{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T20:02:19Z","timestamp":1791403339781,"version":"4.3.3"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2025,4,21]],"date-time":"2025-04-21T00:00:00Z","timestamp":1745193600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,21]],"date-time":"2025-04-21T00:00:00Z","timestamp":1745193600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Ankara Bilim University","award":["No EEE-2022-02"],"award-info":[{"award-number":["No EEE-2022-02"]}]},{"name":"Ankara Science University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Fluoresc"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Tro\u00a0ponin is a biomolecule found in the blood of humans that can be used as an indicator of cardiac damage and cardiovascular risk. In this study, a turn-on fluorescence-based biosensor was developed using CdSe\/ZnS quantum nanoparticles with high fluorescence efficiency decorated on superparamagnetic nanoparticles and aptamer as a probe for cardiac troponin I detection to improve fluorescence efficiency and create a reusable sensor through magnetic separation. Chemical modifications of biosensor components have been characterized by zeta sizer, zeta potential, UV\u2013Vis spectroscopy, transmission electron microscopy (TEM), and Fourier transform infrared spectroscopy (FTIR). We reported that the developed sensor worked with a \"Turn-on\" mechanism. Fluorescence changes of the developed aptamer-based biosensor were evaluated using a fluorometer, and a low limit of detection (LOD) of 13.3\u00a0ng\/ml with a linear detection range from 2 to 40\u00a0ng\/ml was determined. Additionally, the selectivity and sensitivity of the biosensor have been tested with several biomarkers found in human blood.<\/jats:p>\n                  <jats:p>\n                    <jats:bold>Graphical Abstract<\/jats:bold>\n                  <\/jats:p>","DOI":"10.1007\/s10895-025-04303-0","type":"journal-article","created":{"date-parts":[[2025,4,21]],"date-time":"2025-04-21T14:49:47Z","timestamp":1745246987000},"page":"10233-10244","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Reusable Turn-on Fluorescent Biosensor for Cardiac Biomarker Troponin I Detection Using QDs-SPION-Aptamer"],"prefix":"10.1007","volume":"35","author":[{"given":"Ayse","family":"Ozdemir","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yigitcan","family":"Alg\u00fcl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nimet Yildirim","family":"Tirgil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,4,21]]},"reference":[{"key":"4303_CR1","volume-title":"A perspective of advanced biosensors for environmental monitoring","author":"RM Balakrishnan","year":"2020","unstructured":"Balakrishnan RM, Uddandarao P, Raval K, Raval R (2020) A perspective of advanced biosensors for environmental monitoring. Elsevier, Amsterdam"},{"key":"4303_CR2","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1093\/fqsafe\/fyab019","volume":"5","author":"FF Sun","year":"2021","unstructured":"Sun FF, Zhang J, Yang QL, Wu W (2021) Quantum dot biosensor combined with antibody and aptamer for tracing food-borne pathogens. Food Qual Safety 5:10","journal-title":"Food Qual Safety"},{"key":"4303_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jiec.2019.04.037","volume":"77","author":"SE Seo","year":"2019","unstructured":"Seo SE, Tabei F, Park SJ, Askarian B, Kim KH, Moallem G, Chong JW, Kwon OS (2019) Smartphone with optical, physical, and electrochemical nanobiosensors. J Ind Eng Chem 77:1\u201311","journal-title":"J Ind Eng