{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T09:03:13Z","timestamp":1791450193971,"version":"4.3.3"},"reference-count":151,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T00:00:00Z","timestamp":1758844800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003196","name":"Ministero della Salute","doi-asserted-by":"publisher","award":["PNC-E3-2022-23683266"],"award-info":[{"award-number":["PNC-E3-2022-23683266"]}],"id":[{"id":"10.13039\/501100003196","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004913","name":"Universit\u00e0 degli Studi di Palermo","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004913","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Ultra-low-field magnetic resonance imaging (ULF-MRI), operating below 0.2 Tesla, is gaining renewed interest as a re-emerging diagnostic modality in a field dominated by high- and ultra-high-field systems. Recent advances in magnet design, RF coils, pulse sequences, and AI-based reconstruction have significantly enhanced image quality, mitigating traditional limitations such as low signal- and contrast-to-noise ratio and reduced spatial resolution. ULF-MRI offers distinct advantages: reduced susceptibility artifacts, safer imaging in patients with metallic implants, low power consumption, and true portability for point-of-care use. This narrative review synthesizes the physical foundations, technological advances, and emerging clinical applications of ULF-MRI. A focused literature search across PubMed, Scopus, IEEE Xplore, and Google Scholar was conducted up to August 11, 2025, using combined keywords targeting hardware, software, and clinical domains. Inclusion emphasized scientific rigor and thematic relevance. A comparative analysis with other imaging modalities highlights the specific niche ULF-MRI occupies within the broader diagnostic landscape. Future directions and challenges for clinical translation are explored. In a world increasingly polarized between the push for ultra-high-field excellence and the need for accessible imaging, ULF-MRI embodies a modern \u201c\n                    <jats:italic>David versus Goliath<\/jats:italic>\n                    \u201d theme, offering a sustainable, democratizing force capable of expanding MRI access to anyone, anywhere.\n                  <\/jats:p>","DOI":"10.1007\/s11547-025-02091-y","type":"journal-article","created":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T14:34:16Z","timestamp":1758897256000},"page":"2012-2029","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Ultra-low-field MRI: a David versus Goliath challenge in modern imaging"],"prefix":"10.1007","volume":"130","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4088-2020","authenticated-orcid":false,"given":"Cesare","family":"Gagliardo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3707-018X","authenticated-orcid":false,"given":"Paola","family":"Feraco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eleonora","family":"Contrino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Costanza","family":"D\u2019Angelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Geraci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2465-1185","authenticated-orcid":false,"given":"Giuseppe","family":"Salvaggio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Gagliardo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludovico","family":"La Grutta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Massimo","family":"Midiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0091-3243","authenticated-orcid":false,"given":"Maurizio","family":"Marrale","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,26]]},"reference":[{"issue":"3","key":"2091_CR1","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1148\/radiol.2019182742","volume":"292","author":"MN Hoff","year":"2019","unstructured":"Hoff MN, McKinney A, Shellock FG et al (2019) Safety considerations of 7-T MRI in clinical practice. Radiology 292(3):509\u2013518. https:\/\/doi.org\/10.1148\/radiol.2019182742","journal-title":"Radiology"},{"issue":"2","key":"2091_CR2","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1148\/radiol.2020192291","volume":"296","author":"A Boutet","year":"2020","unstructured":"Boutet A, Chow CT, Narang K et al (2020) Improving safety of MRI in patients with deep brain stimulation devices. Radiology 296(2):250\u2013262. https:\/\/doi.org\/10.1148\/radiol.2020192291","journal-title":"Radiology"},{"issue":"1","key":"2091_CR3","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1002\/jmri.25761","volume":"47","author":"LP Panych","year":"2018","unstructured":"Panych LP, Madore B (2018) The physics of MRI safety. J Magn Reson Imaging 47(1):28\u201343. https:\/\/doi.org\/10.1002\/jmri.25761","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2091_CR4","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/j.ocl.2018.05.010","volume":"49","author":"ZA Mosher","year":"2018","unstructured":"Mosher ZA, Sawyer JR, Kelly DM (2018) MRI safety with orthopedic implants. Orthop Clin North Am 49(4):455\u2013463. https:\/\/doi.org\/10.1016\/j.ocl.2018.05.010","journal-title":"Orthop Clin North Am"},{"issue":"7","key":"2091_CR5","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1007\/s00247-023-05651-4","volume":"53","author":"LH Betz","year":"2023","unstructured":"Betz LH, Dillman JR, Jones BV, Tkach JA (2023) MRI safety screening of children with implants: updates and challenges. Pediatr Radiol 53(7):1454\u20131468. https:\/\/doi.org\/10.1007\/s00247-023-05651-4","journal-title":"Pediatr Radiol"},{"issue":"4","key":"2091_CR6","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1002\/jmri.28994","volume":"59","author":"YV Chaban","year":"2024","unstructured":"Chaban YV, Vosshenrich J, McKee H et al (2024) Environmental sustainability and MRI: challenges, opportunities, and a call for action. J Magn Reson Imaging 59(4):1149\u20131167. https:\/\/doi.org\/10.1002\/jmri.28994","journal-title":"J Magn Reson Imaging"},{"key":"2091_CR7","doi-asserted-by":"publisher","DOI":"10.1177\/08465371251327143","author":"DA Leswick","year":"2025","unstructured":"Leswick DA, Kulanthaivelu R, Jamil H et al (2025) Enhancing environmental sustainability in diagnostic radiology: focus on CT, MRI, and nuclear medicine. Can Assoc Radiol J J Assoc Can Radiol. https:\/\/doi.org\/10.1177\/08465371251327143","journal-title":"Can Assoc Radiol J J Assoc Can Radiol"},{"issue":"2","key":"2091_CR8","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.232030","volume":"310","author":"FX Doo","year":"2024","unstructured":"Doo FX, Vosshenrich J, Cook TS et al (2024) Environmental sustainability and AI in radiology: a double-edged sword. Radiology 310(2):e232030. https:\/\/doi.org\/10.1148\/radiol.232030","journal-title":"Radiology"},{"issue":"1","key":"2091_CR9","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s41747-024-00424-6","volume":"8","author":"A Roletto","year":"2024","unstructured":"Roletto A, Zanardo M, Bonfitto GR, Catania D, Sardanelli F, Zanoni S (2024) The environmental impact of energy consumption and carbon emissions in radiology departments: a systematic review. Eur Radiol Exp 8(1):35. https:\/\/doi.org\/10.1186\/s41747-024-00424-6","journal-title":"Eur Radiol Exp"},{"key":"2091_CR10","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.radi.2024.08.002","volume":"30","author":"SS Ghotra","year":"2024","unstructured":"Ghotra SS, Champendal M, Flaction L, Ribeiro RT, S\u00e1 Dos Reis C (2024) Approaches to reduce medical imaging departments\u2019 environmental impact: a scoping review. Radiogr Lond Engl 30:108\u2013116. https:\/\/doi.org\/10.1016\/j.radi.2024.08.002","journal-title":"Radiogr Lond Engl"},{"issue":"2","key":"2091_CR11","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1097\/RCT.0000000000001700","volume":"49","author":"AM Hernandez","year":"2025","unstructured":"Hernandez AM, Chen AF, Ghatpande O et al (2025) Reducing the energy consumption of magnetic resonance imaging and computed tomography scanners: integrating ecodesign and sustainable operations. J Comput Assist Tomogr 49(2):191\u2013202. https:\/\/doi.org\/10.1097\/RCT.0000000000001700","journal-title":"J Comput Assist Tomogr"},{"key":"2091_CR12","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4921","author":"M