{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T05:04:47Z","timestamp":1790139887874,"version":"4.0.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T00:00:00Z","timestamp":1769644800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T00:00:00Z","timestamp":1769644800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Neurooncol"],"published-print":{"date-parts":[[2026,2]]},"DOI":"10.1007\/s11060-025-05408-z","type":"journal-article","created":{"date-parts":[[2026,1,29]],"date-time":"2026-01-29T09:11:03Z","timestamp":1769677863000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Carbon fiber-reinforced polyetheretherketone implants versus titanium implants for spinal tumors: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"176","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-0797-8439","authenticated-orcid":false,"given":"Zheting","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheqing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lester","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,29]]},"reference":[{"key":"5408_CR1","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.nec.2004.04.018","volume":"15","author":"RG Perrin","year":"2004","unstructured":"Perrin RG, Laxton AW (2004) Metastatic spine disease: epidemiology, pathophysiology, and evaluation of patients. Neurosurg Clin N Am 15:365\u2013373. https:\/\/doi.org\/10.1016\/j.nec.2004.04.018","journal-title":"Neurosurg Clin N Am"},{"key":"5408_CR2","doi-asserted-by":"publisher","first-page":"108S","DOI":"10.1177\/2192568219828727","volume":"9","author":"R Charest-Morin","year":"2019","unstructured":"Charest-Morin R, Fisher CG, Sahgal A, Boriani S, Gokaslan ZL, Lazary A, Reynolds J, Bettegowda C, Rhines LD, Dea N (2019) Primary bone tumor of the spine-an evolving field: what a general spine surgeon should know. Global Spine J 9:108S\u2013116S. https:\/\/doi.org\/10.1177\/2192568219828727","journal-title":"Global Spine J"},{"key":"5408_CR3","doi-asserted-by":"publisher","first-page":"321","DOI":"10.4081\/oncol.2017.321","volume":"11","author":"F Macedo","year":"2017","unstructured":"Macedo F, Ladeira K, Pinho F, Saraiva N, Bonito N, Pinto L, Goncalves F (2017) Bone metastases: an overview. Oncol Rev 11:321. https:\/\/doi.org\/10.4081\/oncol.2017.321","journal-title":"Oncol Rev"},{"key":"5408_CR4","doi-asserted-by":"publisher","first-page":"100446","DOI":"10.1016\/j.jbo.2022.100446","volume":"35","author":"R Van den Brande","year":"2022","unstructured":"Van den Brande R, Cornips EM, Peeters M, Ost P, Billiet C, Van de Kelft E (2022) Epidemiology of spinal metastases, metastatic epidural spinal cord compression and pathologic vertebral compression fractures in patients with solid tumors: a systematic review. J Bone Oncol 35:100446. https:\/\/doi.org\/10.1016\/j.jbo.2022.100446","journal-title":"J Bone Oncol"},{"key":"5408_CR5","doi-asserted-by":"publisher","first-page":"i5","DOI":"10.1093\/nop\/npaa046","volume":"7","author":"JT Wewel","year":"2020","unstructured":"Wewel JT, O\u2019Toole JE (2020) Epidemiology of spinal cord and column tumors. Neurooncol Pract 7:i5\u2013i9. https:\/\/doi.org\/10.1093\/nop\/npaa046","journal-title":"Neurooncol Pract"},{"key":"5408_CR6","doi-asserted-by":"publisher","first-page":"7988","DOI":"10.1038\/s41598-021-87121-1","volume":"11","author":"A Wagner","year":"2021","unstructured":"Wagner A, Haag E, Joerger AK, Jost P, Combs SE, Wostrack M, Gempt J, Meyer B (2021) Comprehensive surgical treatment strategy for spinal metastases. Sci Rep 11:7988. https:\/\/doi.org\/10.1038\/s41598-021-87121-1","journal-title":"Sci Rep"},{"key":"5408_CR7","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1016\/s0140-6736(05)66954-1","volume":"366","author":"RA