{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:20:26Z","timestamp":1792783226946,"version":"4.5.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e0 degli Studi della Campania Luigi Vanvitelli","id":[{"id":"https:\/\/ror.org\/02kqnpp86","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiol med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Pituitary adenoma consistency significantly influences surgical strategy and outcomes, yet it cannot be reliably predicted using conventional imaging. By converting images into quantitative data, radiomics can identify imaging patterns that may not be distinguishable by standard visual interpretation. This study aims to evaluate the diagnostic performance of radiomics-based MRI models for predicting pituitary adenoma consistency, to determine its potential for presurgical planning.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>A systematic search of PubMed, EMBASE, and Scopus was performed on 12\/03\/2025 following PRISMA-DTA guidelines and a pre-registered protocol (PROSPERO\/CRD420251246028). Eligible studies applied radiomics and machine learning\/deep learning to predict pituitary adenoma consistency. We performed random-effects meta-analyses to evaluate the area under the receiver operating characteristic (ROC) curve (AUC). A hierarchical summary ROC (HSROC) model estimated sensitivity and specificity. Risk of bias and study quality were assessed with QUADAS-2 and METRICS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Fourteen studies were included. The pooled discriminative performance was good (AUC\u00a0=\u00a00.86,95% C.I. [0.76;0.92],\n                      <jats:italic>I<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u00a0=\u00a092.45%,\n                      <jats:italic>k<\/jats:italic>\n                      \u00a0=\u00a014). The HSROC model showed a sensitivity\u00a0=\u00a00.74,95% C.I. [0.56;0.87] and specificity\u00a0=\u00a00.79, 95% C.I. [0.73;0.84]. No significant performance differences were observed across algorithms, dimensionality, sequence, although T2w and combined sequence models showed higher AUC trends. Risk of bias was low to moderate, and study quality was good overall. Heterogeneity resulted high and small-study effect emerged in the main analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Radiomics-based MRI models demonstrate good diagnostic performance for predicting pituitary adenoma consistency and may support presurgical assessment and planning. However, substantial heterogeneity, evidence of small-study effects, and limited external validation warrant cautious interpretation of the pooled estimates and currently restrict clinical generalizability. Future studies should prioritize multicenter external validation and standardized radiomics workflows.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11547-026-02281-2","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T13:53:39Z","timestamp":1789739619000},"page":"1841-1851","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Radiomics-based prediction of pituitary adenoma consistency: a systematic review and meta-analysis"],"prefix":"10.1007","volume":"131","author":[{"given":"Giancarlo","family":"Fusco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Caiazza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renato","family":"Cuocolo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaetano","family":"Ungaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edoardo","family":"Agosti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Domenico","family":"Solari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ferdinando","family":"Caranci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Cirillo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7811-4612","authenticated-orcid":false,"given":"Lorenzo","family":"Ugga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"issue":"4","key":"2281_CR1","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.ncl.2016.06.014","volume":"34","author":"KA McNeill","year":"2016","unstructured":"McNeill KA (2016) Epidemiology of brain tumors. Neurol Clin 34(4):981\u2013998","journal-title":"Neurol