Manso Jimeno","year":"2023","unstructured":"Manso Jimeno M, Vaughan JT, Geethanath S (2023) Superconducting magnet designs and MRI accessibility: a review. NMR Biomed. https:\/\/doi.org\/10.1002\/nbm.4921","journal-title":"NMR Biomed"},{"issue":"3","key":"2091_CR13","doi-asserted-by":"publisher","first-page":"92","DOI":"10.22575\/interventionalradiology.2023-0033","volume":"9","author":"M Uka","year":"2024","unstructured":"Uka M, Matsui Y, Iguchi T et al (2024) Magnetic resonance imaging guidance for percutaneous needle intervention. Intervent Radiol 9(3):92\u201398. https:\/\/doi.org\/10.22575\/interventionalradiology.2023-0033","journal-title":"Intervent Radiol"},{"key":"2091_CR14","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.jad.2025.04.028","volume":"381","author":"I Terao","year":"2025","unstructured":"Terao I, Kodama W (2025) Effectiveness of personalized repetitive transcranial magnetic stimulation for major depressive disorder: a systematic review and meta-analysis of randomized active-controlled trials. J Affect Disord 381:275\u2013280. https:\/\/doi.org\/10.1016\/j.jad.2025.04.028","journal-title":"J Affect Disord"},{"issue":"10","key":"2091_CR15","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.71613","volume":"16","author":"T Musaddaq","year":"2024","unstructured":"Musaddaq T, Musaddaq B (2024) Recent Advances in image-guided tissue sampling. Cureus 16(10):e71613. https:\/\/doi.org\/10.7759\/cureus.71613","journal-title":"Cureus"},{"issue":"5","key":"2091_CR16","doi-asserted-by":"publisher","DOI":"10.3171\/2024.8.FOCUS24444","volume":"57","author":"M Aubignat","year":"2024","unstructured":"Aubignat M, Tir M, Ouendo M, Boussida S, Constans JM, Lefranc M (2024) Stereotactic robot-assisted MRI-guided laser interstitial thermal therapy thalamotomy for medically intractable Holmes tremor: a pilot study and literature review. Neurosurg Focus 57(5):E9. https:\/\/doi.org\/10.3171\/2024.8.FOCUS24444","journal-title":"Neurosurg Focus"},{"issue":"1","key":"2091_CR17","doi-asserted-by":"publisher","first-page":"150","DOI":"10.2214\/AJR.14.13632","volume":"205","author":"P Ghanouni","year":"2015","unstructured":"Ghanouni P, Pauly KB, Elias WJ et al (2015) Transcranial MRI-guided focused ultrasound: a review of the technologic and neurologic applications. AJR Am J Roentgenol 205(1):150\u2013159. https:\/\/doi.org\/10.2214\/AJR.14.13632","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2091_CR18","doi-asserted-by":"publisher","DOI":"10.1148\/rycan.230074","volume":"6","author":"A De Maio","year":"2024","unstructured":"De Maio A, Alfieri G, Mattone M, Ghanouni P, Napoli A (2024) High-intensity focused ultrasound surgery for tumor ablation: a review of current applications. Radiol Imaging Cancer 6(1):e230074. https:\/\/doi.org\/10.1148\/rycan.230074","journal-title":"Radiol Imaging Cancer"},{"key":"2091_CR19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jlb.2024.100277","volume":"6","author":"M Izhar","year":"2024","unstructured":"Izhar M, Thakur A, Park DJ, Chang SD (2024) Ultrasound mediated blood-brain barrier opening increases brain tumor biomarkers: a review of preclinical and clinical trials. J Liquid Biopsy 6:100277. https:\/\/doi.org\/10.1016\/j.jlb.2024.100277","journal-title":"J Liquid Biopsy"},{"issue":"6","key":"2091_CR20","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1038\/s41571-024-00891-1","volume":"21","author":"E Hoffmann","year":"2024","unstructured":"Hoffmann E, Masthoff M, Kunz WG et al (2024) Multiparametric MRI for characterization of the tumour microenvironment. Nat Rev Clin Oncol 21(6):428\u2013448. https:\/\/doi.org\/10.1038\/s41571-024-00891-1","journal-title":"Nat Rev Clin Oncol"},{"issue":"9","key":"2091_CR21","doi-asserted-by":"publisher","first-page":"4147","DOI":"10.7150\/thno.108705","volume":"15","author":"L Zhang","year":"2025","unstructured":"Zhang L, Roy S, Guo B (2025) The role of manganese-based MRI contrast agents for cancer theranostics: Where do we stand in 2025? Theranostics 15(9):4147\u20134174. https:\/\/doi.org\/10.7150\/thno.108705","journal-title":"Theranostics"},{"issue":"1","key":"2091_CR22","doi-asserted-by":"publisher","first-page":"4006","DOI":"10.1038\/ncomms5006","volume":"5","author":"ER Velazquez","year":"2014","unstructured":"Velazquez ER, Leijenaar RTH, Parmar C et al (2014) Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nat Commun 5(1):4006. https:\/\/doi.org\/10.1038\/ncomms5006","journal-title":"Nat Commun"},{"issue":"12","key":"2091_CR23","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1038\/nrclinonc.2017.141","volume":"14","author":"P Lambin","year":"2017","unstructured":"Lambin P, Leijenaar RTH, Deist TM et al (2017) Radiomics: the bridge between medical imaging and personalized medicine. Nat Rev Clin Oncol 14(12):749\u2013762. https:\/\/doi.org\/10.1038\/nrclinonc.2017.141","journal-title":"Nat Rev Clin Oncol"},{"issue":"8","key":"2091_CR24","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1038\/s41571-022-00652-y","volume":"19","author":"L Bodei","year":"2022","unstructured":"Bodei L, Herrmann K, Sch\u00f6der H, Scott AM, Lewis JS (2022) Radiotheranostics in oncology: current challenges and emerging opportunities. Nat Rev Clin Oncol 19(8):534\u2013550. https:\/\/doi.org\/10.1038\/s41571-022-00652-y","journal-title":"Nat Rev Clin Oncol"},{"issue":"3","key":"2091_CR25","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1109\/TASC.2010.2089402","volume":"21","author":"AN Matlashov","year":"2011","unstructured":"Matlashov AN, Schultz LJ, Espy MA et al (2011) SQUIDs vs. induction coils for ultra-low field nuclear magnetic resonance: experimental and simulation comparison. IEEE Trans Appl Supercond 21(3):465\u2013468. https:\/\/doi.org\/10.1109\/TASC.2010.2089402","journal-title":"IEEE Trans Appl Supercond"},{"issue":"1","key":"2091_CR26","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.jmr.2011.06.022","volume":"212","author":"JO Nieminen","year":"2011","unstructured":"Nieminen JO, Vesanen PT, Zevenhoven KCJ et al (2011) Avoiding eddy-current problems in ultra-low-field MRI with self-shielded polarizing coils. J Magn Reson San Diego Calif 212(1):154\u2013160. https:\/\/doi.org\/10.1016\/j.jmr.2011.06.022","journal-title":"J Magn Reson San Diego Calif"},{"issue":"6","key":"2091_CR27","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/0730-725x(89)90527-4","volume":"7","author":"LO Wahlund","year":"1989","unstructured":"Wahlund LO, Boethius J, Kindstrand E, Marions O, S\u00e4\u00e4f J, Wetterberg L (1989) A new method for characterization of low grade gliomas using ultra low field magnetic resonance imaging. Magn Reson Imaging 7(6):599\u2013603. https:\/\/doi.org\/10.1016\/0730-725x(89)90527-4","journal-title":"Magn Reson Imaging"},{"issue":"2","key":"2091_CR28","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1109\/TBME.2024.3466929","volume":"72","author":"H Wang","year":"2025","unstructured":"Wang H, Feng W, Ren X et al (2025) Acquisition acceleration of ultra-low field MRI with parallel imaging and compressed sensing in microtesla fields. IEEE Trans Biomed Eng 72(2):655\u2013663. https:\/\/doi.org\/10.1109\/TBME.2024.3466929","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"2091_CR29","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1016\/j.mri.2014.01.012","volume":"32","author":"PT Vesanen","year":"2014","unstructured":"Vesanen PT, Nieminen JO, Zevenhoven KCJ, Hsu YC, Ilmoniemi RJ (2014) Current-density imaging using ultra-low-field MRI with zero-field encoding. Magn Reson Imaging 32(6):766\u2013770. https:\/\/doi.org\/10.1016\/j.mri.2014.01.012","journal-title":"Magn Reson Imaging"},{"key":"2091_CR30","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.mri.2019.03.010","volume":"60","author":"P H\u00f6mmen","year":"2019","unstructured":"H\u00f6mmen P, Storm JH, H\u00f6fner N, K\u00f6rber R (2019) Demonstration of full tensor current density imaging using ultra-low field MRI. Magn Reson Imaging 60:137\u2013144. https:\/\/doi.org\/10.1016\/j.mri.2019.03.010","journal-title":"Magn Reson Imaging"},{"key":"2091_CR31","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1109\/EMBC.2012.6346125","volume":"2012","author":"J Dabek","year":"2012","unstructured":"Dabek J, Zevenhoven KCJ, Nieminen JO, Vesanen PT, Sepponen R, Ilmoniemi RJ (2012) Gradient-excitation encoding combined with frequency and phase encodings for three-dimensional ultra-low-field MRI. Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Int Conf 2012:1093\u20131097. https:\/\/doi.org\/10.1109\/EMBC.2012.6346125","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Int Conf"},{"issue":"24","key":"2091_CR32","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.1161\/CIRCULATIONAHA.124.069187","volume":"150","author":"SM Cho","year":"2024","unstructured":"Cho SM, Khanduja S, Wilcox C et al (2024) Clinical use of bedside portable ultra-low-field brain magnetic resonance imaging in patients on extracorporeal membrane oxygenation: results from the multicenter SAFE MRI ECMO study. Circulation 150(24):1955\u20131965. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.124.069187","journal-title":"Circulation"},{"issue":"6","key":"2091_CR33","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics14060606","volume":"14","author":"SM Cho","year":"2024","unstructured":"Cho SM, Khanduja S, Kim J et al (2024) Detection of acute brain injury in intensive care unit patients on ECMO support using ultra-low-field portable MRI: a retrospective analysis compared to head CT. Diagnostics 14(6):606. https:\/\/doi.org\/10.3390\/diagnostics14060606","journal-title":"Diagnostics"},{"issue":"3","key":"2091_CR34","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1017\/cjn.2023.250","volume":"51","author":"CN DesRoche","year":"2024","unstructured":"DesRoche CN, Johnson AP, Hore EB et al (2024) Feasibility and cost analysis of portable MRI implementation in a remote setting in Canada. Can J Neurol Sci 51(3):387\u2013396. https:\/\/doi.org\/10.1017\/cjn.2023.250","journal-title":"Can J Neurol Sci"},{"issue":"1","key":"2091_CR35","doi-asserted-by":"publisher","DOI":"10.1111\/jon.70005","volume":"35","author":"SV Okar","year":"2025","unstructured":"Okar SV, Nair G, Kawatra KD et al (2025) High-field-blinded assessment of portable ultra-low-field brain MRI for multiple sclerosis. J Neuroimaging 35(1):e70005. https:\/\/doi.org\/10.1111\/jon.70005","journal-title":"J Neuroimaging"},{"key":"2091_CR36","doi-asserted-by":"publisher","first-page":"212","DOI":"10.25259\/SNI_124_2023","volume":"14","author":"A Altaf","year":"2023","unstructured":"Altaf A, Baqai MWS, Urooj F et al (2023) Intraoperative use of ultra-low-field, portable magnetic resonance imaging - first report. Surg Neurol Int 14:212. https:\/\/doi.org\/10.25259\/SNI_124_2023","journal-title":"Surg Neurol Int"},{"key":"2091_CR37","doi-asserted-by":"publisher","DOI":"10.1111\/epi.18273","author":"T Bauer","year":"2025","unstructured":"Bauer T, Sabir H, Baumgartner T et al (2025) Portable ultra-low-field magnetic resonance imaging enables postictal seizure imaging. Epilepsia. https:\/\/doi.org\/10.1111\/epi.18273","journal-title":"Epilepsia"},{"issue":"3","key":"2091_CR38","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s00415-025-12938-z","volume":"272","author":"SV Okar","year":"2025","unstructured":"Okar SV, Kawatra KD, Thommana AA et al (2025) Portable ultra-low-field MRI for progressive multifocal leukoencephalopathy: case studies, sensitivity, and potential applications. J Neurol 272(3):193. https:\/\/doi.org\/10.1007\/s00415-025-12938-z","journal-title":"J Neurol"},{"issue":"5","key":"2091_CR39","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1192\/bjp.2024.185","volume":"225","author":"J Rodda","year":"2024","unstructured":"Rodda J, Dobrzanski J, Shergill S (2024) Portable ultra-low-field MRI: scanning new horizons in dementia detection. Br J Psychiatry J Ment Sci 225(5):506\u2013507. https:\/\/doi.org\/10.1192\/bjp.2024.185","journal-title":"Br J Psychiatry J Ment Sci"},{"key":"2091_CR40","doi-asserted-by":"publisher","first-page":"1220091","DOI":"10.3389\/fneur.2023.1220091","volume":"14","author":"O Islam","year":"2023","unstructured":"Islam O, Lin AW, Bharatha A (2023) Potential application of ultra-low field portable MRI in the ICU to improve CT and MRI access in Canadian hospitals: a multi-center retrospective analysis. Front Neurol 14:1220091. https:\/\/doi.org\/10.3389\/fneur.2023.1220091","journal-title":"Front Neurol"},{"issue":"12","key":"2091_CR41","doi-asserted-by":"publisher","first-page":"3607","DOI":"10.1111\/epi.18171","volume":"65","author":"T Bauer","year":"2024","unstructured":"Bauer T, Olbrich S, Groteklaes A et al (2024) Proof of concept: portable ultra-low-field magnetic resonance imaging for the diagnosis of epileptogenic brain pathologies. Epilepsia 65(12):3607\u20133618. https:\/\/doi.org\/10.1111\/epi.18171","journal-title":"Epilepsia"},{"issue":"7","key":"2091_CR42","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4992","volume":"37","author":"S Murali","year":"2024","unstructured":"Murali S, Ding H, Adedeji F et al (2024) Bringing MRI to low- and middle-income countries: directions, challenges and potential solutions. NMR Biomed 37(7):e4992. https:\/\/doi.org\/10.1002\/nbm.4992","journal-title":"NMR Biomed"},{"issue":"4","key":"2091_CR43","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/j.nic.2008.06.004","volume":"18","author":"JC McGowan","year":"2008","unstructured":"McGowan JC (2008) Basic principles of magnetic resonance imaging. Neuroimaging Clin N Am 18(4):623\u2013636. https:\/\/doi.org\/10.1016\/j.nic.2008.06.004","journal-title":"Neuroimaging Clin N Am"},{"key":"2091_CR44","doi-asserted-by":"publisher","first-page":"93","DOI":"10.12659\/PJR.892628","volume":"80","author":"K Krupa","year":"2015","unstructured":"Krupa K, Bekiesi\u0144ska-Figatowska M (2015) Artifacts in magnetic resonance imaging. Pol J Radiol 80:93\u2013106. https:\/\/doi.org\/10.12659\/PJR.892628","journal-title":"Pol J Radiol"},{"issue":"6","key":"2091_CR45","doi-asserted-by":"publisher","first-page":"1528","DOI":"10.1002\/jmri.26637","volume":"49","author":"JP Marques","year":"2019","unstructured":"Marques JP, Simonis FFJ, Webb AG (2019) Low-field MRI: an MR physics perspective. J Magn Reson Imaging 49(6):1528\u20131542. https:\/\/doi.org\/10.1002\/jmri.26637","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2091_CR46","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1136\/archdischild-2022-324200","volume":"108","author":"ME Sien","year":"2023","unstructured":"Sien ME, Robinson AL, Hu HH et al (2023) Feasibility of and experience using a portable MRI scanner in the neonatal intensive care unit. Arch Dis Child Fetal Neonatal Ed 108(1):45\u201350. https:\/\/doi.org\/10.1136\/archdischild-2022-324200","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"1","key":"2091_CR47","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1002\/jmri.28408","volume":"57","author":"TC Arnold","year":"2023","unstructured":"Arnold TC, Freeman CW, Litt B, Stein JM (2023) Low-field MRI: clinical promise and challenges. J Magn Reson Imaging 57(1):25\u201344. https:\/\/doi.org\/10.1002\/jmri.28408","journal-title":"J Magn Reson Imaging"},{"key":"2091_CR48","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2021.118210","volume":"238","author":"FX Shen","year":"2021","unstructured":"Shen FX, Wolf SM, Bhavnani S et al (2021) Emerging ethical issues raised by highly portable MRI research in remote and resource-limited international settings. Neuroimage 238:118210. https:\/\/doi.org\/10.1016\/j.neuroimage.2021.118210","journal-title":"Neuroimage"},{"issue":"16","key":"2091_CR49","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abm3952","volume":"8","author":"MM Yuen","year":"2022","unstructured":"Yuen MM, Prabhat AM, Mazurek MH et al (2022) Portable, low-field magnetic resonance imaging enables highly accessible and dynamic bedside evaluation of ischemic stroke. Sci Adv 8(16):eabm3952. https:\/\/doi.org\/10.1126\/sciadv.abm3952","journal-title":"Sci Adv"},{"issue":"1","key":"2091_CR50","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1148\/radiology.173.1.2781018","volume":"173","author":"L Kaufman","year":"1989","unstructured":"Kaufman L, Kramer DM, Crooks LE, Ortendahl DA (1989) Measuring signal-to-noise ratios in MR imaging. Radiology 