{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:57:29Z","timestamp":1790719049121,"version":"4.1.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Clin Monit Comput"],"DOI":"10.1007\/s10877-026-01505-0","type":"journal-article","created":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T03:58:11Z","timestamp":1790567891000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Low baseline Tc-MEP amplitude is associated with false-positive alerts in spine surgery: a ROC-based analysis across spinal pathologies"],"prefix":"10.1007","author":[{"given":"Shuyun","family":"Jiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7722-2205","authenticated-orcid":false,"given":"Hiroki","family":"Ushirozako","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Go","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiko","family":"Hasegawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiro","family":"Banno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideyuki","family":"Arima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shin","family":"Oe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiro","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koichiro","family":"Ide","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kouki","family":"Yamaguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeru","family":"Aketa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukihiro","family":"Matsuyama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Yamato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,28]]},"reference":[{"key":"1505_CR1","doi-asserted-by":"publisher","first-page":"S105","DOI":"10.1177\/21925682231196514","volume":"14","author":"MA Alvi","year":"2024","unstructured":"Alvi MA, Kwon BK, Hejrati N, et al. Accuracy of intraoperative neuromonitoring in the diagnosis of intraoperative neurological decline in the setting of spinal surgery-a systematic review and meta-analysis. Global Spine J. 2024;14:S105\u201349. https:\/\/doi.org\/10.1177\/21925682231196514.","journal-title":"Global Spine J"},{"key":"1505_CR2","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1177\/21925682231219224","volume":"14","author":"RP Reddy","year":"2024","unstructured":"Reddy RP, Singh-Varma A, Chang R, et al. Transcranial motor evoked potentials as a predictive modality for postoperative deficit in cervical spine decompression surgery - a systematic review and meta-analysis. Global Spine J. 2024;14:1609\u201328. https:\/\/doi.org\/10.1177\/21925682231219224.","journal-title":"Global Spine J"},{"key":"1505_CR3","doi-asserted-by":"publisher","first-page":"E1069","DOI":"10.1097\/BRS.0000000000004065","volume":"46","author":"M Takahashi","year":"2021","unstructured":"Takahashi M, Imagama S, Kobayashi K, et al. Validity of the alarm point in intraoperative neurophysiological monitoring of the spinal cord by the monitoring working group of the Japanese society for spine surgery and related research: a prospective multicenter cohort study of 1934 cases. Spine (Phila Pa 1976). 2021;46:E1069\u201376. https:\/\/doi.org\/10.1097\/BRS.0000000000004065.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR4","doi-asserted-by":"publisher","first-page":"2012","DOI":"10.1177\/21925682231164344","volume":"14","author":"CS Lee","year":"2024","unstructured":"Lee CS, Hwang C-J, Lee D-H, et al. Risk factors and exit strategy of intraoperative neurophysiological monitoring alert during deformity correction for adolescent idiopathic scoliosis. Global Spine J. 2024;14:2012\u201321. https:\/\/doi.org\/10.1177\/21925682231164344.","journal-title":"Global Spine J"},{"key":"1505_CR5","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1177\/21925682211011443","volume":"13","author":"H Ushirozako","year":"2023","unstructured":"Ushirozako H, Yoshida G, Imagama S, et al. Efficacy of transcranial motor evoked potential monitoring during intra- and extramedullary spinal cord tumor surgery: a prospective multicenter study of the monitoring committee of the Japanese society for spine surgery and related research. Global Spine J. 2023;13:961\u20139. https:\/\/doi.org\/10.1177\/21925682211011443.","journal-title":"Global Spine J"},{"key":"1505_CR6","doi-asserted-by":"publisher","first-page":"E1211","DOI":"10.1097\/BRS.0000000000004074","volume":"46","author":"K Kobayashi","year":"2021","unstructured":"Kobayashi K, Imagama S, Ando K, et al. Characteristics of cases with poor transcranial motor-evoked potentials baseline waveform derivation in spine surgery: a prospective multicenter study of the monitoring committee of the japanese society for spine surgery and related research. Spine (Phila Pa 1976). 