{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:24:51Z","timestamp":1740144291620,"version":"3.37.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"DOI":"10.1007\/s11548-024-03127-w","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T09:01:59Z","timestamp":1713171719000},"page":"1555-1567","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The development and testing of a smart sensorized guide wire for catheterization in a \u201cblood\u201d vessel phantom to support aortic valve implementation"],"prefix":"10.1007","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5026-6251","authenticated-orcid":false,"given":"M.","family":"Berger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Kuhn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1459-7234","authenticated-orcid":false,"given":"M.","family":"Pillei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7656-5812","authenticated-orcid":false,"given":"N.","family":"Bonaros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9379-2080","authenticated-orcid":false,"given":"T.","family":"Senfter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,15]]},"reference":[{"key":"3127_CR1","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1016\/j.pcad.2014.02.006","volume":"56","author":"JJ Thaden","year":"2014","unstructured":"Thaden JJ, Nkomo VT, Enriquez-Sarano M (2014) The global burden of aortic stenosis. Prog Cardiovasc Dis 56:565\u2013571","journal-title":"Prog Cardiovasc Dis"},{"key":"3127_CR2","first-page":"1","volume":"2","author":"BR Lindman","year":"2016","unstructured":"Lindman BR, Clavel M-A, Mathieu P, Lung B, Lancellotti P, Otto CM, Pibarot P (2016) Calcific aortic stenosis. Nat Rev Dis Prim 2:1\u201328","journal-title":"Nat Rev Dis Prim"},{"key":"3127_CR3","first-page":"26","volume":"4","author":"M Glauber","year":"2015","unstructured":"Glauber M, Ferrarini M, Miceli A (2015) Minimally invasive aortic valve surgery: state of the art and future directions. Ann Cardiothorac Surg 4:26","journal-title":"Ann Cardiothorac Surg"},{"key":"3127_CR4","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1093\/ejcts\/ezy333","volume":"55","author":"R Cocchieri","year":"2019","unstructured":"Cocchieri R, Petzina R, Romano M, Jagielak D, Bonaros N, Aiello M, Lapeze J, Laine M, Chocron S, Muir D, Eichinger W, Thielmann M, Labrousse L, Rein KA, Verhoye JP, Gerosa G, Bapat V, Baumbach H, Sims H, Deutsch C, Bramlage P, Kurucova J, Thoenes M, Frank D (2019) Outcomes after transaortic transcatheter aortic valve implantation: long-term findings from the European ROUTE. Eur J Cardio-Thoracic Surg 55:737\u2013743","journal-title":"Eur J Cardio-Thoracic Surg"},{"key":"3127_CR5","doi-asserted-by":"publisher","first-page":"3143","DOI":"10.1093\/eurheartj\/ehz275","volume":"40","author":"GCM Siontis","year":"2019","unstructured":"Siontis GCM, Overtchouk P, Cahill TJ, Modine T, Prendergast B, Praz F, Pilgrim Th, Petrinic T, Nikolakopoulou A, Salanti G, Sondergaard L, Verma S, J\u00fcni P, Windecker S (2019) Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis. Eur Heart J 40:3143\u20133153","journal-title":"Eur Heart J"},{"key":"3127_CR6","doi-asserted-by":"publisher","first-page":"20130595","DOI":"10.1259\/bjr.20130595","volume":"87","author":"B Clayton","year":"2014","unstructured":"Clayton B, Morgan-Hughes G, Roobottom C (2014) Transcatheter aortic valve insertion (TAVI): a review. Br J Radiol 87:20130595","journal-title":"Br J Radiol"},{"key":"3127_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13012-015-0330-1","volume":"10","author":"S Merkel","year":"2015","unstructured":"Merkel S, Eikermann M, Neugebauer EA, von Bandemer S (2015) The transcatheter aortic valve implementation (TAVI)\u2014a qualitative approach to