{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T03:05:26Z","timestamp":1787972726670,"version":"build-2784847793"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,6,21]],"date-time":"2019-06-21T00:00:00Z","timestamp":1561075200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,21]],"date-time":"2019-06-21T00:00:00Z","timestamp":1561075200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["P41 EB015909"],"award-info":[{"award-number":["P41 EB015909"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Science and Engineering Research Board, Department of Science and Technology, India","award":["MTR_2017_001021"],"award-info":[{"award-number":["MTR_2017_001021"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Mol Imaging Biol"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s11307-019-01382-x","type":"journal-article","created":{"date-parts":[[2019,6,21]],"date-time":"2019-06-21T14:03:03Z","timestamp":1561125783000},"page":"384-396","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Evaluating the Role of Amide Proton Transfer (APT)\u2013Weighted Contrast, Optimized for Normalization and Region of Interest Selection, in Differentiation of Neoplastic and Infective Mass Lesions on 3T MRI"],"prefix":"10.1007","volume":"22","author":[{"given":"Ayan","family":"Debnath","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rakesh Kumar","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6744-8326","authenticated-orcid":false,"given":"Anup","family":"Singh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,21]]},"reference":[{"key":"1382_CR1","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1007\/s11307-012-0563-1","volume":"15","author":"X Zhao","year":"2013","unstructured":"Zhao X, Wen Z, Zhang G, Huang F, Lu S, Wang X, Hu S, Chen M, Zhou J (2013) Three-dimensional turbo-spin-echo amide proton transfer MR imaging at 3-tesla and its application to high-grade human brain tumors. Mol Imaging Biol 15:114\u2013122","journal-title":"Mol Imaging Biol"},{"key":"1382_CR2","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1146\/annurev.bioeng.9.060906.151929","volume":"10","author":"AD Sherry","year":"2009","unstructured":"Sherry AD, Woods M (2009) Chemical exchange saturation transfer contrast agents for magnetic resonance imaging. Annu Rev Biomed Eng 10:391\u2013411","journal-title":"Annu Rev Biomed Eng"},{"key":"1382_CR3","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jmr.2012.11.024","volume":"229","author":"E Vinogradov","year":"2013","unstructured":"Vinogradov E, Sherry AD, Lenkinski RE (2013) CEST: from basic principles to applications, challenges and opportunities. J Magn Reson 229:155\u2013172","journal-title":"J Magn Reson"},{"key":"1382_CR4","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1002\/nbm.2899","volume":"26","author":"G Liu","year":"2013","unstructured":"Liu G, Song X, Chan KWY, Mcmahon MT (2013) Nuts and bolts of chemical exchange saturation transfer MRI. NMR Biomed 26:810\u2013828","journal-title":"NMR Biomed"},{"key":"1382_CR5","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1006\/jmre.1999.1956","volume":"143","author":"KM Ward","year":"2000","unstructured":"Ward KM, Aletras AH, Balaban RS (2000) A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Reson 143:79\u201387","journal-title":"J Magn Reson"},{"key":"1382_CR6","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1002\/mrm.22761","volume":"65","author":"PCM Van Zijl","year":"2012","unstructured":"Van Zijl PCM, Yadav NN (2012) Chemical exchange saturation transfer (CEST): what is in a name and what isn\u2019t? Magn Reson Med 65:927\u2013948","journal-title":"Magn Reson Med"},{"key":"1382_CR7","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.1002\/mrm.10651","volume":"50","author":"J Zhou","year":"2003","unstructured":"Zhou J, Lal B, Wilson DA, Laterra J, van Zijl PCM (2003) Amide proton transfer (APT) contrast for imaging of brain tumors. Magn Reson Med 50:1120\u20131126","journal-title":"Magn Reson Med"},{"key":"1382_CR8","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1038\/nm907","volume":"9","author":"J Zhou","year":"2003","unstructured":"Zhou J, Payen JF, Wilson DA et al (2003) Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat Med 9:1085\u20131090","journal-title":"Nat