{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T01:15:29Z","timestamp":1784769329708,"version":"3.55.0"},"reference-count":69,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2018,12,18]],"date-time":"2018-12-18T00:00:00Z","timestamp":1545091200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100010661","name":"Horizon 2020 Framework Programme","doi-asserted-by":"publisher","award":["H2020-MSCA-ITN-2017 SEP-210411486"],"award-info":[{"award-number":["H2020-MSCA-ITN-2017 SEP-210411486"]}],"id":[{"id":"10.13039\/100010661","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100011201","name":"FP7 Science in Society","doi-asserted-by":"publisher","award":["FP7-ENV-2013- 603946"],"award-info":[{"award-number":["FP7-ENV-2013- 603946"]}],"id":[{"id":"10.13039\/100011201","id-type":"DOI","asserted-by":"publisher"}]},{"name":"eppa","award":["2016\/003"],"award-info":[{"award-number":["2016\/003"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Environ Sci Pollut Res"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s11356-018-3975-x","type":"journal-article","created":{"date-parts":[[2018,12,17]],"date-time":"2018-12-17T22:01:44Z","timestamp":1545084104000},"page":"4654-4666","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Influence of electronic cigarette vaping on the composition of indoor organic pollutants, particles, and exhaled breath of bystanders"],"prefix":"10.1007","volume":"26","author":[{"given":"Barend L.","family":"van Drooge","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esther","family":"Marco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noemi","family":"Perez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7391-5768","authenticated-orcid":false,"given":"Joan O.","family":"Grimalt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,12,18]]},"reference":[{"key":"3975_CR1","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1515\/reveh-2016-0059","volume":"32","author":"ZN Abidin","year":"2017","unstructured":"Abidin ZN, Abidin ZE, Zulkifli A, Karuppiah K, Norkhadijah S, Ismail S, Siddiq A (2017) Electronic cigarettes and indoor air quality: a review of studies using human volunteers. Rev Environ Health 32:235\u2013244","journal-title":"Rev Environ Health"},{"key":"3975_CR2","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1126\/science.1233798","volume":"339","author":"MO Andreae","year":"2013","unstructured":"Andreae MO (2013) The aerosol nucleation puzzle. Science 339:911\u2013912","journal-title":"Science"},{"key":"3975_CR3","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/S1352-2310(96)00215-4","volume":"31","author":"SO Baek","year":"1997","unstructured":"Baek SO, Kim YS, Perry R (1997) Indoor air quality in homes, offices and restaurants in Korean urban areas\u2014indoor\/outdoor relationships. Atmos Environ 31:529\u2013544","journal-title":"Atmos Environ"},{"key":"3975_CR4","doi-asserted-by":"crossref","unstructured":"Ballb\u00e8 M, Mart\u00ednez-S\u00e1nchez JM, Sureda X, Fu M, P\u00e9rez-Ortu\u00f1o R, Pascual JA, Salt\u00f3 E, Fern\u00e1ndez E (2017) Cigarettes vs. e-cigarettes: passive exposure at home measured by means of airborne marker and biomarkers. Environ Res 135:76\u201380","DOI":"10.1016\/j.envres.2014.09.005"},{"key":"3975_CR5","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.envres.2007.01.008","volume":"104","author":"S Batterman","year":"2007","unstructured":"Batterman S, Jia CR, Hatzivasilis G (2007) Migration of volatile organic compounds from attached garages to residences: a major exposure source. Environ Res 104:224\u2013240","journal-title":"Environ Res"},{"key":"3975_CR6","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s00103-008-0425-9","volume":"51","author":"Bekanntmachung des Umweltbundesamtes","year":"2008","unstructured":"Bekanntmachung des Umweltbundesamtes (2008) Vergleichswerte f\u00fcr fl\u00fcchtige organische Verbindungen (VOC und Aldehyde) in der Innenraumluft von Haushalten in Deutschland Ergebnisse des repr\u00e4sentativen Kinder-Umwelt-Surveys (KUS) des Umweltbundesamtes. Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 51:109\u2013112","journal-title":"Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz"},{"key":"3975_CR7","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1038\/sj.jes.7500590","volume":"18","author":"G Bolte","year":"2008","unstructured":"Bolte G, Heitmann D, Kiranoglu M, Schierl R, Diemer J, Koerner W, Fromme H (2008) Exposure to environmental tobacco smoke in German restaurants, pubs and discotheques. J Expo Sci Environ Epidemiol 18:262\u2013271","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"3975_CR8","doi-asserted-by":"publisher","unstructured":"Chen R, Aherrera A, Isichei C, Olmedo P, Jarmul S, Cohen JE, Navas-Acien A, Rule AM (2018) Assessment of indoor air quality at an electronic cigarette (vaping) convention. J Expo Sci Environ Epidemiol 28:522\u2013529. https:\/\/doi.org\/10.1038\/s41370-017-0005-x","DOI":"10.1038\/s41370-017-0005-x"},{"key":"3975_CR9","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1016\/0957-1272(91)90008-3","volume":"25","author":"JC Chuang","year":"1991","unstructured":"Chuang JC, Mack GA, Kuhlman MR, Wilson NK (1991) Polycyclic aromatic-hydrocarbons and their derivatives in indoor and outdoor air in an 8-home study. Atmos Environ 25:369\u2013380","journal-title":"Atmos Environ"},{"key":"3975_CR10","doi-asserted-by":"publisher","first-page":"282","DOI":"10.3390\/ijerph120100282","volume":"12","author":"S Colard","year":"2015","unstructured":"Colard S, O\u2019Connell G, Verron T, Cahours X, Pritchard JD (2015) Electronic cigarettes and indoor air quality: a simple approach to modeling potential bystander exposures to nicotine. Int J Environ Res Public Health 12:282\u2013299","journal-title":"Int J Environ Res Public Health"},{"key":"3975_CR11","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1093\/ntr\/ntt203","volume":"16","author":"J Czogala","year":"2014","unstructured":"Czogala J, Goniewicz ML, Fidelus B, Zielinska-Danch W, Travers MJ, Sobczak A (2014) Secondhand exposure to vapors from electronic cigarettes. Nicotine Tob Res 16:655\u2013662","journal-title":"Nicotine Tob Res"},{"key":"3975_CR12","doi-asserted-by":"publisher","first-page":"1569","DOI":"10.1016\/j.atmosenv.2007.10.088","volume":"42","author":"RE Dodson","year":"2008","unstructured":"Dodson RE, Levy JI, Sprengler JD, Shine JP, Bennett DH (2008) Influence of basement, garages and common hallways on indoor residential volatile organic compound concentrations. Atmos Environ 42:1569\u20131581","journal-title":"Atmos Environ"},{"key":"3975_CR13","doi-asserted-by":"publisher","first-page":"2299","DOI":"10.1016\/j.atmosenv.2004.12.026","volume":"39","author":"RD Edwards","year":"2005","unstructured":"Edwards RD, Schweizer C, Jantunen M, Lai HK, Bayer-Oglesby L, Katsouyanni K, Nieuwenhuijsen M, Saarela K, Sram R, K\u00fcnzli N (2005) Personal exposures to VOC in the upper end of the distribution\u2014relationships to indoor, outdoor and workplace concentrations. Atmos Environ 39:2299\u20132307","journal-title":"Atmos Environ"},{"key":"3975_CR14","unstructured":"EU. Directive 2008\/50\/EU of the European Parliament and of the Council of May 2008"},{"key":"3975_CR15","unstructured":"EU. Directive 2014\/40\/EU of the European Parliament and of the Council of 3rd of April 2014"},{"key":"3975_CR16","unstructured":"European Commission (2005) Critical appraisal of the setting and implementation of indoor exposure limits in the EU. Brussels, European