the implementation and diffusion of a minimally invasive surgical procedure. Implement Sci 10:1\u20139","journal-title":"Implement Sci"},{"key":"3127_CR8","first-page":"1","volume":"12","author":"S Sehatzadeh","year":"2012","unstructured":"Sehatzadeh S, Doble B, Xie F, Blackhouse G, Campbell K, Kaulback K, Cahndra K, Goeree R (2012) Transcatheter aortic valve implantation (TAVI) for treatment of aortic valve stenosis: an evidence-based analysis (part B). Ont Health Technol Assess Ser 12:1","journal-title":"Ont Health Technol Assess Ser"},{"key":"3127_CR9","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1088\/0964-1726\/10\/6\/301","volume":"10","author":"JW Judy","year":"2001","unstructured":"Judy JW (2001) Microelectromechanical systems (MEMS): fabrication, design and applications. Smart Mater Struct 10:1115","journal-title":"Smart Mater Struct"},{"key":"3127_CR10","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1109\/MIM.2012.6174574","volume":"15","author":"F Khoshnoud","year":"2012","unstructured":"Khoshnoud F, de Silva CW (2012) Recent advances in MEMS sensor technology-mechanical applications. IEEE Instrum Meas Mag 15:14\u201324","journal-title":"IEEE Instrum Meas Mag"},{"key":"3127_CR11","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.sna.2018.07.006","volume":"281","author":"AS Fiorillo","year":"2018","unstructured":"Fiorillo AS, Critello CD, Pullano SA (2018) Theory, technology and applications of piezoresistive sensors: a review. Sens Actuators A Phys 281:156\u2013175","journal-title":"Sens Actuators A Phys"},{"key":"3127_CR12","doi-asserted-by":"crossref","unstructured":"Stefanova N, Hessinger M, Opitz T, Werthsch\u00fctzky R (2016) Characteristic of a force sensing guide wire for minimally invasive cardiac surgery. In: 2016 38th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE, pp 5220\u20135223","DOI":"10.1109\/EMBC.2016.7591904"},{"key":"3127_CR13","doi-asserted-by":"publisher","first-page":"2669","DOI":"10.1021\/acsaelm.0c00538","volume":"2","author":"B Gil","year":"2020","unstructured":"Gil B, Li B, Gao A, Yang G-Z (2020) Miniaturized piezo force sensor for a medical catheter and implantable device. ACS Appl Electron Mater 2:2669\u20132677","journal-title":"ACS Appl Electron Mater"},{"key":"3127_CR14","doi-asserted-by":"crossref","unstructured":"Han B, Yoon Y-J, Hamidullah M, Lin AT, Park WT (2013) Silicon nanowire based ring shape force sensor for sensorized guidewires. In: 2013 transducers & eurosensors XXVII: The 17th international conference on solid-state sensors, actuators and microsystems (TRANSDUCERS & EUROSENSORS XXVII). IEEE, pp 718\u2013721","DOI":"10.1109\/Transducers.2013.6626867"},{"key":"3127_CR15","unstructured":"Lou L, Ramakrishna K, Shao L, Park WT, Yu D, Lim L, Wee Y, Kripesh V, Feng H, Chua BSY, Lee C KwongDL (2010) Sensorized guidewires with MEMS tri-axial force sensor for minimally invasive surgical applications. In: 2010 Annual international conference of the IEEE engineering in medicine and biology. IEEE, pp 6461\u20136464"},{"key":"3127_CR16","doi-asserted-by":"crossref","unstructured":"Tanimoto M, Arai F, Fukuda T, Iwata H, Itoigawa, K, Gotoh Y, Hashimoto M, Negoro M (1998) Micro force sensor for intravascular neurosurgery and in vivo experiment. In: Proceedings MEMS 98. IEEE. Eleventh annual international workshop on micro electro mechanical systems. an investigation of micro structures, sensors, actuators, machines and systems (Cat. No. 98CH36176). IEEE, pp 504\u2013509","DOI":"10.1109\/MEMSYS.1998.659809"},{"key":"3127_CR17","doi-asserted-by":"publisher","first-page":"5377","DOI":"10.3390\/s21165377","volume":"21","author":"N Bandari","year":"2021","unstructured":"Bandari N, Dargahi J, Packirisamy M (2021) Optical fiber