{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T17:56:32Z","timestamp":1791914192240,"version":"4.3.4"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2022,4,21]],"date-time":"2022-04-21T00:00:00Z","timestamp":1650499200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,4,21]],"date-time":"2022-04-21T00:00:00Z","timestamp":1650499200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Key Research and Development Program from Department of Science and Technology of Sichuan Province","award":["2021YFS0022"],"award-info":[{"award-number":["2021YFS0022"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int Urol Nephrol"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Hydrophilic coated\u00a0catheters are recommended to reduce the side effects of intermittent catheterization (IC) in patients with bladder dysfunction. However, there is lack of Level one evidence to support the use of this intervention.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Search methods<\/jats:title>\n                <jats:p>Several electronic databases were systematically searched to evaluate complication incidences for hydrophilic coated (HC) and non-hydrophilic catheters (NHC).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Twelve studies were eligible for inclusion in the review. The meta-analyses exploring microscopic hematuria frequencies (RR\u2009=\u20090.69; 95% CI 0.52\u20130.90) and urethral stricture frequencies (RR\u2009=\u20090.28; 95% CI 0.13\u20130.60) showed a lower risk ratio associated with HC in comparison to NHC, whereas gross hematuria was no statistically significant difference in two groups. Subgroup analyses of gross hematuria which was grouped according to \"catheterization frequency\", \"single\/multiple catheterization\" and \"self\/other catheterization\u201d were performed and the values of combined RR were also no statistically significant difference.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Compared with non-hydrophilic catheters, the hydrophilic coated catheters have positive significance in reducing the incidence of urethral microtrauma and the urethral stricture. However, more studies are warranted for evaluating effects of hydrophilic coated catheters on the incidence of gross hematuria.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11255-022-03172-x","type":"journal-article","created":{"date-parts":[[2022,4,21]],"date-time":"2022-04-21T17:05:19Z","timestamp":1650560719000},"page":"1461-1470","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Effects of hydrophilic coated\u00a0catheters\u00a0on urethral trauma, microtrauma and adverse events with intermittent catheterization in patients with bladder dysfunction: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"54","author":[{"given":"Xi","family":"Liao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuwei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiqi","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6634-5632","authenticated-orcid":false,"given":"Ka","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,4,21]]},"reference":[{"key":"3172_CR1","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1038\/sc.2016.192","volume":"55","author":"S Shamout","year":"2017","unstructured":"Shamout S, Biardeau X, Corcos J et al (2017) Outcome comparison of different approaches to self-intermittent catheterization in neurogenic patients: a systematic review. Spinal Cord 55:629\u2013643","journal-title":"Spinal Cord"},{"issue":"6","key":"3172_CR2","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1007\/s11255-016-1236-9","volume":"48","author":"E Lamin","year":"2016","unstructured":"Lamin E, Newman DK (2016) Clean intermittent catheterization revisited. Int Urol Nephrol 48(6):931\u2013939","journal-title":"Int Urol Nephrol"},{"key":"3172_CR3","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s12894-016-0191-1","volume":"17","author":"C Rognoni","year":"2017","unstructured":"Rognoni C, Tarricone R (2017) Intermittent catheterization with hydrophilic and non-hydrophilic urinary catheters: systematic literature review and meta-analyses. BMC Urol 17:4","journal-title":"BMC Urol"},{"key":"3172_CR4","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.juro.2010.03.008","volume":"184","author":"AP