 2009;27(4):E10. https:\/\/doi.org\/10.3171\/2009.8.focus09142.","journal-title":"Neurosurg Focus"},{"issue":"4","key":"1489_CR73","doi-asserted-by":"publisher","first-page":"E473","DOI":"10.1093\/neuros\/nyaa069","volume":"87","author":"PD Thirumala","year":"2020","unstructured":"Thirumala PD, Altibi AM, Chang R, Saca EE, Iyengar P, Reddy R, Anetakis K, Crammond DJ, Balzer JR, Sekula RF. The utility of intraoperative lateral spread recording in microvascular decompression for hemifacial spasm: A Systematic Review and Meta-Analysis. Neurosurgery. 2020;87(4):E473\u201384. https:\/\/doi.org\/10.1093\/neuros\/nyaa069.","journal-title":"Neurosurgery"},{"issue":"6","key":"1489_CR74","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1016\/j.surg.2008.02.006","volume":"143","author":"FY Chiang","year":"2008","unstructured":"Chiang FY, Lu IC, Kuo WR, Lee KW, Chang NC, Wu CW. The mechanism of recurrent laryngeal nerve injury during thyroid surgery\u2013the application of intraoperative neuromonitoring. Surgery. 2008;143(6):743\u20139. https:\/\/doi.org\/10.1016\/j.surg.2008.02.006.","journal-title":"Surgery"},{"issue":"10","key":"1489_CR75","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1002\/hed.23154","volume":"35","author":"CW Wu","year":"2013","unstructured":"Wu CW, Dionigi G, Chen HC, Chen HY, Lee KW, Lu IC, Chang PY, Hsiao PJ, Ho KY, Chiang FY. Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery. Head Neck. 2013;35(10):1443\u20137. https:\/\/doi.org\/10.1002\/hed.23154.","journal-title":"Head Neck"},{"key":"1489_CR76","doi-asserted-by":"publisher","unstructured":"Jonas J. Continuous vagal nerve stimulation for recurrent laryngeal nerve protection in thyroid surgery. Eur Surg Res. 2010;44(3\u20134):185\u2009\u2013\u200991. https:\/\/doi.org\/10.1159\/000305233.\u00a0","DOI":"10.1159\/000305233"},{"issue":"4","key":"1489_CR77","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.amjsurg.2009.04.036","volume":"199","author":"R Schneider","year":"2010","unstructured":"Schneider R, Przybyl J, Pliquett U, Hermann M, Wehner M, Pietsch UC, K\u00f6nig F, Hauss J, Jonas S, Leinung S. A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve. Am J Surg. 2010;199(4):507\u201314. https:\/\/doi.org\/10.1016\/j.amjsurg.2009.04.036.","journal-title":"Am J Surg"},{"issue":"11","key":"1489_CR78","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.1002\/hed.23187","volume":"35","author":"R Schneider","year":"2013","unstructured":"Schneider R, Randolph GW, Sekulla C, Phelan E, Thanh PN, Bucher M, Machens A, Dralle H, Lorenz K. Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck. 2013;35(11):1591\u20138. https:\/\/doi.org\/10.1002\/hed.23187.","journal-title":"Head Neck"},{"issue":"3","key":"1489_CR79","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.surg.2007.10.007","volume":"143","author":"C Ulmer","year":"2008","unstructured":"Ulmer C, Koch KP, Seimer A, Molnar V, Meyding-Lamad\u00e9 U, Thon KP, Lamad\u00e9 W. Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial. Surgery. 2008;143(3):359\u201365. https:\/\/doi.org\/10.1016\/j.surg.2007.10.007.","journal-title":"Surgery"},{"issue":"3","key":"1489_CR80","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1016\/j.neubiorev.2005.01.004","volume":"29","author":"DA Groves","year":"2005","unstructured":"Groves DA, Brown VJ. Vagal nerve stimulation: a review of its applications and potential mechanisms that mediate its clinical effects. Neurosci Biobehav Rev. 2005;29(3):493\u2013500. https:\/\/doi.org\/10.1016\/j.neubiorev.2005.01.004.","journal-title":"Neurosci Biobehav Rev"},{"issue":"3","key":"1489_CR81","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1080\/13645700701383241","volume":"16","author":"W Lamad\u00e9","year":"2007","unstructured":"Lamad\u00e9 W, Ulmer C, Seimer A, Molnar V, Meyding-Lamad\u00e9 U, Thon KP, Koch KP. A new system for continuous recurrent laryngeal nerve monitoring. Minim Invasive Ther Allied Technol. 2007;16(3):149\u201354. https:\/\/doi.org\/10.1080\/13645700701383241.","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"2","key":"1489_CR82","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1001\/jamaoto.2013.6139","volume":"140","author":"DJ Genther","year":"2014","unstructured":"Genther DJ, Kandil EH, Noureldine SI, Tufano RP. Correlation of final evoked potential amplitudes on intraoperative electromyography of the recurrent laryngeal nerve with immediate postoperative vocal fold function after thyroid and parathyroid surgery. JAMA Otolaryngol Head Neck Surg. 2014;140(2):124\u20138. https:\/\/doi.org\/10.1001\/jamaoto.2013.6139.","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"issue":"6","key":"1489_CR83","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1097\/01.brs.0000115144.30607.e9","volume":"29","author":"T Gunnarsson","year":"2004","unstructured":"Gunnarsson T, Krassioukov AV, Sarjeant R, Fehlings MG. Real-time continuous intraoperative electromyographic and somatosensory evoked potential recordings in spinal surgery: correlation of clinical and electrophysiologic findings in a prospective, consecutive series of 213 cases. Spine (Phila Pa 1976). 2004;29(6):677\u201384. https:\/\/doi.org\/10.1097\/01.brs.0000115144.30607.e9.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"1489_CR84","doi-asserted-by":"publisher","first-page":"401","DOI":"10.3171\/jns.1995.82.3.0401","volume":"82","author":"RM Beatty","year":"1995","unstructured":"Beatty RM, McGuire P, Moroney JM, Holladay FP. Continuous intraoperative electromyographic recording during spinal surgery. J Neurosurg. 1995;82(3):401\u20135. https:\/\/doi.org\/10.3171\/jns.1995.82.3.0401.","journal-title":"J Neurosurg"},{"issue":"16","key":"1489_CR85","doi-asserted-by":"publisher","first-page":"E558","DOI":"10.1097\/brs.0b013e3181aa25a8","volume":"34","author":"R Lyon","year":"2009","unstructured":"Lyon R, Lieberman JA, Feiner J, Burch S. Relative efficacy of transcranial motor evoked potentials, mechanically-elicited electromyography, and evoked EMG to assess nerve root function during sustained retraction in a porcine model. Spine (Phila Pa 1976). 2009;34(16):E558\u201364. https:\/\/doi.org\/10.1097\/brs.0b013e3181aa25a8.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR86","doi-asserted-by":"publisher","unstructured":"Mok JM, Lyon R, Lieberman JA, Cloyd JM, Burch S. Monitoring of nerve root injury using transcranial motor-evoked potentials in a pig model. Spine (Phila Pa 1976)., Mok JM et al. Monitoring of nerve root injury using transcranial motor-evoked potentials in a pig model. Spine (Phila Pa 1976), 2008. 33(14): pp. E465-73. https:\/\/doi.org\/10.1097\/brs.0b013e318178e67f","DOI":"10.1097\/brs.0b013e318178e67f"},{"issue":"17","key":"1489_CR87","doi-asserted-by":"publisher","first-page":"E989","DOI":"10.1097\/brs.0000000000000442","volume":"39","author":"F Valone","year":"2014","unstructured":"Valone F 3rd, Lyon R, Lieberman J, Burch S. Efficacy of transcranial motor evoked potentials, mechanically elicited electromyography, and evoked electromyography to assess nerve root function during sustained compression in a porcine model. Spine (Phila Pa 1976). 2014;39(17):E989\u201393. https:\/\/doi.org\/10.1097\/brs.0000000000000442.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"1489_CR88","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/00007632-198401000-00004","volume":"9","author":"B Rydevik","year":"1984","unstructured":"Rydevik B, Brown MD, Lundborg G. Pathoanatomy and pathophysiology of nerve root compression. Spine (Phila Pa 1976). 1984;9(1):7\u201315. https:\/\/doi.org\/10.1097\/00007632-198401000-00004.