{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T06:40:12Z","timestamp":1791873612205,"version":"4.3.4"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T00:00:00Z","timestamp":1692403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T00:00:00Z","timestamp":1692403200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Oral Radiol"],"published-print":{"date-parts":[[2024,1]]},"DOI":"10.1007\/s11282-023-00705-7","type":"journal-article","created":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T12:01:25Z","timestamp":1692446485000},"page":"37-48","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Monte Carlo simulations of organ and effective doses and dose\u2013length product for dental cone-beam CT"],"prefix":"10.1007","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9255-7150","authenticated-orcid":false,"given":"Shingo","family":"Terashima","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junta","family":"Sano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minoru","family":"Osanai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Toshima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kentaro","family":"Ohuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoichiro","family":"Hosokawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,19]]},"reference":[{"key":"705_CR1","doi-asserted-by":"publisher","first-page":"20170030","DOI":"10.1259\/dmfr.20170030","volume":"46","author":"C Nardi","year":"2017","unstructured":"Nardi C, Talamonti C, Pallotta S, et al. Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT. Dentomaxillofac Radiol. 2017;46:20170030. https:\/\/doi.org\/10.1259\/dmfr.20170030.","journal-title":"Dentomaxillofac Radiol"},{"key":"705_CR2","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1051\/radiopro\/2018036","volume":"53","author":"M Sans Merce","year":"2018","unstructured":"Sans Merce M, Damet J, Becker M. Comparative organ dose levels for dentomaxillofacial examinations performed with computed tomography, cone beam CT and panoramic radiographs. Radioprotection. 2018;53:287\u201391. https:\/\/doi.org\/10.1051\/radiopro\/2018036.","journal-title":"Radioprotection"},{"key":"705_CR3","first-page":"1","volume":"23","author":"C McCollough","year":"2008","unstructured":"McCollough C, Cody D, Edyvean S, et al. The measurement, reporting, and management of radiation dose in CT. Report of AAPM Task Group. 2008;23:1\u201328.","journal-title":"Report of AAPM Task Group"},{"key":"705_CR4","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1259\/dmfr\/20920453","volume":"41","author":"R Pauwels","year":"2012","unstructured":"Pauwels R, Theodorakou C, Walker A, et al. Dose distribution for dental cone beam CT and its implication for defining a dose index. Dentomaxillofac Radiol. 2012;41:583\u201393. https:\/\/doi.org\/10.1259\/dmfr\/20920453.","journal-title":"Dentomaxillofac Radiol"},{"key":"705_CR5","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.radphyschem.2018.06.038","volume":"155","author":"MR Soares","year":"2019","unstructured":"Soares MR, Santos WS, Neves LP, et al. Dose estimate for cone beam CT equipment protocols using Monte Carlo simulation in computational adult anthropomorphic phantoms. Radiat Phys Chem. 2019;155:252\u20139.","journal-title":"Radiat Phys Chem"},{"key":"705_CR6","doi-asserted-by":"publisher","first-page":"20170047","DOI":"10.1259\/dmfr.20170047","volume":"46","author":"M Ernst","year":"2017","unstructured":"Ernst M, Manser P, Dula K, Volken W, Stampanoni MF, Fix MK. TLD measurements and Monte Carlo calculations of head and neck organ and effective doses for cone beam computed tomography using 3D Accuitomo 170. Dentomaxillofac Radiol. 