{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T12:26:47Z","timestamp":1788956807146,"version":"build-2803163510"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T00:00:00Z","timestamp":1718668800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T00:00:00Z","timestamp":1718668800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sleep Breath"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The goal of this review is to provide sleep physicians, dentists, and researchers with an evidence-based overview of the literature on smart mandibular advancement devices (MADs) for the treatment of obstructive sleep apnea.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A systematic literature search was conducted by two blinded reviewers and an information specialist. A smart MAD was defined as any MAD with additional functionality besides mandibular protrusion. The bibliographic databases Medline, Embase, and Scopus were used to identify relevant publications. Studies were included if they described any stage of development of smart MADs. A total of 3162 titles and abstracts were screened for their relevance. In total, 58 articles were selected for full-text screening, 26 of which were included in this review.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The overall quality of the available literature was low. Most of the studies were observational, clinical or applied-research articles. The authors classified MADs into two main groups: passive and active. Passive MADs measured patient data, most commonly patient compliance. Active MADs adjusted protrusion of the mandible in response to patient data and were found in various phases of technological readiness (in development, demonstration, or deployment).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Innovations in smart mandibular advancement devices most frequently track patient compliance. Devices measuring other health parameters and active, feedback-controlled, devices are increasingly reported on. However, studies demonstrating their added benefit over traditional methods remain sparse. With further study, smart mandibular advancement devices have the potential to improve the efficiency of obstructive sleep apnea treatment and provide new treatment possibilities.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11325-024-03068-3","type":"journal-article","created":{"date-parts":[[2024,6,18]],"date-time":"2024-06-18T02:01:23Z","timestamp":1718676083000},"page":"1879-1887","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Smart mandibular advancement devices for obstructive sleep apnea: a systematic literature review"],"prefix":"10.1007","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8768-8802","authenticated-orcid":false,"given":"Joshua","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8271-5047","authenticated-orcid":false,"given":"Boudewijn R.A.M.","family":"Rosenm\u00f6ller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8271-4821","authenticated-orcid":false,"given":"Tom C.T.","family":"van Riet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-7149-0155","authenticated-orcid":false,"given":"Misha L.","family":"Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Faridi S.","family":"Jamaludin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8396-2501","authenticated-orcid":false,"given":"Jean-Pierre T.F.","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"de Lange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,18]]},"reference":[{"issue":"9 Suppl 1","key":"3068_CR1","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3949\/ccjm.86.s1.02","volume":"86","author":"JV Rundo","year":"2019","unstructured":"Rundo JV (2019) Obstructive sleep apnea basics. Cleve Clin J Med 86(9 Suppl 1):2\u20139. https:\/\/doi.org\/10.3949\/ccjm.86.s1.02","journal-title":"Cleve Clin J Med"},{"issue":"8","key":"3068_CR2","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/S2213-2600(19)30198-5","volume":"7","author":"AV Benjafield","year":"2019","unstructured":"Benjafield