Med"},{"key":"1382_CR9","first-page":"788","volume":"45","author":"J Zhou","year":"2008","unstructured":"Zhou J, Yan K, Zhu H (2008) A simple model for understanding the origin of the amide proton transfer MRI signal in tissue. Magn Reson Med 45:788\u2013802","journal-title":"Magn Reson Med"},{"key":"1382_CR10","doi-asserted-by":"publisher","unstructured":"Zhou J, Heo H, Knutsson L, Van Zijl\u00a0 PCM, Jiang S (2019) APT-weighted MRI: techniques, current neuro applications, and challenging issues. J Magn Reson Imaging: https:\/\/doi.org\/10.1002\/jmri.26645","DOI":"10.1002\/jmri.26645"},{"key":"1382_CR11","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1016\/j.neuroimage.2010.02.050","volume":"51","author":"Z Wen","year":"2010","unstructured":"Wen Z, Hu S, Huang F, Wang X, Guo L, Quan X, Wang S, Zhou J (2010) MR imaging of high-grade brain tumors using endogenous protein and peptide-based contrast. NeuroImage 51:616\u2013622","journal-title":"NeuroImage"},{"key":"1382_CR12","doi-asserted-by":"publisher","first-page":"1743","DOI":"10.1038\/jcbfm.2011.23","volume":"31","author":"PZ Sun","year":"2011","unstructured":"Sun PZ, Cheung J, Wang E, Lo E (2011) Association between pH-weighted endogenous amide proton chemical exchange saturation transfer MRI and tissue lactic acidosis during acute ischemic stroke. J Cereb Blood Flow Metab 31:1743\u20131750","journal-title":"J Cereb Blood Flow Metab"},{"key":"1382_CR13","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1002\/mrm.21591","volume":"59","author":"PZ Sun","year":"2008","unstructured":"Sun PZ, Murata Y, Lu J, Wang X, Lo EH, Sorensen AG (2008) Relaxation-compensated fast multislice amide proton transfer (APT) imaging of acute ischemic stroke. Magn Reson Med 59:1175\u20131182","journal-title":"Magn Reson Med"},{"key":"1382_CR14","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s00330-015-3805-1","volume":"26","author":"S Jiang","year":"2016","unstructured":"Jiang S, Yu H, Wang X, Lu S, Li Y, Feng L, Zhang Y, Heo HY, Lee DH, Zhou J, Wen Z (2016) Molecular MRI differentiation between primary central nervous system lymphomas and high-grade gliomas using endogenous protein-based amide proton transfer MR imaging at 3 tesla. J Eur Radiol 26:64\u201371","journal-title":"J Eur Radiol"},{"key":"1382_CR15","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1093\/neuonc\/not158","volume":"16","author":"O Togao","year":"2014","unstructured":"Togao O, Yoshiura T, Keupp J, Hiwatashi A, Yamashita K, Kikuchi K, Suzuki Y, Suzuki SO, Iwaki T, Hata N, Mizoguchi M, Yoshimoto K, Sagiyama K, Takahashi M, Honda H (2014) Amide proton transfer imaging of adult diffuse gliomas: correlation with histopathological grades. Neuro-Oncology 16:441\u2013448","journal-title":"Neuro-Oncology"},{"key":"1382_CR16","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1002\/mrm.20989","volume":"56","author":"CK Jones","year":"2006","unstructured":"Jones CK, Schlosser MJ, Van Zijl PCM et al (2006) Amide proton transfer imaging of human brain tumors at 3T. Magn Reson Med 56:585\u2013592","journal-title":"Magn Reson Med"},{"key":"1382_CR17","unstructured":"Debnath A, Sahoo P, Gupta P, Gupta RK, Singh A (2016) APT MRI of intracranial mass lesions at 3T and comparison with perfusion parameters. Proceedings of International Society for Magnetic Resonance in Medicine (ISMRM): 24th Annual Meeting & Exhibition, May 7-13, Singapore, program number 3712"},{"key":"1382_CR18","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1007\/s00330-016-4328-0","volume":"27","author":"O Togao","year":"2017","unstructured":"Togao O, Hiwatashi A, Yamashita K, Kikuchi K, Keupp J, Yoshimoto K, Kuga D, Yoneyama M, Suzuki SO, Iwaki T, Takahashi M, Iihara K, Honda H (2017) Grading diffuse gliomas without intense contrast enhancement by amide proton transfer MR imaging: comparisons with diffusion and perfusion-weighted imaging. Eur Radiol 27:578\u2013588","journal-title":"Eur Radiol"},{"key":"1382_CR19","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1007\/s11060-014-1715-8","volume":"122","author":"A Sakata","year":"2015","unstructured":"Sakata A, Okada T, Yamamoto A, Kanagaki M, Fushimi Y, Okada T, Dodo T, Arakawa Y, Schmitt B, Miyamoto S, Togashi K (2015) Grading glial tumors with amide proton transfer MR imaging: different analytical approaches. J