Clin"},{"issue":"3","key":"2281_CR2","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.ecl.2020.05.011","volume":"49","author":"WR van Furth","year":"2020","unstructured":"van Furth WR, de Vries F, Lobatto DJ, Kleijwegt MC, Schutte PJ, Pereira AM et al (2020) Endoscopic surgery for pituitary tumors. Endocrinol Metab Clin North Am 49(3):487\u2013503","journal-title":"Endocrinol Metab Clin North Am"},{"issue":"11","key":"2281_CR3","doi-asserted-by":"publisher","first-page":"2255","DOI":"10.1007\/s00701-018-3690-x","volume":"160","author":"C Serra","year":"2018","unstructured":"Serra C, Staartjes VE, Maldaner N, Muscas G, Akeret K, Holzmann D et al (2018) Predicting extent of resection in transsphenoidal surgery for pituitary adenoma. Acta Neurochir (Wien) 160(11):2255\u20132262","journal-title":"Acta Neurochir (Wien)"},{"issue":"5","key":"2281_CR4","doi-asserted-by":"publisher","first-page":"202","DOI":"10.2176\/nmc.42.202","volume":"42","author":"H Naganuma","year":"2002","unstructured":"Naganuma H, Satoh E, Nukui H (2002) Technical considerations of transsphenoidal removal of fibrous pituitary adenomas and evaluation of collagen content and subtype in the adenomas. Neurol Med Chir (Tokyo) 42(5):202\u2013212 (discussion 13)","journal-title":"Neurol Med Chir (Tokyo)"},{"issue":"4","key":"2281_CR5","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s11102-012-0439-z","volume":"16","author":"R Pratheesh","year":"2013","unstructured":"Pratheesh R, Rajaratnam S, Prabhu K, Mani SE, Chacko G, Chacko AG (2013) The current role of transcranial surgery in the management of pituitary adenomas. Pituitary 16(4):419\u2013434","journal-title":"Pituitary"},{"issue":"6","key":"2281_CR6","doi-asserted-by":"publisher","first-page":"1674","DOI":"10.3171\/2024.8.JNS232715","volume":"142","author":"GA Guerra","year":"2025","unstructured":"Guerra GA, Kashif Z, Cote DJ, Feng JJ, Renn A, Yang M et al (2025) Association between pituitary adenoma consistency, resection techniques, and patient outcomes: a single-institution experience. J Neurosurg 142(6):1674\u20131681","journal-title":"J Neurosurg"},{"issue":"4","key":"2281_CR7","doi-asserted-by":"publisher","first-page":"1961","DOI":"10.1007\/s00405-024-08472-9","volume":"281","author":"MIA Baban","year":"2024","unstructured":"Baban MIA, Omer SN, AlZuhairy AKA, Mahmoud AA (2024) The role of preoperative MRI in endoscopic transnasal transsphenoidal hypophysectomy of pituitary adenoma. Eur Arch Otorhinolaryngol 281(4):1961\u20131969","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"8","key":"2281_CR8","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1007\/s007010050179","volume":"140","author":"T Iuchi","year":"1998","unstructured":"Iuchi T, Saeki N, Tanaka M, Sunami K, Yamaura A (1998) MRI prediction of fibrous pituitary adenomas. Acta Neurochir (Wien) 140(8):779\u2013786","journal-title":"Acta Neurochir (Wien)"},{"issue":"6","key":"2281_CR9","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.neuchi.2017.06.003","volume":"63","author":"AK Thotakura","year":"2017","unstructured":"Thotakura AK, Patibandla MR, Panigrahi MK, Mahadevan A (2017) Is it really possible to predict the consistency of a pituitary adenoma preoperatively? Neurochirurgie 63(6):453\u2013457","journal-title":"Neurochirurgie"},{"issue":"2","key":"2281_CR10","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1148\/radiol.2015151169","volume":"278","author":"RJ Gillies","year":"2016","unstructured":"Gillies RJ, Kinahan PE, Hricak H (2016) Radiomics: images are more than pictures, they are data. Radiology 278(2):563\u2013577","journal-title":"Radiology"},{"key":"2281_CR11","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.ymeth.2020.05.022","volume":"188","author":"A Ibrahim","year":"2021","unstructured":"Ibrahim A, Primakov S, Beuque M, Woodruff HC, Halilaj I, Wu G et al (2021) Radiomics for precision medicine: current challenges, future prospects, and the proposal of a new framework. Methods 188:20\u201329","journal-title":"Methods"},{"issue":"4","key":"2281_CR12","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1001\/jama.2017.19163","volume":"319","author":"MDF McInnes","year":"2018","unstructured":"McInnes