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR89","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/17453679109153920","volume":"242","author":"K Olmarker","year":"1991","unstructured":"Olmarker K. Spinal nerve root compression. Nutrition and function of the porcine cauda equina compressed in vivo. Acta Orthop Scand Suppl. 1991;242:1\u201327.","journal-title":"Acta Orthop Scand Suppl"},{"key":"1489_CR90","unstructured":"Berthold C, Carlstedt T, Corneliuson O et al. Anatomy of the nerve root at the central-peripheral transitional region, in Peripheral neuropathy, P. Dyck, Editors. 1984, Saunders: Philadelphia. pp. 156\u2013170."},{"key":"1489_CR91","unstructured":"Dumitru D, Radiculopathies. in Electrodiagnostic medicine. 1995, Mosby: Baltimore. pp. 523\u2013584."},{"issue":"1","key":"1489_CR92","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3171\/2011.2.spine1068","volume":"15","author":"CM Schirmer","year":"2011","unstructured":"Schirmer CM, Shils JL, Arle JE, Cosgrove GR, Dempsey PK, Tarlov E, Kim S, Martin CJ, Feltz C, Moul M, Magge S. Heuristic map of myotomal innervation in humans using direct intraoperative nerve root stimulation. J Neurosurg Spine. 2011;15(1):64\u201370. https:\/\/doi.org\/10.3171\/2011.2.spine1068.","journal-title":"J Neurosurg Spine"},{"issue":"11","key":"1489_CR93","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1097\/00007632-199011010-00014","volume":"15","author":"H Matsuzaki","year":"1990","unstructured":"Matsuzaki H, Tokuhashi Y, Matsumoto F, Hoshino M, Kiuchi T, Toriyama S. Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine (Phila Pa 1976). 1990;15(11):1159\u201365. https:\/\/doi.org\/10.1097\/00007632-199011010-00014.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"1489_CR94","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1097\/00007632-198809000-00008","volume":"13","author":"JN Weinstein","year":"1988","unstructured":"Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976). 1988;13(9):1012\u20138. https:\/\/doi.org\/10.1097\/00007632-198809000-00008.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"1489_CR95","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1097\/00007632-199105000-00016","volume":"16","author":"JL West","year":"1991","unstructured":"West JL 3rd, Ogilvie JW, Bradford DS. Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976). 1991;16(5):576\u20139. https:\/\/doi.org\/10.1097\/00007632-199105000-00016.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"1489_CR96","doi-asserted-by":"publisher","first-page":"1229","DOI":"10.1097\/00007632-199210000-00017","volume":"17","author":"B Calancie","year":"1992","unstructured":"Calancie B, Lebwohl N, Madsen P, Klose KJ. Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement. Spine (Phila Pa 1976). 1992;17(10):1229\u201335. https:\/\/doi.org\/10.1097\/00007632-199210000-00017.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"1489_CR97","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1097\/00007632-199603010-00013","volume":"21","author":"DH Clements","year":"1996","unstructured":"Clements DH, Morledge DE, Martin WH, Betz RR. Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement. Spine (Phila Pa 1976). 1996;21(5):600\u20134 https:\/\/doi.org\/10.1097\/00007632-199603010-00013.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"1489_CR98","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1097\/00002517-199602000-00002","volume":"9","author":"BV Darden","year":"1996","unstructured":"Darden BV 2nd, Wood KE, Hatley MK, Owen JH, Kostuik J. Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography. J Spinal Disord. 1996;9(1):8\u201316.","journal-title":"J Spinal Disord"},{"key":"1489_CR99","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1097\/00003086-198602000-00011","volume":"203","author":"MH Krag","year":"1986","unstructured":"Krag MH, Beynnon BD, Pope MH, Frymoyer JW, Haugh LD, Weaver DL. An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. Clin Orthop Relat Res. 1986;203:75\u201398.","journal-title":"Clin Orthop Relat Res"},{"key":"1489_CR100","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1097\/00003086-198602000-00004","volume":"203","author":"R Louis","year":"1986","unstructured":"Louis R. Fusion of the lumbar and sacral spine by internal fixation with screw plates. Clin Orthop Relat Res. 1986;203:18\u201333.","journal-title":"Clin Orthop Relat Res"},{"key":"1489_CR101","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/00003086-198602000-00007","volume":"203","author":"ER Luque","year":"1986","unstructured":"Luque ER. Interpeduncular segmental fixation. Clin Orthop Relat Res. 1986;203:54\u20137.","journal-title":"Clin Orthop Relat Res"},{"key":"1489_CR102","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1097\/00003086-198410000-00014","volume":"189","author":"FP Magerl","year":"1984","unstructured":"Magerl FP. Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res. 1984;189:125\u201341.","journal-title":"Clin Orthop Relat Res"},{"key":"1489_CR103","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/00003086-198908000-00011","volume":"245","author":"TS Whitecloud","year":"1989","unstructured":"Whitecloud TS, Skalley TC, Cook SD, Morgan EL. Roentgenographic measurement of pedicle screw penetration. Clin Orthop Relat Res. 1989;245:57\u201368.","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"1489_CR104","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1097\/00007632-199520120-00008","volume":"20","author":"SD Glassman","year":"1995","unstructured":"Glassman SD, Dimar JR, Puno RM, Johnson JR, Shields CB, Linden RD. A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation. Spine (Phila Pa 1976). 1995;20(12):1375\u20139.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"1489_CR105","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1097\/00007632-199801150-00014","volume":"23","author":"NR Holland","year":"1998","unstructured":"Holland NR, Lukaczyk TA, Riley LH 3rd, Kostuik JP. Higher electrical stimulus intensities are required to activate chronically compressed nerve roots. Implications for intraoperative electromyographic pedicle screw testing. Spine (Phila Pa 1976). 1998;23(2):224\u20137. https:\/\/doi.org\/10.1097\/00007632-199801150-00014.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"1489_CR106","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1080\/1086508X.1997.11079176","volume":"37","author":"MR Isley","year":"1997","unstructured":"Isley MR, Pearlman RC, Wadsworth JS. Recent advances in intraoperative neuromonitoring of spinal cord function: Pedicle screw stimulation techniques. Am J Electroneurodiagn Technol. 1997;37(2):93\u2013126.","journal-title":"Am J Electroneurodiagn Technol"},{"issue":"2","key":"1489_CR107","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1080\/21646821.2012.11079851","volume":"52","author":"MR Isley","year":"2012","unstructured":"Isley MR, Zhang XF, Balzer JR, Leppanen RE. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels. Neurodiagn J. 2012;52(2):100\u201375.","journal-title":"Neurodiagn J"},{"issue":"14","key":"1489_CR108","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1097\/00007632-199507150-00006","volume":"20","author":"LG Lenke","year":"1995","unstructured":"Lenke LG, Padberg AM, Russo MH, Bridwell KH, Gelb DE. Triggered electromyographic threshold for accuracy of pedicle screw placement. An animal model and clinical correlation. Spine (Phila Pa 1976). 1995;20(14):1585\u201391. https:\/\/doi.org\/10.1097\/00007632-199507150-00006.