Chem"},{"issue":"1","key":"4303_CR4","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1039\/b005847p","volume":"126","author":"C Xu","year":"2001","unstructured":"Xu C, Cai H, He P, Fang Y (2001) Electrochemical detection of sequence-specific DNA using a DNA probe labeled with aminoferrocene and chitosan modified electrode immobilized with ssDNA. Analyst 126(1):62\u201365","journal-title":"Analyst"},{"issue":"20","key":"4303_CR5","doi-asserted-by":"publisher","first-page":"12858","DOI":"10.1039\/D2RA90047E","volume":"12","author":"JS Chen","year":"2022","unstructured":"Chen JS, Ran FY, Chen QH, Luo D, Ma WD, Han T, Wang CM, Wang CX (2022) A fluorescent biosensor for cardiac biomarker myoglobin detection based on carbon dots and deoxyribonuclease I-aided target recycling signal amplification (vol 9, pg 4463, 2019). RSC Adv 12(20):12858\u201312858","journal-title":"RSC Adv"},{"issue":"11","key":"4303_CR6","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/s00604-020-04577-0","volume":"187","author":"B Chatterjee","year":"2020","unstructured":"Chatterjee B, Kalyani N, Anand A, Khan E, Das S, Bansal V, Kumar A, Sharma TK (2020) GOLD SELEX: a novel SELEX approach for the development of high-affinity aptamers against small molecules without residual activity. Microchim Acta 187(11):13","journal-title":"Microchim Acta"},{"issue":"5","key":"4303_CR7","doi-asserted-by":"publisher","first-page":"1551","DOI":"10.1039\/C5AN01824B","volume":"141","author":"M Ilgu","year":"2016","unstructured":"Ilgu M, Nilsen-Hamilton M (2016) Aptamers in analytics. Analyst 141(5):1551\u20131568","journal-title":"Analyst"},{"issue":"16","key":"4303_CR8","doi-asserted-by":"publisher","first-page":"3419","DOI":"10.1021\/ac9802325","volume":"70","author":"RA Potyrailo","year":"1998","unstructured":"Potyrailo RA, Conrad RC, Ellington AD, Hieftje GM (1998) Adapting selected nucleic acid ligands (aptamers) to biosensors. Anal Chem 70(16):3419\u20133425","journal-title":"Anal Chem"},{"issue":"3","key":"4303_CR9","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1021\/ac702322j","volume":"80","author":"YF Huang","year":"2008","unstructured":"Huang YF, Chang HT, Tan WH (2008) Cancer cell targeting using multiple aptamers conjugated on nanorods. Anal Chem 80(3):567\u2013572","journal-title":"Anal Chem"},{"issue":"6","key":"4303_CR10","doi-asserted-by":"publisher","first-page":"980","DOI":"10.2174\/1871530320999200831171748","volume":"21","author":"S Khan","year":"2021","unstructured":"Khan S, Rasool ST (2021) Current Use of Cardiac Biomarkers in Various Heart Conditions. Endocr Metab Immune Disord Drug Targets 21(6):980\u2013993","journal-title":"Endocr Metab Immune Disord Drug Targets"},{"key":"4303_CR11","first-page":"395","volume":"43","author":"ML Beck","year":"1997","unstructured":"Beck ML, Dameron GW, Kang YJ, Erickson BK, DiBattista TH, Miller KE, Jackson KN, Mittelstadt S, Obrien PJ (1997) Cardiac troponin T is a sensitive and specific biomarker of cardiac injury in laboratory. Clin Chem 43:395\u2013395","journal-title":"Clin Chem"},{"issue":"40","key":"4303_CR12","doi-asserted-by":"publisher","first-page":"25899","DOI":"10.1021\/acsomega.0c03260","volume":"5","author":"JT Zhang","year":"2020","unstructured":"Zhang JT, Lakshmipriya T, Gopinath SCB (2020) Electroanalysis on an Interdigitated Electrode for High-Affinity Cardiac Troponin I Biomarker Detection by Aptamer-Gold Conjugates. ACS Omega 5(40):25899\u201325905","journal-title":"ACS Omega"},{"issue":"3","key":"4303_CR13","doi-asserted-by":"publisher","first-page":"312","DOI":"10.5853\/jos.2016.01942","volume":"19","author":"SH Ahn","year":"2017","unstructured":"Ahn SH, Lee JS, Kim