Patchell","year":"2005","unstructured":"Patchell RA, Tibbs PA, Regine WF, Payne R, Saris S, Kryscio RJ, Mohiuddin M, Young B (2005) Direct decompressive surgical resection in the treatment of spinal cord compression caused by metastatic cancer: a randomised trial. Lancet 366:643\u2013648. https:\/\/doi.org\/10.1016\/s0140-6736(05)66954-1","journal-title":"Lancet"},{"key":"5408_CR8","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1002\/acm2.12046","volume":"18","author":"A Nevelsky","year":"2017","unstructured":"Nevelsky A, Borzov E, Daniel S, Bar-Deroma R (2017) Perturbation effects of the carbon fiber-PEEK screws on radiotherapy dose distribution. J Appl Clin Med Phys 18:62\u201368. https:\/\/doi.org\/10.1002\/acm2.12046","journal-title":"J Appl Clin Med Phys"},{"key":"5408_CR9","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.radonc.2021.08.007","volume":"163","author":"N Kumar","year":"2021","unstructured":"Kumar N, Lopez KG, Alathur Ramakrishnan S, Hallinan J, Fuh JYH, Pandita N, Madhu S, Kumar A, Benneker LM, Vellayappan BA (2021) Evolution of materials for implants in metastatic spine disease till date - have we found an ideal material? Radiother Oncol 163:93\u2013104. https:\/\/doi.org\/10.1016\/j.radonc.2021.08.007","journal-title":"Radiother Oncol"},{"key":"5408_CR10","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera S, Ghermandi R, Boriani S (2017) Composite PEEK\/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg 3:323\u2013329. https:\/\/doi.org\/10.21037\/jss.2017.06.20","journal-title":"J Spine Surg"},{"key":"5408_CR11","doi-asserted-by":"publisher","first-page":"603","DOI":"10.14444\/8685","volume":"18","author":"N Kumar","year":"2024","unstructured":"Kumar N, Kumar P, Zihui GL, Seow L, Liang S, Hui SJ, Parihar R, Hallinan J, Vellayappan B, Tan JHJ (2024) Nonmetallic carbon fiber-reinforced polyetheretherketone implants vs titanium implants: analysis of clinical outcomes and influence on postoperative radiotherapy planning in metastatic spine tumor surgery. Int J Spine Surg 18:603\u2013610. https:\/\/doi.org\/10.14444\/8685","journal-title":"Int J Spine Surg"},{"key":"5408_CR12","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1007\/s00586-017-5258-5","volume":"27","author":"S Boriani","year":"2018","unstructured":"Boriani S, Tedesco G, Ming L, Ghermandi R, Amichetti M, Fossati P, Krengli M, Mavilla L, Gasbarrini A (2018) Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report. Eur Spine J 27:874\u2013881. https:\/\/doi.org\/10.1007\/s00586-017-5258-5","journal-title":"Eur Spine J"},{"key":"5408_CR13","doi-asserted-by":"publisher","first-page":"317","DOI":"10.14245\/ns.2244920.460","volume":"20","author":"C Alvarez-Breckenridge","year":"2023","unstructured":"Alvarez-Breckenridge C, de Almeida R, Haider A, Muir M, Bird J, North R, Rhines L, Tatsui C (2023) Carbon fiber-reinforced polyetheretherketone spinal implants for treatment of spinal tumors: perceived advantages and limitations. Neurospine 20:317\u2013326. https:\/\/doi.org\/10.14245\/ns.2244920.460","journal-title":"Neurospine"},{"key":"5408_CR14","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.wneu.2017.04.091","volume":"105","author":"F Ringel","year":"2017","unstructured":"Ringel F, Ryang YM, Kirschke JS, M\u00fcller BS, Wilkens JJ, Brodard J, Combs SE, Meyer B (2017) Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg 105:294\u2013301. https:\/\/doi.org\/10.1016\/j.wneu.2017.04.091","journal-title":"World Neurosurg"},{"key":"5408_CR15","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.wneu.2021.04.068","volume":"151","author":"M Muther","year":"2021","unstructured":"Muther M, Luthge S, Gerwing M, Stummer W, Schwake M (2021) Management of spinal dumbbell