{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T00:39:36Z","timestamp":1790728776044,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,8,6]],"date-time":"2019-08-06T00:00:00Z","timestamp":1565049600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,8,6]],"date-time":"2019-08-06T00:00:00Z","timestamp":1565049600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sleep Breath"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s11325-019-01901-8","type":"journal-article","created":{"date-parts":[[2019,8,6]],"date-time":"2019-08-06T20:28:31Z","timestamp":1565123311000},"page":"825-833","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Extended evaluation of the efficacy of a proactive forced oscillation technique-based auto-CPAP algorithm"],"prefix":"10.1007","volume":"24","author":[{"given":"S. D.","family":"Herkenrath","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Treml","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Anduleit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Richter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Pietzke-Calcagnile","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Schwaibold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Sch\u00e4fer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Alshut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Grimm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Hagmeyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. J.","family":"Randerath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,8,6]]},"reference":[{"key":"1901_CR1","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1016\/S2213-2600(15)00416-6","volume":"3","author":"DJ Bratton","year":"2015","unstructured":"Bratton DJ, Gaisl T, Schlatzer C, Kohler M (2015) Comparison of the effects of continuous positive airway pressure and mandibular advancement devices on sleepiness in patients with obstructive sleep apnoea: a network meta-analysis. Lancet Respir Med 3:869\u2013878. https:\/\/doi.org\/10.1016\/S2213-2600(15)00416-6","journal-title":"Lancet Respir Med"},{"key":"1901_CR2","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1016\/j.amjcard.2015.08.046","volume":"116","author":"WT Qureshi","year":"2015","unstructured":"Qureshi WT, Nasir UB, Alqalyoobi S et al (2015) Meta-analysis of continuous positive airway pressure as a therapy of atrial fibrillation in obstructive sleep apnea. Am J Cardiol 116:1767\u20131773. https:\/\/doi.org\/10.1016\/j.amjcard.2015.08.046","journal-title":"Am J Cardiol"},{"key":"1901_CR3","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1513\/pats.200709-150MG","volume":"5","author":"MH Sanders","year":"2008","unstructured":"Sanders MH, Montserrat JM, Farr\u00e9 R, Givelber RJ (2008) Positive pressure therapy: a perspective on evidence-based outcomes and methods of application. Proc Am Thorac Soc 5:161\u2013172. https:\/\/doi.org\/10.1513\/pats.200709-150MG","journal-title":"Proc Am Thorac Soc"},{"key":"1901_CR4","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00408-008-9079-5","volume":"186","author":"J Jing","year":"2008","unstructured":"Jing J, Huang T, Cui W, Shen H (2008) Effect on quality of life of continuous positive airway pressure in patients with obstructive sleep apnea syndrome: a meta-analysis. Lung 186:131\u2013144. https:\/\/doi.org\/10.1007\/s00408-008-9079-5","journal-title":"Lung"},{"key":"1901_CR5","first-page":"1177","volume":"87","author":"L Mo","year":"2007","unstructured":"Mo L, He Q (2007) Effect of long-term continuous positive airway pressure ventilation on blood pressure in patients with obstructive sleep apnea hypopnea syndrome: a meta-analysis of clinical trials. Zhonghua Yi Xue Za Zhi 87:1177\u20131180","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"1901_CR6","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1093\/sleep\/29.3.381","volume":"29","author":"P Gay","year":"2006","unstructured":"Gay P, Weaver T, Loube D et al (2006) Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults. Sleep 29:381\u2013401","journal-title":"Sleep"},{"key":"1901_CR7","doi-asserted-by":"publisher","unstructured":"Giles TL, Lasserson TJ, Smith BH, et al (2006) Continuous positive airways pressure for obstructive sleep apnoea in adults. Cochrane Database Syst Rev. CD001106. https:\/\/doi.org\/10.1002\/14651858.CD001106.pub3","DOI":"10.1002\/14651858.CD001106.pub3"},{"key":"1901_CR8","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1093\/sleep\/29.3.375","volume":"29","author":"CA