Commission, Joint Research Centre. http:\/\/ec.europa.eu\/health\/ph_projects\/2002\/pollution\/fp_pollution_2002_frep_02.pdf . Accessed 14 Dec 2018"},{"key":"3975_CR17","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1007\/s40572-015-0072-x","volume":"2","author":"E Fernandez","year":"2015","unstructured":"Fernandez E, Ballbe M, Sureda X, Fu M, Salto E, Martinez-Sanchez JM (2015) Particulate matter from electronic cigarettes and conventional cigarettes: a systematic review and observational study. Curr Environ Health Rep 2:423\u2013429","journal-title":"Curr Environ Health Rep"},{"key":"3975_CR18","doi-asserted-by":"publisher","first-page":"3713","DOI":"10.1016\/S1352-2310(00)00067-4","volume":"34","author":"PH Fischer","year":"2000","unstructured":"Fischer PH, Hoek G, van Reeuwijk H, Briggs DJ, Lebret E, van Wijnen JH, Kingham S, Elliot PE (2000) Traffic-related differences in outdoor and indoor concentrations of particles and volatile organic compounds in Amsterdam. Atmos Environ 34:3713\u20133722","journal-title":"Atmos Environ"},{"key":"3975_CR19","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.chroma.2015.05.042","volume":"1404","author":"M Fontal","year":"2015","unstructured":"Fontal M, van Drooge BL, Lopez JF, Fernandez P, Grimalt JO (2015) Broad spectrum analysis of polar and apolar organic compounds in submicron atmospheric particles. J Chromatrogr A 1404:28\u201338","journal-title":"J Chromatrogr A"},{"key":"3975_CR20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.scitotenv.2004.02.002","volume":"326","author":"H Fromme","year":"2004","unstructured":"Fromme H, Lahrz T, Piloty M, Gebhardt H, Oddoy A, R\u00fcden H (2004) Polycyclic aromatic hydrocarbons inside and outside of apartments in an urban area. Sci Total Environ 326:143\u2013149","journal-title":"Sci Total Environ"},{"key":"3975_CR21","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1055\/s-2008-1046775","volume":"70","author":"H Fromme","year":"2008","unstructured":"Fromme H, Heitmann D, Dietrich S (2008) Air quality in schools\u2014classroom levels of carbon dioxide (CO2), volatile organic compounds (VOC), aldehydes, endotoxins and cat allergen. Gesundheitswesen 70:88\u201397","journal-title":"Gesundheitswesen"},{"key":"3975_CR22","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/S0013-9351(03)00035-5","volume":"94","author":"H Guo","year":"2004","unstructured":"Guo H, Lee SC, Chan LY, Li WM (2004) Risk assessment of exposure to volatile organic compounds in different indoor environments. Environ Res 94:57\u201366","journal-title":"Environ Res"},{"key":"3975_CR23","doi-asserted-by":"publisher","first-page":"5074","DOI":"10.1021\/es800304y","volume":"42","author":"P Gustafson","year":"2008","unstructured":"Gustafson P, \u00d6stman C, S\u00e4llsten G (2008) Indoor levels of polycyclic aromatic hydrocarbons in homes with or without wood burning for heating. Environ Sci Technol 42:5074\u20135080","journal-title":"Environ Sci Technol"},{"key":"3975_CR24","unstructured":"Harrison RM, Delgado-Saborit JM, Baker SJ, Aquilina N, Meddings C, Harrad S, Matthews I, Vardoulakis S, Anderson HR (2009) Measurement and modeling of exposure to selected air toxics for health effects studies and verification by biomarkers. Boston, MA, Health Effects Institute (HEI Research Report 143). https:\/\/europepmc.org\/abstract\/med\/19999825 . Accessed 14 Dec 2018"},{"key":"3975_CR25","first-page":"495","volume":"8","author":"M Jantunen","year":"1998","unstructured":"Jantunen M, H\u00e4nninen O, Katsouyanni K, Kn\u00f6ppel H, K\u00fcnzli N, Lebret E, Maroni M, Saarela K, Sram RJ, Zmirou D (1998) Air pollution exposure in European cities: the EXPOLIS study. J Expo Anal Environ Epidemiol 8:495\u2013518","journal-title":"J Expo