2017;46:20170047. https:\/\/doi.org\/10.1259\/dmfr.20170047.","journal-title":"Dentomaxillofac Radiol"},{"key":"705_CR7","doi-asserted-by":"publisher","first-page":"92555893","DOI":"10.1259\/dmfr\/92555893","volume":"42","author":"JJ Morant","year":"2013","unstructured":"Morant JJ, Salvad\u00f3 M, Hern\u00e1ndez-Gir\u00f3n I, Casanovas R, Ortega R, Calzado A. Dosimetry of a cone beam CT device for oral and maxillofacial radiology using monte Carlo techniques and ICRP adult reference computational phantoms. Dentomaxillofac Radiol. 2013;42:92555893. https:\/\/doi.org\/10.1259\/dmfr\/92555893.","journal-title":"Dentomaxillofac Radiol"},{"key":"705_CR8","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.ejmp.2011.06.047","volume":"28","author":"JJ Morant","year":"2012","unstructured":"Morant JJ, Salvad\u00f3 M, Casanovas R, Hern\u00e1ndez-Gir\u00f3n I, Velasco E, Calzado A. Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations. Phys Med. 2012;28:200\u20139. https:\/\/doi.org\/10.1016\/j.ejmp.2011.06.047.","journal-title":"Phys Med"},{"key":"705_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2011.10.001","volume":"40","author":"ICRP","year":"2010","unstructured":"ICRP. Conversion coefficients for radiological protection quantities for external radiation exposures. Ann ICRP. 2010;40:1\u2013257.","journal-title":"Ann ICRP"},{"key":"705_CR10","doi-asserted-by":"publisher","first-page":"20140197","DOI":"10.1259\/dmfr.20140197","volume":"44","author":"JB Ludlow","year":"2015","unstructured":"Ludlow JB, Timothy R, Walker C, et al. Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol. 2015;44:20140197. https:\/\/doi.org\/10.1259\/dmfr.20140197.","journal-title":"Dentomaxillofac Radiol"},{"key":"705_CR11","unstructured":"SEDENTEXCT. D2.1 - Definition of a standard index for characterizing the CBCT dose distribution v3.1. 2010. https:\/\/www.sedentexct.eu\/system\/files\/D2.1%20v3.1%20FINAL.pdf. Accessed 9 Feb 2022."},{"key":"705_CR12","doi-asserted-by":"publisher","DOI":"10.4224\/40001303","author":"I Kawrakow","year":"2000","unstructured":"Kawrakow I, Rogers DWO, Mainegra-Hing E, Tessier F, Townson RW, Walters BRB. EGSnrc toolkit for Monte Carlo simulation of ionizing radiation transport. Tech Rep. 2000. https:\/\/doi.org\/10.4224\/40001303.","journal-title":"Tech Rep"},{"key":"705_CR13","unstructured":"NIST.gov. Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4) 2004. http:\/\/physics.nist.gov\/xaamdi. Accessed 11 Jan 2022"},{"key":"705_CR14","unstructured":"ICRP. Adult Reference Computational Phantoms. ICRP Publication 110. Ann. ICRP 39(2)\n 2009. https:\/\/www.icrp.org\/publication.asp?id=icrp%20publication%20110"},{"key":"705_CR15","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1080\/00223131.2017.1419890","volume":"55","author":"T Sato","year":"2018","unstructured":"Sato T, Iwamoto Y, Hashimoto S, et al. Features of particle and heavy ion transport code system (PHITS) version 30.2. J Nucl Sci Technol. 2018;55:684\u201390. https:\/\/doi.org\/10.1080\/00223131.2017.1419890.","journal-title":"J Nucl Sci Technol"},{"key":"705_CR16","unstructured":"ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann. ICRP. 2007"},{"key":"705_CR17","doi-asserted-by":"crossref","unstructured":"Hirayama H, Namito Y, Bielajew AF, Wilderman SJ, Nelson WR. The EGS5 Code System by SLAC-R-730 (2005) and KEK Report 2005\u20138. 2005. http:\/\/rcwww.kek.jp\/research\/egs\/egs5_manual\/slac730-160113.pdf. Accessed 8 Feb 2022","DOI":"10.2172\/877459"},{"key":"705_CR18","doi-asserted-by":"publisher","first-page":"4156","DOI":"10.1118\/1.3196182","volume":"36","author":"P Downes","year":"2009","unstructured":"Downes P, Jarvis R, Radu E, Kawrakow I, Spezi E. Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit. Med Phys. 2009;36:4156\u201367. https:\/\/doi.org\/10.1118\/1.3196182.","journal-title":"Med Phys"},{"key":"705_CR19","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20180009","author":"D Rottke","year":"2019","unstructured":"Rottke D, Dreger J, Sawada K, Honda K, Schulze D. Comparison of manual and dose reduction modes of a MORITA R100 CBCT. Dentomaxillofacial Radiolo. 