AV et al (2019) Estimation of the global prevalence and burden of obstructive sleep apnoea: a literature-based analysis. Lancet Respir Med 7(8):687\u2013698. https:\/\/doi.org\/10.1016\/S2213-2600(19)30198-5","journal-title":"Lancet Respir Med"},{"key":"3068_CR3","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.smrv.2016.07.002","volume":"34","author":"CV Senaratna","year":"2017","unstructured":"Senaratna CV et al (2017) Prevalence of obstructive sleep apnea in the general population: a systematic review. Sleep Med Rev 34:70\u201381. https:\/\/doi.org\/10.1016\/j.smrv.2016.07.002","journal-title":"Sleep Med Rev"},{"issue":"5","key":"3068_CR4","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1183\/09031936.00144711","volume":"39","author":"M Marklund","year":"2012","unstructured":"Marklund M, Verbraecken J, Randerath W (2012) Non-CPAP therapies in obstructive sleep apnoea: mandibular advancement device therapy. Eur Respir J 39(5):1241\u20131247. https:\/\/doi.org\/10.1183\/09031936.00144711","journal-title":"Eur Respir J"},{"issue":"2","key":"3068_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1080\/08869634.2019.1708610","volume":"40","author":"A Chen","year":"2022","unstructured":"Chen A, Burger MS, Rietdijk-Smulders M, Smeenk F (2022) Mandibular advancement device: Effectiveness and dental side effects. A real-life study. Cranio 40(2):97\u2013106. https:\/\/doi.org\/10.1080\/08869634.2019.1708610","journal-title":"A real-life study. Cranio"},{"key":"3068_CR6","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1007\/978-3-031-06413-5_22","volume":"1384","author":"AM Mohammadieh","year":"2022","unstructured":"Mohammadieh AM, Sutherland K, Chan ASL, Cistulli PA (2022) Mandibular advancement splint therapy. Adv Exp Med Biol 1384:373\u2013385. https:\/\/doi.org\/10.1007\/978-3-031-06413-5_22","journal-title":"Adv Exp Med Biol"},{"issue":"1","key":"3068_CR7","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1177\/0954411920959879","volume":"235","author":"Z Ma","year":"2021","unstructured":"Ma Z, Hyde P, Drinnan M, Munguia J (2021) Development of a smart-fit system for CPAP interface selection. Proc Inst Mech Eng H 235(1):44\u201353. https:\/\/doi.org\/10.1177\/0954411920959879","journal-title":"Proc Inst Mech Eng H"},{"issue":"4","key":"3068_CR8","doi-asserted-by":"publisher","first-page":"575","DOI":"10.5664\/jcsm.7048","volume":"14","author":"J Beyers","year":"2018","unstructured":"Beyers J et al (2018) Evaluation of a Trial Period with a sleep position trainer in patients with positional sleep apnea. J Clin Sleep Med 14(4):575\u2013583. https:\/\/doi.org\/10.5664\/jcsm.7048","journal-title":"J Clin Sleep Med"},{"issue":"3","key":"3068_CR9","doi-asserted-by":"publisher","first-page":"220164","DOI":"10.1183\/20734735.0164-2022","volume":"18","author":"J Verbraecken","year":"2022","unstructured":"Verbraecken J et al (2022) Non-CPAP therapy for obstructive sleep apnoea. Breathe (Sheff) 18(3)220164. https:\/\/doi.org\/10.1183\/20734735.0164-2022","journal-title":"Breathe (Sheff)"},{"issue":"3","key":"3068_CR10","doi-asserted-by":"publisher","first-page":"911","DOI":"10.5664\/jcsm.9758","volume":"18","author":"EV Mosca","year":"2022","unstructured":"Mosca EV et al (2022) In-home mandibular repositioning during sleep using MATRx plus predicts outcome and efficacious positioning for oral appliance treatment of obstructive sleep apnea. J Clin Sleep Med 18(3):911\u2013919. https:\/\/doi.org\/10.5664\/jcsm.9758","journal-title":"J Clin Sleep Med"},{"key":"3068_CR11","doi-asserted-by":"publisher","unstructured":"Kwon JS et al (2022) Effectiveness of remote monitoring and feedback on objective compliance with a mandibular advancement device for treatment of obstructive sleep apnea. J Sleep Res 31(3):e13508. https:\/\/doi.org\/10.1111\/jsr.13508","DOI":"10.1111\/jsr.13508"},{"key":"3068_CR12","doi-asserted-by":"publisher","unstructured":"Yeh KY et al (2017) A Wireless Monitoring System using a tunneling sensor array in a smart oral Appliance for Sleep Apnea Treatment. Sens (Basel) 17(10). https:\/\/doi.org\/10.3390\/s17102358","DOI":"10.3390\/s17102358"},{"key":"3068_CR13","unstructured":"Welcome to the Preferred Reporting Items for Systematic Reviews (2023) and Meta-Analyses (PRISMA) website! PRSIMA. http:\/\/www.prisma-statement.org\/.