2021;46:E1211\u20139. https:\/\/doi.org\/10.1097\/BRS.0000000000004074.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR7","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1097\/BRS.0000000000004096","volume":"46","author":"K Kobayashi","year":"2021","unstructured":"Kobayashi K, Ando K, Yoshida G, et al. Characteristics of Tc-MEP waveforms in spine surgery for patients with severe obesity. Spine (Phila Pa 1976). 2021;46:1738\u201347. https:\/\/doi.org\/10.1097\/BRS.0000000000004096.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR8","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1097\/BRS.0000000000004246","volume":"47","author":"G Yoshida","year":"2022","unstructured":"Yoshida G, Ushirozako H, Imagama S, et al. Transcranial motor-evoked potential alert after supine-to-prone position change during thoracic ossification in posterior longitudinal ligament surgery: a prospective multicenter study of the monitoring committee of the japanese society for spine surgery and related research. Spine (Phila Pa 1976). 2022;47:1018\u201326. https:\/\/doi.org\/10.1097\/BRS.0000000000004246.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR9","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1097\/BRS.0000000000004448","volume":"47","author":"M Funaba","year":"2022","unstructured":"Funaba M, Kanchiku T, Kobayashi K, et al. The utility of transcranial stimulated motor-evoked potential alerts in cervical spine surgery varies based on preoperative motor status. Spine (Phila Pa 1976). 2022;47:1659\u201368. https:\/\/doi.org\/10.1097\/BRS.0000000000004448.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR10","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1177\/21925682231196454","volume":"15","author":"M Funaba","year":"2025","unstructured":"Funaba M, Kanchiku T, Yoshida G, et al. Impact of preoperative motor status for the positive predictive value of transcranial motor-evoked potentials alerts in thoracic spine surgery: a prospective multicenter study by the monitoring committee of the japanese society for spine surgery and related research. Global Spine J. 2025;15:506\u201317. https:\/\/doi.org\/10.1177\/21925682231196454.","journal-title":"Global Spine J"},{"key":"1505_CR11","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1097\/WNP.0000000000000338","volume":"34","author":"HL Journ\u00e9e","year":"2017","unstructured":"Journ\u00e9e HL, Berends HI, Kruyt MC. The percentage of amplitude decrease warning criteria for transcranial MEP monitoring. J Clin Neurophysiol. 2017;34:22\u201331. https:\/\/doi.org\/10.1097\/WNP.0000000000000338.","journal-title":"J Clin Neurophysiol"},{"key":"1505_CR12","doi-asserted-by":"publisher","first-page":"102","DOI":"10.3171\/2013.10.SPINE12944","volume":"20","author":"S Kobayashi","year":"2014","unstructured":"Kobayashi S, Matsuyama Y, Shinomiya K, et al. A new alarm point of transcranial electrical stimulation motor evoked potentials for intraoperative spinal cord monitoring: a prospective multicenter study from the Spinal Cord Monitoring Working Group of the Japanese Society for Spine Surgery and Related Research. J Neurosurg Spine. 2014;20:102\u20137. https:\/\/doi.org\/10.3171\/2013.10.SPINE12944.","journal-title":"J Neurosurg Spine"},{"key":"1505_CR13","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1097\/BRS.0000000000003774","volume":"46","author":"K Kobayashi","year":"2021","unstructured":"Kobayashi K, Imagama S, Yoshida G, et al. Efficacy of intraoperative intervention following transcranial motor-evoked potentials alert during posterior decompression and fusion surgery for thoracic ossification of the posterior longitudinal ligament: a prospective multicenter study of the monitoring committee of the japanese society for spine surgery and related research. Spine (Phila Pa 1976). 