{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:26:05Z","timestamp":1785522365538,"version":"3.56.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T00:00:00Z","timestamp":1593475200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T00:00:00Z","timestamp":1593475200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008885","name":"Lloyd\u2019s Register Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008885","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Nondestruct Eval"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Steel pipes in process plant applications are often covered with insulation or weather protection that make inspection difficult because the additional layers need to be penetrated to inspect the pipes\u2019 structure. The pulsed eddy current (PEC) method was devised as a means of inspection through the surface layers. However, the performance of a PEC system is dependent on the electrical and magnetic properties of the pipe material, which are generally unknown. Therefore, the use of a calibration block from a different steel will give inaccurate results. The concept of calibrating using <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\tau _0$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msub>\n<mml:mi>\u03c4<\/mml:mi>\n<mml:mn>0<\/mml:mn>\n<\/mml:msub>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> values obtained during inspection has undoubtedly been discussed in the literature. However, no comprehensive work was dedicated to using <jats:inline-formula><jats:alternatives><jats:tex-math>$$|\\nabla |^{-1}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msup>\n<mml:mrow>\n<mml:mo>|<\/mml:mo>\n<mml:mi>\u2207<\/mml:mi>\n<mml:mo>|<\/mml:mo>\n<\/mml:mrow>\n<mml:mrow>\n<mml:mo>-<\/mml:mo>\n<mml:mn>1<\/mml:mn>\n<\/mml:mrow>\n<\/mml:msup>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> to carry out calibration on inspected structure. The linear relationship of the <jats:inline-formula><jats:alternatives><jats:tex-math>$$|\\nabla |^{-1}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msup>\n<mml:mrow>\n<mml:mo>|<\/mml:mo>\n<mml:mi>\u2207<\/mml:mi>\n<mml:mo>|<\/mml:mo>\n<\/mml:mrow>\n<mml:mrow>\n<mml:mo>-<\/mml:mo>\n<mml:mn>1<\/mml:mn>\n<\/mml:mrow>\n<\/mml:msup>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> feature with the thickness squared, <jats:inline-formula><jats:alternatives><jats:tex-math>$$d^2$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msup>\n<mml:mi>d<\/mml:mi>\n<mml:mn>2<\/mml:mn>\n<\/mml:msup>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula>, is first established using analytical solutions, and the calibration is carried out using the feature values obtained in air and the reference signal. The performance of this technique is assessed and compared with the conventional <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\tau _0$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msub>\n<mml:mi>\u03c4<\/mml:mi>\n<mml:mn>0<\/mml:mn>\n<\/mml:msub>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> technique. Although both features exhibit similar immunity towards lift-off, <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\tau _0$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msub>\n<mml:mi>\u03c4<\/mml:mi>\n<mml:mn>0<\/mml:mn>\n<\/mml:msub>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> technique requires normalisation procedure, which contributes to determining more configuration parameters. Experimental results also suggest the relative advantage of using <jats:inline-formula><jats:alternatives><jats:tex-math>$$|\\nabla |^{-1}$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n<mml:msup>\n<mml:mrow>\n<mml:mo>|<\/mml:mo>\n<mml:mi>\u2207<\/mml:mi>\n<mml:mo>|<\/mml:mo>\n<\/mml:mrow>\n<mml:mrow>\n<mml:mo>-<\/mml:mo>\n<mml:mn>1<\/mml:mn>\n<\/mml:mrow>\n<\/mml:msup>\n<\/mml:math><\/jats:alternatives><\/jats:inline-formula> feature in both wall thickness estimation and influences of noises.<\/jats:p>","DOI":"10.1007\/s10921-020-00699-w","type":"journal-article","created":{"date-parts":[[2020,6,30]],"date-time":"2020-06-30T05:13:22Z","timestamp":1593494002000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Pulsed Eddy Current: Feature Extraction Enabling In-Situ Calibration and Improved Estimation for Ferromagnetic Application"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4081-4493","authenticated-orcid":false,"given":"Faris","family":"Nafiah","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad O.","family":"Tokhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiva","family":"Majidnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Rudlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhanfang","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Duan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,30]]},"reference":[{"key":"699_CR1","volume-title":"Modelling and Inversion of Pulsed Eddy Current Data [Dissertation]","author":"S van den