\u00a0Accessed 30 May 2023"},{"key":"3068_CR14","unstructured":"Scoping Reviews Resources (2023) Joanna Briggs Institute. https:\/\/jbi.global\/scoping-review-network\/resources.\u00a0Accessed 30 May 2023"},{"key":"3068_CR15","doi-asserted-by":"publisher","unstructured":"Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A (2016) Rayyan-a web and mobile app for systematic reviews. Syst Rev 5(1):210. https:\/\/doi.org\/10.1186\/s13643-016-0384-4","DOI":"10.1186\/s13643-016-0384-4"},{"issue":"15","key":"3068_CR16","doi-asserted-by":"publisher","first-page":"262","DOI":"10.3238\/arztebl.2009.0262","volume":"106","author":"B Rohrig","year":"2009","unstructured":"Rohrig B, du Prel JB, Wachtlin D, Blettner M (2009) Types of study in medical research: part 3 of a series on evaluation of scientific publications. Dtsch Arztebl Int 106(15):262\u2013268. https:\/\/doi.org\/10.3238\/arztebl.2009.0262","journal-title":"Dtsch Arztebl Int"},{"key":"3068_CR17","unstructured":"Mankins JC (2004) Technology readiness levels. Office of space access and technology, NASA"},{"key":"3068_CR18","volume-title":"Endorobotics: Design, R&D and Future Trends","author":"L Manfredi","year":"2022","unstructured":"Manfredi L (2022) Endorobotics: Design, R&D and Future trends, 1st edn. Academic","edition":"1"},{"key":"3068_CR19","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1109\/EMBC.2017.8037130","volume":"2017","author":"Y Castillo","year":"2017","unstructured":"Castillo Y, Blanco-Almazan D, Whitney J, Mersky B, Jane R (2017) Characterization of a tooth microphone coupled to an oral appliance device: A new system for monitoring OSA patients. Annu Int Conf IEEE Eng Med Biol Soc 2017:1543\u20131546. https:\/\/doi.org\/10.1109\/EMBC.2017.8037130","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"2","key":"3068_CR20","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1007\/BF02344801","volume":"39","author":"SC Tjin","year":"2001","unstructured":"Tjin SC, Tan YK, Yow M, Lam YZ, Hao J (2001) Recording compliance of dental splint use in obstructive sleep apnoea patients by force and temperature modelling. Med Biol Eng Comput 39(2):182\u2013184. https:\/\/doi.org\/10.1007\/BF02344801","journal-title":"Med Biol Eng Comput"},{"key":"3068_CR21","doi-asserted-by":"publisher","unstructured":"Gjerde K et al (2022) Partner perceptions are associated with objective sensor-measured adherence to oral appliance therapy in obstructive sleep apnea. J Sleep Res 31(2):e13462. https:\/\/doi.org\/10.1111\/jsr.13462","DOI":"10.1111\/jsr.13462"},{"issue":"2","key":"3068_CR22","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1111\/joor.12584","volume":"45","author":"K Gjerde","year":"2018","unstructured":"Gjerde K, Lehmann S, Naterstad IF, Berge ME, Johansson A (2018) Reliability of an adherence monitoring sensor embedded in an oral appliance used for treatment of obstructive sleep apnoea. J Oral Rehabil 45(2):110\u2013115. https:\/\/doi.org\/10.1111\/joor.12584","journal-title":"J Oral Rehabil"},{"key":"3068_CR23","doi-asserted-by":"publisher","unstructured":"Stern J, Lee K, Kuhns D, Martinez-Kratz JF (2021) Efficacy and Effectiveness of the ProSomnus(R) [IA] Sleep Device for the Treatment of Obstructive Sleep Apnea: EFFECTS Study. Cureus 13(6)e15391. https:\/\/doi.org\/10.7759\/cureus.15391","DOI":"10.7759\/cureus.15391"},{"issue":"9","key":"3068_CR24","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.5664\/jcsm.9288","volume":"17","author":"K Sutherland","year":"2021","unstructured":"Sutherland K et al (2021) Treatment usage patterns of oral appliances for obstructive sleep apnea over the first 60 days: a cluster analysis. J Clin Sleep Med 17(9):1785\u20131792. https:\/\/doi.org\/10.5664\/jcsm.9288","journal-title":"J Clin Sleep