{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T19:10:32Z","timestamp":1770491432438,"version":"3.49.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T00:00:00Z","timestamp":1567123200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T00:00:00Z","timestamp":1567123200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Urol Nephrol"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1007\/s11255-019-02268-1","type":"journal-article","created":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T06:07:35Z","timestamp":1567145255000},"page":"1841-1847","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Reversed connection of cuffed, tunneled, dual-lumen catheters with increased blood flow rate maintains the adequacy of delivered dialysis despite the higher access recirculation"],"prefix":"10.1007","volume":"51","author":[{"given":"Varvara","family":"Kousoula","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Panagiotis I.","family":"Georgianos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Konstantinos","family":"Mavromatidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christos","family":"Syrganis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elias","family":"Thodis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stylianos","family":"Panagoutsos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ploumis","family":"Passadakis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,8,30]]},"reference":[{"key":"2268_CR1","doi-asserted-by":"publisher","first-page":"S137","DOI":"10.1016\/S0272-6386(01)70007-8","volume":"37","author":"National Kidney Foundation","year":"2001","unstructured":"National Kidney Foundation (2001) K\/DOQI Clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 37:S137\u2013S181","journal-title":"Am J Kidney Dis"},{"issue":"6","key":"2268_CR2","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1053\/j.ajkd.2014.12.014","volume":"65","author":"RL Pisoni","year":"2015","unstructured":"Pisoni RL, Zepel L, Port FK, Robinson BM (2015) Trends in US vascular access use, patient preferences, and related practices: an update from the US DOPPS practice monitor with international comparisons. Am J Kidney Dis 65(6):905\u2013915","journal-title":"Am J Kidney Dis"},{"issue":"8","key":"2268_CR3","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1001\/jamasurg.2015.1126","volume":"150","author":"DS Zarkowsky","year":"2015","unstructured":"Zarkowsky DS, Hicks CW, Arhuidese I, Canner JK, Obeid T, Qazi U et al (2015) Quality improvement targets for regional variation in surgical end-stage renal disease care. JAMA Surg 150(8):764\u2013770","journal-title":"JAMA Surg"},{"issue":"7","key":"2268_CR4","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.2215\/CJN.01690213","volume":"8","author":"CE Lok","year":"2013","unstructured":"Lok CE, Foley R (2013) Vascular access morbidity and mortality: trends of the last decade. Clin J Am Soc Nephrol 8(7):1213\u20131219","journal-title":"Clin J Am Soc Nephrol"},{"issue":"1","key":"2268_CR5","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1159\/000490624","volume":"48","author":"S Shah","year":"2018","unstructured":"Shah S, Leonard AC, Meganathan K, Christianson AL, Thakar CV (2018) gender and racial disparities in initial hemodialysis access and outcomes in incident end-stage renal disease patients. Am J Nephrol 48(1):4\u201314","journal-title":"Am J Nephrol"},{"issue":"7","key":"2268_CR6","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.2215\/CJN.00960113","volume":"8","author":"VD Niyyar","year":"2013","unstructured":"Niyyar VD, Chan MR (2013) Interventional nephrology: catheter dysfunction\u2013prevention and troubleshooting. Clin J Am Soc Nephrol 8(7):1234\u20131243","journal-title":"Clin J Am Soc Nephrol"},{"issue":"2","key":"2268_CR7","first-page":"91","volume":"2","author":"A Atapour","year":"2008","unstructured":"Atapour A, Mosakazemi M, Mortazavi M, Beigi A, Shahidi S (2008) Access recirculation in jugular venous catheter in regular and reversed lines. Iran J Kidney Dis 2(2):91\u201394","journal-title":"Iran J Kidney Dis"},{"issue":"5","key":"2268_CR8","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1053\/j.ajkd.2005.01.029","volume":"45","author":"RC Carson","year":"2005","unstructured":"Carson RC, Kiaii M, MacRae JM (2005) Urea clearance in dysfunctional catheters is improved by reversing the line position despite increased access recirculation. Am J Kidney Dis 45(5):883\u2013890","journal-title":"Am J Kidney Dis"},{"issue":"3","key":"2268_CR9","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/00002480-200205000-00019","volume":"48","author":"HA Hassan","year":"2002","unstructured":"Hassan HA, Frenchie DL, Bastani B (2002) Effect of reversal of catheter ports on recirculation: comparison of the PermCath with Tesio Twin Catheter. ASAIO J 48(3):316\u2013319","journal-title":"ASAIO