MDF, Moher D, Thombs BD, McGrath TA, Bossuyt PM, Clifford T et al (2018) Preferred reporting items for a systematic review and meta-analysis of diagnostic test accuracy studies: the PRISMA-DTA statement. JAMA 319(4):388\u2013396","journal-title":"JAMA"},{"issue":"1","key":"2281_CR13","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1148\/radiology.143.1.7063747","volume":"143","author":"JA Hanley","year":"1982","unstructured":"Hanley JA, McNeil BJ (1982) The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 143(1):29\u201336","journal-title":"Radiology"},{"issue":"9","key":"2281_CR14","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1016\/j.jclinepi.2003.12.019","volume":"57","author":"P Macaskill","year":"2004","unstructured":"Macaskill P (2004) Empirical Bayes estimates generated in a hierarchical summary ROC analysis agreed closely with those of a full Bayesian analysis. J Clin Epidemiol 57(9):925\u2013932","journal-title":"J Clin Epidemiol"},{"issue":"8","key":"2281_CR15","doi-asserted-by":"publisher","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","volume":"155","author":"PF Whiting","year":"2011","unstructured":"Whiting PF, Rutjes AW, Westwood ME, Mallett S, Deeks JJ, Reitsma JB et al (2011) QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155(8):529\u2013536","journal-title":"Ann Intern Med"},{"issue":"1","key":"2281_CR16","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s13244-023-01572-w","volume":"15","author":"B Kocak","year":"2024","unstructured":"Kocak B, Akinci D\u2019Antonoli T, Mercaldo N, Alberich-Bayarri A, Baessler B, Ambrosini I et al (2024) METhodological RadiomICs Score (METRICS): a quality scoring tool for radiomics research endorsed by EuSoMII. Insights Imaging 15(1):8","journal-title":"Insights Imaging"},{"issue":"1","key":"2281_CR17","doi-asserted-by":"publisher","DOI":"10.1186\/s13244-025-02061-y","volume":"16","author":"B Kocak","year":"2025","unstructured":"Kocak B, Ammirabile A, Ambrosini I, Akinci D\u2019Antonoli T, Borgheresi A, Cavallo AU et al (2025) Explanation and elaboration with examples for METRICS (METRICS-E3): an initiative from the EuSoMII Radiomics Auditing Group. Insights Imaging 16(1):175","journal-title":"Insights Imaging"},{"key":"2281_CR18","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d549","author":"RD Riley","year":"2011","unstructured":"Riley RD, Higgins JP, Deeks JJ (2011) Interpretation of random effects meta-analyses. BMJ. https:\/\/doi.org\/10.1136\/bmj.d549","journal-title":"BMJ"},{"key":"2281_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.18637\/jss.v036.i03","volume":"36","author":"W Viechtbauer","year":"2010","unstructured":"Viechtbauer W (2010) Conducting meta-analyses in R with the metafor package. J Stat Softw 36:1\u201348","journal-title":"J Stat Softw"},{"key":"2281_CR20","unstructured":"Doebler P, Sousa-Pinto B. MADA package: meta-analysis of diagnostic accuracy. 0.5.12 ed2025"},{"issue":"8","key":"2281_CR21","first-page":"321","volume":"71","author":"A Acitores Cancela","year":"2024","unstructured":"Acitores Cancela A, Rodr\u00edguez Berrocal V (2024) Clinical significance of pituitary adenoma consistency in patients undergoing endoscopic transsphenoidal surgery. Endocrinol Diabetes Nutr (Engl Ed) 71(8):321\u2013323","journal-title":"Endocrinol Diabetes Nutr (Engl Ed)"},{"key":"2281_CR22","first-page":"1","volume":"66","author":"F Mariotti","year":"2025","unstructured":"Mariotti F, Agostini A, Borgheresi A, Marchegiani M, Zannotti A, Giacomelli G et al (2025) Insights into radiomics: a comprehensive review for beginners. Clin Trans Oncol 66:1\u201312","journal-title":"Clin Trans Oncol"},{"key":"2281_CR23","doi-asserted-by":"publisher","DOI":"10.1017\/9781107706958","volume-title":"MRI from picture to proton","author":"DW McRobbie","year":"2017","unstructured":"McRobbie DW, Moore EA, Graves MJ, Prince MR (2017) MRI from picture to proton. Cambridge university press"},{"issue":"12","key":"2281_CR24","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1016\/j.joca.2006.06.002","volume":"14","author":"M Nissi","year":"2006","unstructured":"Nissi M, Rieppo J, T\u00f6yr\u00e4s J, Laasanen M, Kiviranta