{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T06:56:15Z","timestamp":1789973775403,"version":"4.0.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T00:00:00Z","timestamp":1514937600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1007\/s11517-017-1769-9","type":"journal-article","created":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T02:39:49Z","timestamp":1514947189000},"page":"1315-1324","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Design of a noninvasive and smart hand tremor attenuation system with active control: a simulation study"],"prefix":"10.1007","volume":"56","author":[{"given":"Mahdi","family":"Abbasi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aref","family":"Afsharfard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roya","family":"Arasteh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javad","family":"Safaie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,1,3]]},"reference":[{"issue":"7466","key":"1769_CR1","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1136\/bmj.329.7466.611","volume":"329","author":"MG Baker","year":"2004","unstructured":"Baker MG, Graham L (2004) The journey: Parkinson\u2019s disease. BMJ 329(7466):611\u2013614. https:\/\/doi.org\/10.1136\/bmj.329.7466.611","journal-title":"BMJ"},{"issue":"962","key":"1769_CR2","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1136\/pgmj.2005.032979","volume":"81","author":"R Bhidayasiri","year":"2005","unstructured":"Bhidayasiri R (2005) Differential diagnosis of common tremor syndromes. Postgrad Med J 81(962):756\u2013762. https:\/\/doi.org\/10.1136\/pgmj.2005.032979","journal-title":"Postgrad Med J"},{"key":"1769_CR3","unstructured":"B\u00f3 APL, Poignet P (2010) Tremor attenuation using FES-based joint stiffness control. In: Robotics and Automation (ICRA), 2010 I.E. International Conference on, 2010. IEEE, pp 2928\u20132933"},{"key":"1769_CR4","doi-asserted-by":"publisher","unstructured":"Buki E, Katz R, Zacksenhouse M, Schlesinger I (2017) Vib-bracelet: a passive absorber for attenuating forearm tremor. Med Biol Eng Comp. https:\/\/doi.org\/10.1007\/s11517-017-1742-7","DOI":"10.1007\/s11517-017-1742-7"},{"issue":"1","key":"1769_CR5","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1109\/TMECH.2011.2151204","volume":"18","author":"D Case","year":"2013","unstructured":"Case D, Taheri B, Richer E (2013) Design and characterization of a small-scale magnetorheological damper for tremor suppression. IEEE\/ASME Trans Mechatronics 18(1):96\u2013103. https:\/\/doi.org\/10.1109\/TMECH.2011.2151204","journal-title":"IEEE\/ASME Trans Mechatronics"},{"key":"1769_CR6","first-page":"697","volume":"83","author":"P Crawford","year":"2011","unstructured":"Crawford P, Zimmerman EE (2011) Differentiation and diagnosis of tremor. Am Fam Physician 83:697","journal-title":"Am Fam Physician"},{"issue":"5","key":"1769_CR7","doi-asserted-by":"publisher","first-page":"363","DOI":"10.5014\/ajot.40.5.363","volume":"40","author":"SR Dahlin-Webb","year":"1986","unstructured":"Dahlin-Webb SR (1986) A weighted wrist cuff. Am J Occup Ther 40(5):363\u2013364. https:\/\/doi.org\/10.5014\/ajot.40.5.363","journal-title":"Am J Occup Ther"},{"issue":"Suppl 3","key":"1769_CR8","first-page":"2","volume":"13","author":"G Deuschl","year":"1998","unstructured":"Deuschl G, Bain P, Brin M (1998) Consensus statement of the Movement Disorder Society on tremor. Ad Hoc Scientific Committee. Mov Disord 13(Suppl 3):2\u201323","journal-title":"Mov Disord"},{"key":"1769_CR9","unstructured":"Hall WD (1991) Hand-held gyroscopic device. US Patent 5,058,571, 22 Oct, 1991"},{"issue":"1","key":"1769_CR10","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1007\/bf02351012","volume":"42","author":"SM Hashemi","year":"2004","unstructured":"Hashemi SM, Golnaraghi MF, Patla AE (2004) Tuned vibration absorber for suppression of rest tremor in Parkinson\u2019s disease. Med Biol Eng Comput 42(1):61\u201370. https:\/\/doi.org\/10.1007\/bf02351012","journal-title":"Med Biol Eng Comput"},{"key":"1769_CR11","doi-asserted-by":"publisher","first-page":"29","DOI":"10.3389\/fbioe.2016.00029","volume":"4","author":"G Herrnstadt","year":"2016","unstructured":"Herrnstadt G, Menon C (2016) Voluntary-driven elbow orthosis with speed-controlled tremor suppression. Front Bioeng Biotechnol 4:29\u201338. https:\/\/doi.org\/10.3389\/fbioe.2016.00029","journal-title":"Front Bioeng Biotechnol"},{"key":"1769_CR12","doi-asserted-by":"crossref","unstructured":"Huen D, Liu J, Lo B (2016) An integrated wearable robot for tremor suppression with context aware sensing. In: 2016 I.E. 