173(1):265\u2013267. https:\/\/doi.org\/10.1148\/radiology.173.1.2781018","journal-title":"Radiology"},{"key":"2091_CR51","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/978-3-031-03873-0_3","volume":"1380","author":"AS Minhas","year":"2022","unstructured":"Minhas AS, Oliver R (2022) Magnetic resonance imaging basics. Adv Exp Med Biol 1380:47\u201382. https:\/\/doi.org\/10.1007\/978-3-031-03873-0_3","journal-title":"Adv Exp Med Biol"},{"key":"2091_CR52","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.jmr.2017.11.009","volume":"286","author":"X Huang","year":"2018","unstructured":"Huang X, Dong H, Qiu Y et al (2018) Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment. J Magn Reson 286:52\u201359. https:\/\/doi.org\/10.1016\/j.jmr.2017.11.009","journal-title":"J Magn Reson"},{"issue":"5","key":"2091_CR53","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1109\/TMI.2022.3147450","volume":"41","author":"J Su","year":"2022","unstructured":"Su J, Pellicer-Guridi R, Edwards T et al (2022) A CNN based software gradiometer for electromagnetic background noise reduction in low field MRI applications. IEEE Trans Med Imaging 41(5):1007\u20131016. https:\/\/doi.org\/10.1109\/TMI.2022.3147450","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"2091_CR54","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1002\/jmri.26942","volume":"52","author":"LL Wald","year":"2020","unstructured":"Wald LL, McDaniel PC, Witzel T, Stockmann JP, Cooley CZ (2020) Low-cost and portable MRI. J Magn Reson Imaging 52(3):686\u2013696. https:\/\/doi.org\/10.1002\/jmri.26942","journal-title":"J Magn Reson Imaging"},{"key":"2091_CR55","doi-asserted-by":"publisher","DOI":"10.1016\/j.nicl.2022.103101","volume":"35","author":"TC Arnold","year":"2022","unstructured":"Arnold TC, Tu D, Okar SV et al (2022) Sensitivity of portable low-field magnetic resonance imaging for multiple sclerosis lesions. NeuroImage Clin 35:103101. https:\/\/doi.org\/10.1016\/j.nicl.2022.103101","journal-title":"NeuroImage Clin"},{"issue":"4","key":"2091_CR56","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1002\/jmri.27865","volume":"55","author":"D Darnell","year":"2022","unstructured":"Darnell D, Truong TK, Song AW (2022) Recent advances in radio-frequency coil technologies: flexible, wireless, and integrated coil arrays. J Magn Reson Imaging 55(4):1026\u20131042. https:\/\/doi.org\/10.1002\/jmri.27865","journal-title":"J Magn Reson Imaging"},{"issue":"4","key":"2091_CR57","doi-asserted-by":"publisher","first-page":"153","DOI":"10.13104\/imri.2024.0009","volume":"28","author":"S More","year":"2024","unstructured":"More S, Zhang X (2024) Ultrashort echo time and zero echo time MRI and their applications at high magnetic fields: a literature survey. Investig Magn Reson Imaging. 28(4):153","journal-title":"Investig Magn Reson Imaging."},{"issue":"1","key":"2091_CR58","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1002\/jmri.23639","volume":"36","author":"A Deshmane","year":"2012","unstructured":"Deshmane A, Gulani V, Griswold MA, Seiberlich N (2012) Parallel MR imaging. J Magn Reson Imaging 36(1):55\u201372. https:\/\/doi.org\/10.1002\/jmri.23639","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"2091_CR59","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1109\/MSP.2007.914728","volume":"25","author":"M Lustig","year":"2008","unstructured":"Lustig M, Donoho DL, Santos JM, Pauly JM (2008) Compressed sensing MRI. IEEE Signal Process Mag 25(2):72\u201382. https:\/\/doi.org\/10.1109\/MSP.2007.914728","journal-title":"IEEE Signal Process Mag"},{"issue":"3","key":"2091_CR60","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1007\/s10334-023-01100-3","volume":"36","author":"A Webb","year":"2023","unstructured":"Webb A, O\u2019Reilly T (2023) Tackling SNR at low-field: a review of hardware approaches for point-of-care systems. Magma N Y N 36(3):375\u2013393. https:\/\/doi.org\/10.1007\/s10334-023-01100-3","journal-title":"Magma N Y N"},{"key":"2091_CR61","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2020.106775","volume":"317","author":"M Yu","year":"2020","unstructured":"Yu M, Tao Q, Dong H et al (2020) Ultra-low noise graphene\/copper\/nylon fabric for electromagnetic interference shielding in ultra-low field magnetic resonance imaging. J Magn Reson 317:106775. https:\/\/doi.org\/10.1016\/j.jmr.2020.106775","journal-title":"J Magn Reson"},{"key":"2091_CR62","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.jmr.2013.02.009","volume":"229","author":"M Espy","year":"2013","unstructured":"Espy M, Matlashov A, Volegov P (2013) SQUID-detected ultra-low field MRI. J Magn Reson 229:127\u2013141. https:\/\/doi.org\/10.1016\/j.jmr.2013.02.009","journal-title":"J Magn Reson"},{"issue":"1","key":"2091_CR63","doi-asserted-by":"publisher","first-page":"13431","DOI":"10.1038\/s41598-017-13757-7","volume":"7","author":"K Buckenmaier","year":"2017","unstructured":"Buckenmaier K, Rudolph M, Back C et al (2017) SQUID-based detection of ultra-low-field multinuclear NMR of substances hyperpolarized using signal amplification by reversible exchange. Sci Rep 7(1):13431. https:\/\/doi.org\/10.1038\/s41598-017-13757-7","journal-title":"Sci Rep"},{"issue":"6","key":"2091_CR64","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.1002\/mrm.24413","volume":"69","author":"PT Vesanen","year":"2013","unstructured":"Vesanen PT, Nieminen JO, Zevenhoven KCJ et al (2013) Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer. Magn Reson Med 69(6):1795\u20131804. https:\/\/doi.org\/10.1002\/mrm.24413","journal-title":"Magn Reson Med"},{"issue":"1","key":"2091_CR65","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0029-554X(80)90094-4","volume":"169","author":"K Halbach","year":"1980","unstructured":"Halbach K (1980) Design of permanent multipole magnets with oriented rare earth cobalt material. Nucl Instrum Methods 169(1):1\u201310. https:\/\/doi.org\/10.1016\/0029-554X(80)90094-4","journal-title":"Nucl Instrum Methods"},{"issue":"1","key":"2091_CR66","doi-asserted-by":"publisher","DOI":"10.1109\/TMAG.2017.2751001","volume":"54","author":"CZ Cooley","year":"2018","unstructured":"Cooley CZ, Haskell MW, Cauley SF et al (2018) Design of sparse Halbach magnet arrays for portable MRI using a genetic algorithm. IEEE Trans Magn 54(1):5100112. https:\/\/doi.org\/10.1109\/TMAG.2017.2751001","journal-title":"IEEE Trans Magn"},{"key":"2091_CR67","unstructured":"(ISMRM 2019) The design of a homogenous large-bore Halbach array for low field MRI. Accessed April 14, 2025. https:\/\/archive.ismrm.org\/2019\/0272.html"},{"issue":"2","key":"2091_CR68","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1002\/mrm.25147","volume":"73","author":"CZ Cooley","year":"2015","unstructured":"Cooley CZ, Stockmann JP, Armstrong BD et al (2015) Two-dimensional imaging in a lightweight portable MRI scanner without gradient coils. Magn Reson Med 73(2):872\u2013883. https:\/\/doi.org\/10.1002\/mrm.25147","journal-title":"Magn Reson Med"},{"issue":"3","key":"2091_CR69","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1038\/s41551-020-00641-5","volume":"5","author":"CZ Cooley","year":"2020","unstructured":"Cooley CZ, McDaniel PC, Stockmann JP et al (2020) A portable scanner for magnetic resonance imaging of the brain. Nat Biomed Eng 5(3):229\u2013239. https:\/\/doi.org\/10.1038\/s41551-020-00641-5","journal-title":"Nat Biomed Eng"},{"issue":"6","key":"2091_CR70","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1007\/s00723-022-01470-2","volume":"53","author":"S Shen","year":"2022","unstructured":"Shen S, Koonjoo N, Kong X, Rosen MS, Xu Z (2022) Gradient coil design and optimization for an ultra-low-field MRI system. Appl Magn Reson 53(6):895\u2013914. https:\/\/doi.org\/10.1007\/s00723-022-01470-2","journal-title":"Appl Magn Reson"},{"issue":"12","key":"2091_CR71","doi-asserted-by":"publisher","DOI":"10.1097\/CCE.0000000000000306","volume":"2","author":"J Turpin","year":"2020","unstructured":"Turpin J, Unadkat P, Thomas J et al (2020) Portable magnetic resonance imaging for ICU patients. Crit Care Explor 2(12):e0306. https:\/\/doi.org\/10.1097\/CCE.0000000000000306","journal-title":"Crit Care Explor"},{"key":"2091_CR72","doi-asserted-by":"publisher","first-page":"107269","DOI":"10.1016\/j.jmr.2022.107269","volume":"342","author":"S Shen","year":"2022","unstructured":"Shen S, Kong X, Fanqin M et al (2022) An optimized quadrature RF receive coil for very-low-field (50.4 mT) magnetic resonance brain imaging. J Magn Reson. 