{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T07:55:20Z","timestamp":1782287720225,"version":"3.54.5"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol med"],"DOI":"10.1007\/s11547-025-02033-8","type":"journal-article","created":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T01:29:14Z","timestamp":1750382954000},"page":"1339-1351","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Artificial intelligence-based tumor size measurement on mammography: agreement with pathology and comparison with human readers\u2019 assessments across multiple imaging modalities"],"prefix":"10.1007","volume":"130","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8225-3690","authenticated-orcid":false,"given":"Mi-ri","family":"Kwon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4478-9720","authenticated-orcid":false,"given":"Sung Hun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2479-6950","authenticated-orcid":false,"given":"Ga Eun","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4718-1788","authenticated-orcid":false,"given":"Han Song","family":"Mun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5991-6035","authenticated-orcid":false,"given":"Bong Joo","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5171-2962","authenticated-orcid":false,"given":"Yun Tae","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3518-3332","authenticated-orcid":false,"given":"Inyoung","family":"Youn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,20]]},"reference":[{"issue":"19","key":"2033_CR1","doi-asserted-by":"publisher","first-page":"3673","DOI":"10.1002\/cncr.30842","volume":"123","author":"EK Arleo","year":"2017","unstructured":"Arleo EK, Hendrick RE, Helvie MA, Sickles EA (2017) Comparison of recommendations for screening mammography using CISNET models. Cancer 123(19):3673\u20133680. https:\/\/doi.org\/10.1002\/cncr.30842","journal-title":"Cancer"},{"issue":"1","key":"2033_CR2","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s13058-019-1203-3","volume":"21","author":"M von Euler-Chelpin","year":"2019","unstructured":"von Euler-Chelpin M, Lillholm M, Vejborg I, Nielsen M, Lynge E (2019) Sensitivity of screening mammography by density and texture: a cohort study from a population-based screening program in Denmark. Breast Cancer Res 21(1):111. https:\/\/doi.org\/10.1186\/s13058-019-1203-3","journal-title":"Breast Cancer Res"},{"issue":"2","key":"2033_CR3","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1148\/radiol.2019190951","volume":"294","author":"S Hong","year":"2020","unstructured":"Hong S, Song SY, Park B et al (2020) Effect of digital mammography for breast cancer screening: a comparative study of more than 8 million Korean women. Radiology 294(2):247\u2013255. https:\/\/doi.org\/10.1148\/radiol.2019190951","journal-title":"Radiology"},{"issue":"3","key":"2033_CR4","doi-asserted-by":"publisher","first-page":"e138","DOI":"10.1016\/S2589-7500(20)30003-0","volume":"2","author":"H-E Kim","year":"2020","unstructured":"Kim H-E, Kim HH, Han B-K et al (2020) Changes in cancer detection and false-positive recall in mammography using artificial intelligence: a retrospective multireader study. Lancet Digital Health 2(3):e138\u2013e148. https:\/\/doi.org\/10.1016\/S2589-7500(20)30003-0","journal-title":"Lancet Digital Health"},{"issue":"3","key":"2033_CR5","doi-asserted-by":"publisher","first-page":"e200265","DOI":"10.1001\/jamanetworkopen.2020.0265","volume":"3","author":"T Schaffter","year":"2020","unstructured":"Schaffter T, Buist DSM, Lee CI et al (2020) Evaluation of combined artificial intelligence and radiologist assessment to interpret screening mammograms. JAMA Netw Open 3(3):e200265\u2013e200265. https:\/\/doi.org\/10.1001\/jamanetworkopen.2020.0265","journal-title":"JAMA Netw Open"},{"issue":"2","key":"2033_CR6","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1148\/radiol.2018181371","volume":"290","author":"A Rodr\u00edguez-Ruiz","year":"2019","unstructured":"Rodr\u00edguez-Ruiz A, Krupinski E, Mordang J-J et al (2019) Detection of breast cancer with mammography: effect of an artificial intelligence support system. Radiology 