Cameron","year":"2010","unstructured":"Cameron AP, Wallner LP, Tate DG et al (2010) Bladder management after spinal cord injury in the United States 1972 to 2005. J Urol 184:213\u2013217","journal-title":"J Urol"},{"issue":"1","key":"3172_CR5","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1038\/sj.sc.3100509","volume":"36","author":"A Giannantoni","year":"1998","unstructured":"Giannantoni A, Scivoletto G, Di Stasi SM et al (1998) Clean intermittent catheterization and prevention of renal disease in spinal cord injury patients. Spinal Cord 36(1):29\u201332","journal-title":"Spinal Cord"},{"issue":"3","key":"3172_CR6","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/S0022-5347(17)61055-3","volume":"107","author":"J Lapides","year":"1972","unstructured":"Lapides J, Diokno AC, Silber SJ et al (1972) Clean, intermittent self-catheterization in the treatment of urinary tract disease. J Urol 107(3):458\u2013461","journal-title":"J Urol"},{"key":"3172_CR7","first-page":"21","volume":"5","author":"A Spinu","year":"2012","unstructured":"Spinu A, Onose G, Daia C et al (2012) Intermittent catheterization in the management of post spinal cord injury (SCI) neurogenic bladder using new hydrophilic, with lubrication in close circuit devices-our own preliminary results. J Med Life 5:21\u201328","journal-title":"J Med Life"},{"key":"3172_CR8","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1097\/01.ju.0000138847.14680.7d","volume":"172","author":"B Lindehall","year":"2004","unstructured":"Lindehall B, Abrahamsson K, Hj\u00e4lm\u00e5s K et al (2004) Complications of clean intermittent catheterization in boys and young males with neurogenic bladder dysfunction. J Urol 172:1686\u20131688","journal-title":"J Urol"},{"key":"3172_CR9","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1016\/S0022-5347(17)40132-7","volume":"143","author":"JJ Wyndaele","year":"1990","unstructured":"Wyndaele JJ, Maes D (1990) Clean intermittent self-catheterization: A 12-year follow-up. J Urol 143:906\u2013908","journal-title":"J Urol"},{"key":"3172_CR10","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1002\/nau.20929","volume":"30","author":"CK Emmanuel","year":"2011","unstructured":"Emmanuel CK, Pierre D (2011) Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention. Neurourol Urodyn 30:21\u201331","journal-title":"Neurourol Urodyn"},{"key":"3172_CR11","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1007\/s11255-016-1236-9","volume":"48","author":"L Eliza","year":"2016","unstructured":"Eliza L, Diane KN (2016) Clean intermittent catheterization revisited. Int Urol Nephrol 48:931\u2013939","journal-title":"Int Urol Nephrol"},{"key":"3172_CR12","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.apmr.2012.11.010","volume":"94","author":"L Li","year":"2013","unstructured":"Li L, Wenqin Y, Hong R et al (2013) Impact of hydrophilic catheters on urinary tract infections in people with spinal cord injury: systematic review and meta-analysis of randomized controlled trials. Arch Phys Med Rehabil 94:782\u2013787","journal-title":"Arch Phys Med Rehabil"},{"key":"3172_CR13","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/j.asjsur.2019.12.009","volume":"43","author":"F Dechao","year":"2020","unstructured":"Dechao F, Liang C, Yunjin B et al (2020) Outcomes comparison of hydrophilic and non-hydrophilic catheters for patients with intermittent catheterization: an updated meta-analysis. Asian J Surg 43:633\u2013635","journal-title":"Asian J Surg"},{"issue":"373","key":"3172_CR14","first-page":"e1","volume":"13","author":"DF William","year":"2017","unstructured":"William DF, Pramod R, Melissa R et al (2017) Results of a prospective randomized control trial comparing hydrophilic to uncoated catheters in children with neurogenic bladder. J Pediatr Urol 13(373):e1-373.e5","journal-title":"J Pediatr Urol"},{"key":"3172_CR15","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/j.eururo.2005.07.018","volume":"48","author":"DJMKD Ridder","year":"2005","unstructured":"Ridder DJMKD, Everaert K, Fern\u00e1ndez LG et al (2005) Intermittent catheterisation with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients-a prospective randomised parallel comparative trial. Eur Urol 48:991\u2013995","journal-title":"Eur