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"1489_CR109","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1097\/00007632-199505000-00015","volume":"20","author":"J Maguire","year":"1995","unstructured":"Maguire J, Wallace S, Madiga R, Leppanen R, Draper V. Evaluation of intrapedicular screw position using intraoperative evoked electromyography. Spine (Phila Pa 1976). 1995;20(9):1068\u201374. https:\/\/doi.org\/10.1097\/00007632-199505000-00015.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"1489_CR110","doi-asserted-by":"publisher","first-page":"E387","DOI":"10.1097\/brs.0b013e31823b077b","volume":"37","author":"G de Blas","year":"2012","unstructured":"de Blas G, Barrios C, Regidor I, Montes E, Burgos J, Piz\u00e1-Vallespir G, Hevia E. Safe pedicle screw placement in thoracic scoliotic curves using t-EMG: stimulation threshold variability at concavity and convexity in apex segments. Spine (Phila Pa 1976). 2012;37(6):E387\u201395. https:\/\/doi.org\/10.1097\/brs.0b013e31823b077b.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR111","doi-asserted-by":"publisher","unstructured":"Lewis SJ, Lenke LG, Raynor B, Long J, Bridwell KH, Padberg A. Triggered electromyographic threshold for accuracy of thoracic pedicle screw placement in a porcine model. Spine (Phila Pa 1976), 2001. 26(22): pp. 2485-9; discussion 2490. https:\/\/doi.org\/10.1097\/00007632-200111150-00017","DOI":"10.1097\/00007632-200111150-00017"},{"issue":"2","key":"1489_CR112","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.spinee.2011.09.006","volume":"12","author":"E Montes","year":"2012","unstructured":"Montes E, De Blas G, Regidor I, Barrios C, Burgos J, Hevia E, Palanca JM, Correa C. Electromyographic thresholds after thoracic screw stimulation depend on the distance of the screw from the spinal cord and not on pedicle cortex integrity. Spine J. 2012;12(2):127\u201332. https:\/\/doi.org\/10.1016\/j.spinee.2011.09.006.","journal-title":"Spine J"},{"issue":"3","key":"1489_CR113","first-page":"E47","volume":"52","author":"JA Norton","year":"2009","unstructured":"Norton JA, Hedden DM. Monitoring placement of high thoracic pedicle screws by triggered electromyography of the intercostal muscles. Can J Surg. 2009;52(3):E47\u20138.","journal-title":"Can J Surg"},{"key":"1489_CR114","doi-asserted-by":"publisher","unstructured":"Raynor BL, Lenke LG, Kim Y, Hanson DS, Wilson-Holden TJ, Bridwell KH, Padberg AM. Can triggered electromyograph thresholds predict safe thoracic pedicle screw placement? Spine (Phila Pa 1976), 2002. 27(18): pp. 2030\u20135. https:\/\/doi.org\/10.1097\/00007632-200209150-00012","DOI":"10.1097\/00007632-200209150-00012"},{"issue":"10","key":"1489_CR115","doi-asserted-by":"publisher","first-page":"1620","DOI":"10.1007\/s00586-011-1800-z","volume":"20","author":"I Regidor","year":"2011","unstructured":"Regidor I, de Blas G, Barrios C, Burgos J, Montes E, Garc\u00eda-Urquiza S, Hevia E. Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement. Eur Spine J. 2011;20(10):1620\u20135. https:\/\/doi.org\/10.1007\/s00586-011-1800-z.","journal-title":"Eur Spine J"},{"issue":"7","key":"1489_CR116","doi-asserted-by":"publisher","first-page":"E194","DOI":"10.1097\/brs.0b013e3181696094","volume":"33","author":"JC Rodriguez-Olaverri","year":"2008","unstructured":"Rodriguez-Olaverri JC, Zimick NC, Merola A, De Blas G, Burgos J, Piza-Vallespir G, Hevia E, Vicente J, Sanper I, Domenech P, Regidor I. Using triggered electromyographic threshold in the intercostal muscles to evaluate the accuracy of upper thoracic pedicle screw placement (T3-T6). Spine (Phila Pa 1976). 2008;33(7):E194\u20137. https:\/\/doi.org\/10.1097\/brs.0b013e3181696094.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"1489_CR117","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1007\/s00586-010-1653-x","volume":"20","author":"AF Samdani","year":"2011","unstructured":"Samdani AF, Tantorski M, Cahill PJ, Ranade A, Koch S, Clements DH, Betz RR, Asghar J. Triggered electromyography for placement of thoracic pedicle screws: is it reliable? Eur Spine J. 2011;20(6):869\u201374. https:\/\/doi.org\/10.1007\/s00586-010-1653-x.","journal-title":"Eur Spine J"},{"issue":"6","key":"1489_CR118","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1097\/01.brs.0000049926.43292.93","volume":"28","author":"YB Shi","year":"2003","unstructured":"Shi YB, Binette M, Martin WH, Pearson JM, Hart RA. Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement. Spine (Phila Pa 1976). 2003;28(6):595\u2013601. https:\/\/doi.org\/10.1097\/01.brs.0000049926.43292.93.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"1","key":"1489_CR119","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1080\/1086508x.2010.11079752","volume":"50","author":"JW Silverstein","year":"2010","unstructured":"Silverstein JW, Mermelstein LE. Utilization of paraspinal muscles for triggered EMG during thoracic pedicle screw placement. Am J Electroneurodiagnostic Technol. 2010;50(1):37\u201349. https:\/\/doi.org\/10.1080\/1086508x.2010.11079752.","journal-title":"Am J Electroneurodiagnostic Technol"},{"issue":"6","key":"1489_CR120","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1097\/01.bsd.0000173315.06025.c6","volume":"18","author":"M Djurasovic","year":"2005","unstructured":"Djurasovic M, Dimar JR 2nd, Glassman SD, Edmonds HL, Carreon LY. A prospective analysis of intraoperative electromyographic monitoring of posterior cervical screw fixation. J Spinal Disord Tech. 2005;18(6):515\u20138. https:\/\/doi.org\/10.1097\/01.bsd.0000173315.06025.c6.","journal-title":"J Spinal Disord Tech"},{"key":"1489_CR121","doi-asserted-by":"publisher","unstructured":"Holdefer RN, Heffez DS, Cohen BA. Utility of evoked EMG monitoring to improve bone screw placements in the cervical spine. J Spinal Disord Tech. 2013;26(5):p. E163-9. https:\/\/doi.org\/10.1097\/bsd.0b013e31828871a1.\u00a0","DOI":"10.1097\/bsd.0b013e31828871a1"},{"issue":"3","key":"1489_CR122","doi-asserted-by":"publisher","first-page":"346","DOI":"10.3171\/2016.8.spine16580","volume":"26","author":"B Wilson","year":"2017","unstructured":"Wilson B, Curtis E, Hirshman B, Oygar A, Chen K, Gabel BC, Vaida F, Allison DW, Ciacci JD. Lateral mass screw stimulation thresholds in posterior cervical instrumentation surgery: a predictor of medial deviation. J Neurosurg Spine. 2017;26(3):346\u201352. https:\/\/doi.org\/10.3171\/2016.8.spine16580.","journal-title":"J Neurosurg Spine"},{"issue":"12","key":"1489_CR123","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1097\/00007632-200106150-00008","volume":"26","author":"T Danesh-Clough","year":"2001","unstructured":"Danesh-Clough T, Taylor P, Hodgson B, Walton M. The use of evoked EMG in detecting misplaced thoracolumbar pedicle screws. Spine (Phila Pa 1976). 2001;26(12):1313\u20136. https:\/\/doi.org\/10.1097\/00007632-200106150-00008.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"24","key":"1489_CR124","doi-asserted-by":"publisher","first-page":"2673","DOI":"10.1097\/brs.0b013e31815a524f","volume":"32","author":"BL Raynor","year":"2007","unstructured":"Raynor BL, Lenke LG, Bridwell KH, Taylor BA, Padberg AM. Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: analysis of 4857 screws. Spine (Phila Pa 1976). 2007;32(24):2673\u20138. https:\/\/doi.org\/10.1097\/brs.0b013e31815a524f.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR125","doi-asserted-by":"publisher","unstructured":"Donohue ML, Murtagh-Schaffer C, Basta J, Moquin RR, Bashir A, Calancie B. Pulse-train stimulation for detecting medial malpositioning of thoracic pedicle screws. Spine (Phila Pa 1976). 2008;33(12):E378-85. https:\/\/doi.org\/10.1097\/brs.0b013e31817343c1.