I, Jurvelin J et al (2006) T2 relaxation time mapping reveals age-and species-related diversity of collagen network architecture in articular cartilage. Osteoarthritis Cartilage 14(12):1265\u20131271","journal-title":"Osteoarthritis Cartilage"},{"issue":"3","key":"2281_CR25","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1080\/02688690802617046","volume":"23","author":"H Wang","year":"2009","unstructured":"Wang H, Li W, Shi D, Ye Z, Qin F, Guo Y et al (2009) Expression of TGF beta 1 and pituitary adenoma fibrosis. Br J Neurosurg 23(3):293\u2013296","journal-title":"Br J Neurosurg"},{"issue":"53","key":"2281_CR26","doi-asserted-by":"publisher","first-page":"27239","DOI":"10.1074\/jbc.M116.756247","volume":"291","author":"R Nigdelioglu","year":"2016","unstructured":"Nigdelioglu R, Hamanaka RB, Meliton AY, O\u2019Leary E, Witt LJ, Cho T et al (2016) Transforming growth factor (TGF)-\u03b2 promotes de novo serine synthesis for collagen production. J Biol Chem 291(53):27239\u201327251","journal-title":"J Biol Chem"},{"issue":"5","key":"2281_CR27","doi-asserted-by":"publisher","first-page":"2784","DOI":"10.1021\/acs.biomac.4c01735","volume":"26","author":"G Giannetti","year":"2025","unstructured":"Giannetti G, Matsumura F, Caporaletti F, Micha D, Koenderink GH, Ilie IM et al (2025) Water and collagen: a mystery yet to unfold. Biomacromol 26(5):2784\u20132799","journal-title":"Biomacromol"},{"issue":"12","key":"2281_CR28","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1007\/s00234-020-02502-z","volume":"62","author":"R Cuocolo","year":"2020","unstructured":"Cuocolo R, Ugga L, Solari D, Corvino S, D\u2019Amico A, Russo D et al (2020) Prediction of pituitary adenoma surgical consistency: radiomic data mining and machine learning on T2-weighted MRI. Neuroradiology 62(12):1649\u20131656","journal-title":"Neuroradiology"},{"issue":"7","key":"2281_CR29","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1007\/s00234-019-02211-2","volume":"61","author":"A Zeynalova","year":"2019","unstructured":"Zeynalova A, Kocak B, Durmaz ES, Comunoglu N, Ozcan K, Ozcan G et al (2019) Preoperative evaluation of tumour consistency in pituitary macroadenomas: a machine learning-based histogram analysis on conventional T2-weighted MRI. Neuroradiology 61(7):767\u2013774","journal-title":"Neuroradiology"},{"key":"2281_CR30","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2025.1539432","volume":"15","author":"M Zou","year":"2025","unstructured":"Zou M, Li H, Yao H, Liu Y, Zhang J (2025) MR radiomics in assessment of consistency of pituitary macroadenoma: can T1-weighted contrast enhanced image improve diagnostic performance of T2-weighted image? Front Oncol 15:1539432","journal-title":"Front Oncol"},{"issue":"5","key":"2281_CR31","first-page":"513","volume":"40","author":"T Wan","year":"2021","unstructured":"Wan T, Zhao H, Li D, Ma J, Wu C, Meng M et al (2021) Preoperative evaluation of pituitary macroadenomas consistency using radiomic features from multi-parametric MRI. Chin J Biomed Eng 40(5):513\u2013520","journal-title":"Chin J Biomed Eng"},{"key":"2281_CR32","doi-asserted-by":"publisher","DOI":"10.1016\/j.bas.2025.104237","volume":"5","author":"M \u010cern\u00fd","year":"2025","unstructured":"\u010cern\u00fd M, Sedl\u00e1k V, M\u00e1jovsk\u00fd M, Vacek P, Sajfr\u00eddov\u00e1 K, Patai KR et al (2025) Preoperative assessment of tumor consistency and gross total resection in pituitary adenoma: radiomic analysis of T2-weighted MRI and interpretation of contributing radiomic features. Brain Spine 5:104237","journal-title":"Brain Spine"},{"key":"2281_CR33","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ejrad.2018.12.002","volume":"110","author":"W Rui","year":"2019","unstructured":"Rui W, Wu Y, Ma Z, Wang Y, Wang Y, Xu X et al (2019) MR textural analysis on contrast enhanced 3D-SPACE images in assessment of consistency of pituitary macroadenoma. Eur J Radiol 110:219\u2013224","journal-title":"Eur J Radiol"},{"key":"2281_CR34","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2019.00403","volume":"10","author":"Y Fan","year":"2019","unstructured":"Fan Y, Hua M, Mou A, Wu M, Liu X, Bao X et al (2019) Preoperative