{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T18:26:32Z","timestamp":1785435992528,"version":"3.56.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T00:00:00Z","timestamp":1748217600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T00:00:00Z","timestamp":1748217600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["62103299"],"award-info":[{"award-number":["62103299"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Program of Graduate Education and Teaching Reform in Tianjin University of Technology","award":["ZDXM2022"],"award-info":[{"award-number":["ZDXM2022"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2025,10]]},"DOI":"10.1007\/s11517-025-03374-2","type":"journal-article","created":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T07:03:43Z","timestamp":1748243023000},"page":"3067-3082","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Passive haptic interface for robot-assisted endovascular catheterization"],"prefix":"10.1007","volume":"63","author":[{"given":"Yu","family":"Song","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liutao","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7814-4483","authenticated-orcid":false,"given":"Zhiwei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,26]]},"reference":[{"issue":"1","key":"3374_CR1","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1002\/rcs.1650","volume":"12","author":"WS Lu","year":"2016","unstructured":"Lu WS, Xu WY, Pan F, Liu D, Tian ZM, Zeng Y (2016) Clinical application of a vascular interventional robot in cerebral angiography. Int J Med Robot Comput Assist Surg 12(1):132\u2013136. https:\/\/doi.org\/10.1002\/rcs.1650","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"4","key":"3374_CR2","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.1007\/s00464-018-6079-2","volume":"32","author":"BS Peters","year":"2018","unstructured":"Peters BS, Armijo PR, Krause C, Choudhury SA, Oleynikov D (2018) Review of emerging surgical robotic technology. Surg Endosc 32(4):1636\u20131655. https:\/\/doi.org\/10.1007\/s00464-018-6079-2","journal-title":"Surg Endosc"},{"issue":"4","key":"3374_CR3","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.21037\/qims-21-792.PMID:35371939;PMCID:PMC8923856","volume":"12","author":"Y Zhao","year":"2022","unstructured":"Zhao Y, Mei Z, Luo X, Mao J, Zhao Q, Liu G, Wu D (2022) Remote vascular interventional surgery robotics: a literature review. Quant Imaging Med Surg 12(4):2552\u20132574. https:\/\/doi.org\/10.21037\/qims-21-792.PMID:35371939;PMCID:PMC8923856","journal-title":"Quant Imaging Med Surg"},{"issue":"3","key":"3374_CR4","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s13367-021-0017-x","volume":"33","author":"SM Mohtasim","year":"2021","unstructured":"Mohtasim SM, Ahammed R, Rahman MM, Rashid MM, Roy R, Aziz MA (2021) Recent developments of regenerative magnetorheological (RMR) damper: a review. Korea Australia Rheol J 33(3):201\u2013224. https:\/\/doi.org\/10.1007\/s13367-021-0017-x","journal-title":"Korea Australia Rheol J"},{"key":"3374_CR5","doi-asserted-by":"publisher","unstructured":"Hwang J, Young Kim J, Choi H (Jan 2020) A review of magnetic actuation systems and magnetically actuated guidewire- and catheter-based microrobots for vascular interventions. Intell Serv Robot 13(1). https:\/\/doi.org\/10.1007\/s11370-020-00311-0","DOI":"10.1007\/s11370-020-00311-0"},{"issue":"4","key":"3374_CR6","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s10439-013-0946-8","volume":"42","author":"H Rafii-Tari","year":"2014","unstructured":"Rafii-Tari H, Payne CJ, Yang GZ (2014) Current and emerging robot-assisted endovascular catheterization technologies: a review. Ann Biomed Eng 42(4):697\u2013715. https:\/\/doi.org\/10.1007\/s10439-013-0946-8","journal-title":"Ann Biomed Eng"},{"key":"3374_CR7","doi-asserted-by":"crossref","unstructured":"Payne CJ, Rafii-Tari H, Yang GZ (2012) A force feedback system for endovascular catheterization. IEEE International Conference on Intelligent Robots and Systems, pp 1298\u20131304","DOI":"10.1109\/IROS.2012.6386149"},{"issue":"5","key":"3374_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/rcs.2109","volume":"16","author":"K Wang","year":"2020","unstructured":"Wang K, Mai X, Xu H, Lu Q, Yan W (2020) A novel SEA-based haptic force feedback master hand controller for robotic endovascular intervention system. Int J Med Robot Comput Assist Surg 16(5):1\u201310. https:\/\/doi.org\/10.1002\/rcs.2109","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"7","key":"3374_CR9","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1177\/1538574420940832","volume":"54","author":"Q Lu","year":"2020","unstructured":"Lu Q, Shen Y, Xia S, Chen B, Wang K (2020) A novel universal endovascular robot for peripheral arterial stent\u2013assisted angioplasty: initial experimental results. Vasc Endovasc Surg 