\u00a0","DOI":"10.1097\/brs.0b013e31817343c1"},{"issue":"6","key":"1489_CR126","doi-asserted-by":"publisher","first-page":"675","DOI":"10.3171\/2014.2.spine13648","volume":"20","author":"B Calancie","year":"2014","unstructured":"Calancie B, Donohue ML, Harris CB, Canute GW, Singla A, Wilcoxen KG, Moquin RR. Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 1. Methods and alarm criteria. J Neurosurg Spine. 2014;20(6):675\u201391. https:\/\/doi.org\/10.3171\/2014.2.spine13648.","journal-title":"J Neurosurg Spine"},{"issue":"6","key":"1489_CR127","doi-asserted-by":"publisher","first-page":"692","DOI":"10.3171\/2014.2.spine13649","volume":"20","author":"B Calancie","year":"2014","unstructured":"Calancie B, Donohue ML, Moquin RR. Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 2. The role of feedback. J Neurosurg Spine. 2014;20(6):692\u2013704. https:\/\/doi.org\/10.3171\/2014.2.spine13649.","journal-title":"J Neurosurg Spine"},{"key":"1489_CR128","doi-asserted-by":"publisher","first-page":"107207","DOI":"10.1016\/j.clineuro.2022.107207","volume":"215","author":"E Montes","year":"2022","unstructured":"Montes E, de Blas G, Barrios C, Mariscal G, Burgos J, Regidor I, Hevia E. Pulse-train versus single-pulse t-EMG stimulation for intraoperative neurophysiologic monitoring of thoracic pedicle screws in adolescent idiopathic scoliosis. Clin Neurol Neurosurg. 2022;215:107207. https:\/\/doi.org\/10.1016\/j.clineuro.2022.107207.","journal-title":"Clin Neurol Neurosurg"},{"issue":"13","key":"1489_CR129","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1097\/00007632-200207010-00014","volume":"27","author":"B Bose","year":"2002","unstructured":"Bose B, Wierzbowski LR, Sestokas AK. Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery. Spine (Phila Pa 1976). 2002;27(13):1444\u201350. https:\/\/doi.org\/10.1097\/00007632-200207010-00014.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"1489_CR130","doi-asserted-by":"publisher","first-page":"2019","DOI":"10.1016\/j.clinph.2014.11.026","volume":"126","author":"CH Lee","year":"2015","unstructured":"Lee CH, Kim HW, Kim HR, Lee CY, Kim JH, Sala F. Can triggered electromyography thresholds assure accurate pedicle screw placements? A systematic review and meta-analysis of diagnostic test accuracy. Clin Neurophysiol. 2015;126(10):2019\u201325. https:\/\/doi.org\/10.1016\/j.clinph.2014.11.026.","journal-title":"Clin Neurophysiol"},{"issue":"2","key":"1489_CR131","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3171\/2011.3.spine101","volume":"15","author":"SL Parker","year":"2011","unstructured":"Parker SL, Amin AG, Farber SH, McGirt MJ, Sciubba DM, Wolinsky JP, Bydon A, Gokaslan ZL, Witham TF. Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: analysis of 2450 consecutively placed screws. J Neurosurg Spine. 2011;15(2):130\u20135. https:\/\/doi.org\/10.3171\/2011.3.spine101.","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"1489_CR132","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1097\/wnp.0b013e31824cece6","volume":"29","author":"GS Nichols","year":"2012","unstructured":"Nichols GS, Manafov E. Utility of electromyography for nerve root monitoring during spinal surgery. J Clin Neurophysiol. 2012;29(2):140\u20138. https:\/\/doi.org\/10.1097\/wnp.0b013e31824cece6.","journal-title":"J Clin Neurophysiol"},{"issue":"6","key":"1489_CR133","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1097\/wnp.0b013e3182768075","volume":"29","author":"SA Skinner","year":"2012","unstructured":"Skinner SA, Rippe DM. Threshold testing of lumbosacral pedicle screws: a reappraisal. J Clin Neurophysiol. 2012;29(6):493\u2013501. https:\/\/doi.org\/10.1097\/wnp.0b013e3182768075.","journal-title":"J Clin Neurophysiol"},{"issue":"2","key":"1489_CR134","doi-asserted-by":"publisher","first-page":"E139","DOI":"10.1097\/brs.0000000000003727","volume":"46","author":"SR Melachuri","year":"2021","unstructured":"Melachuri SR, Melachuri MK, Anetakis K, Crammond DJ, Balzer JR, Thirumala PD. Diagnostic accuracy of thresholds less than or equal to 8\u00a0mA in pedicle screw testing during lumbar spine procedures to predict new postoperative lower extremity neurological deficits. Spine (Phila Pa 1976). 2021;46(2):E139\u201345. https:\/\/doi.org\/10.1097\/brs.0000000000003727.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR135","doi-asserted-by":"publisher","first-page":"e250","DOI":"10.1016\/j.wneu.2021.04.022","volume":"151","author":"SR Melachuri","year":"2021","unstructured":"Melachuri SR, Melachuri MK, Mina A, Anetakis K, Crammond DJ, Balzer JR, Shandal V, Thirumala PD. Optimal low pedicle screw stimulation threshold to predict new postoperative lower-extremity neurologic deficits during lumbar spinal fusions. World Neurosurg. 2021;151:e250\u20136. https:\/\/doi.org\/10.1016\/j.wneu.2021.04.022.","journal-title":"World Neurosurg"},{"issue":"12","key":"1489_CR136","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.1016\/j.spinee.2022.07.090","volume":"22","author":"M Amick","year":"2022","unstructured":"Amick M, Ottesen TD, O\u2019Marr J, Frenkel MY, Callahan B, Grauer JN. Effects of anode position on pedicle screw testing during lumbosacral spinal fusion surgery. Spine J. 2022;22(12):2000\u20135. https:\/\/doi.org\/10.1016\/j.spinee.2022.07.090.","journal-title":"Spine J"},{"key":"1489_CR137","doi-asserted-by":"crossref","unstructured":"Toleikis JR, Deletis V, Shils JL. 2002, Academic: San Diego. 231\u201364.","DOI":"10.1016\/B978-012209036-3\/50013-5"},{"issue":"14","key":"1489_CR138","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1097\/00007632-200207150-00018","volume":"27","author":"DG Anderson","year":"2002","unstructured":"Anderson DG, Wierzbowski LR, Schwartz DM, Hilibrand AS, Vaccaro AR, Albert TJ. Pedicle screws with high electrical resistance: a potential source of error with stimulus-evoked EMG. Spine (Phila Pa 1976). 2002;27(14):1577\u201381. https:\/\/doi.org\/10.1097\/00007632-200207150-00018.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"5","key":"1489_CR139","doi-asserted-by":"publisher","first-page":"600","DOI":"10.3171\/2010.5.spine09536","volume":"13","author":"MY Wang","year":"2010","unstructured":"Wang MY, Pineiro G, Mummaneni PV. Stimulus-evoked electromyography testing of percutaneous pedicle screws for the detection of pedicle breaches: a clinical study of 409 screws in 93 patients. J Neurosurg Spine. 2010;13(5):600\u20135. https:\/\/doi.org\/10.3171\/2010.5.spine09536.","journal-title":"J Neurosurg Spine"},{"issue":"2","key":"1489_CR140","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1097\/wnp.0000000000000040","volume":"31","author":"TT Davis","year":"2014","unstructured":"Davis TT, Tadlock S, Bernbeck J, Fung DA, Molinares DM. Can triggered electromyography be used to evaluate pedicle screw placement in hydroxyapatite-coated screws: an electrical examination. J Clin Neurophysiol. 2014;31(2):138\u201342. https:\/\/doi.org\/10.1097\/wnp.0000000000000040.","journal-title":"J Clin Neurophysiol"},{"issue":"6","key":"1489_CR141","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1097\/wnp.0b013e3182767aac","volume":"29","author":"ML Donohue","year":"2012","unstructured":"Donohue ML, Swaminathan V, Gilbert JL, Fox CW, Smale J, Moquin RR, Calancie B. Intraoperative neuromonitoring: can the results of direct stimulation of titanium-alloy pedicle screws in the thoracic spine be trusted? J Clin Neurophysiol. 2012;29(6):502\u20138. https:\/\/doi.org\/10.1097\/wnp.0b013e3182767aac.","journal-title":"J Clin Neurophysiol"},{"key":"1489_CR142","doi-asserted-by":"publisher","unstructured":"Ozgur BM, Aryan HE, Pimenta L, Taylor WR. Extreme Lateral Interbody Fusion (XLIF): a novel surgical technique for anterior lumbar interbody fusion. Spine J. 2006;6(4):435\u2009\u2013\u200943. https:\/\/doi.org\/10.1016\/j.spinee.2005.08.012.