J"},{"issue":"2","key":"2268_CR10","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1159\/000047007","volume":"20","author":"C Level","year":"2002","unstructured":"Level C, Lasseur C, Chauveau P, Bonarek H, Perrault L, Combe C (2002) Performance of twin central venous catheters: influence of the inversion of inlet and outlet on recirculation. Blood Purif 20(2):182\u2013188","journal-title":"Blood Purif"},{"issue":"2","key":"2268_CR11","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/01.mat.0000202081.13974.39","volume":"52","author":"N Pannu","year":"2006","unstructured":"Pannu N, Jhangri GS, Tonelli M (2006) Optimizing dialysis delivery in tunneled dialysis catheters. ASAIO J 52(2):157\u2013162","journal-title":"ASAIO J"},{"issue":"1","key":"2268_CR12","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1159\/000187457","volume":"65","author":"K Sombolos","year":"1993","unstructured":"Sombolos K, Natse T, Zoumbaridis N, Mavromatidis K, Karagianni A, Fitili C (1993) Efficacy of dual lumen jugular venous catheter hemodialysis when venous lumen is used as arterial lumen. Nephron 65(1):147\u2013149","journal-title":"Nephron"},{"issue":"1","key":"2268_CR13","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1097\/01.MAT.0000104825.33101.7C","volume":"50","author":"L Senecal","year":"2004","unstructured":"Senecal L, Saint-Sauveur E, Leblanc M (2004) Blood flow and recirculation rates in tunneled hemodialysis catheters. ASAIO J 50(1):94\u201397","journal-title":"ASAIO J"},{"issue":"3","key":"2268_CR14","doi-asserted-by":"publisher","first-page":"338","DOI":"10.5301\/JN.2011.6421","volume":"24","author":"BW Van","year":"2011","unstructured":"Van BW, Vanmassenhove J, Van CK, Vanholder R, Eloot S (2011) Influence of switching connection ports of double-lumen permanent tunnelled catheters on total solute removal during dialysis. J Nephrol 24(3):338\u2013344","journal-title":"J Nephrol"},{"issue":"1","key":"2268_CR15","doi-asserted-by":"publisher","first-page":"17","DOI":"10.5301\/ijao.5000134","volume":"36","author":"CK Van","year":"2013","unstructured":"Van CK, Van BW, Vanholder R, Segers P, Verdonck P, Eloot S (2013) Evaluation of alternatives for dysfunctional double lumen central venous catheters using a two-compartmental mathematical model for different solutes. Int J Artif Organs 36(1):17\u201327","journal-title":"Int J Artif Organs"},{"key":"2268_CR16","first-page":"S7","volume":"37","author":"National Kidney Foundation","year":"2001","unstructured":"National Kidney Foundation (2001) K\/DOQI clinical practice guidelines for hemodialysis adequacy 2000. Am J Kidney Dis 37:S7\u2013S64","journal-title":"Am J Kidney Dis"},{"issue":"5","key":"2268_CR17","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1681\/ASN.V451205","volume":"4","author":"JT Daugirdas","year":"1993","unstructured":"Daugirdas JT (1993) Second generation logarithmic estimates of single-pool variable volume Kt\/V: an analysis of error. J Am Soc Nephrol 4(5):1205\u20131213","journal-title":"J Am Soc Nephrol"},{"issue":"4","key":"2268_CR18","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1016\/S0272-6386(12)80940-1","volume":"22","author":"RA Sherman","year":"1993","unstructured":"Sherman RA (1993) The measurement of dialysis access recirculation. Am J Kidney Dis 22(4):616\u2013621","journal-title":"Am J Kidney Dis"}],"container-title":["International Urology and Nephrology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11255-019-02268-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11255-019-02268-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11255-019-02268-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,26]],"date-time":"2022-09-26T23:40:53Z","timestamp":1664235653000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11255-019-02268-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,30]]},"references-count":18,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,10]]}},"alternative-id":["2268"],"URL":"https:\/\/doi.org\/10.1007\/s11255-019-02268-1","relation":{},"ISSN":["0301-1623","1573-2584"],"issn-type":[{"value":"0301-1623","type":"print"},{"value":"1573-2584","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,30]]},"assertion":[{"value":"1 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 August 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors have no conflicts of interest to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was not supported by any source and represents an original effort of our part.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Financial support"}},{"value":"This article is the result of our independent research work. Except for the contents quoted in the article, this paper does not contain the results of any other people or collectively published works.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}},{"value":"This research involves human participants; they have signed the informed consent.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}