2021;46:268\u201376. https:\/\/doi.org\/10.1097\/BRS.0000000000003774.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR14","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.medengphy.2015.11.007","volume":"38","author":"A Farajidavar","year":"2016","unstructured":"Farajidavar A, Seifert JL, Delgado MR, et al. Electromagnetic interference in intraoperative monitoring of motor evoked potentials and a wireless solution. Med Eng Phys. 2016;38:87\u201396. https:\/\/doi.org\/10.1016\/j.medengphy.2015.11.007.","journal-title":"Med Eng Phys"},{"key":"1505_CR15","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1038\/s41593-023-01346-z","volume":"26","author":"MA Jensen","year":"2023","unstructured":"Jensen MA, Huang H, Valencia GO, et al. A motor association area in the depths of the central sulcus. Nat Neurosci. 2023;26:1165\u20139. https:\/\/doi.org\/10.1038\/s41593-023-01346-z.","journal-title":"Nat Neurosci"},{"key":"1505_CR16","doi-asserted-by":"publisher","first-page":"e30841","DOI":"10.1097\/MD.0000000000030841","volume":"101","author":"H Hayashi","year":"2022","unstructured":"Hayashi H, Yamada M, Okuyama K, et al. Retrospective observational study of the effects of residual neuromuscular blockade and sugammadex on motor-evoked potential monitoring during spine surgery in Japan. Med (Baltim). 2022;101:e30841. https:\/\/doi.org\/10.1097\/MD.0000000000030841.","journal-title":"Med (Baltim)"},{"key":"1505_CR17","doi-asserted-by":"publisher","first-page":"4433","DOI":"10.3390\/jcm12134433","volume":"12","author":"T Toki","year":"2023","unstructured":"Toki T, Fujita N, Ichikawa T, et al. Factors affecting transcranial motor-evoked potential measurements using single-train stimulation with an increased number of pulses during adolescent scoliosis surgery: a prospective observational study. J Clin Med. 2023;12:4433. https:\/\/doi.org\/10.3390\/jcm12134433.","journal-title":"J Clin Med"},{"key":"1505_CR18","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2009.8.FOCUS09145","volume":"27","author":"AC Wang","year":"2009","unstructured":"Wang AC, Than KD, Etame AB, et al. Impact of anesthesia on transcranial electric motor evoked potential monitoring during spine surgery: a review of the literature. Neurosurg Focus. 2009;27:E7. https:\/\/doi.org\/10.3171\/2009.8.FOCUS09145.","journal-title":"Neurosurg Focus"},{"key":"1505_CR19","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/j.spinee.2023.11.022","volume":"24","author":"J-S Kim","year":"2024","unstructured":"Kim J-S, Kim H, Hyun S-J, et al. Different cutoff value of motor evoked potentials for the postoperative outcome in the ossification of the posterior longitudinal ligament surgery in the cervical and thoracic spine. Spine J. 2024;24:572\u201381. https:\/\/doi.org\/10.1016\/j.spinee.2023.11.022.","journal-title":"Spine J"},{"key":"1505_CR20","doi-asserted-by":"publisher","first-page":"E470","DOI":"10.1097\/BRS.0000000000002900","volume":"44","author":"G Yoshida","year":"2019","unstructured":"Yoshida G, Ando M, Imagama S, et al. Alert timing and corresponding intervention with intraoperative spinal cord monitoring for high-risk spinal surgery. Spine (Phila Pa 1976). 2019;44:E470\u20139. https:\/\/doi.org\/10.1097\/BRS.0000000000002900.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR21","doi-asserted-by":"publisher","first-page":"423","DOI":"10.3171\/2019.9.SPINE19814","volume":"32","author":"H Ushirozako","year":"2020","unstructured":"Ushirozako H, Yoshida G, Hasegawa T, et al. Characteristics of false-positive alerts on transcranial motor evoked potential monitoring during pediatric scoliosis and adult spinal deformity surgery: an anesthetic fade phenomenon. J Neurosurg Spine. 2020;32:423\u201331. https:\/\/doi.org\/10.3171\/2019.9.SPINE19814.","journal-title":"J Neurosurg Spine"},{"key":"1505_CR22","doi-asserted-by":"publisher","first-page":"3041","DOI":"10.1097\/BRS.0b013e31815d0072","volume":"32","author":"DH Kim","year":"2007","unstructured":"Kim DH, Zaremski J, Kwon B, et al. Risk factors for false positive transcranial motor evoked potential monitoring alerts during surgical treatment of cervical myelopathy. Spine (Phila Pa 1976). 