Med"},{"issue":"10","key":"3068_CR25","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1007\/s00380-019-01392-3","volume":"34","author":"U Yamamoto","year":"2019","unstructured":"Yamamoto U, Nishizaka M, Tsuda H, Tsutsui H, Ando SI (2019) Crossover comparison between CPAP and mandibular advancement device with adherence monitor about the effects on endothelial function, blood pressure and symptoms in patients with obstructive sleep apnea. Heart Vessels 34(10):1692\u20131702. https:\/\/doi.org\/10.1007\/s00380-019-01392-3","journal-title":"Heart Vessels"},{"issue":"11","key":"3068_CR26","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.5664\/jcsm.8034","volume":"15","author":"GE de Vries","year":"2019","unstructured":"de Vries GE et al (2019) Long-Term Objective Adherence to Mandibular Advancement Device Therapy Versus Continuous Positive Airway Pressure in Patients With Moderate Obstructive Sleep Apnea. J Clin Sleep Med 15(11):1655\u20131663. https:\/\/doi.org\/10.5664\/jcsm.8034","journal-title":"J Clin Sleep Med"},{"issue":"5","key":"3068_CR27","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1378\/chest.13-0613","volume":"144","author":"M Dieltjens","year":"2013","unstructured":"Dieltjens M et al (2013) Objectively measured vs self-reported compliance during oral appliance therapy for sleep-disordered breathing. Chest 144(5):1495\u20131502. https:\/\/doi.org\/10.1378\/chest.13-0613","journal-title":"Chest"},{"issue":"10","key":"3068_CR28","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1001\/jamaoto.2015.1756","volume":"141","author":"M Dieltjens","year":"2015","unstructured":"Dieltjens M et al (2015) Determinants of objective compliance during oral Appliance Therapy in patients with sleep-disordered breathing: a prospective clinical trial. JAMA Otolaryngol Head Neck Surg 141(10):894\u2013900. https:\/\/doi.org\/10.1001\/jamaoto.2015.1756","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"issue":"1","key":"3068_CR29","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1136\/thoraxjnl-2012-201900","volume":"68","author":"OM Vanderveken","year":"2013","unstructured":"Vanderveken OM, Dieltjens M, Wouters K, De Backer WA, Van de Heyning PH, Braem MJ (2013) Objective measurement of compliance during oral appliance therapy for sleep-disordered breathing. Thorax 68(1):91\u20136. https:\/\/doi.org\/10.1136\/thoraxjnl-2012-201900","journal-title":"Thorax"},{"key":"3068_CR30","doi-asserted-by":"publisher","unstructured":"Xu L et al (2021) Objective adherence to dental device versus positive airway pressure treatment in adults with obstructive sleep apnea. J Sleep Res 30(4):e13240. https:\/\/doi.org\/10.1111\/jsr.13240","DOI":"10.1111\/jsr.13240"},{"issue":"3","key":"3068_CR31","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1111\/j.1479-8425.2009.00402.x","volume":"7","author":"Y Inoko","year":"2009","unstructured":"Inoko Y, Yoshimura K, Kato C, Morita O, Kohno M (2009) Efficacy and safety of temperature data loggers in measuring compliance with the use of oral appliances. Sleep Biol Rhythms 7(3):188\u2013192. https:\/\/doi.org\/10.1111\/j.1479-8425.2009.00402.x","journal-title":"Sleep Biol Rhythms"},{"issue":"2","key":"3068_CR32","doi-asserted-by":"publisher","first-page":"53","DOI":"10.5875\/ausmt.v7i2.1327","volume":"7","author":"KY Yeh","year":"2017","unstructured":"Yeh KY et al (2017) A Wirelessly Rechargeable Integrated System for Automatic Sleep Monitoring in a smart oral Appliance. Int J Autom Smart Technol 7(2):53\u201359. https:\/\/doi.org\/10.5875\/ausmt.v7i2.1327","journal-title":"Int J Autom Smart Technol"},{"key":"3068_CR33","doi-asserted-by":"publisher","unstructured":"Chen YT et al (2018) Tongue pressure sensing array integrated with a system-on-chip embedded in a mandibular advancement splint.