{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T05:36:59Z","timestamp":1792820219007,"version":"4.5.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universidad de Zaragoza","id":[{"id":"https:\/\/ror.org\/012a91z28","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Vet Res Commun"],"published-print":{"date-parts":[[2026,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Cardiac arrhythmias are frequently detected during routine auscultation in athletic horses. Assessment of their clinical significance requires electrocardiography (ECG) to analyze waveforms and intervals. In recent years, portable ECG devices have been introduced to simplify electrocardiographic examination, offering advantages such as ease of use and the ability to review results via a smartphone. This study evaluated the utility and accuracy of a portable ECG device compared with a standard electrocardiograph. Simultaneous ECG recordings were obtained from 28 healthy adult horses at rest using a portable device (eKuore) and a standard electrocardiograph (Cardioline Vet600). Agreement between the two methods was assessed using Passing\u2013Bablok regression and Bland\u2013Altman analysis. All recordings were independently interpreted by two observers. A significant bias was observed between methods for heart rate, PR interval, and QRS duration, with higher values obtained using the portable device. Two arrhythmias were identified: second-degree atrioventricular block and atrial fibrillation. Agreement for arrhythmia detection was perfect (\u03ba\u2009=\u20091.00), while agreement for heart rhythm classification (bradycardia, normal rhythm, or tachycardia) was good (\u03ba\u2009=\u20090.73). In conclusion, the portable device demonstrated good diagnostic performance for arrhythmia detection during routine clinical examinations. However, further studies are required to establish reference intervals specific to this device.<\/jats:p>","DOI":"10.1007\/s11259-026-11486-9","type":"journal-article","created":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T04:22:56Z","timestamp":1788236576000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Electrocardiographic recording in horses at rest: a concordance analysis of two methods"],"prefix":"10.1007","volume":"50","author":[{"given":"Isabel","family":"Latorre","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom\u00e1s","family":"Conde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diana","family":"Marteles-Arag\u00fc\u00e9s","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio","family":"Villanueva-Saz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mar\u00eda Teresa","family":"Verde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Fern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,1]]},"reference":[{"key":"11486_CR1","doi-asserted-by":"publisher","first-page":"106043","DOI":"10.1016\/j.tvjl.2023.106043","volume":"303","author":"L Alibrandi","year":"2024","unstructured":"Alibrandi L, Tognetti R, Domenech O, Croce M, Giuntoli M, Grosso G, Vezzosi T (2024) Smartphone-based six-lead ECG: A new device for electrocardiographic recording in dogs. Vet J 303:106043. https:\/\/doi.org\/10.1016\/j.tvjl.2023.106043","journal-title":"Vet J"},{"key":"11486_CR2","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1007\/s11259-023-10206-x","volume":"48","author":"F Bindi","year":"2024","unstructured":"Bindi F, Vezzosi T, Sala G, Freccero F, Marmorini P, Bonelli F, Sgorbini M (2024) Evaluation of a smartphone electrocardiograph in healthy foals and comparison to standard base-apex electrocardiography. Vet Res Commun 48:1227\u20131232. https:\/\/doi.org\/10.1007\/s11259-023-10206-x","journal-title":"Vet Res Commun"},{"key":"11486_CR3","doi-asserted-by":"publisher","unstructured":"Brlo\u017enik M, Petri\u010d AD, Kos VK, Rashkovska A, Avbelj V (2019) Body sensor for electrocardiographic monitoring in equine medicine. 