{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T11:42:42Z","timestamp":1771069362110,"version":"3.50.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2015,7,21]],"date-time":"2015-07-21T00:00:00Z","timestamp":1437436800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2015,7,21]],"date-time":"2015-07-21T00:00:00Z","timestamp":1437436800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R21 NS078607"],"award-info":[{"award-number":["R21 NS078607"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["KL2TR001088"],"award-info":[{"award-number":["KL2TR001088"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Dow-Crichlow Award","award":["Dow-Crichlow Award"],"award-info":[{"award-number":["Dow-Crichlow Award"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1007\/s11548-015-1255-5","type":"journal-article","created":{"date-parts":[[2015,7,20]],"date-time":"2015-07-20T04:06:21Z","timestamp":1437365181000},"page":"2009-2020","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Intraoperative CT as a registration benchmark for intervertebral motion compensation in image-guided open spinal surgery"],"prefix":"10.1007","volume":"10","author":[{"given":"Songbai","family":"Ji","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoyao","family":"Fan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keith D.","family":"Paulsen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David W.","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sohail K.","family":"Mirza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. Scott","family":"Lollis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,7,21]]},"reference":[{"key":"1255_CR1","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1146\/annurev-bioeng-070909-105249","volume":"12","author":"K Cleary","year":"2010","unstructured":"Cleary K, Peters TM (2010) Image-guided interventions: technology review and clinical applications. Annu Rev Biomed Eng 12:119\u2013142","journal-title":"Annu Rev Biomed Eng"},{"key":"1255_CR2","doi-asserted-by":"publisher","first-page":"138S","DOI":"10.1016\/j.spinee.2004.08.001","volume":"4","author":"RA Deyo","year":"2004","unstructured":"Deyo RA, Nachemson A, Mirza SK (2004) Spinal-fusion surgery\u2014the case for restraint. Spine J 4:138S\u2013142S","journal-title":"Spine J"},{"issue":"January","key":"1255_CR3","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1002\/rcs.69","volume":"2","author":"LT Holly","year":"2006","unstructured":"Holly LT (2006) Image-guided spinal surgery. Int J Med Robot Comput Assist Surg 2(January):7\u201315","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"1","key":"1255_CR4","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s00586-009-1091-9","volume":"19","author":"T Tjardes","year":"2010","unstructured":"Tjardes T, Shafizadeh S, Rixen D, Paffrath T, Bouillon B, Steinhausen ES, Baethis H (2010) Image-guided spine surgery: state of the art and future directions. Eur Spine J 19(1):25\u201345","journal-title":"Eur Spine J"},{"issue":"6","key":"1255_CR5","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1007\/s00586-010-1577-5","volume":"20","author":"N-F Tian","year":"2011","unstructured":"Tian N-F, Huang Q-S, Zhou P, Zhou Y, Wu R-K, Lou Y, Xu H-Z (2011) Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 20(6):846\u2013859","journal-title":"Eur Spine J"},{"issue":"2","key":"1255_CR6","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","volume":"21","author":"ID Gelalis","year":"2012","unstructured":"Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis Ta (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21(2):247\u2013255","journal-title":"Eur Spine J"},{"key":"1255_CR7","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/978-1-4614-7657-3_47","volume-title":"Intraoperative imaging and image-guided therapy","author":"GF Jost","year":"2014","unstructured":"Jost GF, Yonemura KS, Von Jako RA (2014) Intraoperative imaging and image-guided therapy. In: Jolesz FA (ed) Intraoperative imaging and image-guided therapy. Springer, New York, pp 613\u2013628"},{"issue":"3","key":"1255_CR8","doi-asserted-by":"publisher","first-page":"E11","DOI":"10.3171\/2010.1.FOCUS09275","volume":"28","author":"MJ Tormenti","year":"2010","unstructured":"Tormenti MJ, Kostov DB, Gardner P a, Kanter AS, Spiro RM, Okonkwo DO (2010) Intraoperative computed tomography image-guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery. Neurosurg Focus 28(3):E11","journal-title":"Neurosurg Focus"},{"issue":"1","key":"1255_CR9","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.wneu.2012.03.011","volume":"79","author":"R H\u00e4rtl","year":"2013","unstructured":"H\u00e4rtl R, Lam KS, Wang J, Korge A, Kandziora F, Audig\u00e9 L (2013) Worldwide survey on the use of navigation in spine surgery. World Neurosurg 79(1):162\u2013172","journal-title":"World Neurosurg"},{"issue":"6","key":"1255_CR10","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1007\/BF02750999","volume":"139","author":"K Roessler","year":"1997","unstructured":"Roessler K, Ungersboeck K, Dietrich W, Aichholzer M, Hittmeir