Kushida","year":"2006","unstructured":"Kushida CA, Littner MR, Hirshkowitz M et al (2006) Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. Sleep 29:375\u2013380","journal-title":"Sleep"},{"key":"1901_CR9","doi-asserted-by":"publisher","first-page":"1046","DOI":"10.1016\/S0140-6736(05)71141-7","volume":"365","author":"JM Marin","year":"2005","unstructured":"Marin JM, Carrizo SJ, Vicente E, Agusti AG (2005) Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet 365:1046\u20131053. https:\/\/doi.org\/10.1016\/S0140-6736(05)71141-7","journal-title":"Lancet"},{"key":"1901_CR10","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1378\/chest.128.2.624","volume":"128","author":"F Campos-Rodriguez","year":"2005","unstructured":"Campos-Rodriguez F, Pe\u00f1a-Gri\u00f1an N, Reyes-Nu\u00f1ez N et al (2005) Mortality in obstructive sleep apnea-hypopnea patients treated with positive airway pressure. Chest 128:624\u2013633. https:\/\/doi.org\/10.1378\/chest.128.2.624","journal-title":"Chest"},{"key":"1901_CR11","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1109\/10.464375","volume":"42","author":"K Behbehani","year":"1995","unstructured":"Behbehani K, Yen FC, Burk JR et al (1995) Automatic control of airway pressure for treatment of obstructive sleep apnea. IEEE Trans Biomed Eng 42:1007\u20131016. https:\/\/doi.org\/10.1109\/10.464375","journal-title":"IEEE Trans Biomed Eng"},{"key":"1901_CR12","doi-asserted-by":"publisher","first-page":"S131","DOI":"10.1093\/sleep\/19.suppl_9.S131","volume":"19","author":"M Berthon-Jones","year":"1996","unstructured":"Berthon-Jones M, Lawrence S, Sullivan CE, Grunstein R (1996) Nasal continuous positive airway pressure treatment: current realities and future. Sleep 19:S131\u2013S135","journal-title":"Sleep"},{"key":"1901_CR13","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1093\/sleep\/19.6.502","volume":"19","author":"B Fleury","year":"1996","unstructured":"Fleury B, Rakotonanahary D, Hausser-Hauw C et al (1996) A laboratory validation study of the diagnostic mode of the Autoset system for sleep-related respiratory disorders. Sleep 19:502\u2013505","journal-title":"Sleep"},{"key":"1901_CR14","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1183\/09031936.97.10030587","volume":"10","author":"M Gugger","year":"1997","unstructured":"Gugger M (1997) Comparison of ResMed AutoSet (version 3.03) with polysomnography in the diagnosis of the sleep apnoea\/hypopnoea syndrome. Eur Respir J 10:587\u2013591","journal-title":"Eur Respir J"},{"key":"1901_CR15","doi-asserted-by":"publisher","first-page":"S281","DOI":"10.1093\/sleep\/19.suppl_10.S281","volume":"19","author":"F S\u00e9ri\u00e8s","year":"1996","unstructured":"S\u00e9ri\u00e8s F (1996) Auto CPAP in the treatment of sleep apnea hypopnea syndrome. Sleep 19:S281\u2013S283","journal-title":"Sleep"},{"key":"1901_CR16","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1164\/ajrccm.154.3.8810613","volume":"154","author":"H Teschler","year":"1996","unstructured":"Teschler H, Berthon-Jones M, Thompson AB et al (1996) Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. Am J Respir Crit Care Med 154:734\u2013740. https:\/\/doi.org\/10.1164\/ajrccm.154.3.8810613","journal-title":"Am J Respir Crit Care Med"},{"key":"1901_CR17","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1183\/09031936.97.10092073","volume":"10","author":"H Teschler","year":"1997","unstructured":"Teschler H, Farhat AA, Exner V et al (1997) AutoSet nasal CPAP titration: constancy of pressure, compliance and effectiveness at 8 month follow-up. Eur Respir J 10:2073\u20132078","journal-title":"Eur Respir J"},{"key":"1901_CR18","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1093\/sleep\/19.6.497","volume":"19","author":"S Sharma","year":"1996","unstructured":"Sharma S, Wali S, Pouliot Z et al (1996) Treatment of obstructive sleep apnea with a self-titrating continuous positive airway pressure (CPAP) system. Sleep 19:497\u2013501","journal-title":"Sleep"},{"key":"1901_CR19","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1164\/ajrccm.153.2.8564134","volume":"153","author":"JC Meurice","year":"1996","unstructured":"Meurice JC, Marc I, S\u00e9ri\u00e8s F (1996) Efficacy of auto-CPAP in the treatment of obstructive sleep apnea\/hypopnea syndrome. Am J Respir Crit Care Med 153:794\u2013798. https:\/\/doi.org\/10.1164\/ajrccm.153.2.8564134","journal-title":"Am