\u00a0","DOI":"10.1016\/j.spinee.2005.08.012"},{"issue":"3","key":"1489_CR143","doi-asserted-by":"publisher","first-page":"280","DOI":"10.3171\/2011.4.spine1127","volume":"15","author":"JK Houten","year":"2011","unstructured":"Houten JK, Alexandre LC, Nasser R, Wollowick AL. Nerve injury during the transpsoas approach for lumbar fusion. J Neurosurg Spine. 2011;15(3):280\u20134. https:\/\/doi.org\/10.3171\/2011.4.spine1127.","journal-title":"J Neurosurg Spine"},{"issue":"4","key":"1489_CR144","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1080\/1086508X.2010.11079786","volume":"50","author":"FR Jahangiri","year":"2010","unstructured":"Jahangiri FR, Sherman JH, Holmberg A, Louis R, Elias J, Vega-Bermudez F. Protecting the genitofemoral nerve during direct\/extreme lateral interbody fusion (DLIF\/XLIF) procedures. Am J Electroneurodiagnostic Technol. 2010;50(4):321\u201335.","journal-title":"Am J Electroneurodiagnostic Technol"},{"issue":"Suppl 3","key":"1489_CR145","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1007\/s00586-015-3871-8","volume":"24","author":"JS Uribe","year":"2015","unstructured":"Uribe JS, Isaacs RE, Youssef JA, Khajavi K, Balzer JR, Kanter AS, K\u00fcelling FA, Peterson MD, SOLAS Degenerative Study Group. Can triggered electromyography monitoring throughout retraction predict postoperative symptomatic neuropraxia after XLIF? Results from a prospective multicenter trial. Eur Spine J. 2015;24(Suppl 3):378\u201385. https:\/\/doi.org\/10.1007\/s00586-015-3871-8.","journal-title":"Eur Spine J"},{"issue":"5","key":"1489_CR146","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1007\/s10877-015-9713-8","volume":"29","author":"K Chaudhary","year":"2015","unstructured":"Chaudhary K, Speights K, McGuire K, White AP. Trans-cranial motor evoked potential detection of femoral nerve injury in trans-psoas lateral lumbar interbody fusion. J Clin Monit Comput. 2015;29(5):549\u201354. https:\/\/doi.org\/10.1007\/s10877-015-9713-8.","journal-title":"J Clin Monit Comput"},{"issue":"10","key":"1489_CR147","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1016\/j.spinee.2018.02.024","volume":"18","author":"MR Riley","year":"2018","unstructured":"Riley MR, Doan AT, Vogel RW, Aguirre AO, Pieri KS, Scheid EH. Use of motor evoked potentials during lateral lumbar interbody fusion reduces postoperative deficits. Spine J. 2018;18(10):1763\u201378. https:\/\/doi.org\/10.1016\/j.spinee.2018.02.024.","journal-title":"Spine J"},{"issue":"1","key":"1489_CR148","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1080\/21646821.2015.1012456","volume":"55","author":"J Block","year":"2015","unstructured":"Block J, Silverstein JW, Ball HT, Mermelstein LE, DeWal HS, Madhok R, Basra SK, Goldstein MJ. Motor evoked potentials for femoral nerve protection in transpsoas lateral access surgery of the spine. Neurodiagn J. 2015;55(1):36\u201345. https:\/\/doi.org\/10.1080\/21646821.2015.1012456.","journal-title":"Neurodiagn J"},{"issue":"5","key":"1489_CR149","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1177\/2192568220922979","volume":"11","author":"N Jain","year":"2021","unstructured":"Jain N, Alluri R, Phan K, Yanni D, Alvarez A, Guillen H, Mnatsakanyan L, Bederman SS. Saphenous nerve somatosensory-evoked potentials monitoring during lateral interbody fusion. Global Spine J. 2021;11(5):722\u20136. https:\/\/doi.org\/10.1177\/2192568220922979.","journal-title":"Global Spine J"},{"issue":"15","key":"1489_CR150","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1097\/brs.0000000000000357","volume":"39","author":"J Silverstein","year":"2014","unstructured":"Silverstein J, Mermelstein L, DeWal H, Basra S. Saphenous nerve somatosensory evoked potentials: a novel technique to monitor the femoral nerve during transpsoas lumbar lateral interbody fusion. Spine (Phila Pa 1976). 2014;39(15):1254\u201360. https:\/\/doi.org\/10.1097\/brs.0000000000000357.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"1489_CR151","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.spinee.2021.07.017","volume":"22","author":"JW Silverstein","year":"2022","unstructured":"Silverstein JW, Block J, Smith ML, et al. Femoral nerve neuromonitoring for lateral lumbar interbody fusion surgery. Spine J. 2022;22(2):296\u2013304. https:\/\/doi.org\/10.1016\/j.spinee.2021.07.017.","journal-title":"Spine J"},{"key":"1489_CR152","doi-asserted-by":"publisher","unstructured":"Tohmeh AG, Rodgers WB, Peterson MD. Dynamically evoked, discrete-threshold electromyography in the extreme lateral interbody fusion approach. J Neurosurg Spine. 2011;14(1):31\u2009\u2013\u20097. https:\/\/doi.org\/10.3171\/2010.9.spine09871.\u00a0","DOI":"10.3171\/2010.9.spine09871"},{"key":"1489_CR153","doi-asserted-by":"publisher","unstructured":"Falowski SM, Celii A, Sestokas AK, Schwartz DM, Matsumoto C, Sharan A. Awake vs. asleep placement of spinal cord stimulators: a cohort analysis of complications associated with placement. Neuromodulation, 2011. 14(2): pp. 130-4; discussion 134-5. https:\/\/doi.org\/10.1111\/j.1525-1403.2010.00319.x","DOI":"10.1111\/j.1525-1403.2010.00319.x"},{"issue":"6","key":"1489_CR154","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1111\/j.1525-1403.2012.00475.x","volume":"15","author":"EL Air","year":"2012","unstructured":"Air EL, Toczyl GR, Mandybur GT. Electrophysiologic monitoring for placement of laminectomy leads for spinal cord stimulation under general anesthesia. Neuromodulation. 2012;15(6):573\u20139. https:\/\/doi.org\/10.1111\/j.1525-1403.2012.00475.x. discussion 579\u2009\u2013\u200980.","journal-title":"Neuromodulation"},{"issue":"6","key":"1489_CR155","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1111\/ner.12590","volume":"20","author":"C Collison","year":"2017","unstructured":"Collison C, Prusik J, Paniccioli S, Briotte M, Grey R, Feustel P, Pilitsis JG. Prospective study of the use of intraoperative neuromonitoring in determining post-operative energy requirements and physiologic midline in spinal cord stimulation. Neuromodulation. 2017;20(6):575\u201381. https:\/\/doi.org\/10.1111\/ner.12590.","journal-title":"Neuromodulation"},{"key":"1489_CR156","doi-asserted-by":"publisher","unstructured":"Mammis A, Mogilner AY. The use of intraoperative electrophysiology for the placement of spinal cord stimulator paddle leads under general anesthesia. Neurosurgery. 2012;230\u20136. https:\/\/doi.org\/10.1227\/neu.0b013e318232ff29. 70(2 Suppl Operative).","DOI":"10.1227\/neu.0b013e318232ff29"},{"issue":"5","key":"1489_CR157","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1159\/000437388","volume":"93","author":"SG Roth","year":"2015","unstructured":"Roth SG, Lange S, Haller J, De La Cruz P, Kumar V, Wilock M, Paniccioli S, Briotte M, Pilitsis JG. A prospective study of the intra- and postoperative efficacy of intraoperative neuromonitoring in spinal cord stimulation. Stereotact Funct Neurosurg. 2015;93(5):348\u201354. https:\/\/doi.org\/10.1159\/000437388.","journal-title":"Stereotact Funct Neurosurg"},{"key":"1489_CR158","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.wneu.2016.12.077","volume":"100","author":"N Schoen","year":"2017","unstructured":"Schoen N, Chieng LO, Madhavan K, Jermakowicz WJ, Vanni S. The use of intraoperative electromyogram during spinal cord stimulator placement surgery: A case series. World Neurosurg. 2017;100:74\u201384. https:\/\/doi.org\/10.1016\/j.wneu.2016.12.077.","journal-title":"World Neurosurg"},{"key":"1489_CR159","doi-asserted-by":"publisher","unstructured":"Shils JL, Arle JE. Intraoperative neurophysiologic methods for spinal cord stimulator placement under general anesthesia. Neuromodulation. 