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN), 2016 IEEE, pp 312\u2013317","DOI":"10.1109\/BSN.2016.7516280"},{"key":"1769_CR13","first-page":"373","volume":"35","author":"J Kotovsky","year":"1998","unstructured":"Kotovsky J, Rosen MJ (1998) A wearable tremor-suppression orthosis. J Rehabil Res Dev 35:373","journal-title":"J Rehabil Res Dev"},{"key":"1769_CR14","doi-asserted-by":"publisher","first-page":"259","DOI":"10.7916\/D8TT4P4B","volume":"4","author":"ED Louis","year":"2014","unstructured":"Louis ED, Ottman R (2014) How many people in the USA have essential tremor? Deriving a population estimate based on epidemiological data. Tremor Other Hyperkinet Mov 4:259. https:\/\/doi.org\/10.7916\/D8TT4P4B","journal-title":"Tremor Other Hyperkinet Mov"},{"key":"1769_CR15","unstructured":"Markiewicz BR (1973) Analysis of the computed-torqae drive method and comparision with the conventional position servo for a computer-controlled manipulator. Technical Memorandum 33\u2013601, Jet Propulsion Laboratory, Pasadena"},{"issue":"9","key":"1769_CR16","doi-asserted-by":"publisher","first-page":"23727","DOI":"10.3390\/s150923727","volume":"15","author":"M Memedi","year":"2015","unstructured":"Memedi M, Sadikov A, Groznik V, \u017dabkar J, Mo\u017eina M, Bergquist F, Johansson A, Haubenberger D, Nyholm D (2015) Automatic spiral analysis for objective assessment of motor symptoms in Parkinson\u2019s disease. Sensors 15(9):23727\u201323744. https:\/\/doi.org\/10.3390\/s150923727","journal-title":"Sensors"},{"key":"1769_CR17","doi-asserted-by":"crossref","unstructured":"Mojica JW, Kumagai A, Marsh S (2013) Vibration suppression drafting arm for tremor patients. In: ASME 2013 International Mechanical Engineering Congress and Exposition, 2013. American Society of Mechanical Engineers, pp V015T016A008-V015T016A008","DOI":"10.1115\/IMECE2013-65217"},{"key":"1769_CR18","doi-asserted-by":"crossref","unstructured":"Niazmand K, Tonn K, Kalaras A, Fietzek UM, Mehrkens J-H, Lueth TC (2011) Quantitative evaluation of Parkinson\u2019s disease using sensor based smart glove. In: Computer-Based Medical Systems (CBMS), 2011 24th International Symposium on, 2011 IEEE, pp 1\u20138","DOI":"10.1109\/CBMS.2011.5999113"},{"key":"1769_CR19","doi-asserted-by":"crossref","unstructured":"Ohara E, Yano Ki, Horihata S, Aoki T, Nishimoto Y (2009) Tremor suppression control of meal-assist robot with adaptive filter. In: 2009 I.E. International Conference on Rehabilitation Robotics, 2009. IEEE, pp 498\u2013503","DOI":"10.1109\/ICORR.2009.5209565"},{"key":"1769_CR20","doi-asserted-by":"crossref","unstructured":"Ou C, Gouldstone A, Jaeger BK, Sipahi R (2015) Control design for a hand tremor suppression pen. In: ASME 2015 Dynamic Systems and Control Conference, 2015. American Society of Mechanical Engineers, pp V002T036A006-V002T036A006","DOI":"10.1115\/DSCC2015-9962"},{"key":"1769_CR21","doi-asserted-by":"crossref","DOI":"10.3109\/9781420019995","volume-title":"Handbook of Parkinson\u2019s disease","author":"R Pahwa","year":"2007","unstructured":"Pahwa R, Lyons KE (2007) Handbook of Parkinson\u2019s disease. CRC Press, Boca Raton"},{"issue":"6","key":"1769_CR22","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1002\/mds.25796","volume":"29","author":"A Pathak","year":"2014","unstructured":"Pathak A, Redmond JA, Allen M, Chou KL (2014) A noninvasive handheld assistive device to accommodate essential tremor: a pilot study. Mov Disord 29(6):838\u2013842. https:\/\/doi.org\/10.1002\/mds.25796","journal-title":"Mov Disord"},{"key":"1769_CR23","doi-asserted-by":"crossref","unstructured":"Pierleoni P, Palma L, Belli A, Pernini L (2014) A real-time system to aid clinical classification and quantification of tremor in Parkinson\u2019s disease. In: Biomedical and Health Informatics (BHI), 2014 IEEE-EMBS International Conference on, 2014 IEEE, pp 113\u2013116","DOI":"10.1109\/BHI.2014.6864317"},{"issue":"10","key":"1769_CR24","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1007\/s11517-011-0803-6","volume":"49","author":"L Popovi\u0107 Maneski","year":"2011","unstructured":"Popovi\u0107 Maneski L, Jorgovanovi\u0107 N, Ili\u0107 V, Do\u0161en S, Keller T, Popovi\u0107 MB, Popovi\u0107 DB (2011) Electrical stimulation for the suppression of pathological tremor. Med Biol Eng Comput 49(10):1187\u20131193. https:\/\/doi.org\/10.1007\/s11517-011-0803-6","journal-title":"Med Biol Eng