54(7):598\u2013604. https:\/\/doi.org\/10.1177\/1538574420940832","journal-title":"Vasc Endovasc Surg"},{"issue":"1","key":"3374_CR10","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s11548-020-02278-w","volume":"16","author":"K Wang","year":"2021","unstructured":"Wang K, Liu J, Yan W, Lu Q, Nie S (2021) Force feedback controls of multi-gripper robotic endovascular intervention: design, prototype, and experiments. Int J Comput Assist Radiol Surg 16(1):179\u2013192. https:\/\/doi.org\/10.1007\/s11548-020-02278-w","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"9","key":"3374_CR11","doi-asserted-by":"publisher","first-page":"1606","DOI":"10.1177\/0954406213508935","volume":"228","author":"S-R Lee","year":"2014","unstructured":"Lee S-R, Uhm C-H, Seong M-S, Oh J-S, Choi S-B (2014) Repulsive force control of minimally invasive surgery robot associated with three degrees of freedom electrorheological fluid-based haptic master. Proc Inst Mech Eng C J Mech Eng Sci 228(9):1606\u20131621. https:\/\/doi.org\/10.1177\/0954406213508935","journal-title":"Proc Inst Mech Eng C J Mech Eng Sci"},{"issue":"12","key":"3374_CR12","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1177\/1045389X07083132","volume":"18","author":"Y-M Han","year":"2007","unstructured":"Han Y-M, Kang P-S, Sung K-G, Choi S-B (2007) Force feedback control of a medical haptic master using an electrorheological fluid. J Intell Mater Syst Struct 18(12):1149\u20131154. https:\/\/doi.org\/10.1177\/1045389X07083132","journal-title":"J Intell Mater Syst Struct"},{"key":"3374_CR13","doi-asserted-by":"publisher","first-page":"611","DOI":"10.3390\/app11020611","volume":"11","author":"H Yu","year":"2021","unstructured":"Yu H et al (2021) A novel vascular intervention surgical robot based on force feedback and flexible clamping. Appl Sci 11:611. https:\/\/doi.org\/10.3390\/app11020611","journal-title":"Appl Sci"},{"issue":"1","key":"3374_CR14","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1109\/TMECH.2015.2429140","volume":"21","author":"N Najmaei","year":"2016","unstructured":"Najmaei N, Asadian A, Kermani MR, Patel RV (2016) Design and performance evaluation of a prototype MRF-based haptic interface for medical applications. IEEE\/ASME Trans Mechatron 21(1):110\u2013121. https:\/\/doi.org\/10.1109\/TMECH.2015.2429140","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"2","key":"3374_CR15","doi-asserted-by":"publisher","first-page":"696","DOI":"10.1109\/TMECH.2014.2317714","volume":"20","author":"W Li","year":"2015","unstructured":"Li W, Yadmellat P, Kermani MR (2015) Linearized torque actuation using FPGA-controlled magnetorheological actuators. IEEE\/ASME Trans Mechatron 20(2):696\u2013704. https:\/\/doi.org\/10.1109\/TMECH.2014.2317714","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"3","key":"3374_CR16","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1109\/TRO.2019.2896763","volume":"35","author":"S Guo","year":"2019","unstructured":"Guo S et al (2019) A novel robot-assisted endovascular catheterization system with haptic force feedback. IEEE Trans Rob 35(3):685\u2013696. https:\/\/doi.org\/10.1109\/TRO.2019.2896763","journal-title":"IEEE Trans Rob"},{"issue":"2","key":"3374_CR17","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1109\/TMECH.2015.2489219","volume":"21","author":"X Yin","year":"2016","unstructured":"Yin X, Guo S, Xiao N, Tamiya T, Hirata H, Ishihara H (2016) Safety operation consciousness realization of a MR fluids-based novel haptic interface for teleoperated catheter minimally invasive neurosurgery. IEEE\/ASME Trans Mechatron 21(2):1043\u20131054. https:\/\/doi.org\/10.1109\/TMECH.2015.2489219","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"3374_CR18","doi-asserted-by":"publisher","unstructured":"Song Y et al (Jun 2018) Performance evaluation of a robot-assisted catheter operating system with haptic feedback. Biomed Microdevices 20(2). https:\/\/doi.org\/10.1007\/s10544-018-0294-4","DOI":"10.1007\/s10544-018-0294-4"},{"key":"3374_CR19","doi-asserted-by":"publisher","unstructured":"Yin X, Guo S, Song Y (2018) Magnetorheological fluids actuated haptic-based teleoperated catheter operating system. Micromachines (Basel) 9(9). https:\/\/doi.org\/10.3390\/mi9090465","DOI":"10.3390\/mi9090465"},{"key":"3374_CR20","doi-asserted-by":"publisher","unstructured":"Eshgarf H, Ahmadi Nadooshan A, Raisi A (Jun 2022) An overview on properties and applications of magnetorheological fluids: dampers, batteries, valves and brakes. J Energy Storage 50. https:\/\/doi.org\/10.1016\/j.est.2022.104648","DOI":"10.1016\/j.est.2022.104648"},{"key":"3374_CR21","doi-asserted-by":"publisher","unstructured":"Zhang Y, Li D, Cui H, Yang J (Apr 2020) A new modified model for the rheological properties of magnetorheological fluids based on different magnetic field. J Magn Magn Mater 500. https:\/\/doi.org\/10.1016\/j.jmmm.2019.166377","DOI":"10.1016\/j.jmmm.2019.166377"},{"issue":"5","key":"3374_CR22","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1007\/s40846-018-0453-3","volume":"39","author":"Y Wang","year":"2019","unstructured":"Wang Y, Guo S, Xiao N, Li Y, Jiang Y (2019) Surgeons\u2019 operation skill-based control strategy and preliminary evaluation for a vascular interventional surgical robot. J Med Biol Eng 39(5):653\u2013664. https:\/\/doi.org\/10.1007\/s40846-018-0453-3","journal-title":"J Med Biol Eng"},{"key":"3374_CR23","doi-asserted-by":"publisher","unstructured":"Gao Q, Zhan Y, Song Y, Liu J, Wu J (2021) An MR fluid based master manipulator of the vascular intervention robot with haptic feedback. 