\u00a0Micromachines (Basel) 9(7). https:\/\/doi.org\/10.3390\/mi9070352","DOI":"10.3390\/mi9070352"},{"issue":"2","key":"3068_CR34","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1109\/TBCAS.2021.3065824","volume":"15","author":"S Nabavi","year":"2021","unstructured":"Nabavi S, Bhadra S (2021) Smart Mandibular Advancement device for Intraoral Monitoring of Cardiorespiratory Parameters and sleeping postures. IEEE Trans Biomed Circuits Syst 15(2):248\u2013258. https:\/\/doi.org\/10.1109\/TBCAS.2021.3065824","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"3068_CR35","doi-asserted-by":"publisher","unstructured":"Lee S-J et al (2021) s-Guard: multisensor embedded obstructive sleep apnea and bruxism real-time data transmission intraoral appliance device. Appl Sci 11(9).\u00a0https:\/\/doi.org\/10.3390\/app11094182","DOI":"10.3390\/app11094182"},{"key":"3068_CR36","doi-asserted-by":"publisher","unstructured":"Cohen-Levy J, Petelle B, Pinguet J, Limerat E, Fleury B (2013) Forces created by mandibular advancement devices in OSAS patients: a pilot study during sleep. Sleep Breath 17(2):781\u2013789. https:\/\/doi.org\/10.1007\/s11325-012-0765-4","DOI":"10.1007\/s11325-012-0765-4"},{"key":"3068_CR37","doi-asserted-by":"publisher","unstructured":"Jacquet W, De Meyer MMD, Remmers JE, Jahromi SAZ, Hambrook DA, Marks LAM (2022) The acoustical and perceptual features of snore-related sounds in patients with obstructive sleep apnea sleeping with the dynamic mandibular advancement system MATRx plus(R). Sleep Breath 26(1):215\u2013224. https:\/\/doi.org\/10.1007\/s11325-021-02392-2","DOI":"10.1007\/s11325-021-02392-2"},{"key":"3068_CR38","doi-asserted-by":"publisher","first-page":"4296","DOI":"10.1109\/EMBC.2016.7591677","volume":"2016","author":"R Brugarolas","year":"2016","unstructured":"Brugarolas R, Valero-Sarmiento JM, Bozkurt A, Essick GK (2016) Auto-adjusting mandibular repositioning device for in-home use. Annu Int Conf IEEE Eng Med Biol Soc 2016:4296\u20134299. https:\/\/doi.org\/10.1109\/EMBC.2016.7591677","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"7","key":"3068_CR39","doi-asserted-by":"publisher","first-page":"871","DOI":"10.5664\/jcsm.6656","volume":"13","author":"JE Remmers","year":"2017","unstructured":"Remmers JE et al (2017) A feedback-controlled mandibular positioner identifies individuals with sleep apnea who will respond to oral appliance therapy. J Clin Sleep Med 13(7):871\u2013880. https:\/\/doi.org\/10.5664\/jcsm.6656","journal-title":"J Clin Sleep Med"},{"issue":"8","key":"3068_CR40","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1111\/joor.12802","volume":"46","author":"S Mullane","year":"2019","unstructured":"Mullane S, Loke W (2019) Influence of short-term side effects on oral sleep appliance compliance among CPAP-intolerant patients: an objective monitoring of compliance. J Oral Rehabil 46(8):715\u2013722. https:\/\/doi.org\/10.1111\/joor.12802","journal-title":"J Oral Rehabil"},{"issue":"1","key":"3068_CR41","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1111\/jopr.12076","volume":"23","author":"YK Smith","year":"2014","unstructured":"Smith YK, Verrett RG (2014) Evaluation of a novel device for measuring patient compliance with oral appliances in the treatment of obstructive sleep apnea. J Prosthodont 23(1):31\u20138. https:\/\/doi.org\/10.1111\/jopr.12076","journal-title":"J Prosthodont"}],"container-title":["Sleep and Breathing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11325-024-03068-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11325-024-03068-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11325-024-03068-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T12:12:41Z","timestamp":1727957561000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11325-024-03068-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,18]]},"references-count":41,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,10]]}},"alternative-id":["3068"],"URL":"https:\/\/doi.org\/10.1007\/s11325-024-03068-3","relation":{},"ISSN":["1520-9512","1522-1709"],"issn-type":[{"value":"1520-9512","type":"print"},{"value":"1522-1709","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,18]]},"assertion":[{"value":"18 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}