Anal Environ Epidemiol"},{"key":"3975_CR26","doi-asserted-by":"publisher","first-page":"2083","DOI":"10.1016\/j.atmosenv.2007.11.055","volume":"42","author":"CR Jia","year":"2008","unstructured":"Jia CR, Batterman S, Godwin C (2008) VOCs in industrial, urban and suburban neighbourhoods\u2014part 1: indoor and outdoor concentrations, variation and risk drivers. Atmos Environ 42:2083\u20132100","journal-title":"Atmos Environ"},{"key":"3975_CR27","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1080\/10473289.2001.10464251","volume":"51","author":"J Jurvelin","year":"2001","unstructured":"Jurvelin J, Vartiainen M, Jantunen M, Pasanen P (2001) Personal exposure levels and microenvironmental concentrations of formaldehyde and acetaldehyde in Helsinki metropolitan area, Finland. J Air Waste Manag Assoc 51:17\u201324","journal-title":"J Air Waste Manag Assoc"},{"key":"3975_CR28","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1016\/j.chemosphere.2018.05.039","volume":"206","author":"V Kauneliene","year":"2018","unstructured":"Kauneliene V, Meisutovic-Akhtarieva M, Martuzevicius D (2018) A review of the impacts of tobacco heating system on indoor air quality versus conventional pollution sources. Chemosphere 206:568\u2013578","journal-title":"Chemosphere"},{"key":"3975_CR29","doi-asserted-by":"publisher","DOI":"10.1038\/srep16383","volume":"5","author":"YH Kim","year":"2015","unstructured":"Kim YH, Kim KH (2015) A novel method to quantify the emission and conversion of VOCs in the smoking of electronic cigarettes. Sci Rep 5:16383","journal-title":"Sci Rep"},{"key":"3975_CR30","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1021\/es000192y","volume":"35","author":"YM Kim","year":"2001","unstructured":"Kim YM, Harrad S, Harrison RM (2001) Concentrations and sources of VOCs in urban domestic and public microenvironments. Environ Sci Technol 35:997\u20131004","journal-title":"Environ Sci Technol"},{"key":"3975_CR31","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/S1352-2310(99)00321-0","volume":"34","author":"S Kingham","year":"2000","unstructured":"Kingham S, Briggs D, Elliot P, Fischer P, Lebret E (2000) Spatial variations in the concentrations of traffic-related pollutants in indoor and outdoor air in Huddersfield, England. Atmos Environ 34:905\u2013916","journal-title":"Atmos Environ"},{"key":"3975_CR32","first-page":"259","volume":"6","author":"S Kirchner","year":"2007","unstructured":"Kirchner S, Arenes JF, Cochet C, Derbez M, Duboudin C, Elias P, Gregoire A, J\u00e9dor B, Lucas JP, Pasquier N, Pigneret M, Ramalho O (2007) Etat de la qualit\u00e9 de l\u2019air dans les logements fran\u00e7ais. Environ Risq Sant\u00e9 6:259\u2013269","journal-title":"Environ Risq Sant\u00e9"},{"key":"3975_CR33","first-page":"670","volume":"18","author":"D Kotzias","year":"2009","unstructured":"Kotzias D, Geiss O, Tirendi S, Barrero-Moreno J, Reina V, Gotti A, Cimino G, Marafante E, Sarigiannis D, Casati B (2009) Exposure to multiple air contaminants in public buildings, schools and kindergartens: the European indoor air monitoring and exposure assessment (AIRMEX) study. Fres Environ Bull 18:670\u2013681","journal-title":"Fres Environ Bull"},{"key":"3975_CR34","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1136\/tc.2009.029728","volume":"18","author":"TA Kraev","year":"2009","unstructured":"Kraev TA, Adamkiewicz G, Hammond SK, Sprengler JD (2009) Indoor concentrations of nicotine in low-income, multi-unit housing: associations with smoking behaviours and housing characteristics. Tob Control 18:438\u2013444","journal-title":"Tob Control"},{"issue":"2\u20134","key":"3975_CR35","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.atmosres.2008.01.005","volume":"90","author":"M