Urol"},{"key":"3172_CR16","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1046\/j.1464-410x.1999.00013.x","volume":"83","author":"J Pachler","year":"1999","unstructured":"Pachler J, Frimodt MC (1999) A comparison of prelubricated hydrophilic and non-hydrophilic polyvinyl chloride catheters for urethral catheterization. BJU Int 83:767\u2013769","journal-title":"BJU Int"},{"key":"3172_CR17","first-page":"408","volume":"3","author":"DC Diana","year":"2011","unstructured":"Diana DC, Katherine NM, Amy DM et al (2011) Intermittent catheterization with a hydrophilic-coated catheter delays urinary tract infections in acute spinal cord injury: a prospective, randomized. Multicenter Trial PM R 3:408\u2013411","journal-title":"Multicenter Trial PM R"},{"key":"3172_CR18","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.jpurol.2019.10.001","volume":"15","author":"T Burki","year":"2019","unstructured":"Burki T, Abasher A, Alshahrani A et al (2019) Complications and patient satisfaction with urethral clean intermittent catheterization in spina bifida patients: comparing coated vs uncoated catheters. J Pediatr Urol 15:646\u2013650","journal-title":"J Pediatr Urol"},{"key":"3172_CR19","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1016\/S0022-5347(01)65430-2","volume":"156","author":"RS Sutherland","year":"1996","unstructured":"Sutherland RS, Kogan BA, Baskin LS et al (1996) Clean intermittent catheterization in boys using the LoFric catheter. J Urol 156:2041\u20132043","journal-title":"J Urol"},{"key":"3172_CR20","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1038\/sj.sc.3100958","volume":"38","author":"J Wyndaele","year":"2000","unstructured":"Wyndaele J, Ridder DD, Everaert K et al (2000) Evaluation of the use of Urocath-Gel catheters for intermittent self-catheterization by male patients using conventional catheters for a long time. Spinal Cord 38:97\u201399","journal-title":"Spinal Cord"},{"key":"3172_CR21","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1159\/000078798","volume":"73","author":"C Luca","year":"2004","unstructured":"Luca C, Emiliano AP, Riccardo A et al (2004) Standard versus hydrophilic catheterization in the adjuvant treatment of patients with superficial bladder cancer. Urol Int 73:19\u201322","journal-title":"Urol Int"},{"key":"3172_CR22","first-page":"7","volume":"4","author":"S Sallami","year":"2011","unstructured":"Sallami S, Mouine Y, Rhouma SB et al (2011) Clean intermittent catheterization following urethral stricture surgery using a low friction catheter versus conventional plastic catheter: a prospective: a randomized trial. Urol Today Int J 4:7","journal-title":"Urol Today Int J"},{"key":"3172_CR23","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1097\/01.ju.0000051160.72187.e9","volume":"169","author":"MV Jonathan","year":"2003","unstructured":"Jonathan MV, Frederick MM, Jiensup K (2003) A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization. J Urol 169:994\u2013998","journal-title":"J Urol"},{"key":"3172_CR24","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.eururo.2005.07.009","volume":"48","author":"J Stensballe","year":"2005","unstructured":"Stensballe J, Looms D, Nielsen PN et al (2005) Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro-trauma: a prospective, randomised, participant BliMicro-trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters. Eur Urol 48:978\u2013983","journal-title":"Eur Urol"},{"key":"3172_CR25","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1111\/j.1464-410X.1994.tb07558.x","volume":"73","author":"B Kjaergaard","year":"1994","unstructured":"Kjaergaard B, Walter S, Bartholin J et al (1994) Prevention of urethral stricture recurrence using clean intermittent self-catheterization. Br J Urol 73:692\u2013695","journal-title":"Br J Urol"},{"issue":"1","key":"3172_CR26","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1080\/00365590151030822","volume":"35","author":"H Hedlund","year":"2001","unstructured":"Hedlund H, Hjelm\u00e5s K, Jonsson O et al (2001) Hydrophilic versus non-coated catheters for intermittent catheterization. Scand J Urol Nephrol 35(1):49\u201353","journal-title":"Scand J Urol Nephrol"},{"issue":"1","key":"3172_CR27","doi-asserted-by":"publisher","first-page":"12","DOI":"10.7257\/1053-816X.2012.31.1.12","volume":"31","author":"DK