array sensor for force estimation and localization in tavi procedure: design, modeling, analysis and validation. Sensors 21:5377","journal-title":"Sensors"},{"key":"3127_CR18","unstructured":"Entwurf KN Pr\u00e4paration und Charakterisierung von F\u00fchrungsdr\u00e4hten mit integriertem Silizium-Mikro-Kraftsensor f\u00fcr die Herzkranzgef\u00e4\u00df-Katheterisierung"},{"key":"3127_CR19","unstructured":"Kuhn N (2023) Feedback-giving guide wire for vaso-protective use in minimal invasive heart surgery. MCI Innsbruck"},{"key":"3127_CR20","first-page":"103","volume":"1","author":"J Bahl","year":"2015","unstructured":"Bahl J (2015) Study of predictive power of moving averages as a tool of technical analysis. J Stud Manag Plan 1:103\u2013114","journal-title":"J Stud Manag Plan"},{"key":"3127_CR21","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1134\/S1061934819070013","volume":"74","author":"AA Al-Mbaideen","year":"2019","unstructured":"Al-Mbaideen AA (2019) Application of moving average filter for the quantitative analysis of the NIR spectra. J Anal Chem 74:686\u2013692. https:\/\/doi.org\/10.1134\/S1061934819070013","journal-title":"J Anal Chem"},{"key":"3127_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/152730","volume":"2015","author":"DJ Vitello","year":"2015","unstructured":"Vitello DJ, Ripper RM, Fettiplace MR, Fettiplace MR, Weinberg GL, Vitello JM (2015) Blood density is nearly equal to water density: a validation study of the gravimetric method of measuring intraoperative blood loss. J Vet Med 2015:1\u20134. https:\/\/doi.org\/10.1155\/2015\/152730","journal-title":"J Vet Med"},{"key":"3127_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphys.2019.01329","volume":"10","author":"E Nader","year":"2019","unstructured":"Nader E, Skinner S, Romana M, Fort R, Lemonne N, Guillot N, Gauthier A, Antoine Jonville S, Renoux C, Dessources MDH, Stauffler E, Joly P, Bertand Y, Connes P (2019) Blood rheology: key parameters, impact on blood flow, role in sickle cell disease and effects of exercise. Front Physiol 10:1\u201314. https:\/\/doi.org\/10.3389\/fphys.2019.01329","journal-title":"Front Physiol"},{"key":"3127_CR24","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/0378-4371(88)90015-5","volume":"151","author":"DA Berstad","year":"1988","unstructured":"Berstad DA, Knapstad B, Lamvik M, Skj\u00f8lsvik PA, T\u00f8rklep K, \u00d8ye HA (1988) Accurate measurements of the viscosity of water in the temperature range 19.5-25.5\u00b0C. Phys A Stat Mech Appl 151:246\u2013280. https:\/\/doi.org\/10.1016\/0378-4371(88)90015-5","journal-title":"Phys A Stat Mech Appl"},{"key":"3127_CR25","doi-asserted-by":"crossref","unstructured":"Denisenko NS, Kulik VM (2017) In-house manufacturing of cylindrical silicone models for hemodynamic research. In: AIP conference proceedings. AIP Publishing, Vol 1893, No 1","DOI":"10.1063\/1.5007578"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03127-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-024-03127-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-024-03127-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,16]],"date-time":"2024-08-16T15:21:14Z","timestamp":1723821674000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-024-03127-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,15]]},"references-count":25,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["3127"],"URL":"https:\/\/doi.org\/10.1007\/s11548-024-03127-w","relation":{},"ISSN":["1861-6429"],"issn-type":[{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2024,4,15]]},"assertion":[{"value":"23 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest. There were no human or animal studies involved.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}