{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T08:39:04Z","timestamp":1786523944529,"version":"build-2736575974"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T00:00:00Z","timestamp":1782691200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T00:00:00Z","timestamp":1782691200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52475024"],"award-info":[{"award-number":["52475024"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Key Technology Breakthrough Plan Project of Science and Innovation Yongjiang 2035","award":["2024Z202"],"award-info":[{"award-number":["2024Z202"]}]},{"name":"Key R&D and Achievement Transformation Plan of the Inner Mongolia Autonomous Region Science and Technology Department","award":["2025YFHH0285"],"award-info":[{"award-number":["2025YFHH0285"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Med Biol Eng Comput"],"published-print":{"date-parts":[[2026,7]]},"DOI":"10.1007\/s11517-026-03617-w","type":"journal-article","created":{"date-parts":[[2026,6,29]],"date-time":"2026-06-29T09:47:04Z","timestamp":1782726424000},"page":"2731-2746","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Enhanced puncture event detection for teleoperated needle insertion robotic system"],"prefix":"10.1007","volume":"64","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2420-3104","authenticated-orcid":false,"given":"Hongbing","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yubin","family":"Lan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuling","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linlong","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,29]]},"reference":[{"key":"3617_CR1","doi-asserted-by":"crossref","unstructured":"Belien J, Swinnen S, D'hondt R et al (2024) CHIT1 at diagnosis predicts faster disability progression and reflects early microglial activation in multiple sclerosis. Nuature Commnunications 15:5013","DOI":"10.1038\/s41467-024-49312-y"},{"key":"3617_CR2","doi-asserted-by":"crossref","unstructured":"Ronsley R, Karvonen K, Cole B et al (2024) Detection of tumor-derived cell-free DNA in cerebrospinal fluid using a clinically validated targeted sequencing panel for pediatric brain tumors. J Neuro-Oncol 168:215\u2013224","DOI":"10.1007\/s11060-024-04645-y"},{"issue":"11","key":"3617_CR3","doi-asserted-by":"publisher","first-page":"1638","DOI":"10.1093\/cid\/ciu641","volume":"59","author":"S Marais","year":"2014","unstructured":"Marais S, Wilkinson K, Lesosky M et al (2014) Neutrophil-associated central nervous system inflammation in tuberculous meningitis immune reconstitution inflammatory syndrome. Clin Infect Dis 59(11):1638\u20131647","journal-title":"Clin Infect Dis"},{"key":"3617_CR4","doi-asserted-by":"crossref","unstructured":"Callaghan B, Price R, Chen K et al (2015) The importance of rare subtypes in diagnosis and treatment of peripheral neuropathy A review. JAMA Neurol 72(12):1510\u20131518","DOI":"10.1001\/jamaneurol.2015.2347"},{"issue":"13","key":"3617_CR5","doi-asserted-by":"publisher","DOI":"10.3390\/s23136065","volume":"23","author":"M Althobaiti","year":"2023","unstructured":"Althobaiti M, Ali S, Hariri N et al (2023) Recent advances in smart epidural spinal needles. Sensors 23(13):6065","journal-title":"Sensors"},{"key":"3617_CR6","doi-asserted-by":"crossref","unstructured":"Kammerer P, Staedt H, Wesslau K et al (2024) The bevel effect: a prospective, randomized investigation into needle design in dental intraligamentary anesthesia. Clin Oral Inv 28(3):170","DOI":"10.1007\/s00784-024-05546-0"},{"issue":"2","key":"3617_CR7","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.2226","volume":"17","author":"H Li","year":"2021","unstructured":"Li H, Wang Y, Li Y, Zhang J (2021) A novel manipulator with needle insertion forces feedback for robot-assisted lumbar puncture. Int J Med Robot Comput Assist Surg 17(2):e2226","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"6","key":"3617_CR8","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.2572","volume":"19","author":"M Rios-Hernandez","year":"2023","unstructured":"Rios-Hernandez M, Jacinto-Villegas J, Zemiti N et al (2023) Development of a lumbar puncture virtual simulator for medical students training: a preliminary evaluation. Int J Med Robot Comput Assist Surg 19(6):e2572","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"3617_CR9","volume":"9","author":"E Alexander","year":"2025","unstructured":"Alexander E, Elkamel A, Worrell S (2025) Advances in minimally invasive esophagectomy (MIE): techniques, outcomes, and future directions. Mini-invasive Surg 9:e22","journal-title":"Mini-invasive Surg"},{"key":"3617_CR10","doi-asserted-by":"crossref","unstructured":"Reis AE, Spano M, Davis-Hayes C, Salama GR (2024) Lumbar puncture complications: a review of current literature. Curr Pain Headache Rep 28:803\u2013813","DOI":"10.1007\/s11916-024-01262-2"},{"key":"3617_CR11","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2023.1293689","volume":"10","author":"Y Zhuang","year":"2024","unstructured":"Zhuang Y, Xie H, Chen J et al (2024) Computer-modified paramedian approach technique reduces failures and alleviates pain in lumbar puncture: a prospective comparative study. Front Med 10:1293689","journal-title":"Front Med"},{"issue":"1","key":"3617_CR12","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1109\/LRA.2017.2768123","volume":"18","author":"T Lehmann","year":"2018","unstructured":"Lehmann T, Sloboda R, Usmani N, Tavakoli M (2018) Human-machine collaboration modalities for semi-automated needle insertion into soft tissue. IEEE Robot Autom Lett 18(1):477\u2013483","journal-title":"IEEE Robot Autom Lett"},{"key":"3617_CR13","doi-asserted-by":"crossref","unstructured":"Li H, Nie X, Duan D et al (2022) An admittance-controlled amplified force tracking scheme for collaborative lumbar puncture surgical robot system. Int J Med Robot Comput Assist Surg 18(5):e2428","DOI":"10.1002\/rcs.2428"},{"key":"3617_CR14","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/accefa","volume":"68","author":"M Bernardes","year":"2023","unstructured":"Bernardes M, Moreira P, Mareschal L et al (2023) Data-driven adaptive needle insertion assist for transperineal prostate interventions. Phys Med Biol 68:105016","journal-title":"Phys Med Biol"},{"issue":"9","key":"3617_CR15","doi-asserted-by":"publisher","first-page":"1154","DOI":"10.1177\/0278364909101408","volume":"28","author":"O Piccin","year":"2009","unstructured":"Piccin O, Barbe L, Bayle B, de Mathelin M (2009) A force feedback teleoperated needle insertion device for percutaneous procedures. Int J Robot Res 28(9):1154\u20131168","journal-title":"Int J Robot Res"},{"key":"3617_CR16","doi-asserted-by":"crossref","unstructured":"Aggravi M, Estima D, Kurpa A et al (2021) Haptic teleoperation of flexible needles combining 3D ultrasound guidance and needle tip force feedback. IEEE Robot Autom Lett 6(3):4859\u20134866","DOI":"10.1109\/LRA.2021.3068635"},{"key":"3617_CR17","doi-asserted-by":"crossref","unstructured":"Tran D, Hor K, Kamani A et al (2009) Instrumentation of the Loss-of-Resistance technique for epidural needle insertion. IEEE Trans Biomed Eng 56(3):820\u2013827","DOI":"10.1109\/TBME.2008.2011475"},{"key":"3617_CR18","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.jclinane.2017.01.017","volume":"38","author":"L Carvalho","year":"2017","unstructured":"Carvalho L, Agarwal A, Kashiwagi F et al (2017) Commonly-used versus less commonly-used methods in the loss of resistance technique for identification of the epidural space: a systematic review and meta-analysis of randomized controlled trials. J Clin Anesth 38:41\u201351","journal-title":"J Clin Anesth"},{"key":"3617_CR19","doi-asserted-by":"crossref","unstructured":"Carotenuto B, Micco A, Ricciardi A et al (2017) Optical guidance systems for epidural space identification. IEEE J Sel Topics Quantum Electron 23(2):6900309","DOI":"10.1109\/JSTQE.2016.2600027"},{"key":"3617_CR20","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1109\/TRO.2023.3344027","volume":"40","author":"C Pacchierotti","year":"2024","unstructured":"Pacchierotti C, Prattichizzo D (2024) Cutaneous\/tactile haptic feedback in robotic teleoperation: motivation, survey, and perspectives. IEEE Trans Robot 40:978\u2013998","journal-title":"IEEE Trans Robot"},{"key":"3617_CR21","doi-asserted-by":"crossref","unstructured":"Gildenberg P, Zanes C, Flitter M et al (1969) Impedance measuring device for detection of penetration of the spinal cord in anterior percutaneous cervical cordotomy. J Neurosurg 30(1):87\u201392","DOI":"10.3171\/jns.1969.30.1.0087"},{"issue":"1","key":"3617_CR22","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1109\/4233.826856","volume":"4","author":"P Brett","year":"2000","unstructured":"Brett P, Harrison A, Thomas T (2000) Schemes for the identification of tissue types and boundaries at the tool point for surgical needles. IEEE Trans Inf Technol Biomed 4(1):30\u201336","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"3617_CR23","doi-asserted-by":"crossref","unstructured":"Washio T, Chinzei K (2004) Needle force sensor, robust and sensitive detection of the instant of needle puncture. In: Barillot C, Haynor DR, Hellier P (eds) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2004, 7th International Conference Saint-Malo, France, September 26-29, 2004, Proceedings, Part II of Lecture Notes in Computer Science, vol 3217. Springer, pp 113\u2013120","DOI":"10.1007\/978-3-540-30136-3_15"},{"issue":"10","key":"3617_CR24","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura AM, Simone C, O\u2019Leary MD (2004) Force modeling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51(10):1707\u20131716","journal-title":"IEEE Trans Biomed Eng"},{"issue":"2","key":"3617_CR25","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1007\/BF02345961","volume":"43","author":"H Saito","year":"2005","unstructured":"Saito H, Togawa T (2005) Detection of needle puncture to blood vessel using puncture force measurement. Med Biol Eng Comput 43(2):240\u2013247","journal-title":"Med Biol Eng