42nd International convention on information and communication technology, electronics and microelectronics (MIPRO). Opatia (Croatia). https:\/\/doi.org\/10.23919\/MIPRO.2019.8756965","DOI":"10.23919\/MIPRO.2019.8756965"},{"key":"11486_CR4","doi-asserted-by":"publisher","unstructured":"Buhl R, Meldgaard C, Barbesgaard L (2010) Cardiac arrhythmias in clinically healthy showjumping horses. Equine Vet J Suppl 196\u2013201. https:\/\/doi.org\/10.1111\/j.2042-3306.2010.00185.x","DOI":"10.1111\/j.2042-3306.2010.00185.x"},{"key":"11486_CR5","doi-asserted-by":"publisher","first-page":"2101","DOI":"10.1111\/jvim.15795","volume":"34","author":"I Corradini","year":"2020","unstructured":"Corradini I, Fern\u00e1ndez-Ruiz A, Barba M, Engel-Manchado J (2020) Stall-side screening potential of a smartphone electrocardiogram recorded over both sides of the thorax in horses. J Vet Intern Med 34:2101\u20132108. https:\/\/doi.org\/10.1111\/jvim.15795","journal-title":"J Vet Intern Med"},{"key":"11486_CR6","doi-asserted-by":"publisher","first-page":"105521","DOI":"10.1016\/j.tvjl.2020.105521","volume":"263","author":"A Decloedt","year":"2020","unstructured":"Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G (2020) Atrial fibrillation in horses part 1: Pathophysiology. Vet J 263:105521. https:\/\/doi.org\/10.1016\/j.tvjl.2020.105521","journal-title":"Vet J"},{"key":"11486_CR7","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jvc.2025.08.002","volume":"62","author":"T Gunasekaran","year":"2025","unstructured":"Gunasekaran T, Prabhakar S, Sanders RA (2025) Assessment of heart rate measurements obtained from smartphone electrocardiography as compared to 24-h Holter monitoring in dogs with atrial fibrillation. J Vet Cardiol 62:60\u201367. https:\/\/doi.org\/10.1016\/j.jvc.2025.08.002","journal-title":"J Vet Cardiol"},{"key":"11486_CR8","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1111\/jce.12634","volume":"26","author":"ZC Haberman","year":"2015","unstructured":"Haberman ZC, Jahn RT, Bose R, Tun H, Shinbane JS, Doshi RN, Chang PM, Saxon LA (2015) Wireless smartphone ECG enables large-scale screening in diverse populations. J Cardiovasc Electrophysiol 26:520\u2013526. https:\/\/doi.org\/10.1111\/jce.12634","journal-title":"J Cardiovasc Electrophysiol"},{"key":"11486_CR9","doi-asserted-by":"publisher","first-page":"698","DOI":"10.3390\/ani12060698","volume":"12","author":"ST Kjeldsen","year":"2022","unstructured":"Kjeldsen ST, Nissen SD, Buhl R, Hopster-Iversen C (2022) Paroxysmal atrial fibrillation in horses: Pathophysiology, diagnostics and clinical aspects. Animals 12:698. https:\/\/doi.org\/10.3390\/ani12060698","journal-title":"Animals"},{"key":"11486_CR10","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.rvsc.2019.05.018","volume":"125","author":"MS Kraus","year":"2019","unstructured":"Kraus MS, Rishniw M, Divers TJ, Reef VB, Gelzer AR (2019) Utility and accuracy of a smartphone-based electrocardiogram device as compared to a standard base-apex electrocardiogram in the horse. Res Vet Sci 125:141\u2013147. https:\/\/doi.org\/10.1016\/j.rvsc.2019.05.018","journal-title":"Res Vet Sci"},{"key":"11486_CR11","unstructured":"McBride GB (2005) A proposal for strength-of-agreement criteria for Lin\u2019s concordance correlation coefficient. NIWA Client Report HAM2005-062."},{"key":"11486_CR12","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1111\/jvim.16063","volume":"35","author":"LC Nath","year":"2021","unstructured":"Nath LC, Elliott AD, Weir J, Curl P, Rosanowski SM, Franklin S (2021) Incidence, recurrence, and outcome of postrace atrial fibrillation in Thoroughbred horses. J Vet Intern Med 35:1111\u20131120. https:\/\/doi.org\/10.1111\/jvim.16063","journal-title":"J Vet Intern Med"},{"key":"11486_CR13","unstructured":"Reed SM, Bayly WM, Sellon DC (2018) Equine internal medicine, 4th edn. Elsevier"},{"key":"11486_CR14","doi-asserted-by":"publisher","first-page":"149","DOI":"10.21836\/PEM20240207","volume":"40","author":"D Spitale","year":"2024","unstructured":"Spitale D, Cicogna M, Porciello F, Colonnelli M, Caivano D (2024) Use of a novel Smartphone based single-lead electrocardiogram device in clinical practice to evaluate heart rhythm in horses- a case series. Pferdeheikunde-Equine Med 40:149\u2013153. https:\/\/doi.org\/10.21836\/PEM20240207","journal-title":"Pferdeheikunde-Equine Med"},{"key":"11486_CR15","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1111\/evj.13565","volume":"55","author":"F