{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T16:21:13Z","timestamp":1772554873393,"version":"3.50.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T00:00:00Z","timestamp":1762905600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T00:00:00Z","timestamp":1762905600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Protein J"],"DOI":"10.1007\/s10930-025-10303-7","type":"journal-article","created":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T14:33:54Z","timestamp":1762958034000},"page":"178-184","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Challenges in Serum Albumin Measurements: A Comparative Study of the Bromocresol Green and the Capillary Zone Electrophoretic Method"],"prefix":"10.1007","volume":"45","author":[{"given":"Mariem","family":"Othmani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yessine","family":"Amri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siwar","family":"Chelbi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sondes","family":"Hadj Fredj","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taieb","family":"Messaoud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rym","family":"Dabboubi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,12]]},"reference":[{"issue":"2","key":"10303_CR1","doi-asserted-by":"publisher","DOI":"10.3892\/mmr.2023.13147","volume":"29","author":"N Wu","year":"2024","unstructured":"Wu N, Liu T, Tian M, Liu C, Ma S, Cao H, Bian H, Wang L, Feng Y, Qi J (2024) Albumin, an interesting and functionally diverse protein, varies from \u2018native\u2019 to \u2018effective\u2019 (review). Mol Med Rep 29(2):24. https:\/\/doi.org\/10.3892\/mmr.2023.13147","journal-title":"Mol Med Rep"},{"key":"10303_CR2","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.cca.2018.10.009","volume":"487","author":"M Padelli","year":"2018","unstructured":"Padelli M, Leven C, Le Reun E, Labouret T, Galakhoff N, Labarre M, Rouill\u00e9 A, Kerspern H, Lap\u00e8gue M, Chauvet J, Pl\u00e9e-Gautier E, Carr\u00e9 JL (2018) Is capillary zone electrophoresis a suitable method for estimating serum albumin: a comparison of four methods. Clin Chim Acta 487:250\u2013255. https:\/\/doi.org\/10.1016\/j.cca.2018.10.009","journal-title":"Clin Chim Acta"},{"issue":"4","key":"10303_CR3","doi-asserted-by":"publisher","first-page":"4081","DOI":"10.3390\/ijms24044081","volume":"24","author":"A di Masi","year":"2023","unstructured":"di Masi A (2023) Human serum albumin: from molecular aspects to biotechnological applications. Int J Mol Sci 24(4):4081. https:\/\/doi.org\/10.3390\/ijms24044081","journal-title":"Int J Mol Sci"},{"key":"10303_CR4","doi-asserted-by":"publisher","DOI":"10.21037\/jlpm-22-33","volume":"7","author":"E Gernez","year":"2022","unstructured":"Gernez E, Grzych G (2022) Over what albumin concentration range are adjusted calcium equations valid? J Lab Precis Med 7:28. https:\/\/doi.org\/10.21037\/jlpm-22-33","journal-title":"J Lab Precis Med"},{"issue":"Pt 1","key":"10303_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijbiomac.2024.131132","volume":"266","author":"A Jahanban-Esfahlan","year":"2024","unstructured":"Jahanban-Esfahlan A, Amarowicz R (2024) Molecularly imprinted polymers for sensing\/depleting human serum albumin (HSA): a critical review of recent advances and current challenges. Int J Biol Macromol 266(Pt 1):131132. https:\/\/doi.org\/10.1016\/j.ijbiomac.2024.131132","journal-title":"Int J Biol Macromol"},{"issue":"4","key":"10303_CR6","first-page":"104","volume":"29","author":"A Boufamma","year":"2021","unstructured":"Boufamma A, Hamma A, Benatallah A (2021) Etude de concordance des mesures d\u2019albumine par l\u2019electrophorese capillaire et le vert de bromocresol. J Alger Med 29(4):104\u2013107","journal-title":"J Alger Med"},{"issue":"Suppl 4","key":"10303_CR7","doi-asserted-by":"publisher","first-page":"s18","DOI":"10.2450\/2013.005s","volume":"11","author":"P Caraceni","year":"2013","unstructured":"Caraceni P, Tufoni M, Bonavita ME (2013) Clinical use of albumin. Blood Transfus 11(Suppl 4):s18\u2013s25. https:\/\/doi.org\/10.2450\/2013.005s","journal-title":"Blood Transfus"},{"key":"10303_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijbiomac.2024.138593","volume":"287","author":"A Jahanban-Esfahlan","year":"2025","unstructured":"Jahanban-Esfahlan A, Amarowicz R (2025) Optical sensing of albumin in human serum and urine-a historical review of the transition from classical