YH, Kim BJ, Kim YJ, Kang DW, Kim JS, Kwon SU (2017) Prognostic Significance of Troponin Elevation for Long-Term Mortality after Ischemic Stroke. J Stroke 19(3):312","journal-title":"J Stroke"},{"issue":"12","key":"4303_CR14","first-page":"905","volume":"80","author":"A Markota","year":"2011","unstructured":"Markota A, Bernhardt M, Palfy M (2011) Comparison of point-of-care and Laboratory troponin I assays. Zdravniski Vestnik-Slovenian Med J 80(12):905\u2013908","journal-title":"Zdravniski Vestnik-Slovenian Med J"},{"issue":"1","key":"4303_CR15","doi-asserted-by":"publisher","first-page":"e29375","DOI":"10.1002\/jmv.29375","volume":"96","author":"W Ding","year":"2024","unstructured":"Ding W, Gong C, Meng T, Xiang X, Hong B, Shen S, Ding S (2024) Cardiac injury in hospitalized patients with severe fever and thrombocytopenia syndrome. J Med Virol 96(1):e29375","journal-title":"J Med Virol"},{"issue":"6","key":"4303_CR16","doi-asserted-by":"publisher","first-page":"2836","DOI":"10.1166\/jnn.2008.15348","volume":"8","author":"M Knobel","year":"2008","unstructured":"Knobel M, Nunes WC, Socolovsky LM, De Biasi E, Vargas JM, Denardin JC (2008) Superparamagnetism and other magnetic features in granular materials: a review on ideal and real systems. J Nanosci Nanotechnol 8(6):2836\u20132857","journal-title":"J Nanosci Nanotechnol"},{"issue":"3","key":"4303_CR17","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1021\/acsbiomaterials.6b00311","volume":"3","author":"N Gal","year":"2017","unstructured":"Gal N, Lassenberger A, Herrero-Nogareda L, Scheberl A, Charwat V, Kasper C, Reimhult E (2017) Interaction of Size-Tailored PEGylated Iron Oxide Nanoparticles with Lipid Membranes and Cells. ACS Biomater Sci Eng 3(3):249\u2013259","journal-title":"ACS Biomater Sci Eng"},{"key":"4303_CR18","doi-asserted-by":"publisher","first-page":"110651","DOI":"10.1016\/j.msec.2020.110651","volume":"110","author":"TK Henna","year":"2020","unstructured":"Henna TK, Pramod K (2020) Graphene quantum dots redefine nanobiomedicine. Mater Sci Eng, C 110:110651","journal-title":"Mater Sci Eng, C"},{"key":"4303_CR19","doi-asserted-by":"crossref","unstructured":"S Pleskova, E Mikheeva, and E Gornostaeva (2018) \"Using of Quantum Dots in Biology and Medicine,\" Cellular and molecular toxicology of nanoparticles, advances in experimental medicine and biology Q. Saquib, M. Faisal, A. A. AlKhedhairy and A. A. Alatar, eds., pp. 323\u2013334, Cham: Springer International Publishing Ag","DOI":"10.1007\/978-3-319-72041-8_19"},{"key":"4303_CR20","first-page":"7073","volume":"10","author":"QQ Liu","year":"2015","unstructured":"Liu QQ, Li HX, Xia QY, Liu Y, Xiao K (2015) Role of surface charge in determining the biological effects of CdSe\/ZnS quantum dots. Int J Nanomed 10:7073\u20137088","journal-title":"Int J Nanomed"},{"key":"4303_CR21","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1155\/2009\/815734","volume":"2009","author":"S Mazumder","year":"2009","unstructured":"Mazumder S, Dey R, Mitra MK, Mukherjee S, Das GC (2009) Review: Biofunctionalized Quantum Dots in Biology and Medicine. J Nanomater 2009:17","journal-title":"J Nanomater"},{"issue":"12","key":"4303_CR22","doi-asserted-by":"publisher","first-page":"2850","DOI":"10.1088\/0957-4484\/17\/12\/004","volume":"17","author":"GH Du","year":"2006","unstructured":"Du GH, Liu ZL, Lu QH, Xia X, Jia LH, Yao KL, Chu Q, Zhang SM (2006) Fe3O4\/CdSe\/ZnS magnetic fluorescent bifunctional nanocomposites. Nanotechnology 17(12):2850\u20132854","journal-title":"Nanotechnology"},{"key":"4303_CR23","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1038\/s41598-017-11087-2","volume":"7","author":"H