tumors via a minimally invasive posterolateral approach and carbon fiber-reinforced polyether ether ketone instrumentation: technical note and surgical case series. World Neurosurg 151:277\u2013283 e271. https:\/\/doi.org\/10.1016\/j.wneu.2021.04.068","journal-title":"World Neurosurg"},{"key":"5408_CR16","doi-asserted-by":"publisher","first-page":"E13","DOI":"10.3171\/2021.2.FOCUS20995","volume":"50","author":"MT Neal","year":"2021","unstructured":"Neal MT, Richards AE, Curley KL, Patel NP, Ashman JB, Vora SA, Kalani MA (2021) Carbon fiber-reinforced PEEK instrumentation in the spinal oncology population: a retrospective series demonstrating technique, feasibility, and clinical outcomes. Neurosurg Focus 50:E13. https:\/\/doi.org\/10.3171\/2021.2.FOCUS20995","journal-title":"Neurosurg Focus"},{"key":"5408_CR17","doi-asserted-by":"publisher","first-page":"e536","DOI":"10.1016\/j.wneu.2021.07.092","volume":"154","author":"A Wagner","year":"2021","unstructured":"Wagner A, Haag E, Joerger AK, Gempt J, Krieg SM, Wostrack M, Meyer B (2021) Cement-augmented carbon fiber-reinforced pedicle screw instrumentation for spinal metastases: safety and efficacy. World Neurosurg 154:e536\u2013e546. https:\/\/doi.org\/10.1016\/j.wneu.2021.07.092","journal-title":"World Neurosurg"},{"key":"5408_CR18","doi-asserted-by":"publisher","unstructured":"Joerger AK, Seitz S, Lange N, Aftahy AK, Wagner A, Ryang YM, Bernhardt D, Combs SE, Wostrack M, Gempt J, Meyer B (2022) CFR-PEEK pedicle screw instrumentation for spinal neoplasms: a single center experience on safety and efficacy. Cancers (Basel) 14. https:\/\/doi.org\/10.3390\/cancers14215275","DOI":"10.3390\/cancers14215275"},{"key":"5408_CR19","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/BRS.0000000000004177","volume":"47","author":"FH Shen","year":"2022","unstructured":"Shen FH, Gasbarrini A, Lui DF, Reynolds J, Capua J, Boriani S (2022) Integrated custom composite polyetheretherketone\/carbon fiber (PEEK\/CF) vertebral body replacement (VBR) in the treatment of bone tumors of the spine: a preliminary report from a multicenter study. Spine (Phila Pa 1976) 47:252\u2013260. https:\/\/doi.org\/10.1097\/BRS.0000000000004177","journal-title":"Spine (phila Pa 1976)"},{"key":"5408_CR20","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1007\/s00701-023-05502-z","volume":"165","author":"M Schwendner","year":"2023","unstructured":"Schwendner M, Ille S, Kirschke JS, Bernhardt D, Combs SE, Meyer B, Krieg SM (2023) Clinical evaluation of vertebral body replacement of carbon fiber-reinforced polyetheretherketone in patients with tumor manifestation of the thoracic and lumbar spine. Acta Neurochir (Wien) 165:897\u2013904. https:\/\/doi.org\/10.1007\/s00701-023-05502-z","journal-title":"Acta Neurochir (Wien)"},{"key":"5408_CR21","doi-asserted-by":"publisher","unstructured":"Hubertus V, Wagner A, Albrecht C, Kalasauskas D, Jankovic D, Turgut M, Lener S, Gmeiner R, Miller H, Brusseler MMT, Acker G, Hecht N, Onken JS, Combs SE, Thome C, Ringel F, Vajkoczy P, Meyer B (2025) Carbon fiber-reinforced PEEK implants in oncologic spine surgery: a multicenter experience on implications for postoperative patient management. J Neurosurg Spine 1\u201310. https:\/\/doi.org\/10.3171\/2024.10.SPINE24753","DOI":"10.3171\/2024.10.SPINE24753"},{"key":"5408_CR22","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.jocn.2020.03.013","volume":"75","author":"F Cofano","year":"2020","unstructured":"Cofano F, Di Perna G, Monticelli M, Marengo N, Ajello M, Mammi M, Vercelli G, Petrone S, Tartara F, Zenga F, Lanotte M, Garbossa D (2020) Carbon fiber reinforced vs titanium implants for fixation in spinal metastases: a comparative clinical study about safety and effectiveness