Ter Woort","year":"2022","unstructured":"Ter Woort F, Dubois G, Tansley G, Didier M, Verdegaal L, Franklin S, Van Erck-Westergren E (2022) Validation of an equine fitness tracker: ECG quality and arrhythmia detection. Equine Vet J 55:336\u2013343. https:\/\/doi.org\/10.1111\/evj.13565","journal-title":"Equine Vet J"},{"key":"11486_CR16","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1093\/jvimsj\/aalag044","volume":"40","author":"E van Erck-Westergren","year":"2026","unstructured":"van Erck-Westergren E, O\u2019Connor S, Stewart BD, Dubois G, Morton J, Hinchcliff KW, Ter Woort F (2026) Cardiac arrhythmias during intense exercise in thoroughbred racehorses: Frequency and association with subsequent race performance. J Vet Inter Med 40:2. https:\/\/doi.org\/10.1093\/jvimsj\/aalag044","journal-title":"J Vet Inter Med"},{"key":"11486_CR17","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.cveq.2018.12.004","volume":"35","author":"G van Loon","year":"2019","unstructured":"van Loon G (2019) Cardiac Arrhythmias in Horses. Vet Clin North Am Equine Pract 35:85\u2013102. https:\/\/doi.org\/10.1016\/j.cveq.2018.12.004","journal-title":"Vet Clin North Am Equine Pract"},{"key":"11486_CR18","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.tvjl.2016.06.013","volume":"216","author":"T Vezzosi","year":"2016","unstructured":"Vezzosi T, Buralli C, Marchesotti F, Porporato F, Tognetti R, Zini E, Domenech O (2016) Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography. Vet J 216:33\u201337. https:\/\/doi.org\/10.1016\/j.tvjl.2016.06.013","journal-title":"Vet J"},{"key":"11486_CR19","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.jevs.2018.03.006","volume":"67","author":"T Vezzosi","year":"2018","unstructured":"Vezzosi T, Sgorbini M, Bonelli F, Buralli C, Pillotti M, Meucci V, Tognetti R (2018) Evaluation of a smartphone electrocardiography en healthy horses: Comparison with standard base-apex elctrocardiography. J Equine Vet Sci 67:61\u201365. https:\/\/doi.org\/10.1016\/j.jevs.2018.03.006","journal-title":"J Equine Vet Sci"},{"key":"11486_CR20","doi-asserted-by":"publisher","first-page":"e0255247","DOI":"10.1371\/journal.pone.0255247","volume":"16","author":"V Vitale","year":"2021","unstructured":"Vitale V, Vezzosi T, Tognetti R, Fraschetti C, Sgorbini M (2021) Evaluation of a new portable 1-lead digital cardiac monitor (eKuore) compared with standard base-apex electrocardiography in healthy horses. PLoS ONE 16:e0255247. https:\/\/doi.org\/10.1371\/journal.pone.0255247","journal-title":"PLoS ONE"},{"key":"11486_CR21","doi-asserted-by":"publisher","first-page":"e70","DOI":"10.1136\/vr.105759","volume":"187","author":"B Welch-Huston","year":"2020","unstructured":"Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M (2020) Comparison between smartphone electrocardiography and standard three-lead base apex electrocardiography in healthy horses. Vet Rec 187:e70. https:\/\/doi.org\/10.1136\/vr.105759","journal-title":"Vet Rec"}],"container-title":["Veterinary Research Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11259-026-11486-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11259-026-11486-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11259-026-11486-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T04:42:59Z","timestamp":1792816979000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11259-026-11486-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,12]]}},"alternative-id":["11486"],"URL":"https:\/\/doi.org\/10.1007\/s11259-026-11486-9","relation":{},"ISSN":["0165-7380","1573-7446"],"issn-type":[{"value":"0165-7380","type":"print"},{"value":"1573-7446","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"assertion":[{"value":"9 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This protocol was approved by the Animal Experimentation Ethics Advisory Committee of the University of Zaragoza (Ref. PD36\/20NE).","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent was obtained from all owners of subjects involved in the study.","order":2,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent to publish","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"545"}}