Motaghi","year":"2017","unstructured":"Motaghi H, Mehrgardi MA, Bouvet P (2017) Carbon Dots-AS1411 aptamer nanoconjugate for ultrasensitive spectrofluorometric detection of cancer cells. Sci Rep 7:8","journal-title":"Sci Rep"},{"issue":"2","key":"4303_CR24","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/S0003-2697(03)00407-X","volume":"321","author":"J Wei","year":"2003","unstructured":"Wei J, Mu Y, Song D, Fang X, Liu X, Bu L, Zhang H, Zhang G, Ding J, Wang W, Jin Q, Luo G (2003) A novel sandwich immunosensing method for measuring cardiac troponin I in sera. Anal Biochem 321(2):209\u2013216","journal-title":"Anal Biochem"},{"issue":"2","key":"4303_CR25","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.aca.2008.11.019","volume":"632","author":"IH Cho","year":"2009","unstructured":"Cho IH, Paek EH, Kim YK, Kim JH, Paek SH (2009) Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography. Anal Chim Acta 632(2):247\u201355","journal-title":"Anal Chim Acta"},{"issue":"1","key":"4303_CR26","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.snb.2010.03.027","volume":"147","author":"W-Y Wu","year":"2010","unstructured":"Wu W-Y, Bian Z-P, Wang W, Zhu J-J (2010) PDMS gold nanoparticle composite film-based silver enhanced colorimetric detection of cardiac troponin I. Sens Actuators, B Chem 147(1):298\u2013303","journal-title":"Sens Actuators, B Chem"},{"issue":"1","key":"4303_CR27","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.bios.2012.02.019","volume":"34","author":"T Kong","year":"2012","unstructured":"Kong T, Su R, Zhang B, Zhang Q, Cheng G (2012) CMOS-compatible, label-free silicon-nanowire biosensors to detect cardiac troponin I for acute myocardial infarction diagnosis. Biosens Bioelectron 34(1):267\u201372","journal-title":"Biosens Bioelectron"},{"key":"4303_CR28","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.aca.2013.11.047","volume":"809","author":"SK Tuteja","year":"2014","unstructured":"Tuteja SK, Bhalla V, Deep A, Paul AK, Suri CR (2014) Graphene-gated biochip for the detection of cardiac marker Troponin I. Anal Chim Acta 809:148\u201354","journal-title":"Anal Chim Acta"},{"key":"4303_CR29","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1016\/j.snb.2016.09.131","volume":"242","author":"MF Fathil","year":"2017","unstructured":"Fathil MF, Arshad MM, Ruslinda AR, Gopinath SC, Nuzaihan M, Adzhri R, Hashim U, Lam HY (2017) Substrate-gate coupling in ZnO-FET biosensor for cardiac troponin I detection. Sens Actuat B: Chem 242:1142\u201354","journal-title":"Sens Actuat B: Chem"},{"key":"4303_CR30","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.2147\/IJN.S507715","volume":"31","author":"H Yu","year":"2025","unstructured":"Yu H, Yu J, Yao G (2025) Recent advances in aptamers-based nanosystems for diagnosis and therapy of cardiovascular diseases: an\u00a0updated\u00a0review. Int J Nanomed 31:2427\u201343","journal-title":"Int J Nanomed"},{"issue":"7","key":"4303_CR31","doi-asserted-by":"publisher","first-page":"2368","DOI":"10.1021\/nl100168s","volume":"10","author":"WK Bae","year":"2010","unstructured":"Bae WK, Kwak J, Lim J, Lee D, Nam MK, Char K, Lee C, Lee S (2010) Multicolored light-emitting diodes based on all-quantum-dot multilayer films using layer-by-layer assembly method. Nano Lett 10(7):2368\u20132373","journal-title":"Nano Lett"},{"issue":"15","key":"4303_CR32","doi-asserted-by":"publisher","first-page":"4482","DOI":"10.1039\/D1NA00079A","volume":"3","author":"S Yildiz","year":"2021","unstructured":"Yildiz S, Solak K, Acar M, Mavi A, Unver Y (2021) Magnetic