Neuro-Oncol 122:339\u2013348","journal-title":"J Neuro-Oncol"},{"key":"1382_CR20","doi-asserted-by":"crossref","first-page":"5834","DOI":"10.18632\/oncotarget.13970","volume":"8","author":"Y Bai","year":"2015","unstructured":"Bai Y, Lin Y, Zhang W et al (2015) Noninvasive amide proton transfer magnetic resonance imaging in evaluating the grading and cellularity of gliomas. Oncotarget 8:5834\u20135842","journal-title":"Oncotarget"},{"key":"1382_CR21","first-page":"1989","volume":"24","author":"M Law","year":"2003","unstructured":"Law M, Yang S, Wang H, Babb JS, Johnson G, Cha S, Knopp EA, Zagzag D (2003) Glioma grading: sensitivity, specificity, and predictive values of perfusion MR imaging and proton MR spectroscopic imaging compared with conventional MR imaging. Am J Neuroradiol 24:1989\u20131998","journal-title":"Am J Neuroradiol"},{"key":"1382_CR22","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1002\/mrm.24290","volume":"69","author":"A Singh","year":"2013","unstructured":"Singh A, Cai K, Haris M, Hariharan H, Reddy R (2013) On B 1 inhomogeneity correction of in vivo human brain glutamate chemical exchange saturation transfer contrast at 7T. Magn Reson Med 69:818\u2013824","journal-title":"Magn Reson Med"},{"key":"1382_CR23","first-page":"882","volume":"261","author":"Y Kang","year":"2011","unstructured":"Kang Y, Choi SH, Kim KG (2011) Gliomas: histogram analysis of apparent diffusion coeffi cient maps with standard- or high- b-value diffusion-weighted MR imaging\u2014correlation with tumor grade. Neuroradiology 261:882\u2013890","journal-title":"Neuroradiology"},{"key":"1382_CR24","first-page":"761","volume":"28","author":"M Law","year":"2007","unstructured":"Law M, Young R, Babb J, Pollack E, Johnson G (2007) Histogram analysis versus region of interest analysis of dynamic susceptibility contrast perfusion MR imaging data in the grading of cerebral gliomas. Am J Neuroradiol 28:761\u2013766","journal-title":"Am J Neuroradiol"},{"key":"1382_CR25","doi-asserted-by":"publisher","first-page":"2205","DOI":"10.1038\/bjc.2014.512","volume":"111","author":"N Just","year":"2014","unstructured":"Just N (2014) Improving tumour heterogeneity MRI assessment with histograms. Br J Cancer 111:2205\u20132213","journal-title":"Br J Cancer"},{"key":"1382_CR26","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1002\/jmri.24441","volume":"40","author":"YK Tee","year":"2013","unstructured":"Tee YK, Donahue MJ, Harston GWJ et al (2013) Quantification of amide proton transfer effect pre- and post-gadolinium contrast agent administration. J Magn Reson Imaging 40:832\u2013838","journal-title":"J Magn Reson Imaging"},{"key":"1382_CR27","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1002\/mrm.22546","volume":"64","author":"H Zhu","year":"2010","unstructured":"Zhu H, Jones CK, Van Zijl PCM et al (2010) Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. Magn Reson Med 64:638\u2013644","journal-title":"Magn Reson Med"},{"key":"1382_CR28","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1002\/jmri.24067","volume":"38","author":"J Zhou","year":"2013","unstructured":"Zhou J, Zhu H, Lim M, Blair L, Quinones-Hinojosa A, Messina SA, Eberhart CG, Pomper MG, Laterra J, Barker PB, van Zijl PCM, Blakeley JO (2013) Three-dimensional amide proton transfer MR imaging of gliomas: initial experience and comparison with gadolinium enhancement. J Magn Reson Imaging 38:1119\u20131128","journal-title":"J Magn Reson Imaging"},{"key":"1382_CR29","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1002\/mrm.21873","volume":"61","author":"M Kim","year":"2009","unstructured":"Kim M, Gillen J, Landman BA, Zhou J, van Zijl PCM (2009) Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn Reson Med 61:1441\u20131450","journal-title":"Magn Reson Med"},{"key":"1382_CR30","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.jmr.2011.05.001","volume":"211","author":"M Zaiss","year":"2011","unstructured":"Zaiss M, Schmitt B, Bachert P (2011) Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra. J Magn Reson 211:149\u2013155","journal-title":"J Magn Reson"},{"key":"1382_CR31","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/S0167-8655(97)00131-1","volume":"18","author":"A Mehnert","year":"1997","unstructured":"Mehnert A, Jackway P (1997) An improved