2019. https:\/\/doi.org\/10.1259\/dmfr.20180009.","journal-title":"Dentomaxillofacial Radiolo"},{"key":"705_CR20","doi-asserted-by":"publisher","first-page":"072103","DOI":"10.1118\/1.4810967","volume":"40","author":"G Zhang","year":"2013","unstructured":"Zhang G, Marshall N, Bogaerts R, Jacobs R, Bosmans H. Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications. Med Phys. 2013;40:072103. https:\/\/doi.org\/10.1118\/1.4810967.","journal-title":"Med Phys"},{"key":"705_CR21","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.ejrad.2010.11.028","volume":"81","author":"R Pauwels","year":"2012","unstructured":"Pauwels R, Beinsberger J, Collaert B, et al. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol. 2012;81:267\u201371. https:\/\/doi.org\/10.1016\/j.ejrad.2010.11.028.","journal-title":"Eur J Radiol"},{"key":"705_CR22","doi-asserted-by":"publisher","first-page":"4221","DOI":"10.1016\/j.ejrad.2012.05.027","volume":"81","author":"R Pauwels","year":"2012","unstructured":"Pauwels R, Theodorakou C, Walker A, et al. Response to Letter to the Editor: Comment on \u201cEffective dose range for dental cone beam computed tomography scanners.\u201d Eur J Radiol. 2012;81:4221\u20134. https:\/\/doi.org\/10.1016\/j.ejrad.2012.05.027.","journal-title":"Eur J Radiol"},{"issue":"1\u20132","key":"705_CR23","first-page":"1","volume":"41","author":"ICRP","year":"2012","unstructured":"ICRP. ICRP statement on tissue reactions\/early and late effects of radiation in normal tissues and organs \u2013 threshold doses for tissue reactions in a radiation protection context. Ann ICRP. 2012;41(1\u20132):1\u2013322.","journal-title":"Ann ICRP"},{"key":"705_CR24","doi-asserted-by":"publisher","first-page":"1412","DOI":"10.1088\/1361-6498\/aae4e8","volume":"38","author":"I Kralik","year":"2018","unstructured":"Kralik I, Faj D, Lauc T, \u0160karica M, Popi\u0107 J, Brkic H. Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations. J Radiol Prot. 2018;38:1412\u201327. https:\/\/doi.org\/10.1088\/1361-6498\/aae4e8.","journal-title":"J Radiol Prot"},{"key":"705_CR25","unstructured":"Khan FM, Gibbons JP. Chapter 11 Treatment Planning I: Isodose Distributions. In: Khan\u2019s the physics of radiation therapy. 5th ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2014. pp.170\u2013194."}],"updated-by":[{"DOI":"10.1007\/s11282-024-00757-3","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T00:00:00Z","timestamp":1717977600000}}],"container-title":["Oral Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11282-023-00705-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11282-023-00705-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11282-023-00705-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,11]],"date-time":"2024-06-11T06:03:39Z","timestamp":1718085819000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11282-023-00705-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,19]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["705"],"URL":"https:\/\/doi.org\/10.1007\/s11282-023-00705-7","relation":{"correction":[{"id-type":"doi","id":"10.1007\/s11282-024-00757-3","asserted-by":"object"}]},"ISSN":["0911-6028","1613-9674"],"issn-type":[{"value":"0911-6028","type":"print"},{"value":"1613-9674","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,19]]},"assertion":[{"value":"14 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2024","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s11282-024-00757-3","URL":"https:\/\/doi.org\/10.1007\/s11282-024-00757-3","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain any studies with human or animal subjects performed by the any of the authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}