nanoparticle mediated-gene delivery for simpler and more effective transformation of. Nanoscale Adv 3(15):4482\u20134491","journal-title":"Nanoscale Adv"},{"issue":"10","key":"4303_CR33","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1007\/s00604-024-06666-w","volume":"191","author":"S Singh","year":"2024","unstructured":"Singh S, Agrawal RK, Nara S (2024) Electrochemical aptasensor for sensitive detection of staphylococcal enterotoxin type A in milk and fruit juice. Mikrochim Acta 191(10):636","journal-title":"Mikrochim Acta"},{"issue":"4","key":"4303_CR34","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/s42452-022-04948-7","volume":"4","author":"C Li","year":"2022","unstructured":"Li C, Hassan A, Palmai M, Snee P, Baveye PC, Darnault CJG (2022) Colloidal stability and aggregation kinetics of nanocrystal CdSe\/ZnS quantum dots in aqueous systems: effects of ionic strength, electrolyte type, and natural organic matter. SN Appl Sci 4(4):101","journal-title":"SN Appl Sci"},{"issue":"8","key":"4303_CR35","doi-asserted-by":"publisher","first-page":"1805","DOI":"10.1007\/s11051-013-1805-0","volume":"15","author":"Y Wang","year":"2013","unstructured":"Wang Y, Zhu H, Becker MD, Englehart J, Abriola LM, Colvin VL, Pennell KD (2013) Effect of surface coating composition on quantum dot mobility in porous media. J Nanopart Res 15(8):1805","journal-title":"J Nanopart Res"},{"issue":"10","key":"4303_CR36","doi-asserted-by":"publisher","first-page":"e0205590","DOI":"10.1371\/journal.pone.0205590","volume":"13","author":"I Michalak","year":"2018","unstructured":"Michalak I, Mironiuk M, Marycz K (2018) A comprehensive analysis of biosorption of metal ions by macroalgae using ICP-OES, SEM-EDX and FTIR techniques. PLoS ONE 13(10):e0205590","journal-title":"PLoS ONE"},{"key":"4303_CR37","doi-asserted-by":"publisher","first-page":"117962","DOI":"10.1016\/j.saa.2019.117962","volume":"229","author":"A Kumari","year":"2020","unstructured":"Kumari A, Thakur N, Vashishtt J, Singh RR (2020) Structural, luminescent and antimicrobial properties of ZnS and CdSe\/ZnS quantum dot structures originated by precursors. Spectrochim Acta A Mol Biomol Spectrosc 229:117962","journal-title":"Spectrochim Acta A Mol Biomol Spectrosc"},{"issue":"22","key":"4303_CR38","doi-asserted-by":"publisher","first-page":"22D507","DOI":"10.1063\/1.4895796","volume":"141","author":"VA L\u00f3renz-Fonfr\u00eda","year":"2014","unstructured":"L\u00f3renz-Fonfr\u00eda VA, Muders V, Schlesinger R, Heberle J (2014) Changes in the hydrogen-bonding strength of internal water molecules and cysteine residues in the conductive state of channelrhodopsin-1. J Chem Phys 141(22):22D507","journal-title":"J Chem Phys"},{"issue":"9","key":"4303_CR39","doi-asserted-by":"publisher","first-page":"e0289731","DOI":"10.1371\/journal.pone.0289731","volume":"18","author":"S Sundara","year":"2023","unstructured":"Sundara S, Rajan RJ, Francis Thomas D, Daniel EC (2023) Effective gene delivery using size dependant nano core-shell in human cervical cancer cell lines by magnetofection. PLoS One 18(9):e0289731","journal-title":"PLoS One"},{"key":"4303_CR40","doi-asserted-by":"publisher","first-page":"109327","DOI":"10.1016\/j.microc.2023.109327","volume":"194","author":"S Varghese","year":"2023","unstructured":"Varghese S, Madanan AS, Abraham MK, Shkhair AI, Indongo G, Rajeevan G, Vijila NS, George S (2023) \u201cTurn-on\u201d fluorescence sensing of cardiac troponin I based on MnO2 nanosheet quenched mercaptopropionic acid capped Mn2+ doped zinc sulphide quantum dots. Microchem J 194:109327","journal-title":"Microchem