2012;15(6):560\u2009\u2013\u200971; discussion 571-2. https:\/\/doi.org\/10.1111\/j.1525-1403.2012.00460.x.\u00a0","DOI":"10.1111\/j.1525-1403.2012.00460.x"},{"key":"1489_CR160","doi-asserted-by":"publisher","unstructured":"Tamkus AA, Scott AF, Khan FR. Neurophysiological monitoring during spinal cord stimulator placement surgery. Neuromodulation, 2015. 18(6): pp. 460-4; discussion 464. https:\/\/doi.org\/10.1111\/ner.12273","DOI":"10.1111\/ner.12273"},{"issue":"4","key":"1489_CR161","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1111\/ner.13286","volume":"24","author":"SM Falowski","year":"2021","unstructured":"Falowski SM, Deer T, Tubic G, Mehta P. Multicenter retrospective analysis of dorsal root ganglion stimulator placement using intraoperative neuromonitoring in asleep patients during early periods of adoption. Neuromodulation. 2021;24(4):753\u20137. https:\/\/doi.org\/10.1111\/ner.13286.","journal-title":"Neuromodulation"},{"issue":"6","key":"1489_CR162","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1093\/ons\/opx172","volume":"14","author":"SM Falowski","year":"2018","unstructured":"Falowski SM, Dianna A. A prospective analysis of neuromonitoring for confirmation of lead placement in dorsal root ganglion stimulation. Oper Neurosurg. 2018;14(6):654\u201360. https:\/\/doi.org\/10.1093\/ons\/opx172.","journal-title":"Oper Neurosurg"},{"key":"1489_CR163","doi-asserted-by":"publisher","unstructured":"Kurian RJ, Falowski S. Spinal cord stimulation: Neuromodulation for intraoperative neuromonitoring personnel. Neurodiagn J. 2025;1\u201323. https:\/\/doi.org\/10.1080\/21646821.2025.2490307.","DOI":"10.1080\/21646821.2025.2490307"},{"issue":"2","key":"1489_CR164","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1007\/s00381-020-04866-2","volume":"37","author":"S Eibach","year":"2021","unstructured":"Eibach S, Moes G, Hou YJ, Zovickian J, Pang D. New surgical paradigm for open neural tube defects. Childs Nerv Syst. 2021;37(2):529\u201338. https:\/\/doi.org\/10.1007\/s00381-020-04866-2.","journal-title":"Childs Nerv Syst"},{"issue":"6","key":"1489_CR165","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1007\/s00381-019-04129-9","volume":"35","author":"G Fekete","year":"2019","unstructured":"Fekete G, Bogn\u00e1r L, Nov\u00e1k L. Surgical treatment of tethered cord syndrome-comparing the results of surgeries with and without electrophysiological monitoring. Childs Nerv Syst. 2019;35(6):979\u201384. https:\/\/doi.org\/10.1007\/s00381-019-04129-9.","journal-title":"Childs Nerv Syst"},{"key":"1489_CR166","doi-asserted-by":"publisher","unstructured":"Valentini LG, Visintini S, Mendola C, Casali C, Bono R, Scaioli W, Solero CL. The role of intraoperative electromyographic monitoring in lumbosacral lipomas. Neurosurgery. 2005;56(2 Suppl). https:\/\/doi.org\/10.1227\/01.neu.0000156783.03809.8a. 315\u2009\u2013\u200923; discussion 315\u2009\u2013\u200923.","DOI":"10.1227\/01.neu.0000156783.03809.8a"},{"issue":"6","key":"1489_CR167","doi-asserted-by":"publisher","first-page":"e4867","DOI":"10.7759\/cureus.4867","volume":"11","author":"FR Jahangiri","year":"2019","unstructured":"Jahangiri FR, Asdi RA, Tarasiewicz I, Azzubi M. Intraoperative triggered electromyography recordings from the external urethral sphincter muscles during spine surgeries. Cureus. 2019;11(6):e4867. https:\/\/doi.org\/10.7759\/cureus.4867.","journal-title":"Cureus"},{"key":"1489_CR168","doi-asserted-by":"publisher","unstructured":"Qui\u00f1ones-Hinojosa A, Gadkary CA, Gulati M, von Koch CS, Lyon R, Weinstein PR, Yingling CD. Neurophysiological monitoring for safe surgical tethered cord syndrome release in adults. Surg Neurol. 2004;62(2). https:\/\/doi.org\/10.1016\/j.surneu.2003.11.025. 127\u2009\u2013\u200933; discussion 133-5.","DOI":"10.1016\/j.surneu.2003.11.025"},{"key":"1489_CR169","doi-asserted-by":"publisher","unstructured":"Fasano VA, Barolat-Romana G, Zeme S, Squazzi A. Electrophysiological assessment of spinal circuits in spasticity by direct dorsal root stimulation. Neurosurgery. 1979;4(2). https:\/\/doi.org\/10.1227\/00006123-197902000-00007. 146\u2009\u2013\u200951.","DOI":"10.1227\/00006123-197902000-00007"},{"key":"1489_CR170","doi-asserted-by":"publisher","unstructured":"Peacock WJ, Arens LJ, Berman B. Cerebral palsy spasticity. Selective posterior rhizotomy. Pediatr Neurosci. 1987;13(2). https:\/\/doi.org\/10.1159\/000120302. 61\u2009\u2013\u20096.","DOI":"10.1159\/000120302"},{"issue":"6","key":"1489_CR171","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/0924-980x(95)00128-8","volume":"97","author":"LA Staudt","year":"1995","unstructured":"Staudt LA, Nuwer MR, Peacock WJ. Intraoperative monitoring during selective posterior rhizotomy: technique and patient outcome. Electroencephalogr Clin Neurophysiol. 1995;97(6):296\u2013309. https:\/\/doi.org\/10.1016\/0924-980x(95)00128-8.","journal-title":"Electroencephalogr Clin Neurophysiol"},{"issue":"9","key":"1489_CR172","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.1007\/s00381-009-0908-5","volume":"25","author":"P Steinbok","year":"2009","unstructured":"Steinbok P, Tidemann AJ, Miller S, Mortenson P, Bowen-Roberts T. Electrophysiologically guided versus non-electrophysiologically guided selective dorsal rhizotomy for spastic cerebral palsy: a comparison of outcomes. Childs Nerv Syst. 2009;25(9):1091\u20136. https:\/\/doi.org\/10.1007\/s00381-009-0908-5.","journal-title":"Childs Nerv Syst"},{"issue":"1\u20134","key":"1489_CR173","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1159\/000098964","volume":"58","author":"AL Albright","year":"1992","unstructured":"Albright AL. Neurosurgical treatment of spasticity: selective posterior rhizotomy and intrathecal baclofen. Stereotact Funct Neurosurg. 1992;58(1\u20134):3\u201313. https:\/\/doi.org\/10.1159\/000098964.","journal-title":"Stereotact Funct Neurosurg"},{"issue":"1","key":"1489_CR174","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1080\/1086508X.1997.11079171","volume":"37","author":"RD Rose","year":"1997","unstructured":"Rose RD. Selective posterior rhizotomy: A guide for intraoperative neurophysiography. Am J Electroneurodiagn Technol. 1997;37(1):27\u201350.","journal-title":"Am J Electroneurodiagn Technol"},{"key":"1489_CR175","doi-asserted-by":"publisher","unstructured":"Park TS, Gaffney PE, Kaufman BA, Molleston MC. Selective lumbosacral dorsal rhizotomy immediately caudal to the conus medullaris for cerebral palsy spasticity. Neurosurgery. 1993;33(5). https:\/\/doi.org\/10.1227\/00006123-199311000-00026. 929\u2009\u2013\u200933; discussion 933-4.","DOI":"10.1227\/00006123-199311000-00026"},{"key":"1489_CR176","doi-asserted-by":"publisher","unstructured":"Crum BA, Strommen JA. Peripheral nerve stimulation and monitoring during operative procedures. Muscle Nerve. 2007;35(2). https:\/\/doi.org\/10.1002\/mus.20707. 159\u2009\u2013\u200970.","DOI":"10.1002\/mus.20707"},{"key":"1489_CR177","doi-asserted-by":"publisher","unstructured":"Grant GA, Goodkin R, Kliot M. Evaluation and surgical management of peripheral nerve problems. Neurosurgery. 1999;44(4). https:\/\/doi.org\/10.1097\/00006123-199904000-00077. 