342:107269. https:\/\/doi.org\/10.1016\/j.jmr.2022.107269","journal-title":"J Magn Reson."},{"issue":"24","key":"2091_CR73","doi-asserted-by":"publisher","DOI":"10.3390\/electronics11244233","volume":"11","author":"G Giovannetti","year":"2022","unstructured":"Giovannetti G, Frijia F, Flori A (2022) Radiofrequency coils for low-field (0.18\u20130.55 T) magnetic resonance scanners: experience from a research lab-manufacturing companies cooperation. Electronics 11(24):4233. https:\/\/doi.org\/10.3390\/electronics11244233","journal-title":"Electronics"},{"issue":"1","key":"2091_CR74","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5268","volume":"38","author":"R Ayde","year":"2025","unstructured":"Ayde R, Vornehm M, Zhao Y, Knoll F, Wu EX, Sarracanie M (2025) MRI at low field: a review of software solutions for improving SNR. NMR Biomed 38(1):e5268. https:\/\/doi.org\/10.1002\/nbm.5268","journal-title":"NMR Biomed"},{"issue":"2","key":"2091_CR75","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1002\/mrm.1910160212","volume":"16","author":"HW Fischer","year":"1990","unstructured":"Fischer HW, Rinck PA, Van Haverbeke Y, Muller RN (1990) Nuclear relaxation of human brain gray and white matter: analysis of field dependence and implications for MRI. Magn Reson Med 16(2):317\u2013334. https:\/\/doi.org\/10.1002\/mrm.1910160212","journal-title":"Magn Reson Med"},{"key":"2091_CR76","doi-asserted-by":"crossref","unstructured":"Volegov P, Flynn M, Kraus R et al. Magnetic Resonance relaxometry at low and ultra low fields. In: Supek S, Su\u0161ac A, eds. 17th International Conference on Biomagnetism Advances in Biomagnetism \u2013 Biomag2010. Springer Berlin Heidelberg; 2010:82-87.","DOI":"10.1007\/978-3-642-12197-5_15"},{"issue":"2","key":"2091_CR77","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1002\/mrm.29009","volume":"87","author":"T O\u2019Reilly","year":"2022","unstructured":"O\u2019Reilly T, Webb AG (2022) In vivo T1 and T2 relaxation time maps of brain tissue, skeletal muscle, and lipid measured in healthy volunteers at 50 mT. Magn Reson Med 87(2):884\u2013895. https:\/\/doi.org\/10.1002\/mrm.29009","journal-title":"Magn Reson Med"},{"issue":"3","key":"2091_CR78","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1002\/mrm.20605","volume":"54","author":"GJ Stanisz","year":"2005","unstructured":"Stanisz GJ, Odrobina EE, Pun J et al (2005) T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 54(3):507\u2013512. https:\/\/doi.org\/10.1002\/mrm.20605","journal-title":"Magn Reson Med"},{"issue":"1","key":"2091_CR79","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.neuroimage.2009.05.051","volume":"48","author":"K Uluda\u011f","year":"2009","unstructured":"Uluda\u011f K, M\u00fcller-Bierl B, U\u011furbil K (2009) An integrative model for neuronal activity-induced signal changes for gradient and spin echo functional imaging. Neuroimage 48(1):150\u2013165. https:\/\/doi.org\/10.1016\/j.neuroimage.2009.05.051","journal-title":"Neuroimage"},{"issue":"6","key":"2091_CR80","doi-asserted-by":"publisher","first-page":"2420","DOI":"10.1002\/mrm.30231","volume":"92","author":"S Su","year":"2024","unstructured":"Su S, Zhao Y, Ding Y et al (2024) Ultra-low-field magnetization transfer imaging at 0.055T with low specific absorption rate. Magn Reson Med 92(6):2420\u20132432. https:\/\/doi.org\/10.1002\/mrm.30231","journal-title":"Magn Reson Med"},{"issue":"3","key":"2091_CR81","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1002\/mrm.29273","volume":"88","author":"SCL Deoni","year":"2022","unstructured":"Deoni SCL, O\u2019Muircheartaigh J, Ljungberg E, Huentelman M, Williams SCR (2022) Simultaneous high-resolution T2 -weighted imaging and quantitative T2 mapping at low magnetic field strengths using a multiple TE and multi-orientation acquisition approach. Magn Reson Med 88(3):1273\u20131281. https:\/\/doi.org\/10.1002\/mrm.29273","journal-title":"Magn Reson Med"},{"issue":"2","key":"2091_CR82","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1002\/mrm.29642","volume":"90","author":"V Lau","year":"2023","unstructured":"Lau V, Xiao L, Zhao Y et al (2023) Pushing the limits of low-cost ultra-low-field MRI by dual-acquisition deep learning 3D superresolution. Magn Reson Med 90(2):400\u2013416. https:\/\/doi.org\/10.1002\/mrm.29642","journal-title":"Magn Reson Med"},{"key":"2091_CR83","doi-asserted-by":"publisher","first-page":"1330203","DOI":"10.3389\/fneur.2024.1330203","volume":"15","author":"C Donnay","year":"2024","unstructured":"Donnay C, Okar SV, Tsagkas C et al (2024) Super resolution using sparse sampling at portable ultra-low field MR. Front Neurol 15:1330203. https:\/\/doi.org\/10.3389\/fneur.2024.1330203","journal-title":"Front Neurol"},{"key":"2091_CR84","doi-asserted-by":"publisher","unstructured":"Liu Z, Tao Q, Ren X et al. Denoising and segmentation of ultra-low field magnetic resonance imaging based on TriNet. In: Proceedings of the 2024 8th International conference on electronic information technology and computer engineering. ACM; 2024:202\u2013208. https:\/\/doi.org\/10.1145\/3711129.3711166","DOI":"10.1145\/3711129.3711166"},{"key":"2091_CR85","doi-asserted-by":"publisher","DOI":"10.1109\/TAI.2025.3556997","author":"Y Hu","year":"2025","unstructured":"Hu Y, Huang Y, Qu S, Xie Y, Fang Y, Zhang X (2025) Deep-learning-based dual denoising algorithm for shielding-free magnetic resonance imaging. IEEE Trans Artif Intell. https:\/\/doi.org\/10.1109\/TAI.2025.3556997","journal-title":"IEEE Trans Artif Intell."},{"key":"2091_CR86","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30600","author":"Y Zhang","year":"2025","unstructured":"Zhang Y, He W, Wu J, Xu Z (2025) Dual-scan self-learning denoising for application in ultralow-field MRI. Magn Reson Med. https:\/\/doi.org\/10.1002\/mrm.30600","journal-title":"Magn Reson Med"},{"key":"2091_CR87","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2024.107812","volume":"370","author":"A Salehi","year":"2025","unstructured":"Salehi A, Mach M, Najac C et al (2025) Denoising low-field MR images with a deep learning algorithm based on simulated data from easily accessible open-source software. J Magn Reson 370:107812. https:\/\/doi.org\/10.1016\/j.jmr.2024.107812","journal-title":"J Magn Reson"},{"issue":"1","key":"2091_CR88","doi-asserted-by":"publisher","first-page":"8248","DOI":"10.1038\/s41598-021-87482-7","volume":"11","author":"N Koonjoo","year":"2021","unstructured":"Koonjoo N, Zhu B, Bagnall GC, Bhutto D, Rosen MS (2021) Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction. Sci Rep 11(1):8248. https:\/\/doi.org\/10.1038\/s41598-021-87482-7","journal-title":"Sci Rep"},{"key":"2091_CR89","unstructured":"Advanced Image Reconstruction: Swoop\u00ae Portable MRITM. Accessed August 11, 2025. https:\/\/www.hyperfine.io\/swoop\/advanced-image-reconstruction"},{"issue":"4","key":"2091_CR90","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/MAT.0000000000002368","volume":"71","author":"S Khanduja","year":"2025","unstructured":"Khanduja S, Kang JK, Chinedozi ID et al (2025) Ultra-low-field portable brain magnetic resonance imaging in patients with cardiac devices: current evidence and future directions. ASAIO J 71(4):277\u2013282. https:\/\/doi.org\/10.1097\/MAT.0000000000002368","journal-title":"ASAIO J"},{"key":"2091_CR91","doi-asserted-by":"publisher","DOI":"10.1017\/cjn.2024.346","author":"C DesRoche","year":"2024","unstructured":"DesRoche C, Innes E, Silver I et al (2024) Utility of Novel ultra-low-field portable MRI in a remote setting in Canada. Can J Neurol Sci. https:\/\/doi.org\/10.1017\/cjn.2024.346","journal-title":"Can J Neurol Sci"},{"issue":"2","key":"2091_CR92","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1002\/jmri.27324","volume":"54","author":"SS Bhat","year":"2021","unstructured":"Bhat SS, Fernandes TT, Poojar P et al (2021) Low-field MRI of stroke: challenges and opportunities. J Magn Reson Imaging 54(2):372\u2013390. https:\/\/doi.org\/10.1002\/jmri.27324","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2091_CR93","doi-asserted-by":"publisher","DOI":"10.3171\/CASE23225","volume":"6","author":"A