290(2):305\u2013314. https:\/\/doi.org\/10.1148\/radiol.2018181371","journal-title":"Radiology"},{"issue":"6","key":"2033_CR7","doi-asserted-by":"publisher","first-page":"e190208","DOI":"10.1148\/ryai.2020190208","volume":"2","author":"S Pacil\u00e8","year":"2020","unstructured":"Pacil\u00e8 S, Lopez J, Chone P, Bertinotti T, Grouin JM, Fillard P (2020) Improving breast cancer detection accuracy of mammography with the concurrent use of an artificial intelligence tool. Radiol: Artif Intel 2(6):e190208. https:\/\/doi.org\/10.1148\/ryai.2020190208","journal-title":"Radiol: Artif Intel"},{"key":"2033_CR8","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.jacr.2021.11.008","volume":"19","author":"AW Anderson","year":"2022","unstructured":"Anderson AW, Marinovich ML, Houssami N et al (2022) Independent external validation of artificial intelligence algorithms for automated interpretation of screening mammography: a systematic review. J Am Coll Radiol 19:259\u2013273. https:\/\/doi.org\/10.1016\/j.jacr.2021.11.008","journal-title":"J Am Coll Radiol"},{"issue":"5","key":"2033_CR9","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222639","volume":"307","author":"JH Yoon","year":"2023","unstructured":"Yoon JH, Strand F, Baltzer PAT et al (2023) Standalone AI for breast cancer detection at screening digital mammography and digital breast tomosynthesis: a systematic review and meta-analysis. Radiology 307(5):e222639. https:\/\/doi.org\/10.1148\/radiol.222639","journal-title":"Radiology"},{"issue":"1","key":"2033_CR10","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3348\/jksr.2020.0205","volume":"82","author":"KHLS Kim","year":"2021","unstructured":"Kim KHLS (2021) Applications of artificial intelligence in mammography from a development and validation perspective. J Korean Soc Radiol. 82(1):12\u201328. https:\/\/doi.org\/10.3348\/jksr.2020.0205","journal-title":"J Korean Soc Radiol."},{"issue":"4","key":"2033_CR11","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1002\/cncr.10742","volume":"95","author":"JS Michaelson","year":"2002","unstructured":"Michaelson JS, Silverstein M, Wyatt J et al (2002) Predicting the survival of patients with breast carcinoma using tumor size. Cancer 95(4):713\u2013723. https:\/\/doi.org\/10.1002\/cncr.10742","journal-title":"Cancer"},{"issue":"3","key":"2033_CR12","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s10549-018-4796-9","volume":"170","author":"V Sopik","year":"2018","unstructured":"Sopik V, Narod SA (2018) The relationship between tumour size, nodal status and distant metastases: on the origins of breast cancer. Breast Cancer Res Treat 170(3):647\u2013656. https:\/\/doi.org\/10.1007\/s10549-018-4796-9","journal-title":"Breast Cancer Res Treat"},{"issue":"4","key":"2033_CR13","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1177\/000313481207800435","volume":"78","author":"SI Ramirez","year":"2012","unstructured":"Ramirez SI, Scholle M, Buckmaster J, Paley RH, Kowdley GC (2012) Breast cancer tumor size assessment with mammography, ultrasonography, and magnetic resonance imaging at a community based multidisciplinary breast center. Am Surg 78(4):440\u2013446","journal-title":"Am Surg"},{"key":"2033_CR14","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1186\/1471-2407-13-328","volume":"13","author":"IV Gruber","year":"2013","unstructured":"Gruber IV, Rueckert M, Kagan KO et al (2013) Measurement of tumour size with mammography, sonography and magnetic resonance imaging as compared to histological tumour size in primary breast cancer. BMC Cancer 13:328. https:\/\/doi.org\/10.1186\/1471-2407-13-328","journal-title":"BMC Cancer"},{"issue":"3","key":"2033_CR15","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1148\/radiology.197.3.7480749","volume":"197","author":"C Boetes","year":"1995","unstructured":"Boetes C, Mus RD, Holland R et al (1995) Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent. Radiology 197(3):743\u2013747. https:\/\/doi.org\/10.1148\/radiology.197.3.7480749","journal-title":"Radiology"},{"issue":"10","key":"2033_CR16","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1177\/000313480907501024","volume":"75","author":"N