Berg","year":"2003","unstructured":"van den Berg, S.: Modelling and Inversion of Pulsed Eddy Current Data [Dissertation]. Delft University of Technology, Delft (2003)"},{"key":"699_CR2","unstructured":"De Haan, V.O., De Jong, P.A.: Simultaneous measurement of material properties and thickness of carbon steel plates using pulsed eddy currents. In: 16th World Conference on Non-Destructive Testing, Aug 30\u2013Sep 3, 2004, Montreal, Canada (2004)"},{"key":"699_CR3","unstructured":"Eddy, I.C., Underhill, P.R., Morelli, J., et al.: Pulsed eddy current response to general corrosion in concrete bar. In: 2019 NDT in Canada, June 18\u201320, Alberta, Canada (2019)"},{"key":"699_CR4","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.ndteint.2012.07.004","volume":"51","author":"Z Xu","year":"2012","unstructured":"Xu, Z., Wu, X., Li, J., et al.: Assessment of wall thinning in insulated ferromagnetic pipes using the time-to-peak of differential pulsed eddy-current testing signals. NDT & E Int. 51, 24\u201329 (2012)","journal-title":"NDT & E Int."},{"key":"699_CR5","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.ndteint.2010.11.001","volume":"44","author":"C Huang","year":"2011","unstructured":"Huang, C., Wu, X., Xu, Z., et al.: Ferromagnetic material pulsed eddy current testing signal modeling by equivalent multiple-coil-coupling approach. NDT & E Int. 44, 163\u2013168 (2011)","journal-title":"NDT & E Int."},{"key":"699_CR6","doi-asserted-by":"crossref","unstructured":"Ulapane, N., Nguyen, L., Miro, J.V., et\u00a0al.: Designing a pulsed eddy current sensing set-up for cast iron thickness assessment. In: Proceedings of the 2017 12th IEEE Conference on Industrial Electronics and Applications, ICIEA 2017, pp. 901\u2013906 (2018)","DOI":"10.1109\/ICIEA.2017.8282967"},{"key":"699_CR7","doi-asserted-by":"publisher","first-page":"2208","DOI":"10.3390\/s17102208","volume":"17","author":"N Ulapane","year":"2017","unstructured":"Ulapane, N., Alempijevic, A., Calleja, T.V., et al.: Pulsed eddy current sensing for critical pipe condition assessment. Sensors 17, 2208\u20132233 (2017)","journal-title":"Sensors"},{"key":"699_CR8","doi-asserted-by":"publisher","first-page":"470","DOI":"10.3390\/electronics8050470","volume":"8","author":"N Ulapane","year":"2019","unstructured":"Ulapane, N., Nguyen, L.: Review of pulsed-eddy-current signal feature-extraction methods for conductive ferromagnetic material-thickness quantification. Electronics 8, 470\u2013482 (2019)","journal-title":"Electronics"},{"key":"699_CR9","unstructured":"Buck, J.A., Kramer, C., Lei, J., et\u00a0al.: Field implementation of a transient eddy current system for carbon steel pipe thickness measurements. In: 6th International CANDU In-Service Inspection Workshop, November\u00a015\u201317, 2016, Ontario, Canada (2016)"},{"key":"699_CR10","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.ndteint.2018.08.003","volume":"100","author":"N Ulapane","year":"2018","unstructured":"Ulapane, N., Alempijevic, A., Miro, J.V., et al.: Non-destructive evaluation of ferromagnetic material thickness using pulsed eddy current sensor detector coil voltage decay rate. NDT & E Int. 100, 108\u2013114 (2018)","journal-title":"NDT & E Int."},{"key":"699_CR11","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.ndteint.2014.09.006","volume":"69","author":"C Huang","year":"2015","unstructured":"Huang, C., Wu, X.: An improved ferromagnetic material pulsed eddy current testing signal processing method based on numerical cumulative integration. NDT & E Int. 69, 35\u201339 (2015)","journal-title":"NDT & E Int."},{"key":"699_CR12","unstructured":"Kitane, Y., Ando, S., Itoh, Y., et\u00a0al.: Numerical study on pulsed eddy current thickness measurement for steel plates with thickness loss. In: Proceedings of the Fourteenth East Asia-Pacific Conference on Structural Engineering and Construction, pp. 1\u20138 (2016)"},{"key":"699_CR13","unstructured":"20669:2017(E)\u00a0I. Non-destructve testing\u2014pulsed eddy current testing of ferromagnetic metallic components. International Organization for Standardization, Geneva (2017)"}],"container-title":["Journal of Nondestructive Evaluation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10921-020-00699-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10921-020-00699-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10921-020-00699-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,29]],"date-time":"2021-06-29T23:36:04Z","timestamp":1625009764000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10921-020-00699-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,30]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["699"],"URL":"https:\/\/doi.org\/10.1007\/s10921-020-00699-w","relation":{},"ISSN":["0195-9298","1573-4862"],"issn-type":[{"value":"0195-9298","type":"print"},{"value":"1573-4862","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,30]]},"assertion":[{"value":"14 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"52"}}