Abbas","year":"2023","unstructured":"Abbas A, Hilal K, Rasool AA, Zahidi UF, Shamim MS, Abbas Q (2023) Low-field magnetic resonance imaging in a boy with intracranial bolt after severe traumatic brain injury: illustrative case. J Neurosurg Case Lessons 6(1):CASE23225. https:\/\/doi.org\/10.3171\/CASE23225","journal-title":"J Neurosurg Case Lessons"},{"issue":"2","key":"2091_CR94","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1227\/01.NEU.0000312362.63693.78","volume":"63","author":"R Gerlach","year":"2008","unstructured":"Gerlach R, du Mesnil de Rochemont R, Gasser T et al (2008) Feasibility of Polestar N20, an ultra-low-field intraoperative magnetic resonance imaging system in resection control of pituitary macroadenomas: lessons learned from the first 40 cases. Neurosurgery 63(2):272\u2013284. https:\/\/doi.org\/10.1227\/01.NEU.0000312362.63693.78","journal-title":"Neurosurgery"},{"issue":"1","key":"2091_CR95","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.wneu.2012.05.032","volume":"79","author":"M Hlavica","year":"2013","unstructured":"Hlavica M, Bellut D, Lemm D, Schmid C, Bernays RL (2013) Impact of ultra-low-field intraoperative magnetic resonance imaging on extent of resection and frequency of tumor recurrence in 104 surgically treated nonfunctioning pituitary adenomas. World Neurosurg 79(1):99\u2013109. https:\/\/doi.org\/10.1016\/j.wneu.2012.05.032","journal-title":"World Neurosurg"},{"key":"2091_CR96","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1007\/978-3-211-99651-5_12","volume":"109","author":"R Gerlach","year":"2011","unstructured":"Gerlach R, de Rochemont RM, Gasser T, Marquardt G, Imoehl L, Seifert V (2011) Implementation of the ultra low field intraoperative MRI PoleStar N20 during resection control of pituitary adenomas. Acta Neurochir Suppl 109:73\u201379","journal-title":"Acta Neurochir Suppl"},{"key":"2091_CR97","doi-asserted-by":"publisher","DOI":"10.3389\/fnimg.2025.1507522","volume":"4","author":"A Altaf","year":"2025","unstructured":"Altaf A, Alam MS, Khan S et al (2025) Initial insights into post-contrast enhancement in ultra-low-field MRI: case report. Front Neuroimaging 4:1507522. https:\/\/doi.org\/10.3389\/fnimg.2025.1507522","journal-title":"Front Neuroimaging"},{"issue":"5","key":"2091_CR98","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1002\/jso.21508","volume":"101","author":"C Senft","year":"2010","unstructured":"Senft C, Ulrich CT, Seifert V, Gasser T (2010) Intraoperative magnetic resonance imaging in the surgical treatment of cerebral metastases. J Surg Oncol 101(5):436\u2013441. https:\/\/doi.org\/10.1002\/jso.21508","journal-title":"J Surg Oncol"},{"issue":"4","key":"2091_CR99","doi-asserted-by":"publisher","DOI":"10.3171\/2010.7.FOCUS10164","volume":"29","author":"D Bellut","year":"2010","unstructured":"Bellut D, Hlavica M, Schmid C, Bernays RL (2010) Intraoperative magnetic resonance imaging-assisted transsphenoidal pituitary surgery in patients with acromegaly. Neurosurg Focus 29(4):E9. https:\/\/doi.org\/10.3171\/2010.7.FOCUS10164","journal-title":"Neurosurg Focus"},{"issue":"2","key":"2091_CR100","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/0730-725x(89)90708-x","volume":"7","author":"Y Freund-Levi","year":"1989","unstructured":"Freund-Levi Y, S\u00e4\u00e4f J, Wahlund LO, Wetterberg L (1989) Ultra low field brain MRI in HIV transfusion infected patients. Magn Reson Imaging 7(2):225\u2013230. https:\/\/doi.org\/10.1016\/0730-725x(89)90708-x","journal-title":"Magn Reson Imaging"},{"issue":"11","key":"2091_CR101","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5213","volume":"37","author":"S Su","year":"2024","unstructured":"Su S, Hu J, Ding Y et al (2024) Ultra-low-field magnetic resonance angiography at 0.05 T: a preliminary study. NMR Biomed 37(11):e5213. https:\/\/doi.org\/10.1002\/nbm.5213","journal-title":"NMR Biomed"},{"issue":"2","key":"2091_CR102","doi-asserted-by":"publisher","first-page":"218","DOI":"10.5137\/1019-5149.JTN.5615-11.0","volume":"22","author":"S Kaya","year":"2012","unstructured":"Kaya S, Deniz S, Duz B, Daneyemez M, Gonul E (2012) Use of an ultra-low field intraoperative MRI system for pediatric brain tumor cases: initial experience with \u201cPoleStar N20.\u201d Turk Neurosurg 22(2):218\u2013225. https:\/\/doi.org\/10.5137\/1019-5149.JTN.5615-11.0","journal-title":"Turk Neurosurg"},{"issue":"4 Suppl 2","key":"2091_CR103","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1227\/01.NEU.0000313624.77452.3C","volume":"63","author":"C Senft","year":"2008","unstructured":"Senft C, Seifert V, Hermann E, Franz K, Gasser T (2008) Usefulness of intraoperative ultra low-field magnetic resonance imaging in glioma surgery. Neurosurgery. 63(4 Suppl 2):257\u2013266. https:\/\/doi.org\/10.1227\/01.NEU.0000313624.77452.3C","journal-title":"Neurosurgery."},{"key":"2091_CR104","unstructured":"Details and Specs: Swoop\u00ae Portable MR Imaging\u00ae System. Accessed May 18, 2025. http:\/\/www.hyperfine.io\/swoop\/details-and-specifications"},{"key":"2091_CR105","doi-asserted-by":"publisher","DOI":"10.25259\/SNI_162_2024","volume":"15","author":"A Altaf","year":"2024","unstructured":"Altaf A, Shakir M, Irshad HA et al (2024) Applications, limitations and advancements of ultra-low-field magnetic resonance imaging: a scoping review. Surg Neurol Int 15:218. https:\/\/doi.org\/10.25259\/SNI_162_2024","journal-title":"Surg Neurol Int"},{"issue":"1","key":"2091_CR106","doi-asserted-by":"publisher","first-page":"5119","DOI":"10.1038\/s41467-021-25441-6","volume":"12","author":"MH Mazurek","year":"2021","unstructured":"Mazurek MH, Cahn BA, Yuen MM et al (2021) Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage. Nat Commun 12(1):5119. https:\/\/doi.org\/10.1038\/s41467-021-25441-6","journal-title":"Nat Commun"},{"key":"2091_CR107","doi-asserted-by":"publisher","DOI":"10.25259\/SNI_123_2023","volume":"14","author":"A Altaf","year":"2023","unstructured":"Altaf A, Baqai MWS, Urooj F et al (2023) Utilization of an ultra-low-field, portable magnetic resonance imaging for brain tumor assessment in lower middle-income countries. Surg Neurol Int 14:260. https:\/\/doi.org\/10.25259\/SNI_123_2023","journal-title":"Surg Neurol Int"},{"issue":"2","key":"2091_CR108","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1177\/028418519203300201","volume":"33","author":"M Fagerlund","year":"1992","unstructured":"Fagerlund M, Bj\u00f6rnebrink J, Ekelund L, Toolanen G (1992) Ultra low field MR imaging of cervical spine involvement in rheumatoid arthritis. Acta Radiol 33(2):89\u201392","journal-title":"Acta Radiol"},{"issue":"1","key":"2091_CR109","doi-asserted-by":"publisher","first-page":"11","DOI":"10.3171\/2025.1.PEDS24358","volume":"36","author":"MD Gruber","year":"2025","unstructured":"Gruber MD, Unadkat P, Morales DM et al (2025) Ultra-low-field portable MRI for assessing ventricular size in pediatric hydrocephalus: a feasibility study. J Neurosurg Pediatr 36(1):11\u201319. https:\/\/doi.org\/10.3171\/2025.1.PEDS24358","journal-title":"J Neurosurg Pediatr"},{"issue":"1","key":"2091_CR110","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/WCO.0000000000001338","volume":"38","author":"J Zabinska","year":"2025","unstructured":"Zabinska J, de Havenon A, Sheth KN (2025) Recent advances in portable, low-field magnetic resonance imaging in cerebrovascular disease. Curr Opin Neurol 38(1):35\u201339. https:\/\/doi.org\/10.1097\/WCO.0000000000001338","journal-title":"Curr Opin Neurol"},{"issue":"1","key":"2091_CR111","doi-asserted-by":"publisher","first-page":"10488","DOI":"10.1038\/s41467-024-54972-x","volume":"15","author":"AJ Sorby-Adams","year":"2024","unstructured":"Sorby-Adams AJ, Guo J, Laso P et al (2024) Portable, low-field magnetic resonance imaging for evaluation of Alzheimer\u2019s disease. Nat Commun 15(1):10488. https:\/\/doi.org\/10.1038\/s41467-024-54972-x","journal-title":"Nat Commun"},{"issue":"10284","key":"2091_CR112","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1016\/S0140-6736(20)32205-4","volume":"397","author":"P Scheltens","year":"2021","unstructured":"Scheltens P, De Strooper B, Kivipelto M et al (2021) Alzheimer\u2019s disease. Lancet 