Kulmala","year":"2008","unstructured":"Kulmala M, Kerminen VM (2008) On the formation and growth of atmospheric nanoparticles. Atmos Res 90(2\u20134):132\u2013150","journal-title":"Atmos Res"},{"key":"3975_CR36","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1136\/oem.55.4.249","volume":"55","author":"PL Leung","year":"1998","unstructured":"Leung PL, Harrison PM (1998) Evaluation of personal exposure to monoaromatic hydrocarbons. Occup Environ Med 55:249\u2013257","journal-title":"Occup Environ Med"},{"key":"3975_CR37","doi-asserted-by":"publisher","first-page":"9271","DOI":"10.1021\/acs.est.7b00710","volume":"51","author":"J Logue","year":"2017","unstructured":"Logue J, Sleiman M, Montesinos VN, Russell ML, Litter MI, Benowitz NL, Gundel LA, Destaillats H (2017) Emissions from electronic cigarettes: assessing vapers\u00b4 intake of toxic compounds, secondhand exposure, and associated health impacts. Environ Sci Technol 51:9271\u20139279","journal-title":"Environ Sci Technol"},{"key":"3975_CR38","doi-asserted-by":"publisher","first-page":"11177","DOI":"10.3390\/ijerph111111177","volume":"11","author":"GA Long","year":"2014","unstructured":"Long GA (2014) Comparison of select analytes in exhaled aerosol from e-cigarettes with exhaled smoke from a conventional cigarette and exhaled breaths. Int J Environ Res Public Health 11:11177\u201311191","journal-title":"Int J Environ Res Public Health"},{"key":"3975_CR39","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.atmosenv.2015.07.028","volume":"118","author":"J Madureira","year":"2015","unstructured":"Madureira J, Paci\u00eancia I, Rufo J, Ramos E, Barros H, Teixeira JP, de Oliveira Fernandes E (2015) Indoor air quality in schools and its relationship with children\u2019s respiratory symptoms. Atmos Environ 118:145\u2013156","journal-title":"Atmos Environ"},{"key":"3975_CR40","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1080\/15459624.2015.1116693","volume":"13","author":"JC Maloney","year":"2015","unstructured":"Maloney JC, Thompson MK, Oldham MJ, Stiff CL, Lilly PD, Patskan GJ, Shafer KH, Sarkar MA (2015) Insights from two industrial hygiene pilot e-cigarette passive vaping studies. J Occup Environ Hyg 13:275\u2013283","journal-title":"J Occup Environ Hyg"},{"key":"3975_CR41","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.chroma.2015.07.094","volume":"1410","author":"E Marco","year":"2015","unstructured":"Marco E, Grimalt JO (2015) A rapid method for the chromatographic analysis of volatile organic compounds in exhaled breath of tobacco and electronic cigarette smoke. J Chromatogr A 1410:51\u201359","journal-title":"J Chromatogr A"},{"key":"3975_CR42","first-page":"17","volume-title":"A comprehensive reference book. Air quality monographs","year":"1995","unstructured":"Maroni M, Seifert B, Lindvall T (eds) (1995) A comprehensive reference book. Air quality monographs, vol 3. Elsevier Science B.V, Amsterdam, p 17"},{"key":"3975_CR43","doi-asserted-by":"publisher","first-page":"850","DOI":"10.3109\/08958378.2012.724728","volume":"24","author":"TR McAuley","year":"2012","unstructured":"McAuley TR, Hopke PK, Zhao J, Babaian S (2012) Comparison of the effects of e-cigarette vapor and cigarette smoke on indoor air quality. Inhal Toxicol 24:850\u2013857","journal-title":"Inhal Toxicol"},{"key":"3975_CR44","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1093\/ntr\/ntx058","volume":"19","author":"P Melstrom","year":"2017","unstructured":"Melstrom P, Koszowski B, Thanner MH, Hoh E, King B, Bunell R, McAfee T (2017) Measuring PM2.5, ultrafine particles, nicotine air and wipe samples following the use of electronic cigarettes. Nicotine Tob Res 19:1055\u20131061","journal-title":"Nicotine Tob