K, Matula C, Czech T, Koos W (1997) Frameless stereotactic guided neurosurgery: clinical experience with an infrared based pointer device navigation system. Acta Neurochir 139(6):551\u2013559","journal-title":"Acta Neurochir"},{"issue":"2","key":"1255_CR11","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1227\/00006123-199302000-00009","volume":"32","author":"B Brodwater","year":"1993","unstructured":"Brodwater B, Roberts D, Nakajima T, Friets E, Strohbehn J (1993) Extracranial application of the frameless stereotactic operating microscope: experience with lumbar spine. Neurosurgery 32(2):209\u2013213","journal-title":"Neurosurgery"},{"key":"1255_CR12","first-page":"35","volume":"56","author":"EW Nottmeier","year":"2012","unstructured":"Nottmeier EW (2012) A review of image-guided spinal surgery. J Neurosurg Sci 56:35\u201347","journal-title":"J Neurosurg Sci"},{"issue":"4","key":"1255_CR13","first-page":"402","volume":"28","author":"SK Mirza","year":"2003","unstructured":"Mirza SK, Wiggins GC, Kuntz C, York JE, Bellabarba C, Knonodi M a, Chapman JR, Shaffrey CI (2003) Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study. Spine (Phila. Pa. 1976) 28(4):402\u2013413","journal-title":"Spine (Phila. Pa. 1976)"},{"key":"1255_CR14","doi-asserted-by":"publisher","unstructured":"Ji S, Fan X, Paulsen K, Roberts D, Mirza SK, Lollis SS (2015) Patient registration using intraoperative stereovision in image-guided open spinal surgery. IEEE Trans Biomed Eng. doi:\n                    10.1109\/TBME.2015.2415731","DOI":"10.1109\/TBME.2015.2415731"},{"key":"1255_CR15","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1201\/b17566-24","volume-title":"CRC handbook of imaging in biological mechanics","author":"S Ji","year":"2014","unstructured":"Ji S, Fan X, Roberts DW, Hartov A, Schaewe TJ, Simon DA, Paulsen KD (2014) Brain shift compensation via intraoperative imaging and data assimilation. In: Neu C, Genin G (eds) CRC handbook of imaging in biological mechanics. CRC Press, Boca Raton, pp 229\u2013240"},{"issue":"10","key":"1255_CR16","doi-asserted-by":"publisher","first-page":"4612","DOI":"10.1118\/1.2977728","volume":"35","author":"S Ji","year":"2008","unstructured":"Ji S, Wu Z, Hartov A, Roberts DW, Paulsen KD (2008) Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery. Med Phys 35(10):4612","journal-title":"Med Phys"},{"issue":"4","key":"1255_CR17","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1007\/s11548-011-0666-1","volume":"7","author":"CXB Yan","year":"2012","unstructured":"Yan CXB, Goulet B, Chen SJ-S, Tampieri D, Collins DL (2012) Validation of automated ultrasound-CT registration of vertebrae. Int J Comput Assist Radiol Surg 7(4):601\u2013610","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"1255_CR18","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1007\/s11548-010-0536-2","volume":"6","author":"CXB Yan","year":"2011","unstructured":"Yan CXB, Goulet B, Pelletier J, Chen SJ-S, Tampieri D, Collins DL (2011) Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery. Int J Comput Assist Radiol Surg 6(4):523\u2013537","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1255_CR19","doi-asserted-by":"crossref","unstructured":"Rasoulian A, Osborn J, Sojoudi S, Nouranian S, Lessoway VA, Rohling RN, Abolmaesumi P (2014) A system for ultrasound-guided spinal injections? A feasibility study. In: IPCAI, pp 90\u201399","DOI":"10.1007\/978-3-319-07521-1_10"},{"key":"1255_CR20","unstructured":"Nagpal S, Hacihaliloglu I, Ungi T, Rasoulian A, Osborn J, Lessoway Va, Rohling RN, Borschneck DP, Abolmaesumi P, Mousavi P (2014) A global CT to US registration of the lumbar spine. In: IPCAI, pp 108\u2013117"},{"issue":"4","key":"1255_CR21","first-page":"810","volume":"48","author":"JB West","year":"2001","unstructured":"West JB, Fitzpatrick JM, Sa Toms, Maurer CR, Maciunas RJ (2001) Fiducial point placement and the accuracy of point-based, rigid body registration. Neurosurgery 48(4):810\u2013816 (discussion 816\u2013817)","journal-title":"Neurosurgery"},{"key":"1255_CR22","doi-asserted-by":"crossref","unstructured":"Winter S, Brendel B, Pechlivanis I, Schmieder K, Igel C (2008) Registration of CT and intraoperative 3-D ultrasound images of the spine using evolutionary and gradient-based methods. IEEE Trans Evol Comput 12(3):284\u2013296","DOI":"10.1109\/TEVC.2007.907558"},{"key":"1255_CR23","doi-asserted-by":"crossref","unstructured":"Lang A, Mousavi P, Gill S, Fichtinger G, Abolmaesumi P (2012) Multi-modal registration of speckle-tracked freehand 3D ultrasound to CT in the lumbar spine. Med Image Anal 16(3):675\u2013686","DOI":"10.1016\/j.media.2011.07.006"},{"issue":"3","key":"1255_CR24","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.media.2010.07.008","volume":"16","author":"S Gill","year":"2012","unstructured":"Gill S, Abolmaesumi P, Fichtinger G, Boisvert J, Pichora D, Borshneck D, Mousavi P (2012) Biomechanically constrained groupwise ultrasound to CT registration of the lumbar spine. Med Image Anal 16(3):662\u2013674","journal-title":"Med Image