Wasif","year":"2009","unstructured":"Wasif N, Garreau J, Terando A, Kirsch D, Mund DF, Giuliano AE (2009) MRI versus ultrasonography and mammography for preoperative assessment of breast cancer. Am Surg 75(10):970\u2013975","journal-title":"Am Surg"},{"issue":"2","key":"2033_CR17","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1148\/radiol.2018172868","volume":"289","author":"S-Y Kim","year":"2018","unstructured":"Kim S-Y, Cho N, Park I-A et al (2018) Dynamic contrast-enhanced breast mri for evaluating residual tumor size after neoadjuvant chemotherapy. Radiology 289(2):327\u2013334. https:\/\/doi.org\/10.1148\/radiol.2018172868","journal-title":"Radiology"},{"issue":"3","key":"2033_CR18","doi-asserted-by":"publisher","first-page":"253","DOI":"10.15386\/mpr-1476","volume":"93","author":"G Sezg\u0131n","year":"2020","unstructured":"Sezg\u0131n G, Apayd\u0131n M, Et\u0131t D, Atahan MK (2020) Tumor size estimation of the breast cancer molecular subtypes using imaging techniques. Med Pharm Rep 93(3):253\u2013259. https:\/\/doi.org\/10.15386\/mpr-1476","journal-title":"Med Pharm Rep"},{"issue":"10","key":"2033_CR19","doi-asserted-by":"publisher","first-page":"2367","DOI":"10.3390\/cancers14102367","volume":"14","author":"G Schultek","year":"2022","unstructured":"Schultek G, Gerber B, Reimer T et al (2022) Radiological underestimation of tumor size as a relevant risk factor for positive margin rate in breast-conserving therapy of pure ductal carcinoma in situ (DCIS). Cancers 14(10):2367","journal-title":"Cancers"},{"issue":"4","key":"2033_CR20","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/S0002-9610(01)00726-7","volume":"182","author":"TJ Hieken","year":"2001","unstructured":"Hieken TJ, Harrison J, Herreros J, Velasco JM (2001) Correlating sonography, mammography, and pathology in the assessment of breast cancer size. Am J Surg 182(4):351\u2013354. https:\/\/doi.org\/10.1016\/S0002-9610(01)00726-7","journal-title":"Am J Surg"},{"issue":"8","key":"2033_CR21","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1016\/s1470-2045(23)00298-x","volume":"24","author":"K L\u00e5ng","year":"2023","unstructured":"L\u00e5ng K, Josefsson V, Larsson AM et al (2023) Artificial intelligence-supported screen reading versus standard double reading in the mammography screening with artificial intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study. Lancet Oncol 24(8):936\u2013944. https:\/\/doi.org\/10.1016\/s1470-2045(23)00298-x","journal-title":"Lancet Oncol"},{"issue":"10","key":"2033_CR22","doi-asserted-by":"publisher","first-page":"e703","DOI":"10.1016\/S2589-7500(23)00153-X","volume":"5","author":"K Dembrower","year":"2023","unstructured":"Dembrower K, Crippa A, Col\u00f3n E, Eklund M, Strand F (2023) Artificial intelligence for breast cancer detection in screening mammography in Sweden: a prospective, population-based, paired-reader, non-inferiority study. Lancet Digital Health 5(10):e703\u2013e711. https:\/\/doi.org\/10.1016\/S2589-7500(23)00153-X","journal-title":"Lancet Digital Health"},{"key":"2033_CR23","doi-asserted-by":"publisher","DOI":"10.1038\/s41591-024-03408-6","author":"N Eisemann","year":"2025","unstructured":"Eisemann N, Bunk S, Mukama T et al (2025) Nationwide real-world implementation of AI for cancer detection in population-based mammography screening. Nat Med. https:\/\/doi.org\/10.1038\/s41591-024-03408-6","journal-title":"Nat Med"},{"issue":"4","key":"2033_CR24","doi-asserted-by":"publisher","first-page":"343","DOI":"10.3348\/kjr.2023.0907","volume":"25","author":"SE Lee","year":"2024","unstructured":"Lee SE, Hong H, Kim EK (2024) Positive predictive values of abnormality scores from a commercial artificial intelligence-based computer-aided diagnosis for mammography. Korean J Radiol 25(4):343\u2013350. https:\/\/doi.org\/10.3348\/kjr.2023.0907","journal-title":"Korean J Radiol"},{"issue":"11","key":"2033_CR25","doi-asserted-by":"publisher","first-page":"7400","DOI":"10.1007\/s00330-022-08718-2","volume":"32","author":"SE Lee","year":"2022","unstructured":"Lee SE, Han K, Yoon JH, Youk JH, Kim EK (2022) Depiction of breast cancers on digital mammograms by artificial