seeded region growing algorithm. Pattern Recogn Lett 18:1065\u20131071","journal-title":"Pattern Recogn Lett"},{"key":"1382_CR32","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1038\/nm.2268","volume":"17","author":"J Zhou","year":"2011","unstructured":"Zhou J, Tryggestad E, Wen Z, Lal B, Zhou T, Grossman R, Wang S, Yan K, Fu DX, Ford E, Tyler B, Blakeley J, Laterra J, van Zijl PCM (2011) Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptides. Nat Med 17:130\u2013134","journal-title":"Nat Med"},{"key":"1382_CR33","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1148\/radiol.2015142979","volume":"278","author":"JE Park","year":"2016","unstructured":"Park JE, Kim HS, Park KJ, Kim SJ, Kim JH, Smith SA (2016) Pre and posttreatment glioma: comparison of amide proton transfer imaging with MR spectroscopy for biomarkers of tumor proliferation. Radiology 278:514\u2013523","journal-title":"Radiology"},{"key":"1382_CR34","unstructured":"Debnath A, Gupta RK, Singh A (2019) To evaluate the role of APT-w contrast, optimized for normalization and ROIs selection, in differentiating infective and neo-plastic mass lesions. Proceedings of International Society for Magnetic Resonance in Medicine (ISMRM): 27th Annual Meeting & Exhibition, April 11-16, Canada, program number 4347"},{"key":"1382_CR35","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1002\/mrm.26820","volume":"78","author":"S Jiang","year":"2017","unstructured":"Jiang S, Zou T, Eberhart CG, Villalobos MAV, Heo HY, Zhang Y, Wang Y, Wang X, Yu H, du Y, van Zijl PCM, Wen Z, Zhou J (2017) Predicting IDH mutation status in grade II gliomas using amide proton transfer-weighted (APTw) MRI. Mag Reson Med 78:1100\u20131109","journal-title":"Mag Reson Med"},{"key":"1382_CR36","first-page":"1","volume":"18","author":"H Yu","year":"2019","unstructured":"Yu H, Wen X, Wu P et al (2019) Can amide proton transfer\u2013weighted imaging differentiate tumor grade and predict Ki-67 proliferation status of meningioma? Eur Radiol 18:1\u20139","journal-title":"Eur Radiol"},{"key":"1382_CR37","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/nbm.3216","volume":"28","author":"K Cai","year":"2015","unstructured":"Cai K, Singh A, Popatni H et al (2015) CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor. NMR Biomed 28:1\u20138","journal-title":"NMR Biomed"},{"key":"1382_CR38","unstructured":"Debnath A, Singh A (2017) Lorentzian probabilistic sum based Z-spectrum fitting approach for computing CEST and NOE contrast and its comparison with lorentzian sum and asymmetry analysis.\u00a0Proceedings of International Society for Magnetic Resonance in Medicine (ISMRM): 25th\u00a0Annual Meeting & Exhibition, April 22-27, Hawaii, program number 1975"},{"key":"1382_CR39","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1002\/nbm.3054","volume":"27","author":"M Zaiss","year":"2014","unstructured":"Zaiss M, Xu LZ, Goerke S et al (2014) Inverse Z-spectrum analysis for spillover, MT and T1-corrected steady-state pulsed CEST-MRI-application to pH-weighted MRI of acute stroke. NMR Biomed 27:240\u2013252","journal-title":"NMR Biomed"},{"key":"1382_CR40","first-page":"1","volume":"00","author":"S Goerke","year":"2019","unstructured":"Goerke S, Soehngen Y, Deshmane A et al (2019) Relaxation-compensated APT and rNOE CEST-MRI of human brain tumors at 3T. Magn Reson Med 00:1\u201311","journal-title":"Magn Reson Med"}],"container-title":["Molecular Imaging and Biology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11307-019-01382-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11307-019-01382-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11307-019-01382-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,20]],"date-time":"2024-07-20T02:44:51Z","timestamp":1721443491000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11307-019-01382-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,21]]},"references-count":40,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["1382"],"URL":"https:\/\/doi.org\/10.1007\/s11307-019-01382-x","relation":{},"ISSN":["1536-1632","1860-2002"],"issn-type":[{"value":"1536-1632","type":"print"},{"value":"1860-2002","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,21]]},"assertion":[{"value":"21 June 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}