{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:51:35Z","timestamp":1786981895639,"version":"build-2736575974"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T00:00:00Z","timestamp":1722816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T00:00:00Z","timestamp":1722816000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol med"],"DOI":"10.1007\/s11547-024-01864-1","type":"journal-article","created":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T03:02:19Z","timestamp":1722826939000},"page":"1454-1462","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Role of ultrasound-guided vacuum-assisted breast biopsy in the management of radiologic-pathologic discordance: a retrospective single-centre study"],"prefix":"10.1007","volume":"129","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2568-2768","authenticated-orcid":false,"given":"Giulia","family":"Vatteroni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulia","family":"Pinna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1502-0587","authenticated-orcid":false,"given":"Rubina Manuela","family":"Trimboli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9030-0071","authenticated-orcid":false,"given":"Riccardo","family":"Levi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabella","family":"Bolengo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Patrone","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daria","family":"Volpe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bethania","family":"Fernandes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4329-8121","authenticated-orcid":false,"given":"Daniela","family":"Bernardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,5]]},"reference":[{"key":"1864_CR1","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1016\/j.breast.2010.04.003","volume":"19","author":"JL Li","year":"2010","unstructured":"Li JL, Wang ZL, Su L, Liu XJ, Tang J (2010) Breast lesions with ultrasound imaging-histologic discordance at 16-gauge core needle biopsy: Can re-biopsy with 10-gauge vacuum-assisted system get definitive diagnosis? Breast 19:446\u2013449. https:\/\/doi.org\/10.1016\/j.breast.2010.04.003","journal-title":"Breast"},{"key":"1864_CR2","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s13244-019-0803-x","volume":"11","author":"U Bick","year":"2020","unstructured":"Bick U, Trimboli RM, Athanasiou A et al (2020) Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging. Insights Imaging 11:12. https:\/\/doi.org\/10.1186\/s13244-019-0803-x","journal-title":"Insights Imaging"},{"key":"1864_CR3","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.52097","author":"R Mohan","year":"2024","unstructured":"Mohan R, Selvakumar AS et al (2024) Correlation of histopathology and radiological findings among the diverse breast lesions in a Tertiary Care Centre. Cureus. https:\/\/doi.org\/10.7759\/cureus.52097","journal-title":"Cureus"},{"key":"1864_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.anndiagpath.2021.151864","volume":"57","author":"O Olayinka","year":"2022","unstructured":"Olayinka O, Kaur G, Agarwal R, Staradub V, Chacho MS, Vidhun R (2022) Impact of multidisciplinary radiologic-pathologic correlation conference for benign image-guided breast biopsies on discordance rates and patient outcomes in a community teaching hospital. Ann Diagn Pathol 57:151864. https:\/\/doi.org\/10.1016\/j.anndiagpath.2021.151864","journal-title":"Ann Diagn Pathol"},{"key":"1864_CR5","doi-asserted-by":"publisher","first-page":"232","DOI":"10.3348\/kjr.2011.12.2.232","volume":"12","author":"JH Youk","year":"2011","unstructured":"Youk JH, Kim E-K, Kim MJ et al (2011) Concordant or discordant? Imaging-pathology correlation in a sonography-guided core needle biopsy of a breast lesion. Korean J Radiol 12:232. https:\/\/doi.org\/10.3348\/kjr.2011.12.2.232","journal-title":"Korean J Radiol"},{"key":"1864_CR6","doi-asserted-by":"publisher","first-page":"107","DOI":"10.14366\/usg.17049","volume":"37","author":"VY Park","year":"2018","unstructured":"Park VY, Kim E-K, Moon HJ, Yoon JH, Kim MJ (2018) Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy. Ultrasonography 37:107\u201320. https:\/\/doi.org\/10.14366\/usg.17049","journal-title":"Ultrasonography"},{"key":"1864_CR7","unstructured":"American College of Radiology, D\u2019Orsi CJ, Sickles EA, Mendelson EB, Morris EA, eds (2013) ACR BI-RADS atlas: breast imaging reporting and data system\u202f; mammography, ultrasound, magnetic resonance imaging, follow-up and outcome monitoring, data dictionary. 