2021 IEEE international conference on mechatronics and automation (ICMA), Takamatsu, Japan, pp 158-163. https:\/\/doi.org\/10.1109\/ICMA52036.2021.9512709","DOI":"10.1109\/ICMA52036.2021.9512709"},{"issue":"9","key":"3374_CR24","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1177\/1045389X12447984","volume":"23","author":"H Sahin","year":"2012","unstructured":"Sahin H, Gordaninejad F, Wang X, Liu Y (2012) Response time of magnetorheological fluids and magnetorheological valves under various flow conditions. J Intell Mater Syst Struct 23(9):949\u2013957. https:\/\/doi.org\/10.1177\/1045389X12447984","journal-title":"J Intell Mater Syst Struct"},{"issue":"14","key":"3374_CR25","doi-asserted-by":"publisher","first-page":"1920","DOI":"10.1177\/1045389X15586449","volume":"26","author":"M Eshaghi","year":"2015","unstructured":"Eshaghi M, Sedaghati R, Rakheja S (2015) The effect of magneto-rheological fluid on vibration suppression capability of adaptive sandwich plates: experimental and finite element analysis. J Intell Mater Syst Struct 26(14):1920\u20131935. https:\/\/doi.org\/10.1177\/1045389X15586449","journal-title":"J Intell Mater Syst Struct"},{"key":"3374_CR26","doi-asserted-by":"publisher","unstructured":"Omisore OM et al (2020) Design of a master-slave robotic system for intravascular catheterization during cardiac interventions,\"\u00a02020 16th International Conference on Control, Automation, Robotics and Vision (ICARCV), Shenzhen, China, pp 996\u20131000. https:\/\/doi.org\/10.1109\/ICARCV50220.2020.9305413","DOI":"10.1109\/ICARCV50220.2020.9305413"},{"issue":"6","key":"3374_CR27","doi-asserted-by":"publisher","first-page":"1786","DOI":"10.1109\/TBME.2022.3227734","volume":"70","author":"G Dagnino","year":"2023","unstructured":"Dagnino G et al (2023) In-vivo validation of a novel robotic platform for endovascular intervention. IEEE Trans Biomedl Eng 70(6):1786\u20131794. https:\/\/doi.org\/10.1109\/TBME.2022.3227734","journal-title":"IEEE Trans Biomedl Eng"},{"issue":"6","key":"3374_CR28","doi-asserted-by":"publisher","first-page":"531","DOI":"10.3758\/BF03212187","volume":"49","author":"XD Pang","year":"1991","unstructured":"Pang XD, Tan HZ, Durlach NI (1991) Manual discrimination of force using active finger motion. Percept Psychophys 49(6):531\u2013540. https:\/\/doi.org\/10.3758\/BF03212187","journal-title":"Percept Psychophys"},{"key":"3374_CR29","doi-asserted-by":"publisher","unstructured":"Bao X, Guo S, Xiao N, Li Y, Yang C, Jiang Y (Mar 2018) A cooperation of catheters and guidewires-based novel remote-controlled vascular interventional robot. Biomed Microdevices 20(1). https:\/\/doi.org\/10.1007\/s10544-018-0261-0","DOI":"10.1007\/s10544-018-0261-0"},{"issue":"7","key":"3374_CR30","doi-asserted-by":"publisher","first-page":"584","DOI":"10.3390\/s23073584","volume":"23","author":"Y Song","year":"2023","unstructured":"Song Y, Li L, Tian Y, Li Z, Yin X (2023) A novel master\u2013slave interventional surgery robot with force feedback and collaborative operation. Sensors 23(7):584. https:\/\/doi.org\/10.3390\/s23073584","journal-title":"Sensors"},{"key":"3374_CR31","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.triboint.2018.03.012","volume":"123","author":"X Zhou","year":"2018","unstructured":"Zhou X et al (2018) Correlation between tactile perception and tribological and dynamical properties for human finger under different sliding speeds. Tribol Int 123:286\u2013295. https:\/\/doi.org\/10.1016\/j.triboint.2018.03.012","journal-title":"Tribol Int"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03374-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-025-03374-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-025-03374-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T17:02:51Z","timestamp":1757955771000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-025-03374-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,26]]},"references-count":31,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["3374"],"URL":"https:\/\/doi.org\/10.1007\/s11517-025-03374-2","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,26]]},"assertion":[{"value":"16 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}