825\u2009\u2013\u200939; discussion 839\u2009\u2013\u200940.","DOI":"10.1097\/00006123-199904000-00077"},{"issue":"1","key":"1489_CR178","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1080\/21646821.2022.2034342","volume":"62","author":"A Rosenberg","year":"2022","unstructured":"Rosenberg A, Pruitt R, Saba S, Silverstein JW, D\u2019Amico RS. Isolating the superficial peroneal nerve motor branch to the peroneus longus muscle with concentric stimulation during diagnostic motor nerve biopsy. Neurodiagn J. 2022;62(1):26\u201336. https:\/\/doi.org\/10.1080\/21646821.2022.2034342.","journal-title":"Neurodiagn J"},{"key":"1489_CR179","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/b978-0-12-819826-1.00022-3","volume":"186","author":"JA Strommen","year":"2022","unstructured":"Strommen JA, Skinner S, Crum BA. Neurophysiology during peripheral nerve surgery. Handb Clin Neurol. 2022;186:295\u2013318. https:\/\/doi.org\/10.1016\/b978-0-12-819826-1.00022-3.","journal-title":"Handb Clin Neurol"},{"issue":"4","key":"1489_CR180","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/j.jhsa.2022.11.022","volume":"48","author":"NA Zelenski","year":"2023","unstructured":"Zelenski NA, Oishi T, Shin AY. Intraoperative neuromonitoring for peripheral nerve surgery. J Hand Surg Am. 2023;48(4):396\u2013401. https:\/\/doi.org\/10.1016\/j.jhsa.2022.11.022.","journal-title":"J Hand Surg Am"},{"key":"1489_CR181","doi-asserted-by":"publisher","unstructured":"Oberle J, Antoniadis G, Kast E, Richter HP. Evaluation of traumatic cervical nerve root injuries by intraoperative evoked potentials. Neurosurgery, 2002. 51(5): pp. 1182-8; discussion 1188-90. https:\/\/doi.org\/10.1097\/00006123-200211000-00012","DOI":"10.1097\/00006123-200211000-00012"},{"issue":"3","key":"1489_CR182","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1007\/bf01844758","volume":"139","author":"J Oberle","year":"1997","unstructured":"Oberle J, Antoniadis G, Rath SA, Richter HP. Intra-operative electrophysiological diagnosis of spinal root avulsion during surgical repair of brachial plexus stretch injuries. Acta Neurochir (Wien). 1997;139(3):238\u20139. https:\/\/doi.org\/10.1007\/bf01844758.","journal-title":"Acta Neurochir (Wien)"},{"key":"1489_CR183","unstructured":"Arapovi\u0107 D, Rogi\u0107 M, Deletis V. Posterior root muscle reflex: eliciting H-reflex by percutaneous stimulation of cauda equine, in Second Congress of the International Society of Intraoperative Neurophysiology. 2009: Dubrovnik, Croatia."},{"key":"1489_CR184","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/B978-0-12-815000-9.00018-6","volume-title":"Neurophysiology in Neurosurgery","author":"K Minassian","year":"2020","unstructured":"Minassian K, Freundl B, Hofstoetter US. The posterior root-muscle reflex. In: Deletis V, Shils JL, Sala F, Seidel K, editors. Neurophysiology in Neurosurgery. Academic; 2020. pp. 239\u201353."},{"issue":"3","key":"1489_CR185","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1002\/mus.20700","volume":"35","author":"K Minassian","year":"2007","unstructured":"Minassian K, Persy I, Rattay F, Dimitrijevic MR, Hofer C, Kern H. Posterior root-muscle reflexes elicited by transcutaneous stimulation of the human lumbosacral cord. Muscle Nerve. 2007;35(3):327\u201336. https:\/\/doi.org\/10.1002\/mus.20700.","journal-title":"Muscle Nerve"},{"key":"1489_CR186","doi-asserted-by":"publisher","unstructured":"Maertens de Noordhout A, Rothwell JC, Thompson PD, Day BL, Marsden CD. Percutaneous electrical stimulation of lumbosacral roots in man. J Neurol Neurosurg Psychiatry. 1988;51(2). https:\/\/doi.org\/10.1136\/jnnp.51.2.174. 174\u2009\u2013\u200981.","DOI":"10.1136\/jnnp.51.2.174"},{"issue":"5","key":"1489_CR187","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1002\/(sici)1097-4598","volume":"19","author":"W Troni","year":"1996","unstructured":"Troni W, Bianco C, Coletti Moja M, Dotta M. Improved methodology for lumbosacral nerve root stimulation. Muscle Nerve. 1996;19(5):595\u2013604. https:\/\/doi.org\/10.1002\/(sici)1097-4598. )19:5%3C595::aid-mus7%3E3.0.co;2-6.","journal-title":"Muscle Nerve"},{"issue":"10","key":"1489_CR188","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1016\/j.clinph.2011.03.002","volume":"122","author":"W Troni","year":"2011","unstructured":"Troni W, Di Sapio A, Berra E, Duca S, Merola A, Sperli F, Bertolotto A. A methodological reappraisal of non invasive high voltage electrical stimulation of lumbosacral nerve roots. Clin Neurophysiol. 2011;122(10):2071\u201380. https:\/\/doi.org\/10.1016\/j.clinph.2011.03.002.","journal-title":"Clin Neurophysiol"},{"key":"1489_CR189","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.clinph.2023.06.023","volume":"154","author":"L Guo","year":"2023","unstructured":"Guo L, Boakye E, Sadleir RJ, Holdefer RN. Transcranial MEP threshold voltages and current densities simulated with finite element modelling. Clin Neurophysiol. 2023;154:1\u201311. https:\/\/doi.org\/10.1016\/j.clinph.2023.06.023.","journal-title":"Clin Neurophysiol"},{"issue":"6","key":"1489_CR190","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1016\/j.clinph.2006.02.020","volume":"117","author":"RN Holdefer","year":"2006","unstructured":"Holdefer RN, Sadleir R, Russell MJ. Predicted current densities in the brain during transcranial electrical stimulation. Clin Neurophysiol. 2006;117(6):1388\u201397. https:\/\/doi.org\/10.1016\/j.clinph.2006.02.020.","journal-title":"Clin Neurophysiol"},{"issue":"4","key":"1489_CR191","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.clinph.2012.10.009","volume":"124","author":"W Troni","year":"2013","unstructured":"Troni W, Benech CA, Perez R, Tealdi S, Berardino M, Benech F. Non-invasive high voltage electrical stimulation as a monitoring tool of nerve root function in lumbosacral surgery. Clin Neurophysiol. 2013;124(4):809\u201318. https:\/\/doi.org\/10.1016\/j.clinph.2012.10.009.","journal-title":"Clin Neurophysiol"},{"issue":"9","key":"1489_CR192","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1016\/j.spinee.2024.04.029","volume":"24","author":"DW Allison","year":"2024","unstructured":"Allison DW, Verma A, Holman PJ, et al. Transabdominal motor evoked potential neuromonitoring of lumbosacral spine surgery. Spine J. 2024;24(9):1660\u201370. https:\/\/doi.org\/10.1016\/j.spinee.2024.04.029.","journal-title":"Spine J"},{"issue":"5","key":"1489_CR193","doi-asserted-by":"publisher","first-page":"e16","DOI":"10.1016\/j.clinph.2013.12.012","volume":"125","author":"A Climent","year":"2014","unstructured":"Climent A, Fernandez-Conejero I, Coscujuela A, Ribas M, Ulkatan S, Deletis V. Multimodal intraoperative evoked potential monitoring (IOM) for hip surgery. Clin Neurophysiol. 2014;125(5):e16. https:\/\/doi.org\/10.1016\/j.clinph.2013.12.012.","journal-title":"Clin Neurophysiol"},{"issue":"3","key":"1489_CR194","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1080\/21646821.2016.1202723","volume":"56","author":"RM Mandeville","year":"2016","unstructured":"Mandeville RM, Brown JM, Gertsch JH, Allison DW. Use of posterior root-muscle reflexes in peripheral nerve surgery: A case report. Neurodiagn J. 2016;56(3):178\u201385. https:\/\/doi.org\/10.1080\/21646821.2016.1202723.","journal-title":"Neurodiagn J"},{"key":"1489_CR195","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/B978-0-12-815000-9.00031-9","volume-title":"Neurophysiology in Neurosurgery","author":"A de Climent","year":"2020","unstructured":"Climent A, de Meo F, Ribas M, Coscujuela A, Agullo JL, Ulkatan S, Deletis V. An intraoperative neurophysiological monitoring method for testing functional integrity of the low extremity peripheral nerves during hip surgery. In: Deletis V, Shils JL, Sala F, Seidel K, editors. Neurophysiology in Neurosurgery. Academic; 2020. pp. 431\u201340."},{"issue":"5","key":"1489_CR196","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1097\/wnp.0000000000000490","volume":"35","author":"AA Gonzalez","year":"2018","unstructured":"Gonzalez AA, Cheongsiatmoy J, Shilian P, Parikh P. Comparison of transcranial motor evoked potential amplitude responses between intramuscular and subcutaneous needles in proximal thigh muscle. J Clin Neurophysiol. 