Comput"},{"issue":"5","key":"1769_CR25","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1007\/s12206-014-0104-8","volume":"28","author":"M Rahnavard","year":"2014","unstructured":"Rahnavard M, Hashemi M, Farahmand F, Dizaji AF (2014) Designing a hand rest tremor dynamic vibration absorber using H2 optimization method. J Mech Sci Technol 28(5):1609\u20131614. https:\/\/doi.org\/10.1007\/s12206-014-0104-8","journal-title":"J Mech Sci Technol"},{"issue":"9","key":"1769_CR26","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1007\/s11517-008-0369-0","volume":"46","author":"SM Rissanen","year":"2008","unstructured":"Rissanen SM, Kankaanp\u00e4\u00e4 M, Meigal A, Tarvainen MP, Nuutinen J, Tarkka IM, Airaksinen O, Karjalainen PA (2008) Surface EMG and acceleration signals in Parkinson\u2019s disease: feature extraction and cluster analysis. Med Biol Eng Comput 46(9):849\u2013858. https:\/\/doi.org\/10.1007\/s11517-008-0369-0","journal-title":"Med Biol Eng Comput"},{"issue":"3","key":"1769_CR27","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1109\/TNSRE.2007.903917","volume":"15","author":"E Rocon","year":"2007","unstructured":"Rocon E, Belda-Lois JM, Ruiz AF, Manto M, Moreno JC, Pons JL (2007) Design and validation of a rehabilitation robotic exoskeleton for tremor assessment and suppression. IEEE Trans Neural Syst Rehabil Eng 15(3):367\u2013378. https:\/\/doi.org\/10.1109\/TNSRE.2007.903917","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1769_CR28","doi-asserted-by":"crossref","unstructured":"Rocon E, Gallego J, Barrios L, Victoria A, Ibanez J, Farina D, Negro F, Dideriksen JL, Conforto S, D'Alessio T (2010) Multimodal BCI-mediated FES suppression of pathological tremor. In: 2010 annual international conference of the IEEE engineering in medicine and biology, 2010. IEEE, pp 3337\u20133340","DOI":"10.1109\/IEMBS.2010.5627914"},{"key":"1769_CR29","first-page":"1","volume":"32","author":"MJ Rosen","year":"1995","unstructured":"Rosen MJ, Arnold AS, Baiges IJ, Aisen ML, Eglowstein SR (1995) Design of a controlled-energy-dissipation orthosis (CEDO) for functional suppression of intention tremors. J Rehabil Res Dev 32:1","journal-title":"J Rehabil Res Dev"},{"issue":"2","key":"1769_CR30","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1109\/TBME.2006.886670","volume":"54","author":"A Salarian","year":"2007","unstructured":"Salarian A, Russmann H, Wider C, Burkhard PR, Vingerhoets FJ, Aminian K (2007) Quantification of tremor and bradykinesia in Parkinson\u2019s disease using a novel ambulatory monitoring system. IEEE Trans Biomed Eng 54(2):313\u2013322. https:\/\/doi.org\/10.1109\/TBME.2006.886670","journal-title":"IEEE Trans Biomed Eng"},{"issue":"2","key":"1769_CR31","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1109\/TNSRE.2013.2295034","volume":"22","author":"B Taheri","year":"2014","unstructured":"Taheri B, Case D, Richer E (2014) Robust controller for tremor suppression at musculoskeletal level in human wrist. IEEE Trans Neural Syst Rehabil Eng 22(2):379\u2013388. https:\/\/doi.org\/10.1109\/TNSRE.2013.2295034","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1769_CR32","doi-asserted-by":"publisher","unstructured":"Teixeira CJ, Bicho E, Rocha LA, Gago MF (2013) A self-tunable dynamic vibration absorber: Parkinson\u2019s disease\u2019s tremor suppression. In: Bioengineering (ENBENG), 2013 I.E. 3rd Portuguese Meeting in, 20\u201323 Feb. 2013 2013. pp 1\u20136. https:\/\/doi.org\/10.1109\/ENBENG.2013.6518440","DOI":"10.1109\/ENBENG.2013.6518440"},{"issue":"2","key":"1769_CR33","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.jneumeth.2008.03.009","volume":"171","author":"H Wang","year":"2008","unstructured":"Wang H, Yu Q, Kurtis MM, Floyd AG, Smith WA, Pullman SL (2008) Spiral analysis\u2014improved clinical utility with center detection. J Neurosci Methods 171(2):264\u2013270. https:\/\/doi.org\/10.1016\/j.jneumeth.2008.03.009","journal-title":"J Neurosci Methods"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11517-017-1769-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-017-1769-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-017-1769-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,11]],"date-time":"2022-08-11T18:31:58Z","timestamp":1660242718000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11517-017-1769-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,3]]},"references-count":33,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["1769"],"URL":"https:\/\/doi.org\/10.1007\/s11517-017-1769-9","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,3]]}}}