intelligence-based computer-assisted diagnosis according to cancer characteristics. Eur Radiol 32(11):7400\u20137408. https:\/\/doi.org\/10.1007\/s00330-022-08718-2","journal-title":"Eur Radiol"},{"issue":"6","key":"2033_CR26","doi-asserted-by":"publisher","first-page":"2239","DOI":"10.1016\/j.acra.2023.12.006","volume":"31","author":"H Yoen","year":"2024","unstructured":"Yoen H, Jang MJ, Yi A, Moon WK, Chang JM (2024) Artificial intelligence for breast cancer detection on mammography: factors related to cancer detection. Acad Radiol 31(6):2239\u20132247. https:\/\/doi.org\/10.1016\/j.acra.2023.12.006","journal-title":"Acad Radiol"},{"issue":"1","key":"2033_CR27","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1038\/s43856-022-00199-0","volume":"2","author":"D-M Koh","year":"2022","unstructured":"Koh D-M, Papanikolaou N, Bick U et al (2022) Artificial intelligence and machine learning in cancer imaging. Commun Med 2(1):133. https:\/\/doi.org\/10.1038\/s43856-022-00199-0","journal-title":"Commun Med"},{"issue":"11","key":"2033_CR28","doi-asserted-by":"publisher","first-page":"e581","DOI":"10.1016\/S1470-2045(24)00316-4","volume":"25","author":"JE Villanueva-Meyer","year":"2024","unstructured":"Villanueva-Meyer JE, Bakas S, Tiwari P et al (2024) Artificial intelligence for response assessment in neuro oncology (AI-RANO), part 1: review of current advancements. Lancet Oncol 25(11):e581\u2013e588. https:\/\/doi.org\/10.1016\/S1470-2045(24)00316-4","journal-title":"Lancet Oncol"},{"issue":"21","key":"2033_CR29","doi-asserted-by":"publisher","first-page":"5236","DOI":"10.3390\/cancers15215236","volume":"15","author":"Z Gandhi","year":"2023","unstructured":"Gandhi Z, Gurram P, Amgai B et al (2023) Artificial intelligence and lung cancer: impact on improving patient outcomes. Cancers 15(21):5236","journal-title":"Cancers"},{"issue":"4","key":"2033_CR30","doi-asserted-by":"publisher","first-page":"2301","DOI":"10.1007\/s00330-021-08308-8","volume":"32","author":"SH Heywang-K\u00f6brunner","year":"2022","unstructured":"Heywang-K\u00f6brunner SH, J\u00e4nsch A, Hacker A, Weinand S, Vogelmann T (2022) Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis. Eur Radiol 32(4):2301\u20132312. https:\/\/doi.org\/10.1007\/s00330-021-08308-8","journal-title":"Eur Radiol"},{"issue":"6s","key":"2033_CR31","doi-asserted-by":"publisher","first-page":"S126","DOI":"10.1016\/j.jacr.2024.02.019","volume":"21","author":"BL Niell","year":"2024","unstructured":"Niell BL, Jochelson MS, Amir T et al (2024) ACR appropriateness criteria\u00ae female breast cancer screening: 2023 update. J Am Coll Radiol 21(6s):S126-s143. https:\/\/doi.org\/10.1016\/j.jacr.2024.02.019","journal-title":"J Am Coll Radiol"}],"updated-by":[{"DOI":"10.1007\/s11547-025-02059-y","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000}}],"container-title":["La radiologia medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-025-02033-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11547-025-02033-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-025-02033-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,24]],"date-time":"2025-09-24T12:03:32Z","timestamp":1758715412000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11547-025-02033-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,20]]},"references-count":31,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2025,9]]}},"alternative-id":["2033"],"URL":"https:\/\/doi.org\/10.1007\/s11547-025-02033-8","relation":{},"ISSN":["1826-6983"],"issn-type":[{"value":"1826-6983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,20]]},"assertion":[{"value":"18 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1007\/s11547-025-02059-y","URL":"https:\/\/doi.org\/10.1007\/s11547-025-02059-y","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"This retrospective study was approved by the Institutional Review Board of the Ethics Committee of Seoul St. Mary\u2019s Hospital.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The requirement for written informed consent was waived because of the retrospective nature of the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}]}}