J"},{"issue":"2","key":"4303_CR41","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1002\/elsc.201500188","volume":"17","author":"Z Rezaei","year":"2017","unstructured":"Rezaei Z, Ranjbar B (2017) Ultra-sensitive, rapid gold nanoparticle-quantum dot plexcitonic self-assembled aptamer-based nanobiosensor for the detection of human cardiac troponin I. Eng Life Sci 17(2):165\u2013174","journal-title":"Eng Life Sci"},{"key":"4303_CR42","doi-asserted-by":"publisher","first-page":"101785","DOI":"10.1016\/j.eti.2021.101785","volume":"23","author":"IVN Rathnayake","year":"2021","unstructured":"Rathnayake IVN, Megharaj M, Naidu R (2021) Green fluorescent protein based whole cell bacterial biosensor for the detection of bioavailable heavy metals in soil environment. Environ Technol Innov 23:101785","journal-title":"Environ Technol Innov"},{"key":"4303_CR43","doi-asserted-by":"publisher","first-page":"117972","DOI":"10.1016\/j.trac.2024.117972","volume":"180","author":"RMM Santana","year":"2024","unstructured":"Santana RMM, Barbosa LSV, Benzi LG, Castro RC, Ribeiro DSM, Korn MGA, Santos JLM, Teixeira LSG (2024) Strategies for enhancing the selectivity of quantum dot-based fluorometric methods. TrAC, Trends Anal Chem 180:117972","journal-title":"TrAC, Trends Anal Chem"},{"issue":"2","key":"4303_CR44","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1039\/C7TX00301C","volume":"7","author":"R Yan","year":"2018","unstructured":"Yan R, Yu BQ, Yin MM, Zhou ZQ, Xiang X, Han XL, Liu Y, Jiang FL (2018) The interactions of CdTe quantum dots with serum albumin and subsequent cytotoxicity: the influence of homologous ligands. Toxicol Res (Camb) 7(2):147\u2013155","journal-title":"Toxicol Res (Camb)"},{"issue":"36","key":"4303_CR45","doi-asserted-by":"publisher","first-page":"30172","DOI":"10.1021\/acsami.8b10768","volume":"10","author":"HI Park","year":"2018","unstructured":"Park HI, Park SY (2018) Smart fluorescent hydrogel glucose biosensing microdroplets with dual-mode fluorescence quenching and size reduction. ACS Appl Mater Interfaces 10(36):30172\u201330179","journal-title":"ACS Appl Mater Interfaces"},{"issue":"5","key":"4303_CR46","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1038\/nmat1631","volume":"5","author":"SJ Clarke","year":"2006","unstructured":"Clarke SJ, Hollmann CA, Zhang Z, Suffern D, Bradforth SE, Dimitrijevic NM, Minarik WG, Nadeau JL (2006) Photophysics of dopamine-modified quantum dots and effects on biological systems. Nat Mater 5(5):409\u2013417","journal-title":"Nat Mater"}],"container-title":["Journal of Fluorescence"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10895-025-04303-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10895-025-04303-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10895-025-04303-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,2]],"date-time":"2025-12-02T11:03:22Z","timestamp":1764673402000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10895-025-04303-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,21]]},"references-count":46,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2025,10]]}},"alternative-id":["4303"],"URL":"https:\/\/doi.org\/10.1007\/s10895-025-04303-0","relation":{},"ISSN":["1573-4994"],"issn-type":[{"value":"1573-4994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,21]]},"assertion":[{"value":"27 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study does not require any ethics committee approval; the authors accept and declare that no ethical rules were violated in the study\u2019s preparation process.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interest"}}]}}