397(10284):1577\u20131590. https:\/\/doi.org\/10.1016\/S0140-6736(20)32205-4","journal-title":"Lancet"},{"issue":"10","key":"2091_CR113","doi-asserted-by":"publisher","DOI":"10.1002\/hbm.70232","volume":"46","author":"P Hsu","year":"2025","unstructured":"Hsu P, Marchetto E, Sodickson DK, Johnson PM, Veraart J (2025) Morphological brain analysis using ultra low-field MRI. Hum Brain Mapp 46(10):e70232. https:\/\/doi.org\/10.1002\/hbm.70232","journal-title":"Hum Brain Mapp"},{"key":"2091_CR114","doi-asserted-by":"publisher","first-page":"1588487","DOI":"10.3389\/fnimg.2025.1588487","volume":"4","author":"KT Islam","year":"2025","unstructured":"Islam KT, Zhong S, Zakavi P et al (2025) AI improves consistency in regional brain volumes measured in ultra-low-field MRI and 3T MRI. Front Neuroimaging 4:1588487. https:\/\/doi.org\/10.3389\/fnimg.2025.1588487","journal-title":"Front Neuroimaging"},{"key":"2091_CR115","doi-asserted-by":"publisher","DOI":"10.1016\/j.msard.2024.105515","volume":"85","author":"AS Ham","year":"2024","unstructured":"Ham AS, Hacker CT, Guo J, Sorby-Adams A, Kimberly WT, Mateen FJ (2024) Feasibility and tolerability of portable, low-field brain MRI for patients with multiple sclerosis. Mult Scler Relat Disord 85:105515. https:\/\/doi.org\/10.1016\/j.msard.2024.105515","journal-title":"Mult Scler Relat Disord"},{"issue":"11","key":"2091_CR116","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.3174\/ajnr.A8395","volume":"45","author":"TR Lim","year":"2024","unstructured":"Lim TR, Suthiphosuwan S, Micieli J et al (2024) Low-field (64 mT) portable MRI for rapid point-of-care diagnosis of dissemination in space in patients presenting with optic neuritis. AJNR Am J Neuroradiol 45(11):1819\u20131825. https:\/\/doi.org\/10.3174\/ajnr.A8395","journal-title":"AJNR Am J Neuroradiol"},{"issue":"8","key":"2091_CR117","doi-asserted-by":"publisher","DOI":"10.1002\/hbm.70217","volume":"46","author":"E Ljungberg","year":"2025","unstructured":"Ljungberg E, Padormo F, Poorman M et al (2025) Characterization of portable ultra-low field MRI scanners for multi-center structural neuroimaging. Hum Brain Mapp 46(8):e70217. https:\/\/doi.org\/10.1002\/hbm.70217","journal-title":"Hum Brain Mapp"},{"issue":"5","key":"2091_CR118","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1007\/s003300050781","volume":"9","author":"PA Rinck","year":"1999","unstructured":"Rinck PA, Muller RN (1999) Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents. Eur Radiol 9(5):998\u20131004. https:\/\/doi.org\/10.1007\/s003300050781","journal-title":"Eur Radiol"},{"issue":"Suppl_1","key":"2091_CR119","doi-asserted-by":"publisher","DOI":"10.1161\/str.55.suppl_1.128","volume":"55","author":"A Sorby-Adams","year":"2024","unstructured":"Sorby-Adams A, Kirsch J, Guo J et al (2024) Abstract 128: multi-direction diffusion weighted imaging on portable, low-field magnetic resonance imaging. Stroke 55(Suppl_1):A128\u2013A128. https:\/\/doi.org\/10.1161\/str.55.suppl_1.128","journal-title":"Stroke"},{"issue":"6","key":"2091_CR120","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1177\/15910199241286756","volume":"30","author":"MS Patel","year":"2024","unstructured":"Patel MS, Mannix N, Carfora A, Nimjee SM (2024) Utilizing a portable magnetic resonance imaging (MRI) in the setting of an acute ischemic stroke in a patient with a cardiac implantable electronic device. Interv Neuroradiol 30(6):862\u2013865. https:\/\/doi.org\/10.1177\/15910199241286756","journal-title":"Interv Neuroradiol"},{"issue":"11","key":"2091_CR121","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.122.029242","volume":"12","author":"A de Havenon","year":"2023","unstructured":"de Havenon A, Parasuram NR, Crawford AL et al (2023) Identification of white matter hyperintensities in routine emergency department visits using portable bedside magnetic resonance imaging. J Am Heart Assoc 12(11):e029242. https:\/\/doi.org\/10.1161\/JAHA.122.029242","journal-title":"J Am Heart Assoc"},{"issue":"1","key":"2091_CR122","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2023-075614","volume":"14","author":"M Foschi","year":"2024","unstructured":"Foschi M, Galante A, Ornello R et al (2024) Point-of-care low-field MRI in acute stroke (POCS): protocol for a multicentric prospective open-label study evaluating diagnostic accuracy. BMJ Open 14(1):e075614. https:\/\/doi.org\/10.1136\/bmjopen-2023-075614","journal-title":"BMJ Open"},{"key":"2091_CR123","doi-asserted-by":"publisher","DOI":"10.1177\/23969873251344761","author":"NM von Danwitz","year":"2025","unstructured":"von Danwitz NM, Lehnen NC, Mei\u00dfner JN et al (2025) Portable ultra-low-field MRI in acute stroke care: a pilot study. Eur Stroke J. https:\/\/doi.org\/10.1177\/23969873251344761","journal-title":"Eur Stroke J"},{"issue":"1","key":"2091_CR124","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1038\/s41598-021-03892-7","volume":"12","author":"KN Sheth","year":"2022","unstructured":"Sheth KN, Yuen MM, Mazurek MH et al (2022) Bedside detection of intracranial midline shift using portable magnetic resonance imaging. Sci Rep 12(1):67. https:\/\/doi.org\/10.1038\/s41598-021-03892-7","journal-title":"Sci Rep"},{"key":"2091_CR125","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A8811","author":"V Mathew","year":"2025","unstructured":"Mathew V, Lim TR, Nair A et al (2025) Portable bedside low-field MRI for assessment of ventricular size. AJNR Am J Neuroradiol. https:\/\/doi.org\/10.3174\/ajnr.A8811","journal-title":"AJNR Am J Neuroradiol"},{"key":"2091_CR126","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-025-02327-9","author":"K Hilal","year":"2025","unstructured":"Hilal K, Abbas Q, Abdul Rasool A et al (2025) Feasibility and clinical utility of low-field magnetic resonance imaging in critically ill children: an experience from Pakistan. Neurocrit Care. https:\/\/doi.org\/10.1007\/s12028-025-02327-9","journal-title":"Neurocrit Care"},{"key":"2091_CR127","doi-asserted-by":"publisher","first-page":"357","DOI":"10.25259\/SNI_510_2023","volume":"14","author":"A Altaf","year":"2023","unstructured":"Altaf A, Shakir M, Malik MJA et al (2023) Intraoperative use of low-field magnetic resonance imaging for brain tumors: a systematic review. Surg Neurol Int 14:357. https:\/\/doi.org\/10.25259\/SNI_510_2023","journal-title":"Surg Neurol Int"},{"issue":"6","key":"2091_CR128","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.3171\/2023.5.JNS23174","volume":"139","author":"CS Hong","year":"2023","unstructured":"Hong CS, Lamsam LA, Yadlapalli V et al (2023) Portable MRI to assess optic chiasm decompression after endoscopic endonasal resection of sellar and suprasellar lesions. J Neurosurg 139(6):1664\u20131670. https:\/\/doi.org\/10.3171\/2023.5.JNS23174","journal-title":"J Neurosurg"},{"key":"2091_CR129","unstructured":"Coronavirus disease (COVID-19) pandemic. Accessed April 26, 2025. https:\/\/www.who.int\/europe\/emergencies\/situations\/covid-19"},{"issue":"4","key":"2091_CR130","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/s00062-015-0469-9","volume":"26","author":"M Marrale","year":"2016","unstructured":"Marrale M, Collura G, Brai M et al (2016) Physics, techniques and review of neuroradiological applications of diffusion kurtosis imaging (DKI). Clin Neuroradiol 26(4):391\u2013403. https:\/\/doi.org\/10.1007\/s00062-015-0469-9","journal-title":"Clin Neuroradiol"},{"issue":"1","key":"2091_CR131","doi-asserted-by":"publisher","first-page":"4487","DOI":"10.1038\/s41467-024-48390-2","volume":"15","author":"R Picazo-Frutos","year":"2024","unstructured":"Picazo-Frutos R, Sheberstov KF, Blanchard JW et al (2024) Zero-field J-spectroscopy of quadrupolar nuclei. Nat Commun 15(1):4487. https:\/\/doi.org\/10.1038\/s41467-024-48390-2","journal-title":"Nat Commun"},{"key":"2091_CR132","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.neuroimage.2018.10.071","volume":"186","author":"K Buckenmaier","year":"2019","unstructured":"Buckenmaier K, Pedersen A, SanGiorgio P, Scheffler K, Clarke J, Inglis B (2019) Feasibility of functional MRI at ultralow magnetic field via changes in cerebral blood volume. Neuroimage 186:185\u2013191. https:\/\/doi.org\/10.1016\/j.neuroimage.2018.10.071","journal-title":"Neuroimage"},{"issue":"8","key":"2091_CR133","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1097\/RLI.0000000000000975","volume":"58","author":"S