Newman","year":"2011","unstructured":"Newman DK, Willson MM (2011) Review of intermittent catheterization and current best practices. Urol Nurs 31(1):12\u201328 (48, 29)","journal-title":"Urol Nurs"},{"issue":"2","key":"3172_CR28","first-page":"7194","volume":"21","author":"AP Klausner","year":"2014","unstructured":"Klausner AP (2014) The Lapides legacy: 42 years and cathing. Can J Urol 21(2):7194","journal-title":"Can J Urol"},{"issue":"Suppl 1A","key":"3172_CR29","doi-asserted-by":"publisher","first-page":"67S","DOI":"10.1016\/S0002-9343(02)01061-6","volume":"113","author":"MB Siroky","year":"2002","unstructured":"Siroky MB (2002) Pathogenesis of bacteriuria and infection in the spinal cord injured patient. Am J Med 113(Suppl 1A):67S-79S","journal-title":"Am J Med"},{"issue":"1","key":"3172_CR30","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.mcna.2010.08.027","volume":"95","author":"AP Klausner","year":"2011","unstructured":"Klausner AP, Steers WD (2011) The neurogenic bladder: an update with management strategies for primary care physicians. Med Clin N Am 95(1):111\u2013120","journal-title":"Med Clin N Am"},{"key":"3172_CR31","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.actbio.2015.08.024","volume":"26","author":"S Subbu","year":"2015","unstructured":"Subbu S et al (2015) Acta Biomater 26:159\u2013168","journal-title":"Acta Biomater"},{"key":"3172_CR32","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1055\/s-0030-1255801","volume":"42","author":"A Schlager","year":"2010","unstructured":"Schlager A, Metzger YC, Adler SN (2010) Use of surface acoustic waves to reduce pain and discomfort related to indwelling nasogastric tube. Endoscopy 42:1045\u20131048","journal-title":"Endoscopy"},{"key":"3172_CR33","doi-asserted-by":"publisher","first-page":"20150","DOI":"10.1021\/acsami.6b16425","volume":"9","author":"O Sterner","year":"2017","unstructured":"Sterner O, Karageorgaki C, Z\u00fcrcher M et al (2017) Reducing friction in the eye: a comparative study of lubrication by surface-anchored synthetic and natural ocular mucin analogues. ACS Appl Mater Interfaces 9:20150\u201320160","journal-title":"ACS Appl Mater Interfaces"},{"key":"3172_CR34","doi-asserted-by":"publisher","first-page":"4601","DOI":"10.1016\/S0142-9612(02)00206-5","volume":"23","author":"MM Tunney","year":"2002","unstructured":"Tunney MM, Gorman SP (2002) Evaluation of a poly (vinyl-pyrollidone)-coated biomaterial for urological use. Biomaterials 23:4601\u20134608","journal-title":"Biomaterials"},{"key":"3172_CR35","doi-asserted-by":"publisher","first-page":"2301","DOI":"10.1007\/s10856-007-3339-4","volume":"19","author":"K Kazmierska","year":"2008","unstructured":"Kazmierska K, Szwast M, Ciach T (2008) Determination of urethral catheter surface lubricity. J Mater Sci Mater Med 19:2301\u20132306","journal-title":"J Mater Sci Mater Med"},{"key":"3172_CR36","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1038\/ncpuro0320","volume":"2","author":"AM Naude","year":"2005","unstructured":"Naude AM, Heyns CF (2005) What is the place of internal urethrotomy in the treatment of urethral stricture disease? Nat Clin Pract Urol 2:538\u2013545","journal-title":"Nat Clin Pract Urol"}],"container-title":["International Urology and Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11255-022-03172-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11255-022-03172-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11255-022-03172-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,9]],"date-time":"2022-06-09T13:29:13Z","timestamp":1654781353000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11255-022-03172-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,21]]},"references-count":36,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["3172"],"URL":"https:\/\/doi.org\/10.1007\/s11255-022-03172-x","relation":{},"ISSN":["1573-2584"],"issn-type":[{"value":"1573-2584","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,21]]},"assertion":[{"value":"8 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Xi Liao declares that she has no conflict of interest. Yuwei Liu declares that she has no conflict of interest. Shiqi Liang declares that she has no conflict of interest. Ka Li declares that she has no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}