of the new \u201ccarbon-strategy\u201d. J Clin Neurosci 75:106\u2013111. https:\/\/doi.org\/10.1016\/j.jocn.2020.03.013","journal-title":"J Clin Neurosci"},{"key":"5408_CR23","doi-asserted-by":"publisher","unstructured":"Morgen SS, Alfthan Madsen EB, Skive Weiland A, Dahl B, Gehrchen M (2024) Carbon instrumentation in patients with metastatic spinal cord compression. Cancers (Basel) 16. https:\/\/doi.org\/10.3390\/cancers16040736","DOI":"10.3390\/cancers16040736"},{"key":"5408_CR24","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s11060-024-04842-9","volume":"171","author":"J Ward","year":"2025","unstructured":"Ward J, Damante M, Wilson S, Coelho V, Franceschelli D, Elguindy AN, Thomas EM, Zhu S, Blakaj D, Beyer S, Raval R, Singh R, Xu DS, Elder JB, Palmer JD, Chakravarthy VB (2025) Impact of instrumentation material on local recurrence: a case-matched series using carbon fiber-PEEK vs. titanium. J Neurooncol 171:155\u2013162. https:\/\/doi.org\/10.1007\/s11060-024-04842-9","journal-title":"J Neurooncol"},{"key":"5408_CR25","doi-asserted-by":"publisher","first-page":"e1000097","DOI":"10.1371\/journal.pmed.1000097","volume":"6","author":"D Moher","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097. https:\/\/doi.org\/10.1371\/journal.pmed.1000097","journal-title":"PLoS Med"},{"key":"5408_CR26","doi-asserted-by":"publisher","first-page":"i4919","DOI":"10.1136\/bmj.i4919","volume":"355","author":"JA Sterne","year":"2016","unstructured":"Sterne JA, Hern\u00e1n MA, Reeves BC, Savovi\u0107 J, Berkman ND, Viswanathan M, Henry D, Altman DG, Ansari MT, Boutron I, Carpenter JR, Chan AW, Churchill R, Deeks JJ, Hr\u00f3bjartsson A, Kirkham J, J\u00fcni P, Loke YK, Pigott TD, Ramsay CR, Regidor D, Rothstein HR, Sandhu L, Santaguida PL, Sch\u00fcnemann HJ, Shea B, Shrier I, Tugwell P, Turner L, Valentine JC, Waddington H, Waters E, Wells GA, Whiting PF, Higgins JP (2016) ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. Bmj 355:i4919. https:\/\/doi.org\/10.1136\/bmj.i4919","journal-title":"Bmj"},{"key":"5408_CR27","unstructured":"Members of the Cochrane Bias Methods Group and the Cochrane Non-Randomised Studies Methods Group (2025) ROBINS-I V2 tool. https:\/\/www.riskofbias.info\/welcome\/robins-i-v2. Accessed 11 Aug 2025"},{"key":"5408_CR28","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.jclinepi.2010.09.011","volume":"64","author":"GH Guyatt","year":"2011","unstructured":"Guyatt GH, Oxman AD, Sch\u00fcnemann HJ, Tugwell P, Knottnerus A (2011) GRADE guidelines: a new series of articles in the. J Clin Epidemiol 64:380\u2013382. https:\/\/doi.org\/10.1016\/j.jclinepi.2010.09.011","journal-title":"J Clin Epidemiol"},{"key":"5408_CR29","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JP Higgins","year":"2003","unstructured":"Higgins JP, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ 327:557\u2013560. https:\/\/doi.org\/10.1136\/bmj.327.7414.557","journal-title":"BMJ"},{"key":"5408_CR30","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1002\/acm2.12905","volume":"21","author":"BS Muller","year":"2020","unstructured":"Muller BS, Ryang YM, Oechsner M, Dusberg M, Meyer B, Combs SE, Wilkens JJ (2020) The dosimetric impact of stabilizing spinal implants in radiotherapy treatment planning with protons and photons: standard titanium alloy vs. radiolucent carbon-fiber-reinforced PEEK systems. J Appl Clin Med Phys 21:6\u201314. https:\/\/doi.org\/10.1002\/acm2.12905","journal-title":"J Appl Clin Med Phys"},{"key":"5408_CR31","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ejmp.2017.11.008","volume":"44","author":"E Mastella","year":"2017","unstructured":"Mastella E, Molinelli S, Magro G, Mirandola A, Russo S, Vai A, Mairani A, Choi K, Fiore MR, Fossati