Gaur","year":"2023","unstructured":"Gaur S, Panda A, Fajardo JE, Hamilton J, Jiang Y, Gulani V (2023) Magnetic resonance fingerprinting: a review of clinical applications. Invest Radiol 58(8):561\u2013577. https:\/\/doi.org\/10.1097\/RLI.0000000000000975","journal-title":"Invest Radiol"},{"issue":"4","key":"2091_CR134","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5077","volume":"37","author":"L Xuan","year":"2024","unstructured":"Xuan L, Zhang Y, Wu J, He Y, Xu Z (2024) Quantitative brain mapping using magnetic resonance fingerprinting on a 50-mT portable MRI scanner. NMR Biomed 37(4):e5077. https:\/\/doi.org\/10.1002\/nbm.5077","journal-title":"NMR Biomed"},{"issue":"6","key":"2091_CR135","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1055\/a-1123-7944","volume":"192","author":"HM Klein","year":"2020","unstructured":"Klein HM (2020) Low-Field magnetic resonance imaging. R\u00f6Fo 192(6):537\u2013548. https:\/\/doi.org\/10.1055\/a-1123-7944","journal-title":"R\u00f6Fo"},{"issue":"5","key":"2091_CR136","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1177\/028418518903000510","volume":"30","author":"I Hovi","year":"1989","unstructured":"Hovi I, Hekali P, Korhola O et al (1989) Detection of soft-tissue and skeletal infections with ultra low-field (0.02 T) MR imaging. Acta Radiol 30(5):495\u2013499","journal-title":"Acta Radiol"},{"issue":"1","key":"2091_CR137","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/RLI.0000000000000912","volume":"58","author":"I Khodarahmi","year":"2023","unstructured":"Khodarahmi I, Keerthivasan MB, Brinkmann IM, Grodzki D, Fritz J (2023) Modern low-field MRI of the musculoskeletal system: practice considerations, opportunities, and challenges. Invest Radiol 58(1):76\u201387. https:\/\/doi.org\/10.1097\/RLI.0000000000000912","journal-title":"Invest Radiol"},{"issue":"2","key":"2091_CR138","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1148\/radiol.2019190452","volume":"293","author":"AE Campbell-Washburn","year":"2019","unstructured":"Campbell-Washburn AE, Ramasawmy R, Restivo MC et al (2019) Opportunities in interventional and diagnostic imaging by using high-performance low-field-strength MRI. Radiology 293(2):384\u2013393. https:\/\/doi.org\/10.1148\/radiol.2019190452","journal-title":"Radiology"},{"issue":"2","key":"2091_CR139","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/0730-725x(91)90008-a","volume":"9","author":"L Ekelund","year":"1991","unstructured":"Ekelund L, Bj\u00f6rnebrink J, Elmqvist LG (1991) Ultra-low-field magnetic resonance imaging of acute cruciate ligament tears. Magn Reson Imaging 9(2):179\u2013185. https:\/\/doi.org\/10.1016\/0730-725x(91)90008-a","journal-title":"Magn Reson Imaging"},{"issue":"6696","key":"2091_CR140","doi-asserted-by":"publisher","DOI":"10.1126\/science.adm7168","volume":"384","author":"Y Zhao","year":"2024","unstructured":"Zhao Y, Ding Y, Lau V et al (2024) Whole-body magnetic resonance imaging at 0.05 tesla. Science 384(6696):eadm7168. https:\/\/doi.org\/10.1126\/science.adm7168","journal-title":"Science"},{"key":"2091_CR141","unstructured":"Rosen MS (2025) A New breast cancer MRI biomarker using the intrinsic T1rho signal. clinicaltrials.gov; 2023. Accessed April 20, 2025. https:\/\/clinicaltrials.gov\/study\/NCT05486520"},{"issue":"5 Suppl","key":"2091_CR142","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.2214\/AJR.12.9116","volume":"199","author":"TRC Johnson","year":"2012","unstructured":"Johnson TRC (2012) Dual-energy CT: general principles. AJR Am J Roentgenol 199(5 Suppl):S3-8. https:\/\/doi.org\/10.2214\/AJR.12.9116","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2091_CR143","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1148\/rg.2016150185","volume":"36","author":"H Machida","year":"2016","unstructured":"Machida H, Tanaka I, Fukui R et al (2016) Dual-energy spectral CT: various clinical vascular applications. Radiographics 36(4):1215\u20131232. https:\/\/doi.org\/10.1148\/rg.2016150185","journal-title":"Radiographics"},{"issue":"4","key":"2091_CR144","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1148\/rg.304095175","volume":"30","author":"CA Coursey","year":"2010","unstructured":"Coursey CA, Nelson RC, Boll DT et al (2010) Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 30(4):1037\u20131055. https:\/\/doi.org\/10.1148\/rg.304095175","journal-title":"Radiographics"},{"issue":"7","key":"2091_CR145","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1097\/RLI.0000000000000980","volume":"58","author":"T Flohr","year":"2023","unstructured":"Flohr T, Schmidt B (2023) Technical basics and clinical benefits of photon-counting CT. Invest Radiol 58(7):441\u2013450. https:\/\/doi.org\/10.1097\/RLI.0000000000000980","journal-title":"Invest Radiol"},{"issue":"2","key":"2091_CR146","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1148\/radiol.2018172656","volume":"289","author":"MJ Willemink","year":"2018","unstructured":"Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D (2018) Photon-counting CT: technical principles and clinical prospects. Radiology 289(2):293\u2013312. https:\/\/doi.org\/10.1148\/radiol.2018172656","journal-title":"Radiology"},{"issue":"11","key":"2091_CR147","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12113627","volume":"12","author":"F Cademartiri","year":"2023","unstructured":"Cademartiri F, Meloni A, Pistoia L et al (2023) Dual-source photon-counting computed tomography-Part I: clinical overview of cardiac CT and coronary CT angiography applications. J Clin Med 12(11):3627. https:\/\/doi.org\/10.3390\/jcm12113627","journal-title":"J Clin Med"},{"issue":"11","key":"2091_CR148","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12113626","volume":"12","author":"F Cademartiri","year":"2023","unstructured":"Cademartiri F, Meloni A, Pistoia L et al (2023) Dual source photon-counting computed tomography-Part II: clinical overview of neurovascular applications. J Clin Med 12(11):3626. https:\/\/doi.org\/10.3390\/jcm12113626","journal-title":"J Clin Med"},{"issue":"7","key":"2091_CR149","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1097\/RLI.0000000000000984","volume":"58","author":"F Abel","year":"2023","unstructured":"Abel F, Schubert T, Winklhofer S (2023) Advanced neuroimaging with photon-counting detector CT. Invest Radiol 58(7):472\u2013481. https:\/\/doi.org\/10.1097\/RLI.0000000000000984","journal-title":"Invest Radiol"},{"key":"2091_CR150","unstructured":"Swoop\u00ae Portable MR Imaging\u00ae System Receives CE Marking. Accessed April 29, 2025. https:\/\/hyperfine.io\/about\/news\/press-release-hyperfine-inc-swoop-portable-mr-imaging-system-receives-ce-marking-after-meeting-comprehensive-new-eu-mdr-regulations-february-2023"},{"issue":"2","key":"2091_CR151","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1007\/s10140-025-02323-8","volume":"32","author":"YA Chen","year":"2025","unstructured":"Chen YA, Mathur S, Lin A, Knopp E, Rosen MS, Bharatha A (2025) Tips and challenges for clinical use and interpretation of low field portable MRI in neuroimaging. Emerg Radiol 32(2):279\u2013289. https:\/\/doi.org\/10.1007\/s10140-025-02323-8","journal-title":"Emerg Radiol"}],"container-title":["La radiologia medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-025-02091-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11547-025-02091-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-025-02091-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T11:20:36Z","timestamp":1764588036000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11547-025-02091-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,26]]},"references-count":151,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2091"],"URL":"https:\/\/doi.org\/10.1007\/s11547-025-02091-y","relation":{},"ISSN":["1826-6983"],"issn-type":[{"value":"1826-6983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,26]]},"assertion":[{"value":"27 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no relevant financial or nonfinancial interests to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Given the nature of the study, approval by an ethics committee was not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}