Res"},{"key":"3975_CR45","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/S0048-9697(97)05435-1","volume":"198","author":"C Minoia","year":"1997","unstructured":"Minoia C, Magnaghi S, Micoli G, Fiorentino ML, Turci R, Angeleri S, Berri A (1997) Determination of environmental reference concentration of six PAHs in urban areas (Pavia, Italy). Sci Total Environ 198:33\u201341","journal-title":"Sci Total Environ"},{"key":"3975_CR46","doi-asserted-by":"publisher","first-page":"3345","DOI":"10.1016\/1352-2310(95)00214-J","volume":"29","author":"S Mitra","year":"1995","unstructured":"Mitra S, Ray B (1995) Patterns and sources of polycylic aromatic hydrocarbons and their derivatives in indoor air. Atmos Environ 29:3345\u20133356","journal-title":"Atmos Environ"},{"key":"3975_CR47","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.envint.2017.04.011","volume":"105","author":"M Mortamais","year":"2017","unstructured":"Mortamais M, Pujol J, van Drooge BL, Maci\u00e0 D, Mart\u00ednez-Vilavella G, Reynes C, Sabatier R, Rivas I, Grimalt JO, Forns J, Alvarez-Pedrerol M, Querol X, Sunyer J (2017) Effect of exposure to polycyclic aromatic hydrocarbons on basal ganglia and attention-deficit hyperactivity disorder symptoms in primary school children. Environ Int 105:12\u201319","journal-title":"Environ Int"},{"key":"3975_CR48","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1021\/es015727h","volume":"36","author":"YY Naumova","year":"2002","unstructured":"Naumova YY, Eisenreich SJ, Turpin BJ, Weisel CP, Morandi MT, Colome SD, Totten LA, Stock TH, Winer AM, Alimokhtari S, Kwon J, Shendell D, Jones J, Maberti S, Wall SJ (2002) Polycyclic aromatic hydrocarbons in the indoor and outdoor air of three cities in the US. Environ Sci Technol 36:2552\u20132559","journal-title":"Environ Sci Technol"},{"key":"3975_CR49","doi-asserted-by":"publisher","first-page":"4889","DOI":"10.3390\/ijerph120504889","volume":"12","author":"G O\u2019Connell","year":"2015","unstructured":"O\u2019Connell G, Colard S, Cahours X, Pritchard J (2015) An assessment of indoor air quality before, during and after unrestricted use of e-cigarettes in a small room. Int J Environ Res Public Health 12:4889\u20134907","journal-title":"Int J Environ Res Public Health"},{"key":"3975_CR50","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1016\/j.partic.2013.02.007","volume":"11","author":"J Pey","year":"2013","unstructured":"Pey J, van Drooge BL, Ripoll A, Moreno T, Grimalt JO, Querol X, Alastuey A (2013) An evaluation of mass, number concentration, chemical composition and types of particles in a cafeteria before and after antismoking law. Particuology 11:527\u2013532","journal-title":"Particuology"},{"key":"3975_CR51","unstructured":"Pisinger C (2015) A systematic review of health effects of electronic cigarettes. WHO. http:\/\/www.who.int\/tobacco\/industry\/product_regulation\/BackgroundPapersENDS3_4November-.pdf . Accessed 14 Dec 2018"},{"key":"3975_CR52","doi-asserted-by":"publisher","unstructured":"Polosa R, Cibella F, Caponnetto P, Maglia M, Prosperini U, Russo C, Tashkin D (2017) Health impact of e-cigarettes: a prospective 3.5-year study of regular daily users who have never smoked. Sci Rep 7:13825. https:\/\/doi.org\/10.1038\/s41598-017-14043-2","DOI":"10.1038\/s41598-017-14043-2"},{"key":"3975_CR53","doi-asserted-by":"publisher","first-page":"2172","DOI":"10.3390\/ijerph15102172","volume":"15","author":"C Protano","year":"2018","unstructured":"Protano C, Avino P, Manigrasso M, Vivaldi V, Perna F, Valeriani F, Vitali M (2018) Environmental electronic vape exposure from four different generations of electronic cigarettes: airborne particulate matter levels. Int J Environ Res Public Health 15:2172. https:\/\/doi.org\/10.3390\/ijerph15102172","journal-title":"Int J Environ Res Public