J Respir Crit Care Med"},{"key":"1901_CR20","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1183\/09031936.98.11051121","volume":"11","author":"JC Meurice","year":"1998","unstructured":"Meurice JC, Paquereau J, Denjean A et al (1998) Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea\/hypopnoea syndrome. Eur Respir J 11:1121\u20131127","journal-title":"Eur Respir J"},{"key":"1901_CR21","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1152\/jappl.1956.8.6.587","volume":"8","author":"AB Dubois","year":"1956","unstructured":"Dubois AB, Brody AW, Lewis DH, Burgess BF (1956) Oscillation mechanics of lungs and chest in man. J Appl Physiol 8:587\u2013594. https:\/\/doi.org\/10.1152\/jappl.1956.8.6.587","journal-title":"J Appl Physiol"},{"key":"1901_CR22","doi-asserted-by":"publisher","first-page":"725","DOI":"10.5664\/jcsm.4844","volume":"11","author":"K Zhu","year":"2015","unstructured":"Zhu K, Roisman G, Aouf S, Escourrou P (2015) All APAPs are not equivalent for the treatment of sleep disordered breathing: a bench evaluation of eleven commercially available devices. J Clin Sleep Med 11:725\u2013734. https:\/\/doi.org\/10.5664\/jcsm.4844","journal-title":"J Clin Sleep Med"},{"key":"1901_CR23","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.5665\/sleep.2086","volume":"35","author":"H-CC Huang","year":"2012","unstructured":"Huang H-CC, Hillman DR, McArdle N (2012) Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data. Sleep 35:1277\u20131283. https:\/\/doi.org\/10.5665\/sleep.2086","journal-title":"Sleep"},{"key":"1901_CR24","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1007\/s11325-014-1048-z","volume":"19","author":"CA Nigro","year":"2015","unstructured":"Nigro CA, Gonz\u00e1lez S, Arce A et al (2015) Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea. Sleep Breath 19:569\u2013578. https:\/\/doi.org\/10.1007\/s11325-014-1048-z","journal-title":"Sleep Breath"},{"key":"1901_CR25","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1136\/thoraxjnl-2015-207700","volume":"71","author":"JL P\u00e9pin","year":"2016","unstructured":"P\u00e9pin JL, Tamisier R, Baguet JP et al (2016) Fixed-pressure CPAP versus auto-adjusting CPAP: comparison of efficacy on blood pressure in obstructive sleep apnoea, a randomised clinical trial. Thorax 71:726\u2013733. https:\/\/doi.org\/10.1136\/thoraxjnl-2015-207700","journal-title":"Thorax"},{"key":"1901_CR26","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1016\/j.chest.2018.04.020","volume":"154","author":"O Marrone","year":"2018","unstructured":"Marrone O, Cibella F, P\u00e9pin J-L et al (2018) Fixed but not autoadjusting positive airway pressure attenuates the time-dependent decline in glomerular filtration rate in patients with OSA. Chest 154:326\u2013334. https:\/\/doi.org\/10.1016\/j.chest.2018.04.020","journal-title":"Chest"},{"key":"1901_CR27","volume-title":"The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, version 2.4","author":"RB Berry","year":"2017","unstructured":"Berry RB, Brooks R, Gamaldo CE (2017) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, version 2.4. American Academy of Sleep Medicine, Darien"},{"key":"1901_CR28","doi-asserted-by":"publisher","first-page":"363","DOI":"10.5665\/sleep.2450","volume":"36","author":"WJ Randerath","year":"2013","unstructured":"Randerath WJ, Treml M, Priegnitz C et al (2013) Evaluation of a noninvasive algorithm for differentiation of obstructive and central hypopneas. Sleep 36:363\u2013368. https:\/\/doi.org\/10.5665\/sleep.2450","journal-title":"Sleep"},{"key":"1901_CR29","doi-asserted-by":"publisher","first-page":"1550","DOI":"10.1164\/ajrccm.160.5.9902085","volume":"160","author":"JR Badia","year":"1999","unstructured":"Badia JR, Farr\u00e9 RO, John Kimoff R et al (1999) Clinical application of the forced oscillation technique for CPAP titration in the sleep apnea\/hypopnea syndrome. Am J Respir Crit Care Med 160:1550\u20131554. https:\/\/doi.org\/10.1164\/ajrccm.160.5.9902085","journal-title":"Am J Respir Crit Care Med"},{"key":"1901_CR30","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1183\/09031936.01.17304560","volume":"17","author":"R Farr\u00e9","year":"2001","unstructured":"Farr\u00e9 R, Rigau J, Montserrat JM et al (2001) Evaluation of a simplified oscillation technique for assessing airway obstruction in sleep apnoea. Eur Respir J 17:456\u2013461","journal-title":"Eur Respir J"},{"key":"1901_CR31","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1183\/09031936.00.15118500","volume":"15","author":"D Navajas","year":"2000","unstructured":"Navajas D, Duvivier C, Farre R, Peslin R (2000) A simplified method for monitoring respiratory impedance during continuous positive airway pressure. Eur Respir J 15:185\u2013191","journal-title":"Eur Respir J"},{"key":"1901_CR32","doi-asserted-by":"publisher","first-page":"1523","DOI":"10.1183\/09031936.00060311","volume":"40","author":"V Jobin","year":"2012","unstructured":"Jobin V, Rigau J, Beauregard J et al (2012) Evaluation of upper airway patency during Cheyne-Stokes breathing in heart failure patients. Eur Respir J 40:1523\u20131530. https:\/\/doi.org\/10.1183\/09031936.00060311","journal-title":"Eur Respir J"},{"key":"1901_CR33","doi-asserted-by":"publisher","first-page":"1806","DOI":"10.1152\/jappl.1995.78.5.1806","volume":"78","author":"MS Badr","year":"1995","unstructured":"Badr MS, Toiber F, Skatrud JB, Dempsey J (1995) Pharyngeal narrowing\/occlusion during central sleep apnea. J Appl Physiol 78:1806\u20131815. https:\/\/doi.org\/10.1152\/jappl.1995.78.5.1806","journal-title":"J Appl Physiol"},{"key":"1901_CR34","doi-asserted-by":"publisher","first-page":"86","DOI":"10.4103\/atm.ATM_321_17","volume":"13","author":"G Nigam","year":"2018","unstructured":"Nigam G, Riaz M, Chang ET, Camacho M (2018) Natural history of treatment-emergent central sleep apnea on positive airway pressure: a systematic review. Ann Thorac Med 13:86\u201391. https:\/\/doi.org\/10.4103\/atm.ATM_321_17","journal-title":"Ann Thorac Med"},{"key":"1901_CR35","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1152\/japplphysiol.00584.2016","volume":"122","author":"W M\u00f6ller","year":"2017","unstructured":"M\u00f6ller W, Feng S, Domanski U et al (2017) Nasal high flow reduces dead space. J Appl Physiol (1985) 122:191\u2013197. https:\/\/doi.org\/10.1152\/japplphysiol.00584.2016","journal-title":"J Appl Physiol (1985)"}],"container-title":["Sleep and Breathing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11325-019-01901-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11325-019-01901-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11325-019-01901-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T21:52:06Z","timestamp":1695073926000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11325-019-01901-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,6]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["1901"],"URL":"https:\/\/doi.org\/10.1007\/s11325-019-01901-8","relation":{},"ISSN":["1520-9512","1522-1709"],"issn-type":[{"value":"1520-9512","type":"print"},{"value":"1522-1709","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,6]]},"assertion":[{"value":"6 June 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 July 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Mr. Schwaibold reports to be employee of L\u00f6wenstein Medical Technology, the manufacturer of the evaluated device. Responsibilities: R&D and clinical trials. No ownership or shares of the company, nor any direct revenues depending on the success of the device.Mrs. Sch\u00e4fer reports to be employee of L\u00f6wenstein Medical Technology, the manufacturer of the evaluated device.Dr. Alshut reports to be employee of L\u00f6wenstein Medical Technology, the manufacturer of the evaluated device. Responsibilities: R&D and new devices. No ownership or shares of the company, nor any direct revenues depending on the success of the device.Mr. Grimm reports to be employee of L\u00f6wenstein Medical Technology, the manufacturer of the evaluated device. Responsibilities: clinical trials. No ownership or shares of the company, nor any direct revenues depending on the success of the device.Mr. Herkenrath, Dr. Treml, Mr. Anduleit, Mrs. Richter, Dr. Pietzke-Calcagnile, and Dr. Hagmeyer declare that they have no conflict of interest.Prof. Randerath reports grants from Philips Respironics, grants from Inspire, grants from Resmed, grants from L\u00f6wenstein Medical, grants from Weinmann, outside the submitted work.The research site has received financial support from L\u00f6wenstein Medical GmbH & Co. KG, Bad Ems, Germany, to cover personnel and material expenses for conducting this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee (Ethics Committee of the Medical Association of North Rhine, reference no. 2016253) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}