2007;32:3041\u20136. https:\/\/doi.org\/10.1097\/BRS.0b013e31815d0072.","journal-title":"Spine (Phila Pa 1976)"},{"key":"1505_CR23","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1186\/s13018-018-0934-7","volume":"13","author":"R Ugawa","year":"2018","unstructured":"Ugawa R, Takigawa T, Shimomiya H, et al. An evaluation of anesthetic fade in motor evoked potential monitoring in spinal deformity surgeries. J Orthop Surg Res. 2018;13:227. https:\/\/doi.org\/10.1186\/s13018-018-0934-7.","journal-title":"J Orthop Surg Res"},{"key":"1505_CR24","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1055\/a-2103-7381","volume":"85","author":"S Tanaka","year":"2024","unstructured":"Tanaka S, Yamamoto K, Yoshida S, et al. Anesthetic fade in intraoperative transcranial motor evoked potential monitoring is mainly due to decreased synaptic transmission at the neuromuscular junction by propofol accumulation. J Neurol Surg Cent Eur Neurosurg. 2024;85:451\u20136. https:\/\/doi.org\/10.1055\/a-2103-7381.","journal-title":"J Neurol Surg Cent Eur Neurosurg"},{"key":"1505_CR25","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1007\/s10877-020-00645-1","volume":"35","author":"SE Dulfer","year":"2021","unstructured":"Dulfer SE, Sahinovic MM, Lange F, et al. The influence of depth of anesthesia and blood pressure on muscle recorded motor evoked potentials in spinal surgery. A prospective observational study protocol. J Clin Monit Comput. 2021;35:967\u201377. https:\/\/doi.org\/10.1007\/s10877-020-00645-1.","journal-title":"J Clin Monit Comput"},{"key":"1505_CR26","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/s10877-014-9565-7","volume":"29","author":"S Tsutsui","year":"2015","unstructured":"Tsutsui S, Iwasaki H, Yamada H, et al. Augmentation of motor evoked potentials using multi-train transcranial electrical stimulation in intraoperative neurophysiologic monitoring during spinal surgery. J Clin Monit Comput. 2015;29:35\u20139. https:\/\/doi.org\/10.1007\/s10877-014-9565-7.","journal-title":"J Clin Monit Comput"},{"key":"1505_CR27","doi-asserted-by":"publisher","first-page":"2387","DOI":"10.1177\/21925682221084649","volume":"13","author":"H Shigematsu","year":"2023","unstructured":"Shigematsu H, Ando M, Kobayashi K, et al. Efficacy of D-wave monitoring combined with the transcranial motor-evoked potentials in high-risk spinal surgery: a retrospective multicenter study of the monitoring committee of the japanese society for spine surgery and related research. Global Spine J. 2023;13:2387\u201395. https:\/\/doi.org\/10.1177\/21925682221084649.","journal-title":"Global Spine J"},{"key":"1505_CR28","doi-asserted-by":"publisher","first-page":"2399","DOI":"10.1177\/21925682241242693","volume":"14","author":"C Cottone","year":"2024","unstructured":"Cottone C, Kim D, Lucasti C, et al. Causes of intraoperative neuromonitoring events in adult spine deformity surgery: a systematic review. Global Spine J. 2024;14:2399\u2013407. https:\/\/doi.org\/10.1177\/21925682241242693.","journal-title":"Global Spine J"}],"container-title":["Journal of Clinical Monitoring and Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01505-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10877-026-01505-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10877-026-01505-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:01:09Z","timestamp":1790715669000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10877-026-01505-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,28]]},"references-count":28,"alternative-id":["1505"],"URL":"https:\/\/doi.org\/10.1007\/s10877-026-01505-0","relation":{},"ISSN":["1573-2614"],"issn-type":[{"value":"1573-2614","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,28]]},"assertion":[{"value":"27 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. The study protocol was approved by the Institutional Review Board of Hamamatsu University School of Medicine (approval no. 26\u2013049).","order":1,"name":"Ethics","label":"Ethics approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived by the Institutional Review Board because of the retrospective design.","order":2,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent to publish","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}