Anal"},{"issue":"3","key":"1255_CR25","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.media.2009.02.004","volume":"13","author":"T Klinder","year":"2009","unstructured":"Klinder T, Ostermann J, Ehm M, Franz A, Kneser R, Lorenz C (2009) Automated model-based vertebra detection, identification, and segmentation in CT images. Med Image Anal 13(3):471\u2013482","journal-title":"Med Image Anal"},{"key":"1255_CR26","doi-asserted-by":"crossref","unstructured":"Ma J, Lu L, Zhan Y, Zhou X (2010) Hierarchical segmentation and identification of thoracic vertebra using learning-based edge detection and coarse-to-fine deformable model. In: MICCAI, pp 19\u201327","DOI":"10.1007\/978-3-642-15705-9_3"},{"key":"1255_CR27","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.compmedimag.2009.02.006","volume":"33","author":"Y Kim","year":"2009","unstructured":"Kim Y, Kim D (2009) A fully automatic vertebra segmentation method using 3D deformable fences. Comput Med Imaging Graph 33:343\u2013352","journal-title":"Comput Med Imaging Graph"},{"issue":"10","key":"1255_CR28","doi-asserted-by":"publisher","first-page":"1890","DOI":"10.1109\/TMI.2013.2268424","volume":"32","author":"A Rasoulian","year":"2013","unstructured":"Rasoulian A, Member S, Rohling R, Member S (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape $$+$$ pose model. IEEE Trans Med Imaging 32(10):1890\u20131900","journal-title":"IEEE Trans Med Imaging"},{"issue":"7","key":"1255_CR29","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1016\/j.media.2014.07.001","volume":"18","author":"S Ji","year":"2014","unstructured":"Ji S, Fan X, Roberts DW, Hartov A, Paulsen KD (2014) Cortical surface shift estimation using stereovision and optical flow motion tracking via projection image registration. Med Image Anal 18(7):1169\u20131183","journal-title":"Med Image Anal"},{"issue":"6","key":"1255_CR30","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1109\/TMI.2005.848373","volume":"24","author":"TK Sinha","year":"2005","unstructured":"Sinha TK, Dawant BM, Duay V, Cash DM, Weil RJ, Thompson RC, Weaver KD, Miga MI (2005) A method to track cortical surface deformations using a laser range scanner. IEEE Trans Med Imaging 24(6):767\u2013781","journal-title":"IEEE Trans Med Imaging"},{"key":"1255_CR31","unstructured":"Kjer HM, Wilm J (2010) Evaluation of surface registration algorithms for PET motion correction. Technical University of Denmark"},{"issue":"14","key":"1255_CR32","doi-asserted-by":"publisher","first-page":"3761","DOI":"10.1088\/0031-9155\/59\/14\/3761","volume":"59","author":"S Reaungamornrat","year":"2014","unstructured":"Reaungamornrat S, Wang aS, Uneri a, Otake Y, Khanna aJ, Siewerdsen JH (2014) Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery. Phys Med Biol 59(14):3761\u20133787","journal-title":"Phys Med Biol"},{"key":"1255_CR33","doi-asserted-by":"crossref","unstructured":"Fan X, Ji S, Hartov A, Roberts D, Paulsen K (2012) Registering stereovision surface with preoperative magnetic resonance images for brain shift compensation. In: Proceedings of SPIE, medical imaging 2012: visualization, image-guided procedures, and modeling, vol 8316","DOI":"10.1117\/12.911081"},{"issue":"6","key":"1255_CR34","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1109\/TITB.2009.2025373","volume":"13","author":"P Paul","year":"2009","unstructured":"Paul P, Morandi X, Jannin P (2009) A surface registration method for quantification of intraoperative brain deformations in image-guided neurosurgery. IEEE Trans Inf Technol Biomed 13(6):976\u2013983","journal-title":"IEEE Trans Inf Technol Biomed"},{"issue":"11","key":"1255_CR35","doi-asserted-by":"publisher","first-page":"1867","DOI":"10.1007\/s00586-007-0373-3","volume":"16","author":"R Fujii","year":"2007","unstructured":"Fujii R, Sakaura H, Mukai Y, Hosono N, Ishii T, Iwasaki M, Yoshikawa H, Sugamoto K (2007) Kinematics of the lumbar spine in trunk rotation: in vivo three-dimensional analysis using magnetic resonance imaging. Eur Spine J 16(11):1867\u20131874","journal-title":"Eur Spine J"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1255-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-015-1255-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1255-5","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1255-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:36:34Z","timestamp":1589664994000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-015-1255-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7,21]]},"references-count":35,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["1255"],"URL":"https:\/\/doi.org\/10.1007\/s11548-015-1255-5","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,21]]},"assertion":[{"value":"27 March 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2015","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"K.D. Paulsen and D.W. Roberts receive research support from Medtronic Inc. and Carl Zeiss Inc. D.W. Roberts serves on the scientific advisory board for Medtronic Inc., Carl Zeiss Inc., and IMRIS Inc. Other authors declare that they have no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}