5th edition. Reston, VA: ACR, American College of Radiology"},{"key":"1864_CR8","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1136\/jcp.2003.010983","volume":"57","author":"IO Ellis","year":"2004","unstructured":"Ellis IO, Humphreys S, Michell M, Pinder SE, Wells CA, Zakhour HD (2004) Best Practice No 179: Guidelines for breast needle core biopsy handling and reporting in breast screening assessment. J Clin Pathol 57:897\u2013902. https:\/\/doi.org\/10.1136\/jcp.2003.010983","journal-title":"J Clin Pathol"},{"key":"1864_CR9","doi-asserted-by":"publisher","first-page":"1078","DOI":"10.1177\/0284185114549224","volume":"56","author":"H Preibsch","year":"2015","unstructured":"Preibsch H, Baur A, Wietek BM et al (2015) Vacuum-assisted breast biopsy with 7-gauge, 8-gauge, 9-gauge, 10-gauge, and 11-gauge needles: how many specimens are necessary? Acta Radiol 56:1078\u20131084. https:\/\/doi.org\/10.1177\/0284185114549224","journal-title":"Acta Radiol"},{"key":"1864_CR10","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1148\/radiol.2323031224","volume":"232","author":"FM Lomoschitz","year":"2004","unstructured":"Lomoschitz FM, Helbich TH, Rudas M et al (2004) Stereotactic 11-gauge vacuum-assisted breast biopsy: influence of number of specimens on diagnostic accuracy. Radiology 232:897\u2013903. https:\/\/doi.org\/10.1148\/radiol.2323031224","journal-title":"Radiology"},{"key":"1864_CR11","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1007\/s00432-020-03481-7","volume":"147","author":"I J\u00f6rg","year":"2021","unstructured":"J\u00f6rg I, Wieler J, Elfgen C et al (2021) Discrepancies between radiological and histological findings in preoperative core needle (CNB) and vacuum-assisted (VAB) breast biopsies. J Cancer Res Clin Oncol 147:749\u2013754. https:\/\/doi.org\/10.1007\/s00432-020-03481-7","journal-title":"J Cancer Res Clin Oncol"},{"key":"1864_CR12","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1097\/JS9.0000000000000257","volume":"109","author":"Y Zhang","year":"2023","unstructured":"Zhang Y, Li J, Mo M et al (2023) The comparison of efficacy and safety evaluation of vacuum-assisted Elite 10-G system and the traditional BARD 14-G core needle in breast diagnosis: an open-label, parallel, randomized controlled trial. Int J Surg 109:1180\u20131187. https:\/\/doi.org\/10.1097\/JS9.0000000000000257","journal-title":"Int J Surg"},{"key":"1864_CR13","doi-asserted-by":"publisher","first-page":"2376","DOI":"10.1007\/s00330-007-0603-4","volume":"17","author":"MJ Kim","year":"2007","unstructured":"Kim MJ, Kim E-K, Lee JY et al (2007) Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings. Eur Radiol 17:2376\u20132383. https:\/\/doi.org\/10.1007\/s00330-007-0603-4","journal-title":"Eur Radiol"},{"key":"1864_CR14","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1007\/s00330-009-1632-y","volume":"20","author":"JH Youk","year":"2010","unstructured":"Youk JH, Kim E-K, Kim MJ, Kwak JY, Son EJ (2010) Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy. Eur Radiol 20:782\u2013789. https:\/\/doi.org\/10.1007\/s00330-009-1632-y","journal-title":"Eur Radiol"},{"key":"1864_CR15","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1111\/j.1524-4741.2011.01128.x","volume":"17","author":"ZL Wang","year":"2011","unstructured":"Wang ZL, Liu G, Li JL et al (2011) Breast lesions with imaging-histologic discordance during 16-gauge core needle biopsy system: would vacuum-assisted removal get significantly more definitive histologic diagnosis than vacuum-assisted biopsy?: Role of vacuum-assisted biopsy in the breast lesions. Breast J 17:456\u2013461. https:\/\/doi.org\/10.1111\/j.1524-4741.2011.01128.x","journal-title":"Breast J"},{"key":"1864_CR16","doi-asserted-by":"publisher","first-page":"1771","DOI":"10.1016\/j.ultrasmedbio.2011.07.006","volume":"37","author":"EJ Son","year":"2011","unstructured":"Son EJ, Kim E-K, Youk JH, Kim MJ, Kwak JY, Choi SH (2011) Imaging-histologic discordance after sonographically guided percutaneous breast biopsy: a prospective observational study. Ultrasound Med Biol 37:1771\u20131778. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2011.07.006","journal-title":"Ultrasound Med Biol"},{"key":"1864_CR17","doi-asserted-by":"publisher","first-page":"697","DOI":"10.3348\/kjr.2014.15.6.697","volume":"15","author":"Y-M Sohn","year":"2014","unstructured":"Sohn Y-M, Yoon JH, Kim E-K, Moon HJ, Kim MJ (2014) Percutaneous ultrasound-guided vacuum-assisted removal versus surgery for breast lesions showing imaging-histology discordance after ultrasound-guided core-needle biopsy. Korean J Radiol 15:697. https:\/\/doi.org\/10.3348\/kjr.2014.15.6.697","journal-title":"Korean J Radiol"},{"key":"1864_CR18","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1016\/j.amjsurg.2006.06.008","volume":"192","author":"DR Lannin","year":"2006","unstructured":"Lannin DR, Ponn T, Andrejeva L, Philpotts L (2006) Should all breast cancers be diagnosed by needle biopsy? Am J Surg 192:450\u2013454. https:\/\/doi.org\/10.1016\/j.amjsurg.2006.06.008","journal-title":"Am J Surg"},{"key":"1864_CR19","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1002\/jcu.20089","volume":"33","author":"P Crystal","year":"2005","unstructured":"Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33:47\u201352. https:\/\/doi.org\/10.1002\/jcu.20089","journal-title":"J Clin Ultrasound"},{"key":"1864_CR20","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1016\/j.ejrad.2012.03.003","volume":"82","author":"N Perrot","year":"2013","unstructured":"Perrot N, Jalaguier-Coudray A, Frey I, Thomassin-Naggara I, Chopier J (2013) US-guided core needle biopsy: false-negatives. How to reduce them? Eur J Radiol 82:424\u2013426. https:\/\/doi.org\/10.1016\/j.ejrad.2012.03.003","journal-title":"Eur J Radiol"},{"key":"1864_CR21","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.crad.2010.01.008","volume":"65","author":"EAM O\u2019Flynn","year":"2010","unstructured":"O\u2019Flynn EAM, Wilson ARM, Michell MJ (2010) Image-guided breast biopsy: state-of-the-art. Clin Radiol 65:259\u2013270. https:\/\/doi.org\/10.1016\/j.crad.2010.01.008","journal-title":"Clin Radiol"},{"key":"1864_CR22","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1016\/j.crad.2017.10.018","volume":"73","author":"WBG Sanderink","year":"2018","unstructured":"Sanderink WBG, Mann RM (2018) Advances in breast intervention: where are we now and where should we be? Clin Radiol 73:724\u2013734. https:\/\/doi.org\/10.1016\/j.crad.2017.10.018","journal-title":"Clin Radiol"},{"key":"1864_CR23","doi-asserted-by":"publisher","first-page":"102","DOI":"10.3348\/kjr.2005.6.2.102","volume":"6","author":"N Cho","year":"2005","unstructured":"Cho N, Moon WK, Cha JH et al (2005) Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods. Korean J Radiol 6:102. https:\/\/doi.org\/10.3348\/kjr.2005.6.2.102","journal-title":"Korean J Radiol"},{"key":"1864_CR24","doi-asserted-by":"publisher","first-page":"e349","DOI":"10.1259\/bjr\/30974918","volume":"85","author":"YJ Suh","year":"2012","unstructured":"Suh YJ, Kim MJ, Kim E-K et al (2012) Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy. Br J Radiol 85:e349\u2013e356. https:\/\/doi.org\/10.1259\/bjr\/30974918","journal-title":"Br J Radiol"},{"key":"1864_CR25","doi-asserted-by":"publisher","first-page":"2538","DOI":"10.1002\/1097-0142(20001215)89:12<2538::AID-CNCR4>3.0.CO;2-#","volume":"89","author":"L Liberman","year":"2000","unstructured":"Liberman L, Drotman M, Morris EA et al (2000) Imaging\u2013histologic discordance at percutaneous breast biopsy: an indicator of missed cancer. Cancer 