dye-binding assays to advanced technologies. Int J Biol Macromol 287:138593. https:\/\/doi.org\/10.1016\/j.ijbiomac.2024.138593","journal-title":"Int J Biol Macromol"},{"issue":"9\u201310","key":"10303_CR9","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.cca.2011.01.008","volume":"412","author":"I Infusino","year":"2011","unstructured":"Infusino I, Braga F, Mozzi R, Valente C, Panteghini M (2011) Is the accuracy of serum albumin measurements suitable for clinical application of the test? Clin Chim Acta 412(9\u201310):791\u2013792. https:\/\/doi.org\/10.1016\/j.cca.2011.01.008","journal-title":"Clin Chim Acta"},{"issue":"Pt 1","key":"10303_CR10","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1177\/0004563215574350","volume":"53","author":"T Ueno","year":"2016","unstructured":"Ueno T, Hirayama S, Sugihara M, Miida T (2016) The bromocresol green assay, but not the modified bromocresol purple assay, overestimates the serum albumin concentration in nephrotic syndrome through reaction with \u03b12-macroglobulin. Ann Clin Biochem 53(Pt 1):97\u2013105. https:\/\/doi.org\/10.1177\/0004563215574350","journal-title":"Ann Clin Biochem"},{"issue":"10","key":"10303_CR11","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1136\/jcp.56.10.780","volume":"56","author":"EB Duly","year":"2003","unstructured":"Duly EB, Grimason S, Grimason P, Barnes G, Trinick TR (2003) Measurement of serum albumin by capillary zone electrophoresis, bromocresol green, bromocresol purple, and immunoassay methods. J Clin Pathol 56(10):780\u2013781. https:\/\/doi.org\/10.1136\/jcp.56.10.780","journal-title":"J Clin Pathol"},{"issue":"3","key":"10303_CR12","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1684\/abc.2017.1239","volume":"75","author":"A Rossary","year":"2017","unstructured":"Rossary A, Blond\u00e9-Cynober F, Bastard JP, Beauvieux MC, Beyne P, Drai J, Lombard C, Anglard I, Aussel C, Claeyssens S, Vasson MP (2017) Determination of serum albumin, analytical challenges: a French multicenter study. Albumin\u00e9mie: les enjeux analytiques dans le cadre de l\u2019\u00e9valuation nutritionnelle. \u00c9tude comparative multicentrique fran\u00e7aise. Ann Biol Clin 75(3):305\u2013318. https:\/\/doi.org\/10.1684\/abc.2017.1239","journal-title":"Ann Biol Clin"},{"key":"10303_CR13","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.cca.2017.04.007","volume":"469","author":"D Kumar","year":"2017","unstructured":"Kumar D, Banerjee D (2017) Methods of albumin estimation in clinical biochemistry: past, present, and future. Clin Chim Acta 469:150\u2013160. https:\/\/doi.org\/10.1016\/j.cca.2017.04.007","journal-title":"Clin Chim Acta"},{"issue":"5","key":"10303_CR14","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1002\/jcla.21921","volume":"30","author":"J Helmersson-Karlqvist","year":"2016","unstructured":"Helmersson-Karlqvist J, Flodin M, Havelka AM, Xu XY, Larsson A (2016) The roche immunoturbidimetric albumin method on Cobas c 501 gives higher values than the Abbott and roche BCP methods when analyzing patient plasma samples. J Clin Lab Anal 30(5):677\u2013681. https:\/\/doi.org\/10.1002\/jcla.21921","journal-title":"J Clin Lab Anal"}],"container-title":["The Protein Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10930-025-10303-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10930-025-10303-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10930-025-10303-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T14:00:58Z","timestamp":1772546458000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10930-025-10303-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,12]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["10303"],"URL":"https:\/\/doi.org\/10.1007\/s10930-025-10303-7","relation":{},"ISSN":["1875-8355"],"issn-type":[{"value":"1875-8355","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,12]]},"assertion":[{"value":"17 July 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"The study was approved by the Human Ethics committee of Bechir Hamza Children\u2019s Hospital of Tunis, Tunisia. Informed consent was obtained from all participants, or from their parents or legal guardians in the case of minors, prior to inclusion in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval and Consent to Participate"}},{"value":"Written informed consent for publication of their clinical details was obtained from the parents.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}}]}}