Health"},{"key":"3975_CR54","doi-asserted-by":"publisher","first-page":"S85","DOI":"10.1038\/sj.jea.7500363","volume":"14","author":"GJ Raw","year":"2004","unstructured":"Raw GJ, Coward SK, Brown VM, Crump DR (2004) Exposure to air pollutants in English homes. J Expo Anal Environ Epidemiol 14:S85\u2013S94","journal-title":"J Expo Anal Environ Epidemiol"},{"key":"3975_CR55","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.envint.2014.04.009","volume":"69","author":"I Rivas","year":"2014","unstructured":"Rivas I, Viana M, Moreno T, Pandolfi M, Amato F, Reche C, Bouso L, \u00c0lvarez-Pedrerol M, Alastuey A, Sunyer J, Querol X (2014) Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain. Environ Int 69:200\u2013212","journal-title":"Environ Int"},{"key":"3975_CR56","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1080\/02786826.2017.1300231","volume":"51","author":"AA Rupert","year":"2017","unstructured":"Rupert AA, De Marco C, Saffari A, Pozzi P, Mazza R, Veronese C, Angelloti G, Munarini E, Ogliari AC, Westerdahl D, Hasheminassab S, Shafer MM, Schauer JJ, Repace J, Sioutas C, Boffi R (2017) Environmental pollution and emission factors of electronic cigarettes, heat-not-burn tobacco products, and conventional cigarettes. Aerosol Sci Technol 51:674\u2013684","journal-title":"Aerosol Sci Technol"},{"key":"3975_CR57","doi-asserted-by":"publisher","first-page":"5563","DOI":"10.1016\/j.atmosenv.2003.09.031","volume":"37","author":"K Saarela","year":"2003","unstructured":"Saarela K, Tirkkonen T, Laine-Ylijoki J, Jurvelin J, Nieuwenhuijsen MJ, Jantunen M (2003) Exposure of population and microenvironmental distributions of volatile organic compound concentrations in the EXPOLIS study. Atmos Environ 37:5563\u20135575","journal-title":"Atmos Environ"},{"key":"3975_CR58","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1016\/j.ijheh.2013.11.003","volume":"217","author":"W Schober","year":"2014","unstructured":"Schober W, Szendrei K, Matzen W, Osiander-Fuchs H, Heitmann D, Schettgen T, J\u00f6rres RA, Fromme H (2014) Use of electronic cigarettes (e-cigarettes) impairs indoor air quality and increases FeNO levels of e-cigarette consumers. Int J Hyg Environ Health 217:628\u2013637","journal-title":"Int J Hyg Environ Health"},{"key":"3975_CR59","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1111\/j.1600-0668.2012.00792.x","volume":"23","author":"T Schripp","year":"2013","unstructured":"Schripp T, Markewitz D, Uhde E, Salthammer T (2013) Does e-cigarette consumption cause passive vaping. Indoor Air 23:25\u201331","journal-title":"Indoor Air"},{"key":"3975_CR60","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1080\/15287390600870858","volume":"70","author":"K Sexton","year":"2007","unstructured":"Sexton K, Mongin SJ, Adgate JL, Pratt GC, Ramachandran G, Stock TH, Morandi MT (2007) Estimating volatile organic compound concentrations in selected microenvironments using time\u2013activity and personal exposure data. J Toxicol Environ Health A 70:465\u2013476","journal-title":"J Toxicol Environ Health A"},{"key":"3975_CR61","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1001\/jama.1993.03510040094036","volume":"270","author":"M Siegel","year":"1993","unstructured":"Siegel M (1993) Involuntary smoking in the restaurant workplace. A review of employee exposure and health effects. J Am Med Assoc 270:490\u2013493","journal-title":"J Am Med Assoc"},{"key":"3975_CR62","doi-asserted-by":"publisher","first-page":"9644","DOI":"10.1021\/acs.est.6b01741","volume":"50","author":"M Sleiman","year":"2017","unstructured":"Sleiman M, Logue JM, Montesinos VN, Russell ML, Litter MI, Gundel LA, Destaillats H (2017) Emissions from electronic cigarettes: key parameters affecting the release of harmful chemicals. Environ Sci Technol 50:9644\u20139651","journal-title":"Environ Sci Technol"},{"key":"3975_CR63","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1136\/tobaccocontrol-2015-052772","volume":"26","author":"EK Soule","year":"2017","unstructured":"Soule EK, Maloney SF, Spindie TR, Rudy AK, Hiler MM, Cobb CO (2017) Electronic cigarette use and indoor air quality in a natural setting. Tob Control 26:109\u2013112","journal-title":"Tob Control"},{"key":"3975_CR64","doi-asserted-by":"publisher","first-page":"7735","DOI":"10.5194\/acp-15-7735-2015","volume":"15","author":"BL Drooge van","year":"2015","unstructured":"van Drooge BL, Grimalt JO (2015) Particle size-resolved source apportionment of primary and secondary organic tracer compounds at urban and rural locations in Spain. Atmos Chem Phys 15:7735\u20137752","journal-title":"Atmos Chem Phys"},{"key":"3975_CR65","doi-asserted-by":"publisher","first-page":"4159","DOI":"10.1007\/s11356-012-0890-4","volume":"19","author":"BL Drooge van","year":"2012","unstructured":"van Drooge BL, Lopez JL, Grimalt JO (2012) Influences of natural emission sources (wildfires and Saharan dust) on the urban organic aerosol in Barcelona (Western Mediterranean basis) during a PM event. Environ Sci Pollut Res 19:4159\u20134167","journal-title":"Environ Sci Pollut Res"},{"key":"3975_CR66","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1034\/j.1600-0668.2001.011001049.x","volume":"11","author":"MR Winkle van","year":"2001","unstructured":"van Winkle MR, Scheff PA (2001) Volatile organic compounds, polycyclic aromatic hydrocarbons and elements in the air of ten urban homes. Indoor Air 11:49\u201364","journal-title":"Indoor Air"},{"key":"3975_CR67","doi-asserted-by":"publisher","first-page":"7882","DOI":"10.1016\/j.atmosenv.2006.07.022","volume":"40","author":"E Vartiainen","year":"2006","unstructured":"Vartiainen E, Kulmala M, Ruuskanen TM, Taipale R, Rinne J, Vehkam\u00e4ki H (2006) Formation and growth of indoor air aerosol particles as a result of d-limonene oxidation. Atmos Environ 40:7882\u20137892","journal-title":"Atmos Environ"},{"key":"3975_CR68","doi-asserted-by":"crossref","unstructured":"World Health Organization (1989) Indoor air quality: organic pollutants. Euro reports Studies 111. WHO Regional Office for Europe, Copenhagen https:\/\/newscience.ul.com\/wp-content\/uploads\/2014\/04\/Indoor_Air_Pollution_an_Overview.pdf . Accessed 14 Dec 2018","DOI":"10.1080\/09593338909384805"},{"key":"3975_CR69","unstructured":"World Health Organization (2010) In: World Health Organization Regional Office for Europe (ed) WHO Guidelines for Indoor Air Quality: Selected Pollutants. Copenhagen. http:\/\/www.euro.who.int\/__data\/assets\/pdf_file\/0009\/128169\/e94535.pdf . Accessed 14 Dec 2018"}],"container-title":["Environmental Science and Pollution Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11356-018-3975-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11356-018-3975-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11356-018-3975-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T15:26:38Z","timestamp":1775316398000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11356-018-3975-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12,18]]},"references-count":69,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["3975"],"URL":"https:\/\/doi.org\/10.1007\/s11356-018-3975-x","relation":{},"ISSN":["0944-1344","1614-7499"],"issn-type":[{"value":"0944-1344","type":"print"},{"value":"1614-7499","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,12,18]]},"assertion":[{"value":"2 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 December 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 December 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}