89:2538\u20132546","journal-title":"Cancer"},{"key":"1864_CR26","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1148\/radiol.2392042127","volume":"239","author":"E Lazarus","year":"2006","unstructured":"Lazarus E, Mainiero MB, Schepps B, Koelliker SL, Livingston LS (2006) BI-RADS Lexicon for US and mammography: interobserver variability and positive predictive value. Radiology 239:385\u2013391. https:\/\/doi.org\/10.1148\/radiol.2392042127","journal-title":"Radiology"},{"key":"1864_CR27","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.2214\/ajr.184.4.01841260","volume":"184","author":"AS Hong","year":"2005","unstructured":"Hong AS, Rosen EL, Soo MS, Baker JA (2005) BI-RADS for sonography: positive and negative predictive values of sonographic features. Am J Roentgenol 184:1260\u20131265. https:\/\/doi.org\/10.2214\/ajr.184.4.01841260","journal-title":"Am J Roentgenol"},{"key":"1864_CR28","doi-asserted-by":"publisher","first-page":"649","DOI":"10.7863\/jum.2006.25.5.649","volume":"25","author":"M Costantini","year":"2006","unstructured":"Costantini M, Belli P, Lombardi R, Franceschini G, Mul\u00e8 A, Bonomo L (2006) Characterization of solid breast masses: use of the sonographic breast imaging reporting and data system lexicon. J Ultrasound Med 25:649\u2013659. https:\/\/doi.org\/10.7863\/jum.2006.25.5.649","journal-title":"J Ultrasound Med"},{"key":"1864_CR29","doi-asserted-by":"publisher","first-page":"185","DOI":"10.5114\/pjr.2019.85302","volume":"84","author":"K Kozie\u0142ek","year":"2019","unstructured":"Kozie\u0142ek K, Stranz-Walczak N, Gajdzis P, Karmelita-Katulska K (2019) Evaluation of the positive predictive value (PPV3) of ACR BI-RADS category 4 and 5 based on the outcomes of Invasive Diagnostic Office in an outpatient clinic. Pol J Radiol 84:185\u2013189. https:\/\/doi.org\/10.5114\/pjr.2019.85302","journal-title":"Pol J Radiol"},{"key":"1864_CR30","doi-asserted-by":"publisher","first-page":"259","DOI":"10.14366\/usg.14020","volume":"33","author":"SH Lee","year":"2014","unstructured":"Lee SH, Kim E-K, Kim MJ, Moon HJ, Yoon JH (2014) Vacuum-assisted breast biopsy under sonographic guidance: analysis of 10 years of experience. Ultrasonography 33:259\u201366. https:\/\/doi.org\/10.14366\/usg.14020","journal-title":"Ultrasonography"}],"container-title":["La radiologia medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-024-01864-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11547-024-01864-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-024-01864-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T11:16:06Z","timestamp":1728990966000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11547-024-01864-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,5]]},"references-count":30,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2024,10]]}},"alternative-id":["1864"],"URL":"https:\/\/doi.org\/10.1007\/s11547-024-01864-1","relation":{},"ISSN":["1826-6983"],"issn-type":[{"value":"1826-6983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,5]]},"assertion":[{"value":"4 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations\u00a0"}},{"value":"The authors have no relevant financial or non-financial interests to disclose. Dr. RM Trimboli received travel support from BD Italia.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The retrospective study was granted exemption by the institutional ethics committee (EC of the IRCCS Istituto Clinico Humanitas, Rozzano, Milan) and conducted in accordance with the principles of the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent to participate in the study was waived due to the retrospective study design and informed consent to the biopsies was obtained prospectively from all women included in the analysis.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors affirm that corresponding women provided informed consent for publication of the images in Figs.\u00a0\n                      \n                      and\n                      \n                      .","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}