2018;35(5):431\u20135. https:\/\/doi.org\/10.1097\/wnp.0000000000000490.","journal-title":"J Clin Neurophysiol"},{"key":"1489_CR197","doi-asserted-by":"publisher","unstructured":"Patel A, McDermott M, Rogers M, Jakoi A, Thomas JA. P34. Transabdominal Muscle Action Potentials (TMAP) shows 100% sensitivity for predicting postoperative neuropraxia in initial 107 prone LLIF cases. Spine J. 2024;S79\u201380. https:\/\/doi.org\/10.1016\/j.spinee.2024.06.055. 24(9, Supplement.","DOI":"10.1016\/j.spinee.2024.06.055"},{"issue":"4","key":"1489_CR198","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1097\/brs.0b013e3181b9654f","volume":"35","author":"R Bosnjak","year":"2010","unstructured":"Bosnjak R, Makovec M. Neurophysiological monitoring of S1 root function during microsurgical posterior discectomy using H-reflex and spinal nerve root potentials. Spine (Phila Pa 1976). 2010;35(4):423\u20139. https:\/\/doi.org\/10.1097\/brs.0b013e3181b9654f.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1489_CR199","doi-asserted-by":"publisher","unstructured":"Leppanen RE. Monitoring spinal nerve function with H-reflexes. J Clin Neurophysiol. 2012;29(2). https:\/\/doi.org\/10.1097\/wnp.0b013e31824ceec5. 126\u2009\u2013\u200939.","DOI":"10.1097\/wnp.0b013e31824ceec5"},{"key":"1489_CR200","doi-asserted-by":"publisher","unstructured":"Stecker MM. A review of intraoperative monitoring for spinal surgery. Surg Neurol Int. 2012;3(Suppl 3). https:\/\/doi.org\/10.4103\/2152-7806.98579. p. S174-87.","DOI":"10.4103\/2152-7806.98579"},{"issue":"2","key":"1489_CR201","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/s10877-018-0201-9","volume":"33","author":"JH Gertsch","year":"2019","unstructured":"Gertsch JH, Moreira JJ, Lee GR. Practice guidelines for the supervising professional: intraoperative neurophysiological monitoring. J Clin Monit Comput. 2019;33(2):175\u201383. https:\/\/doi.org\/10.1007\/s10877-018-0201-9.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"1489_CR202","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1007\/s10877-009-9191-y","volume":"23","author":"MR Isley","year":"2009","unstructured":"Isley MR, Edmonds HL Jr, Stecker M, American Society of Neurophysiological Monitoring. Guidelines for intraoperative neuromonitoring using raw (analog or digital waveforms) and quantitative electroencephalography: a position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2009;23(6):369\u201390. https:\/\/doi.org\/10.1007\/s10877-009-9191-y.","journal-title":"J Clin Monit Comput"},{"key":"1489_CR203","first-page":"38","volume":"34","author":"MR Isley","year":"2006","unstructured":"Isley MR, Pearlman RC. Credentialing and competency policy statement for intraoperative neuromonitoring staff: American Society of Neurophysiological Monitoring position statement. Synergy. 2006;34:38\u201341.","journal-title":"Synergy"},{"issue":"4","key":"1489_CR204","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/mus.27850","volume":"40","author":"JR L\u00f3pez","year":"2023","unstructured":"L\u00f3pez JR, Ahn-Ewing J, Emerson R. Guidelines for Qualifications of Neurodiagnostic Personnel: A Joint Position Statement of the American Clinical Neurophysiology Society, the American Association of Neuromuscular & Electrodiagnostic Medicine, the American Society of Neurophysiological Monitoring, and ASET-The Neurodiagnostic Society. J Clin Neurophysiol. 2023;40(4):271\u201385. https:\/\/doi.org\/10.1002\/mus.27850.","journal-title":"J Clin Neurophysiol"},{"issue":"2","key":"1489_CR205","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/s10877-013-9496-8","volume":"28","author":"SA Skinner","year":"2014","unstructured":"Skinner SA, Cohen BA, Morledge DE, McAuliffe JJ, Hastings JD, Yingling CD, McCaffrey M. Practice guidelines for the supervising professional: intraoperative neurophysiological monitoring. J Clin Monit Comput. 2014;28(2):103\u201311. https:\/\/doi.org\/10.1007\/s10877-013-9496-8.","journal-title":"J Clin Monit Comput"},{"key":"1489_CR206","unstructured":"Society A-TN. National competency skill standards for performing intraoperative neurophysiologic monitoring. 2022 [cited 2025 18 Sep]; Available from: https:\/\/www.aset.org\/wp-content\/uploads\/2022\/11\/IONM_Competencies_FINAL.pdf"},{"key":"1489_CR207","unstructured":"American Audiology Board of Intraoperative Monitoring. What is the value of specialty board certification in IOM for an audiologist. [cited 2025 18 Sep]; Available from: https:\/\/www.aabiom.com\/"},{"key":"1489_CR208","unstructured":"ABRET. ABRET neurodiagnostic credentialing and accommodation. [cited 2025 18 Sep]; Available from: https:\/\/abret.org\/"},{"issue":"1","key":"1489_CR209","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1007\/s10877-005-9000-1","volume":"20","author":"DE Morledge","year":"2006","unstructured":"Morledge DE, Stecker M. The American Society of Neurophysiological Monitoring position statements project. J Clin Monit Comput. 2006;20(1):43\u20136. https:\/\/doi.org\/10.1007\/s10877-005-9000-1.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"1489_CR210","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1111\/jebm.12018","volume":"6","author":"G Goldet","year":"2013","unstructured":"Goldet G, Howick J. Understanding GRADE: an introduction. J Evid Based Med. 2013;6(1):50\u20134. https:\/\/doi.org\/10.1111\/jebm.12018.","journal-title":"J Evid Based Med"},{"issue":"4","key":"1489_CR211","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.jclinepi.2010.04.026","volume":"64","author":"G Guyatt","year":"2011","unstructured":"Guyatt G, Oxman AD, Akl EA, et al. GRADE guidelines: 1. Introduction-GRADE evidence profiles and summary of findings tables. J Clin Epidemiol. 2011;64(4):383\u201394. https:\/\/doi.org\/10.1016\/j.jclinepi.2010.04.026.","journal-title":"J Clin Epidemiol"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01489-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-026-01489-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01489-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T09:53:21Z","timestamp":1789638801000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-026-01489-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,17]]},"references-count":211,"alternative-id":["1489"],"URL":"https:\/\/doi.org\/10.1007\/s10877-026-01489-x","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,17]]},"assertion":[{"value":"5 August 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Stanley Skinner holds a royalty-bearing relationship with Medtronic, Inc. All remaining authors have no relevant financial or non-financial interests to disclose.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This document presents the updated American Society of Neurophysiological Monitoring (ASNM) position statement on intraoperative electromyography. This position statement is based on information presented at scientific meetings, published in the current scientific and clinical literature, and presented in previously published guidelines and position statements of various clinical societies. This document may not include all possible methodologies and interpretive criteria, nor is it intended to exclude any new innovations or developments that occur within the currently established protocols. Furthermore, ASNM recognizes this position statement as an educational service.","order":2,"name":"Ethics","label":"ASNM position statement endorsement","group":{"name":"EthicsHeading","label":"Declarations"}}]}}