noninvasive radiomics approach predicts tumor consistency in patients with acromegaly: development and multicenter prospective validation. Front Endocrinol 10:403","journal-title":"Front Endocrinol"},{"issue":"45","key":"2281_CR35","first-page":"3626","volume":"100","author":"JM Chen","year":"2020","unstructured":"Chen JM, Wan Q, Zhu HY, Ge YQ, Wu LL, Zhai J et al (2020) The value of conventional magnetic resonance imaging based radiomic model in predicting the texture of pituitary macroadenoma. Zhonghua Yi Xue Za Zhi 100(45):3626\u20133631","journal-title":"Zhonghua Yi Xue Za Zhi"},{"issue":"9","key":"2281_CR36","doi-asserted-by":"publisher","first-page":"2535","DOI":"10.1210\/clinem\/dgab371","volume":"106","author":"H Wang","year":"2021","unstructured":"Wang H, Zhang W, Li S, Fan Y, Feng M, Wang R (2021) Development and evaluation of deep learning-based automated segmentation of pituitary adenoma in clinical task. J Clin Endocrinol Metab 106(9):2535\u20132546","journal-title":"J Clin Endocrinol Metab"},{"key":"2281_CR37","doi-asserted-by":"publisher","DOI":"10.1055\/a-2607-0735","author":"E Agosti","year":"2025","unstructured":"Agosti E, Cuocolo R, Mangili M, Rampinelli V, Veiceschi P, Cappelletti M et al (2025) Radiomics for preoperative assessment of pituitary adenoma consistency with T2-weighted MRI: a multicenter study. J Neurol Surg B Skull Base. https:\/\/doi.org\/10.1055\/a-2607-0735","journal-title":"J Neurol Surg B Skull Base"},{"issue":"8","key":"2281_CR38","doi-asserted-by":"publisher","first-page":"2470","DOI":"10.1177\/02841851231174462","volume":"64","author":"BAR Mendi","year":"2023","unstructured":"Mendi BAR, Batur H, \u00c7ay N, \u00c7ak\u0131r BT (2023) Radiomic analysis of preoperative magnetic resonance imaging for the prediction of pituitary adenoma consistency. Acta Radiol 64(8):2470\u20132478","journal-title":"Acta Radiol"},{"issue":"10","key":"2281_CR39","doi-asserted-by":"publisher","first-page":"2763","DOI":"10.1007\/s00234-025-03698-8","volume":"67","author":"M Liang","year":"2025","unstructured":"Liang M, Wang F, Yang Y, Wen L, Wang S, Zhang D (2025) MRI-based interpretable clinicoradiological and radiomics machine learning model for preoperative prediction of pituitary macroadenomas consistency: a dual-center study. Neuroradiology 67(10):2763\u20132776","journal-title":"Neuroradiology"},{"issue":"5","key":"2281_CR40","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1002\/jmri.26941","volume":"51","author":"CQ Su","year":"2020","unstructured":"Su CQ, Zhang X, Pan T, Chen XT, Chen W, Duan SF et al (2020) Texture analysis of high b-value diffusion-weighted imaging for evaluating consistency of pituitary macroadenomas. J Magn Reson Imaging 51(5):1507\u20131513","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"2281_CR41","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1186\/s12885-025-14799-1","volume":"25","author":"Q Yang","year":"2025","unstructured":"Yang Q, Wang Y, Wu J, Hu H, He Y, Wang Y et al (2025) Preoperative prediction of pituitary neuroendocrine tumor consistency based on multiparametric MRI radiomics: a multicenter study. BMC Cancer 25(1):1501","journal-title":"BMC Cancer"}],"container-title":["La radiologia medica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-026-02281-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11547-026-02281-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11547-026-02281-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T00:21:51Z","timestamp":1792023711000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11547-026-02281-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":41,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,10]]}},"alternative-id":["2281"],"URL":"https:\/\/doi.org\/10.1007\/s11547-026-02281-2","relation":{},"ISSN":["1826-6983"],"issn-type":[{"value":"1826-6983","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]},"assertion":[{"value":"16 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ferdinando Caranci serves as Editor for La Radiologia Medica. Other authors have no relevant financial or non-financial interests to disclose.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}}]}}