Comput"},{"issue":"6","key":"3617_CR26","doi-asserted-by":"publisher","first-page":"3018","DOI":"10.1109\/TMECH.2015.2410287","volume":"20","author":"T Osa","year":"2015","unstructured":"Osa T, Abawi C, Sugita N et al (2015) Hand-held bone cutting tool with autonomous penetration detection for spinal surgery. IEEE ASME Trans Mechatron 20(6):3018\u20133027","journal-title":"IEEE ASME Trans Mechatron"},{"key":"3617_CR27","unstructured":"Guo J, Kil I, Groff RE, Singapogu RB (2019) Automatic detection of needle puncture in a simulated cannulation task, Int Symp Med Robotics (ISMR), Atlanta, GA, USA"},{"key":"3617_CR28","doi-asserted-by":"crossref","unstructured":"Liang X, Yan Y, Wang W et al (2024) Adaptive human-robot interaction torque estimation with high accuracy and strong tracking capability for a lower-limb rehabilitation robot. IEEE\/ASME Trans Mechatron 29(6):4814\u20134825","DOI":"10.1109\/TMECH.2024.3394491"},{"key":"3617_CR29","doi-asserted-by":"publisher","first-page":"4130","DOI":"10.1109\/TASE.2026.3653476","volume":"23","author":"T Su","year":"2026","unstructured":"Su T, Zhang Y, Liang X, Ma N (2026) Trajectory planning method for fracture reduction of parallel robots based on DMP and APF. IEEE Trans Autom Sci Eng 23:4130\u20134141","journal-title":"IEEE Trans Autom Sci Eng"},{"issue":"2","key":"3617_CR30","doi-asserted-by":"publisher","first-page":"419","DOI":"10.20517\/ir.2025.21","volume":"5","author":"X Wang","year":"2025","unstructured":"Wang X, Xie D, Li Y, Tian J, Li K (2025) Extended fault-pair Boolean table based test points selection for robotic systems. Intelligence & Robotics 5(2):419\u2013432","journal-title":"Intelligence & Robotics"},{"key":"3617_CR31","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-12950-7","volume":"12","author":"C Wang","year":"2022","unstructured":"Wang C, Calle P, Reynolds J et al (2022) Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning. Sci Rep 12:9057","journal-title":"Sci Rep"},{"key":"3617_CR32","doi-asserted-by":"crossref","unstructured":"Alamdar A, Patel N, Urias U et al (2022) Force and velocity based puncture detection in robot assisted retinal vein cannulation: In-vivo study. IEEE Trans Biomed Eng 69(3):1123\u20131132","DOI":"10.1109\/TBME.2021.3114638"},{"issue":"10","key":"3617_CR33","doi-asserted-by":"publisher","first-page":"1979","DOI":"10.1177\/01423312211069355","volume":"44","author":"Y Wang","year":"2022","unstructured":"Wang Y, Li H (2022) Penetration detection with intention recognition for cooperatively controlled robotic needle insertion. Trans Inst Meas Control 44(10):1979\u20131992","journal-title":"Trans Inst Meas Control"},{"issue":"1","key":"3617_CR34","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1109\/LRA.2023.3333236","volume":"9","author":"Y Li","year":"2024","unstructured":"Li Y, Li H (2024) Penetration event identification based on neural network for needle tip location in robot assisted lumbar puncture surgery. IEEE Robot Autom Lett 9(1):343\u2013350","journal-title":"IEEE Robot Autom Lett"},{"issue":"1","key":"3617_CR35","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.jemermed.2013.08.056","volume":"46","author":"W Bonadio","year":"2014","unstructured":"Bonadio W (2014) Pediatric lumbar puncture and cerebrospinal fluid analysis. J Emerg Med 46(1):141\u2013150","journal-title":"J Emerg Med"},{"key":"3617_CR36","doi-asserted-by":"crossref","unstructured":"Campbell TP, Kelly KM (2024) Handbook of Emergency Neurology, Cambridge University Press pp 41\u201349","DOI":"10.1017\/9781316338513"},{"key":"3617_CR37","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1007\/s11701-024-02132-0","volume":"18","author":"H Li","year":"2024","unstructured":"Li H (2024) Active constrained motion control for a robot-assisted endoscope manipulator in pediatric minimal access surgery. J Robot Surg 18:378","journal-title":"J Robot Surg"}],"container-title":["Medical &amp; Biological Engineering &amp; Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-026-03617-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11517-026-03617-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11517-026-03617-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T08:23:16Z","timestamp":1786522996000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11517-026-03617-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,29]]},"references-count":37,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["3617"],"URL":"https:\/\/doi.org\/10.1007\/s11517-026-03617-w","relation":{},"ISSN":["0140-0118","1741-0444"],"issn-type":[{"value":"0140-0118","type":"print"},{"value":"1741-0444","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,29]]},"assertion":[{"value":"25 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study is approved by the Science and Technology Ethics Committee of Shanghai Jiao Tong University involving Humans with approval number: B20230334I.","order":1,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The author declare that he has no conflict of interest.","order":2,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}}]}}