P, Cuzzocrea F, Gasbarrini A, Benazzo F, Boriani S, Valvo F, Orecchia R, Ciocca M (2017) Dosimetric characterization of carbon fiber stabilization devices for post-operative particle therapy. Phys Med 44:18\u201325. https:\/\/doi.org\/10.1016\/j.ejmp.2017.11.008","journal-title":"Phys Med"},{"key":"5408_CR32","doi-asserted-by":"publisher","first-page":"8","DOI":"10.21037\/jss-23-93","volume":"10","author":"D Ho","year":"2024","unstructured":"Ho D, Corde S, Chen C, Saade G, Betteridge C, Mobbs R (2024) The use of carbon fiber\/polyetheretherketone (CF\/PEEK) in pedicle screw fixation for spinal neoplasms-potential advantages in postoperative imaging and radiotherapy planning. J Spine Surg 10:8\u201321. https:\/\/doi.org\/10.21037\/jss-23-93","journal-title":"J Spine Surg"},{"key":"5408_CR33","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.prro.2023.10.005","volume":"14","author":"de Almeida Raa","year":"2024","unstructured":"de Almeida Raa, Ghia AJ, Amini B, Wang C, Alvarez-Breckenridge CA, Li J, Rhines LD, Tom MC, North RY, Beckham TH, Tatsui CE (2024) Quantification of MRI artifacts in carbon fiber reinforced polyetheretherketone thoracolumbar pedicle screw constructs prior to spinal stereotactic radiosurgery. Pract Radiat Oncol 14:103\u2013111. https:\/\/doi.org\/10.1016\/j.prro.2023.10.005","journal-title":"Pract Radiat Oncol"},{"key":"5408_CR34","doi-asserted-by":"publisher","first-page":"6700","DOI":"10.1038\/s41598-024-52498-2","volume":"14","author":"Z Rijs","year":"2024","unstructured":"Rijs Z, Kawsar KA, Saha P, van de Sande M, Lui D (2024) Evaluation of computed tomography artefacts of carbon-fiber and titanium implants in patients with spinal oligometastatic disease undergoing stereotactic ablative radiotherapy. Sci Rep 14:6700. https:\/\/doi.org\/10.1038\/s41598-024-52498-2","journal-title":"Sci Rep"},{"key":"5408_CR35","doi-asserted-by":"publisher","unstructured":"Cost\u0103chescu B, Niculescu AG, Iliescu BF, Dabija MG, Grumezescu AM, Rotariu D (2022) Current and emerging approaches for spine tumor treatment. Int J Mol Sci 23. https:\/\/doi.org\/10.3390\/ijms232415680","DOI":"10.3390\/ijms232415680"},{"key":"5408_CR36","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s10143-020-01384-2","volume":"44","author":"T Kratzig","year":"2021","unstructured":"Kratzig T, Mende KC, Mohme M, Kniep H, Dreimann M, Stangenberg M, Westphal M, Gauer T, Eicker SO (2021) Carbon fiber-reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev 44:2163\u20132170. https:\/\/doi.org\/10.1007\/s10143-020-01384-2","journal-title":"Neurosurg Rev"},{"key":"5408_CR37","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.wneu.2023.01.090","volume":"173","author":"RJ Perez-Roman","year":"2023","unstructured":"Perez-Roman RJ, Boddu JV, Bashti M, Bryant JP, Amadasu E, Gyedu JS, Wang MY (2023) The use of carbon fiber-reinforced instrumentation in patients with spinal oncologic tumors: a systematic review of literature and future directions. World Neurosurg 173:13\u201322. https:\/\/doi.org\/10.1016\/j.wneu.2023.01.090","journal-title":"World Neurosurg"},{"key":"5408_CR38","doi-asserted-by":"publisher","first-page":"163","DOI":"10.21037\/jss.2017.05.01","volume":"3","author":"RF Heary","year":"2017","unstructured":"Heary RF, Parvathreddy N, Sampath S, Agarwal N (2017) Elastic modulus in the selection of interbody implants. J Spine Surg 3:163\u2013167. https:\/\/doi.org\/10.21037\/jss.2017.05.01","journal-title":"J Spine Surg"},{"key":"5408_CR39","doi-asserted-by":"crossref","unstructured":"Kurtz SM (2012) An overview of PEEK biomaterials. PEEK biomaterials handbook 1\u20137","DOI":"10.1016\/B978-1-4377-4463-7.10001-6"},{"key":"5408_CR40","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.bmt.2023.11.002","volume":"6","author":"G Sacks","year":"2024","unstructured":"Sacks G, Shah V, Yao L, Yan C, Shah D, Limeta L, DeStefano V (2024) Polyaryletherketones: properties and applications in modern medicine. Biomed Technol 6:75\u201389. https:\/\/doi.org\/10.1016\/j.bmt.2023.11.002","journal-title":"Biomed Technol"},{"key":"5408_CR41","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.biomaterials.2005.07.011","volume":"27","author":"JM Toth","year":"2006","unstructured":"Toth JM, Wang M, Estes BT, Scifert JL, Seim HB, Turner AS (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27:324\u2013334. https:\/\/doi.org\/10.1016\/j.biomaterials.2005.07.011","journal-title":"Biomaterials"},{"key":"5408_CR42","doi-asserted-by":"publisher","first-page":"e44307","DOI":"10.7759\/cureus.44307","volume":"15","author":"S Moharil","year":"2023","unstructured":"Moharil S, Reche A, Durge K (2023) Polyetheretherketone (PEEK) as a biomaterial: an overview. Cureus 15:e44307. https:\/\/doi.org\/10.7759\/cureus.44307","journal-title":"Cureus"},{"key":"5408_CR43","doi-asserted-by":"publisher","first-page":"836","DOI":"10.31616\/asj.2025.0040","volume":"19","author":"N Kumar","year":"2025","unstructured":"Kumar N, Hui SJ, Kumar P, Gabriel LZ, Parihar R, Tan JH, Yang YO, Ryang YM (2025) Carbon-fiber-reinforced polyetheretherketone instrumentation in metastatic spine tumor surgery: technical considerations and potential pitfalls to avoid. Asian Spine J 19:836\u2013846. https:\/\/doi.org\/10.31616\/asj.2025.0040","journal-title":"Asian Spine J"},{"key":"5408_CR44","doi-asserted-by":"publisher","first-page":"100105","DOI":"10.1016\/j.xnsj.2022.100105","volume":"10","author":"AG Zavras","year":"2022","unstructured":"Zavras AG, Schoenfeld AJ, Patt JC, Munim MA, Goodwin CR, Goodwin ML, Lo SL, Redmond KJ, Tobert DG, Shin JH, Ferrone ML, Laufer I, Saifi C, Buchowski JM, Jennings JW, Ozturk AK, Huang-Wright C, Mesfin A, Steyn C, Hsu W, Soliman HM, Krishnaney AA, Sciubba DM, Schwab JH, Colman MW (2022) Attitudes and trends in the use of radiolucent spinal implants: a survey of the North American Spine Society section of spinal oncology. N Am Spine Soc J 10:100105. https:\/\/doi.org\/10.1016\/j.xnsj.2022.100105","journal-title":"N Am Spine Soc J"},{"key":"5408_CR45","unstructured":"Krystkiewicz K, Tosik M (2023) Carbon fiber transpedicular screws in treatment of spinal metastatic disease (CarboMetaspine) [Clinical trial]. Copernicus Memorial Hospital. https:\/\/clinicaltrials.gov\/study\/NCT06293157. Accessed 11 Aug 2025"}],"container-title":["Journal of Neuro-Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11060-025-05408-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11060-025-05408-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11060-025-05408-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T10:47:38Z","timestamp":1772102858000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11060-025-05408-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,29]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["5408"],"URL":"https:\/\/doi.org\/10.1007\/s11060-025-05408-z","relation":{},"ISSN":["0167-594X","1573-7373"],"issn-type":[{"value":"0167-594X","type":"print"},{"value":"1573-7373","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,29]]},"assertion":[{"value":"13 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This is a systematic review and meta-analysis. No ethical approval was required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human ethics and consent to participate declarations"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}},{"value":"The authors declare no competing interests.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"189"}}